EA-Nr.European Article Number
FAR-Best.-Nr.Franke-Aquarotter Order No.
Conversion1 mm = 0.03937 inches
All length specifications in the graphics are in mm.
2.Key
1inch = 25.4mm
Warning!
Failure to observe can result in injury or even death.
Caution!
Failure to observe can result in material damage.
☞ Important!
Failure to observe can cause the product to malfunction.
☞ Useful information for optimally handling the product.
3.Warranty
Liability is accepted according to the General Terms and Conditions of Business and
Supply.
Use original replacement parts only!
4.Important Notes
• Installation, commissioning and maintenance are to be performed only by a
qualified technician according to the instructions provided and in accordance with
legal requirements and acknowledged rules of technology.
• All technical connection regulations specified by the local water and electricity
supply utility companies must be complied with.
• All rights reserved to make technical alterations.
4
18-05.360a-GB.fm
5.Application
Wall spigot DN 15 with theft-proof aerator.
For application in shower rooms in public or commercial environments, for fixed
installation.
6.Technical Specifications
Minimum flow pressure:1.0 bar
Recommended flow pressure:1–5 bar
Maximum operating pressure:10 bar
Calculation flow rate:0.10 l/s
Volumetric flow:0.10 l/s for 3 bar flow pressure
7.Scope of Delivery
8.Dimensions
9.Installation Example
10. Assembly Instructions
10.1
Screw-in the G1/2B connection spigot leak-tight using an open-jaw wrench.
10.2
Slide the wall arm onto the connection spigot.
10.3
Screw-in the grub screw using a hollow hexagon wrench.
10.4
Slide the headpiece on to the wall arm.
10.5
Screw-in the grub screw using a hollow hexagon wrench.
18-05.360a-GB.fm
5
11.Maintenance and Servicing
Depending on the quality of the water, the local conditions and the rules and
regulations applicable on site, the fitting must be maintained and serviced at regular
intervals.
Perform maintenance on the following components:
•Aerators
• Flow rate regulator
Use suitable cleaning agents that are not harmful to the fittings in a proper manner and
rinse with water after use. High-pressure cleaners must not be used for cleaning.
12. Replacing the Flow Rate Regulator
12.1
Loosen the grub screw using a hollow hexagon wrench.
12.2
Pull the wall arm with the head piece from the connection spigot.
12.3
Remove the safety ring with the appropriate pliers for the inner safety rings.
12.4
Pull out the flow rate controller with flat nose pliers.
☞ Important!
Ensure correct installation orientation of the flow rate regulator. The brace must face in
the direction of the head piece.
12.5
Insert the flow rate regulator and secure with the circlip.
a: Brace
b: Flow direction
12.6
Slide the wall arm with the head piece onto the connection spigot.
12.7
Tighten the grub screw using a hollow hexagon wrench.
13. Replacing an Aerator
13.1
Use the special wrench (a) to loosen the complete aerator.
13.2
Remove the complete aerator from the head piece (b).