Franke Foodservice AQUA420 Installation Manual

Installation and operating instructions Montage- en bedrijfsinstructies Notice de montage et de mise en service Montaż i instrukcja obsługi
EA-Nr.: 76 12982 084157 FAR-Best.-Nr.: 5528 01 24
AQUA420
Franke Aquarotter AG
18-05.778c-Exp.fm/11.01.11
...............................................................3
Please refer to the graphics in the German Instal­lation and Operating Instructions.
...............................................................8
Les graphiques sont disponibles dans la notice de montage et de mise en service allemande.
...............................................................13
De tekeningen kunt u in de Duitse montage- en bedrijfsinstructies vinden.
...............................................................18
Prosimy przyjąć grafikę z niemieckiej instrukcji montażu i obsługi.
2

0English

Electronic Siphon Control for Stainless Steel Urinals For Concealed Installation
Please refer to the graphics in the German Installation and Operating Instructions.

1. Table of Contents

2. Abbreviations and Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4. Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5. Important Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Description of Product
6. Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
7. Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
8. Scope of Delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
9. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation, Function and Commissioning
10. Assembly Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
11. Checking the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
12. Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
13. Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Maintenance
14. Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2. Abbreviations and Units

DN Nominal diameter in mm
RCD Residual Current Protective Device,
Earth leakage circuit breaker
EA-Nr. European Article Number
18-05.778c-GB.fm
FAR-Best.-Nr. Franke Aquarotter Order Number
Conversion 1 mm = 0.03937 inches
1 inch = 25.4 mm
All length specifications in the graphics are in mm.
3

3. Key

Warning!
Failure to observe can result in injury or even death.
Caution!
Failure to observe can result in material damage.
Important!
Failure to observe can cause the product to malfunction.
Useful information for optimally handling the product.

4. Warranty

Liability is accepted according to the General Terms and Conditions of Business and Supply. Use original replacement parts only!

5. Important Notes

• Installation, commissioning and maintenance are to be performed only by a qualified technician according to the instructions provided and in accordance with legal requirements and acknowledged rules of technology.
• All technical connection regulations specified by the local water and electricity supply utility companies must be complied with.
• All rights reserved to make technical alterations.

6. Application

The electronic siphon control enables intelligent, automated and concealed triggering of the flushing process, which in turn leads to the highest achievable hygiene standard as well as economic efficiency.
The electronic siphon control is a mains-powered urinal flushing system. The start and the end of the urinating process are reliably detected.
18-05.778c-GB.fm
4

7. Technical Specifications

Minimum flow pressure: 1.0 bar
Recommended flow pressure: 1-5 bar
Maximum operating pressure: 10 bar
Calculation flow rate: 0.3 l/s
Flushing flow: 0,3–0,7 l/s
Flush water volume: 1.2–10.5 l/s adjustable
Flush duration: 4–15 s adjustable
Operating voltage: 230 V AC
Power consumption: 0.5 VA
Switch output: RPE solenoid valve, 6 V bistable
Type of protection: solenoid valve IP40
Power Supply Unit IP65 Radarsensor IP 65 Control Unit IP55

8. Scope of Delivery

Item Quantity Description
11Siphon
2 1 Radar sensor
3 1 Power supply for control unit
41Control unit
5 1 Hose connection G1/2 and G1/2
6 1 Hose connection G1/2 and G3/4
7 1 Solenoid valve with lockable water volume
82Seals
x 1 Installation and Operating Instructions
regulator

9. Dimensions

18-05.778c-GB.fm
5

10. Assembly Instructions

Warning!
Secure the electric connection with an earth leakage circuit breaker (RCD). Failure to observe can mean risk of death or material damage, e. g. from electric shock or fire.
Where improper installations lead to mutual influencing between neighbouring
urinals, this can be compensated by changing the sensitivity of the system and by additionally engaging the immunity mode (see Chapter 13.).
10.1
Connect to the water supply.
10.2
Mount the solenoid valve (d).
10.3
Check the function of the sensor (see Chapter 11.).
10.4
Use the premounted reclosable fastener hook to secure the radar sensor (a) to the siphon (b).
10.5
Connect the control unit (c) to the solenoid valve (d) and the radar sensor (a).
10.6
Connect the power supply (e) to the mains (f, 230 V AC).
10.7
Mount the urinal.
10.8
Install the siphon control unit.
10.9
Use a hollow hexagon wrench to open/close the water volume regulator. a: closed b: open
10.10
Pour at least 2 l water into the urinal.
• The first flush is triggered after 10 s.
• The system is ready.

11. Checking the Sensor

During the first 4 minutes after commissioning the radar sensor, the LED shows the
reaction of the radar sensor (flashes or lights up).
If the sensor is to be checked again, it is first necessary to disconnect the power supply
and the control unit for at least 20 s.
11.1
Connect the control unit to the power supply.
• The LED flashes 6 times short and 1 time long.
11.2
Move your hand directly in front of the radar sensor.
• The LED on the control unit lights up.
11.3
Remove your hand from the radar sensor after 5 s.
•The LED is off.
6
18-05.778c-GB.fm
• About 8 s after the end of the detected movement, the solenoid valve opens up for
Designation Order No.
1 Radar sensor . . . . . . . . . . . . . . . . . . .85-032.12.687
2 Siphon . . . . . . . . . . . . . . . . . . . . . . . .85-032.12.689
3 Solenoid valve 6 V DC . . . . . . . . . . . .85-032.01.375
4 Control unit . . . . . . . . . . . . . . . . . . . .85-032.12.686
5 Power supply . . . . . . . . . . . . . . . . . . .85-032.12.688
the flush duration.

12. Function

12.1
Using the urinal.
• Water flows shortly after the urinal has been used.
• Water flow stops automatically after a set flush duration.
The flush duration can be set within the range 4 – 15 s (see Chapter 13.).After a total flush duration of 6 s there is a 2 s interruption in the flush process to
ensure an intact odour seal.

13. Adjustments

Preliminary adjustments
Sensitivity: high Mode: normal Flush duration: 4 s
Adjusting sensitivity
S1 on: Sensitivity high S1 off: Sensitivity low
Setting the mode
S2 on: Immunity mode S2 off: Normal mode
Setting the flush duration
S3 left: Flush duration 4 s S3 right: Flush duration 15 s

14. Replacement Parts

18-05.778c-GB.fm
7

0Français

Commande électronique du siphon pour urinoirs en acier spécial pour une installation invisible
Les graphiques sont disponibles dans la notice de montage et de mise en service allemande.

1. Table des matières

2. Abréviations et unités. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3. Explication des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4. Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5. Remarques importantes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Description du produit
6. Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
7. Données techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8. Volume de livraison. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
9. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Montage, fonctionnement et mise en service
10. Montage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
11. Contrôle du détecteur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
12. Fonctionnement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
13. Réglages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Entretien
14. Pièces de rechange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

2. Abréviations et unités

DN Diamètre nominal en mm RCD Residual Current Protective Device,
interrupteur de protection contre les courants de court-circuit
EA-Nr. Numéro d’article européen FAR-Best.-Nr. Numéro de commande Franke AQUAROTTER
Conversion 1 mm = 0,03937 pouce
1 pouce = 25,4 mm
Les longueurs sont toujours indiquées en mm dans les graphiques.
8
18-05.778c-FR.fm
Loading...
+ 16 hidden pages