Franklin 710 User Manual

OPERATING INSTRUCTIONS
WARRANTY
Professional
STUD FINDER
PROSENSOR 710
IMPORTANT: READ BEFORE USING. SAVE THESE INSTRUCTIONS.
Operating/Safety Instructions
FRANKLIN SENSORS PROSENSOR 710
Congratulations on selecting the most advanced wall sensor on the market. Your ProSensor 710 incorporates advanced technology that precisely
senses the surface in thirteen locations
simultaneously, then instantly identies the location(s) of hidden object(s). It is the
easiest-to-use, fastest, and most accurate stud
nder on the market.
SAFETY RULES FOR THE PROSENSOR 710
WARNING: Read all instructions before use. Failure to follow safety instructions may result in electric shock, re, and/or serious injury and death.
SAVE THESE INSTRUCTIONS
WARNING: It is possible that there may be
wood, metal, wiring, or other objects behind the surface that are not detected. It is also possible that the stud nder may detect pipes, wires, or other objects that the user may not want it to detect. The stud nder is designed to detect any inconsistency without identifying the nature of the inconsistency. The stud nder does not identify what type of object it detects. The
illuminated LEDs may indicate the location of many different features including, but not limited
to, studs, beams, water pipes, gas pipes, wires,
an inconsistency in the surface material or
paint, etc.
WARNING: TURN OFF all gas, water, and electric power before using any drilling or penetrating devices or equipment including drills, saws, routers, hammers, nails, screws, etc.
WARNING: The stud nder alone should not be relied upon exclusively to locate objects behind a scanned surface. Use other sources of information to help locate objects. Other sources
of information may include, but is not limited to,
construction plans, visible points of entry of pipes, location of switches and outlets, and standard 16" and 24" stud spacing practices.
FAILURE TO TAKE THESE AND OTHER NECESSARY PRECAUTIONS COULD RESULT IN ELECTRIC SHOCK, FIRE, AND/OR SERIOUS INJURY AND DEATH.
Clean
Before turning on, ensure that the stud nder is clean and dry. If necessary, wipe the stud nder dry using a clean cloth. If the detector is wet or dirty it may not operate properly.
Temperature
If the stud nder is subject to a signicant temperature change, allow it adjust to the ambient temperature before using. The entire
area of the sensor board should be at a similar
temperature for best operation.
1
2
5
3
TO OPERATE:
• Hold the stud nder by the handle. Do not
touch the detector outside of the handle area
while scanning.
• Place the ProSensor 710 rmly against the surface and press the “on” button. Continue to hold the “on” button down.
• LED lights will immediately display the location of any hidden objects.
• The “on” button may be pressed before or after placing the stud nder on the surface to be scanned. The stud nder will detect studs without sliding the stud nder across the wall, but will also operate correctly if it is slid across the wall.
• If more than one hidden object is present, the
stud nder will show the location of more than one hidden object.
• LED lights indicate the width of hidden object(s).
• On some surfaces it may be helpful to slide the
stud nder up and down to conrm the location of a stud.
6
1. LED Lights
2. Ergonomic Handle
3. “On” Button
4. Battery Cover
5. Detector Housing
6. Sensor Board
4
STICKERS / DECALS
Do not place decals or stickers, especially metal decals or stickers on the sensor board, or on the
stud nder in any place.
DISASSEMBLY / TEFLON PADS
Do not disassemble the stud nder or remove the teon pads that are on the bottom. The stud nder will not operate correctly without the teon pads properly in place.
Franklin Sensors warrants this product to be free from defects in material and workmanship for one year. This LIMITED WARRANTY does not cover products that are improperly used, abused, or altered. Defective products will be replaced or repaired. If a product is found to be defective within the warranty period, Franklin Sensors will,
at its sole discretion, either repair or replace the
defective product. This limited warranty does not
apply to products that are subjected to freight damage, accident, abuse, alteration, misuse,
SENSING THROUGH DIFFERENT MATERIALS:
Moisture
The scanned surface should be clean and dry. Paint and wallpaper need to be completely dry before scanning for studs. It may take up to 2 weeks for wallpaper to dry enough to detect studs.
Curved Surfaces
There is a minor degree of curvature in the walls of most homes and buildings. The curvature is small enough that it may not be noticed. The ProSensor 710 can detect objects through curved surfaces because the ProSensor 710 has a
sensor board that bends slightly to match the
contour of most walls. Press the stud nder rmly against the surface and the sensor board will match the contour of the surface, and provide
BATTERIES
The ProSensor 710 uses 2 AA batteries. Use
alkaline batteries only; do not use rechargeable
batteries. Replace both batteries at the same time.
REPLACING THE BATTERIES
• Remove battery cover, by sliding the cover to the left and lifting. Remove batteries and
dispose of the
batteries properly. Please recycle.
• Replace with 2 new AA alkaline batteries.
• Replace battery cover. Close battery cover by sliding the cover to the right until it snaps into place.
improper repair, etc. Franklin Sensors and Franklin Sensors’ authorized distributors shall
bear no other liability or obligation under
this warranty.
Franklin Sensors does not authorize any person or representative warranty or obligation with the sale of this product. Franklin Sensors’ limited warranty is valid only if you retain proof of purchase from Franklin Sensors or a Franklin Sensors authorized dealer for this product. If you purchase this
product from any other source, your purchase is
“AS IS,” which means Franklin Sensors grants you no warranty, and that you, not Franklin Sensors, assume the entire risk of the quality and performance of this product. The warranty
period for any replaced and/or repaired part
under this warranty shall expire at the end of the original warranty period.
the best reading.
