Ductless Split Systems
Wall Mounted, Heat Pump Dual-zone
PURCHASER P.O. # DATE
PROJECT LOCATION
ENGINEER ARCHITECT
SUBMITTED BY FOR APPROVAL FOR REFERENCE
ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH MODEL
Features
• LCD remote for each indoor unit
• 24-hour timer and sleep timer
• Auto/cool/dry/fan/heat modes
• Four fan speeds heating or cooling:
high/medium/low/quiet, plus auto-fan
• Continuous ‘Air Sweep’ UP/DOWN
• Auto-restart after power interruptions
• Auto-shut aps close when unit is off
for a sleeker appearance
• Washable, reusable air lters
• Removable front grille
• Auto-changeover (heat pump models)
• Secured remote control holder
• Four different transmitter codes to prevent
unintentional interference with nearby units
MW18DYF, M21DYF
M24DYF
All Inverter line
Ductless_Dual_Zone_Heat Pump_Submittal_10
MR24DY3

Wall Mounted, Heat Pump Single-zone
Specifications
PERFORMANCE RATINGS
SYSTEM MODEL NO. M18DYF M21DYF M24DYF
INDOOR MODEL 2 x MW09Y3FM MW09Y3FM MW12Y3FM 2 x MW12Y3FM
OUTDOOR MODEL MR24DY3F MR24DY3F MR24DY3F
Capacity Cooling Btu 9500 ea. 9500 12000 12000 ea.
CapaCity Cooling Min - Max
SenSible Heat Ratio
CapaCity Heating @ 47°F
CapaCity Heating Min - Max
CapaCity Heating @ 17°F
HSpF
SeeR
eeR
eneRgy StaR
MoiStuRe ReMoval
aiRFlow (Quiet, low, Med, HigH)
Sound Rating - indooR
Sound Rating - outdooR
opeRationg Range (Heating)
eSt. yeaRly opeRating CoSt
eleCtRiCal data (all indooR unitS ReCeive poweR FRoM outdooR unit; valueS liSted aRe total)
poweR SouRCe
Min. aMpaCity
Cooling wattS
Max. td FuSe/bReakeR
ReFRigeRation SySteM
ReFRigeRant
CoMpReSSoR type
ConneCtionS
liQuid line o.d.
SuCtion line o.d.
FaCtoRy pReCHaRge
Max. line lengtH
Max. HeigHt diFFeRenCe
diMenSionS & weigHt
indooR unit
w x H x d
net weigHt
SHipping weigHt
outdooR unit
w x H x d
net weigHt
SHipping weigHt
Btu 5100-11300 ea. 5100-11300 ea. 5100-13600 ea 5100-13600 ea
0.77 0.77 0.77 0.77
Btu 11000 ea. 11000 ea. 14000 14000 ea.
Btu 5100-13000 ea. 5100-13000 ea. 5100-15400 ea. 5100-15400 ea.
Btu 9500 ea. 9500 ea. 11000 10500 ea.
9.0 9.0 9.0
16.5 16.5 16.5
12.2 11.2 10.4
YES NO NO
Pts/h 2.9 ea. 2.9 ea 3.7 ea. 3.7 ea.
CFM 185,220,260,295 185,220,260,295 215,250,305,355 215,250,305,355
dB-A 27,29,33,37 27,29,33,37 30,34,39,42 30,34,39,42
dB-A 52 52 52
°F 0 - 115 (14 - 75) 0 - 115 (14 - 75) 0 - 115 (14 - 75)
$128 $152 $152 $184
230/(208)-60-1 230/(208)-60-1 230/(208)-60-1
A 15 15 15
W 1600 1900 2300
A 20 20 20
R410A R410A R410A
Inverter Inverter Inverter
Flare Flare Flare
in
in
ft 98' 98' 98'
ft Each unit:82 Total:98 Each unit:82 Total:98 Each unit:82 Total:98
ft 33' 33' 33'
in
31 1/8" x 10 7/8" x 8 1/2" ea. 31 1/8" x 10 7/8" x 8 1/2" ea. 31 1/8" x 10 7/8" x 8 1/2" ea.
lbs 21 ea. 21 21 21 ea.
lbs 26 ea. 26 26 26 ea.
in
lbs 136 136 136
lbs 154 154 154
1/4" 1/4" 1/4" 1/4"
3/8" 3/8" 3/8" 3/8"
35 3/8" x 32 5/8" x 13" 35 3/8" x 32 5/8" x 13" 35 3/8" x 32 5/8" x 13"
Ductless Split Systems
NOTE: All models have low ambient
capabilities built-in. Capacity is
reduced as 0 degrees Fahrenheit is
approached.
NOTE: All R410A models have 1/2˝
UNF 20 thread per inch charging and
vacuuming ports. An adapter must be
used for 1/4˝ gauges. Adapter part
number 67270018 is available through
Friedrich parts distributors.
Due to continuing research in
new energy-saving technology,
specications are subject to change
without notice.
Refrigeration line sets
USED WITH: LENGTH-FT. LIQUID SUCTION KIT#
All 9000 and
12000 Btu
indoor units
Ductless_Dual_Zone_Heat_Pump_Submittal_11
15'
35'
1/4” 3/8”
1/4” 3/8”
T32150
T32350
Insulated line sets are available for all Friedrich split systems in
15 ft. and 35 ft. lengths. Each line set is equipped with are nuts
on both ends. Both liquid and suction lines are insulated. Line
sets can be joined together with eld supplied double female
connectors. Each system requires one line set for each indoor
unit installed. On multi-zone systems, line sets should be ordered
based on individual indoor unit capacities not total system
capacity. For example, a M18DYF uses 2 line sets for 9,000 Btu
units, not 1 for the 18,000 Btu product.