Ductless Split Systems
Wall-mounted, Single Zone Heat Pump
PURCHASER P.O. # DATE
PROJECT LOCATION
ENGINEER ARCHITECT
SUBMITTED BY FOR APPROVAL FOR REFERENCE
ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH MODEL
Features
• Inverter technology (variable speed compressor)
• High efficiency for low operating cost
• DiamonGold Advanced Corrosion Protection™
• Self-cleaning indoor coil
• Cooling/Heating/Fan mode
• Surge Cool/Heat
• Natural air flow
• 4-Way auto swing
• Ultra quiet operation
• Sleep mode
• Dry mode
• Auto restart
• Auto changeover
• Built-in low ambient standard, down to 14ºF
(Cooling Mode)
• 24-hour on/off timer
• Multiple ease of installation features
• BLDC Motor
MW24Y3J, MW30Y3J, MW36Y3J
WIRELESS
REMOTE CONTROL
All Inverter line
PRECISION
PARTS
COMPRESSOR
WARRANTY
WARRANTY
Ductless_Wall-mounted_Single_Zone_Heat_Pump_Submittal_2016
MR24Y3J, MR30Y3J, MR36Y3J
PERFORMANCE RATINGS Single Zone Wall-Mounted - Heat Pump
24k 30k 36k
SYSTEM MODEL NO. M24YJ M30YJ M36YJ
INDOOR MODEL MW24Y3J MW30Y3J MW36Y3J
OUTDOOR MODEL MR24Y3J MR30Y3J MR36Y3J
SPECIFICATIONS
CAPACITY COOLING (RATED) Btu 22,000 30,000 33,000
CAPACITY COOLING (MIN~MAX) Btu 3,070~30,030 3,070~34,000 3,070~34,000
CAPACITY HEATING @ 47
CAPACITY HEATING @ 17
CAPACITY HEATING (MIN~MAX) Btu 3,070~38,898 3,070~38,900 3,070~38,900
COOLING AMPS 7.9 13.4 17.0
HEATING AMPS 10.7 13.9 16.2
SENSIBLE HEAT RATIO .72 .78 .78
SEER 21.0 18.5 16.5
EER 12.5 10.0 8.2
HSPF 11.0 10.0 10.0
ENERGY STAR YES No No
MOISTURE REMOVAL Pts/h 5.5 6.0 6.5
AIRFLOW (QUIET, LOW, MED, HIGH) CFM 300/389/512/600 459/530/706/848 459/530/706/848
SOUND RATING - INDOOR dB-A 33 / 39 / 43 / 46 33 / 39 / 44 / 49 37 / 40 / 44 / 49
SOUND RATING - OUTDOOR dB-A 54 55 55
OPERATING RANGE (COOLING)(WIND BAFFLE) °F 14(0)~118 14(0)~118 14(0)~118
OPERATING RANGE (HEATING) °F -4~75 -4~75 -4~75
EST. YEARLY OPERATING COST $ 158 270 395
POWER AND COMMUNICATION CABLE No. x AWG 4 x 14 4 x 14 4 x 14
ELECTRICAL DATA
POWER SOURCE V 208/230/60/1 208/230/60/1 230/208/60/1
MINIMUM AMPACITY A 19 19 19
COOLING WATTS W 1760 3000 4024
MAX. TD FUSE/BREAKER A 25 25 25
REFRIGERATION SYSTEM
REFRIGERANT R410A R410A R410A
COMPRESSOR TYPE Inverter Inverter Inverter
CONNECTIONS Flare Flare Flare
LIQUID LINE O.D. in 3/8 3/8 3/8
SUCTION LINE O.D. in 5/8 5/8 5/8
FACTORY PRECHARGE ft 25 25 25
REFRIGERANT CHARGE oz 78 78 78
MIN./MAX. LINE LENGTH ft 10~164 10~164 10~164
MAX. HEIGHT DIFFERENCE ft 98 98 98
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X D in 46-7/8 x 13-5/8 x10-3/8 46-7/8 x13-5/8 x 10-3/8 46-7/8 x 13-5/8 x 10-3/8
NET WEIGHT lbs 40 40 40
SHIPPING WEIGHT lbs 46 46 46
OUTDOOR UNIT
W X H X D in 34-5/16 x31-1/2 x12-5/8 34-5/16 x31-1/2 x12-5/8 34-5/16 x31-1/2 x12-5/8
NET WEIGHT lbs 125 125 125
SHIPPING WEIGHT lbs 132 132 132
TOTAL NET WEIGHT lbs 165 165 165
TOTAL SHIPPING WEIGHT lbs 178 178 178
USED WITH
9000 and 12000
BTU indoor units
18000 BTU indoor units
24000,30000 and
36000 BTU indoor units
0
F (RATED)
0
F (RATED)
Length Ft.
Liquid Suction Kit#
15’ 1/4” 3/8” T3215 0
35’ 1/4” 3/8” T3235 0
15’ 1/4” 1/2” T421 50
35’ 1/4” 1/2” T423 50
15’ 3/8” 5/8” T5315 0
35’ 3/8” 5/8” T53350
Btu 27,600 32,000 35,200
Btu 17,900 21,200 23,200
ThermostatRefrigeration line sets*
WIRED
CONTROLLER
DWC1
* Used with all models.
Low ambient wind baffle kit
WIND BAFFLE USED WITH
DLAWB1 9000 - 12000 Btu wall-mounted single
zone models
DLAWB2 18000 - 36000 Btu wall-mounted
single zone models
Ductless_Wall-mounted_Single_Zone_Heat_Pump_Submittal_2016
SPECIFICATIONS
Your operating costs
will depend on your
utility rates and use. The
estimated operating cost
is based on a electricity
cost of $.115 per kWH.
For more information,
visit www.ftc.gov/energy.
*Insulated line sets are
available for all Friedrich
split systems in 15 ft. and
35 ft. lengths. Each line
set is equipped with are
nuts on both ends. Both
liquid and suction lines
are insulated. Line sets
can be joined together
with eld supplied double
male connectors. Each
system requires one
line set for each indoor
unit installed. On multizone systems, line sets
should be ordered based
on individual indoor
unit capacities not total
system capacity.