Foil-Backed Insulation
Although foil covered insulation is not very
common, metal foil can cause inconsistent
readings with all electronic stud nders, including the ProSensor 710.
Metallic Content in Wallpaper
Wallpaper with metallic content can block the detector’s signals.
Textured Walls and Acoustic Ceilings
The ProSensor 710 is capable of detecting studs through many textured surfaces. The stud nder should be placed rmly against the surface for best results.
STORAGE
Store the stud nder in a clean, dry place at room temperature. Protect against direct sunlight and moisture.
ENVIRONMENTAL CONDITIONS
Storage Temperature 0°F to 120°F
(-18°C to 50°C)
Operating Temperature 32°F to 110°F
(0°C to 43°C)
Storage Humidity 0% to 90%
relative humidity (non-condensing)
ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD, AND NO WARRANTIES, WHETHER EXPRESS OR IMPLIED, WILL APPLY AFTER THIS PERIOD. THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER OBLIGATIONS, LIABILITIES OR WARRANTIES. In no event shall Franklin Sensors
or its licensed distributors be liable or
responsible for INCIDENTAL OR CONSEQUENTIAL DAMAGES or for any other
direct or indirect damage, loss, cost, expense or
fee. Some states do not allow the exclusion or limitation of incidental or consequential
damages, so this exclusion or limitation may not
apply to you. This warranty gives you specic legal rights and you may also have other rights
Lath and Plaster
Irregularities in plaster thickness and variations in construction materials can make it difcult to locate studs behind lath and plaster walls. Also,
if the plaster has a mesh reinforcement, the stud
nder may not be able to detect through the metal mesh. Although many users have success with the ProSensor 710 on lath and plaster walls, there is no guarantee the ProSensor 710 will work on all lath and plaster walls.
Tile, Flooring, Roong, and on the Outside of the House
The ProSensor 710 works by measuring the
density of material behind the sensors to
determine the location of studs. Due to the variability in the density of materials in tile, ooring, roong, and on the outside of the house, we do not recommend the ProSensor
Operating Humidity 0% to 90%
relative humidity (non-condensing)
DISPOSAL
Stud nders and packaging should be sorted for recycling.
FCC PART 15 CLASS B REGISTRATION WARNING
This device complies with Part 15 of FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful
interference, and
2. This device must accept any interference
received, including interference that may cause undesired operation.
that vary from state to state.
In the event of a product defect, please return the product postage paid with proof of
purchase to:
Franklin Sensors Inc. Attn: Returns Department 13601 W. McMillan Road Suite 102 - 170 Boise, ID 83713 (208) 918-2403 returns@franklinsensors.com Hours of Operation: Monday-Friday, 8 AM to 5 PM, Mountain Time Zone
US and Foreign Patents Pending.
Rev. E1
710 for use in these applications.
TROUBLESHOOTING
TROUBLE SHOOTING
CONDITION PROBABLE CAUSE SOLUTION
No LED lights come on. Weak battery. Replace with 2 new AA alkaline batteries.
Stud nder only works momentarily. The “on” button isn’t being held down.
The LED lights are indicating the location of pipes and wires, not just studs.
Difculty starting a scan near doors and windows. Double studs, triple studs and solid headers are often
Stud nder doesn’t work through new wall paper. The moisture in the wall after wall papering can block the stud
My house was built prior to about 1960. The walls are lath and plaster. The stud nder doesn’t work very well anywhere in my house.
Inconsistent readings. Curved surface.
When I put my hand in front of the sensor board,
the readings are not what I would expect.
The LED lights sometimes seem to light up sporadically or inconsistently.
The ProSensor 710 indicates the location of inconsistencies. LED lights may indicate the location of a pipe, electrical wiring,
other objects near the surface being scanned, or an inconsistency
in the surface material or paint, etc.
around doors and windows. The stud nder requires the presence of a region without studs to correctly identify studs.
nder’s signal.
Older houses that were built with lath and plaster, instead of sheet rock, often have too much inconsistency in the walls for the detector to work reliably.
Anomaly in the surface material.
Sometimes after scanning the wall for a period of time the readings seem to be less consistent.
The stud nder is designed for detecting features in walls, not hands.
Wires, pipes, or other construction inconsistencies can cause
erratic or erroneous readings. Features on the opposite side of a wall may also be a source of inconsistent readings.
present
Hold the “on” button down until you have completed your scan.
The
Look for evenly placed studs on either side (16", 24", on center, etc.) Scan above the location and below the location to conrm results. Use caution before penetrating wall. See the SAFETY RULES FOR THE PROSENSOR 710.
Begin the scan away from the window or door, then move the stud nder to the area around the window or door. For best results, keep stud nder 3" away from wood trim, outlets, switches, etc.
Wait until the wallpaper is dry. It may take up to 2 weeks for the paper to dry sufciently.
Try using the stud nder at a higher point on the wall, or a lower point on the wall.
Press the stud nder rmly against the wall so that the contour of the sensor board matches the slight contour of the wall.
Test at a higher location, or lower location on the wall.
Release the button and press the button again.
Place the stud nder on the wall to detect hidden features.
Test at points on the wall that are higher, or lower. The stud nder may also work best if it is used more than 3 inches away from metal objects such as outlets, light switches, etc.
to assume or grant any other
Loading...