All length specifications in the graphics are in mm.
3
3.Key
Warning!
Failure to observe can result in injury or even death.
Caution!
Failure to observe can result in material damage.
☞ Important!
Failure to observe can cause the product to malfunction.
☞ Useful information for optimally handling the product.
4.Warranty
Liability is accepted according to the General Terms and Conditions of Business and
Supply.
Use original replacement parts only!
5.Important Notes
• Installation, commissioning and maintenance are to be performed only by a
qualified technician according to the instructions provided and in accordance with
legal requirements and acknowledged rules of technology.
• All technical connection regulations specified by the local water and electricity
supply utility companies must be complied with.
• All rights reserved to make technical alterations.
6.Application
The electronic siphon control enables intelligent, automated and concealed triggering
of the flushing process, which in turn leads to the highest achievable hygiene standard
as well as economic efficiency.
The electronic siphon control is a mains-powered urinal flushing system. The start and
the end of the urinating process are reliably detected.
18-05.778c-GB.fm
4
7.Technical Specifications
Minimum flow pressure:1.0 bar
Recommended flow pressure:1-5 bar
Maximum operating pressure:10 bar
Calculation flow rate:0.3 l/s
Flushing flow:0,3–0,7 l/s
Flush water volume:1.2–10.5 l/s adjustable
Flush duration:4–15 s adjustable
Operating voltage:230 V AC
Power consumption:0.5 VA
Switch output:RPE solenoid valve, 6 V bistable
Type of protection:solenoid valve IP40
Power Supply Unit IP65
Radarsensor IP 65
Control Unit IP55
8.Scope of Delivery
ItemQuantityDescription
11Siphon
21Radar sensor
31Power supply for control unit
41Control unit
51Hose connection G1/2 and G1/2
61Hose connection G1/2 and G3/4
71Solenoid valve with lockable water volume
82Seals
x1Installation and Operating Instructions
regulator
9.Dimensions
18-05.778c-GB.fm
5
10. Assembly Instructions
Warning!
Secure the electric connection with an earth leakage circuit breaker (RCD). Failure to
observe can mean risk of death or material damage, e. g. from electric shock or fire.
☞ Where improper installations lead to mutual influencing between neighbouring
urinals, this can be compensated by changing the sensitivity of the system and by
additionally engaging the immunity mode (see Chapter 13.).
10.1
Connect to the water supply.
10.2
Mount the solenoid valve (d).
10.3
Check the function of the sensor (see Chapter 11.).
10.4
Use the premounted reclosable fastener hook to secure the radar sensor (a) to the
siphon (b).
10.5
Connect the control unit (c) to the solenoid valve (d) and the radar sensor (a).
10.6
Connect the power supply (e) to the mains (f, 230 V AC).
10.7
Mount the urinal.
10.8
Install the siphon control unit.
10.9
Use a hollow hexagon wrench to open/close the water volume regulator.
a: closed
b: open
10.10
Pour at least 2 l water into the urinal.
• The first flush is triggered after 10 s.
• The system is ready.
11.Checking the Sensor
☞ During the first 4 minutes after commissioning the radar sensor, the LED shows the
reaction of the radar sensor (flashes or lights up).
☞ If the sensor is to be checked again, it is first necessary to disconnect the power supply
and the control unit for at least 20 s.
11.1
Connect the control unit to the power supply.
• The LED flashes 6 times short and 1 time long.
11.2
Move your hand directly in front of the radar sensor.
• The LED on the control unit lights up.
11.3
Remove your hand from the radar sensor after 5 s.
•The LED is off.
6
18-05.778c-GB.fm
• About 8 s after the end of the detected movement, the solenoid valve opens up for
• Water flows shortly after the urinal has been used.
• Water flow stops automatically after a set flush duration.
☞ The flush duration can be set within the range 4 – 15 s (see Chapter 13.).
☞ After a total flush duration of 6 s there is a 2 s interruption in the flush process to
ensure an intact odour seal.
13. Adjustments
Preliminary adjustments
Sensitivity: high
Mode: normal
Flush duration: 4 s
Adjusting sensitivity
S1 on: Sensitivity high
S1 off: Sensitivity low
Setting the mode
S2 on: Immunity mode
S2 off: Normal mode
Setting the flush duration
S3 left: Flush duration 4 s
S3 right: Flush duration 15 s
14. Replacement Parts
18-05.778c-GB.fm
7
0Français
Commande électronique du siphon pour urinoirs en acier spécial
pour une installation invisible
Les graphiques sont disponibles dans la notice de montage et de mise en service
allemande.