2.Important Notes
• Installation, commissioning and maintenance are to be performed only by a
qualified technician according to the instructions provided and in accordance with
legal requirements and acknowledged rules of technology.
• All technical connection regulations specified by the local water and electricity
supply utility companies must be complied with.
• Before assembling and installing the pipes, flush in accordance with DIN 1988.
• Suitable cleaning agents that do not corrode the fittings are to be used as directed
and then completely removed.
• All rights reserved to make technical alterations.
18-05.078e-GB.fm
3
3.Application
AQUALINE self-closing straight-way valve DN 15 for shower systems and washing
bays for wall installation with sound-absorbent polystyrene insulation. For
connecting to pre-mixed warm water or cold water supply. Adjustable flow duration.
4.Technical Specifications
Minimum flow pressure:1.0 bar
Calculation flow rate:0.20 l/s
Volumetric flow:0.40 l/s at a flow pressure of 3 bar (open
outlet)
Flow time at 38 °C:1 - 50 s adjustable
(with shower head, 0.20 l/s at 3 bar flow
pressure)
5.Scope of Delivery
Quantity Description
1Installation and Operating Instructions
1AQUALINE self-closing straight-way valve
in 2 polystyrene half shells
1Red marking ring on the fitting
1Accompanying blue marking ring
1Slide-on rosette
6.Dimensions
Only with 2195 21 23
Caution!
Do not insert the fitting too deeply into the wall. An adjustment is not possible.
7.Installation Example
4
18-05.078e-GB.fm
8.Assembly Instructions
8.1
Push the fitting in the wall niche provided and connect the water supply.
Check the direction of flow.
a:Flow direction
8.2
After tiling, cut the part of both polystyrene half shells sticking out of the wall with a
knife to the height of the front edge of tiles.
☞ Do not cut too deeply into the polystyrene half shells as otherwise you may damage
the fitting.
8.3
Break both polystyrene half shells with your hand.
8.4
Put on the slide on rosette.
9.Function
Triggering water flow
9.1
Press the push-cap.
• Water flows.
• Water flow stops automatically after a set flow duration.
☞ The flow time can be set in the range 1 - 50 s.
10. Adjusting the Flow Duration
10.1
Set the required mixed water temperature.
10.2
Remove the cover platelet.
a: Blade width 3 mm
10.3
Set the flow duration with a screwdriver.
a: Blade width 3 mm
+ longer flow duration (max. 50 s)
– shorter flow duration (min. 1 s)
10.4
Trigger the valve to measure the flow duration.
10.5
Put on the cover plate after setting the required flow time.