TO PREVENT ELECTRIC SHOCK, MATCH
WIDE BLADE OF PLUG TO WIDE SLOT,
FULLY INSERT.
HF POWER TWEETER
WOOFERLF POWER
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightening flash with arrowhead symbol,
within an equilateral triangle, is intended to
alert the user to the presence of uninsulated
“dangerous voltage” within the product's enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
“WARNING”
“TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.”
SAFETY INSTRUCTIONS
Read instructions - All the safety and operating instruc-
1.
tions should be read before the appliance is operated.
Retain instructions - The safety and operating instructions
2.
should be retained for future reference.
Heed warnings - All warnings on the appliance and in the
3.
operating instructions should be adhered to.
Follow instructions - All operating and use instructions
4.
should be followed.
Water and Moisture - The appliance should not be used
5.
near water - for example, near a bathtub, washbowl,
kitchen sink, laundry tub, in a wet basement, or near a
swimming pool, and the like.
Carts and Stands - The appliance should be used only
6.
with a cart or stand that is recommended by the manufacturer.
An appliance and cart combination should be moved with
care. Quick stops, excessive force, and uneven surfaces
may cause the appliance and cart combination to overturn.
Wall or Ceiling Mounting - The appliance should be
7.
mounted to a wall or ceiling only as recommended by the
manufacturer.
Ventilation - The appliance should be situated so that its
8.
location or position does not interfere with its proper ventilation. For example, the appliance should not be situated on a bed, sofa, rug, or similar surface that may block
the ventilation openings; or, placed in a built-in installation, such as a bookcase or cabinet that may impede the
flow of air through the ventilation openings.
ATTENTION:
POUR ÉVITER LES CHOCS ÉLECTRIQUES,
INTRODUIRE LA LAME LA PLUS LARGE DE
LA FICHE DANS LA BORNE CORRESPONDANTE DE LA PRISE ET POUSSER
JUSQU' AU FOND.
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and maintenance (servicing) instructions in the literature
accompanying the appliance.
Heat - The appliance should be situated away from heat
9.
sources such as radiators, heat registers, stoves, or other
appliances (including amplifiers) that produce heat.
Power Sources - The appliance should be connected to a
10.
power supply only of the type described in the operating
instructions or as marked on the appliance.
Grounding or Polarization - The precautions that should
11.
be taken so that the grounding or polarization means of
an appliance is not defeated.
Power Cord Protection - Power supply cords should be
12.
routed so that they are not likely to be walked on or
pinched by items placed upon or against them, paying
particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance.
Cleaning - The appliance should be cleaned only as rec-
13.
ommended by the manufacturer.
Nonuse Periods - The power cord of the appliance should
14.
be unplugged from the outlet when left unused for a long
period of time.
Object and Liquid Entry - Care should be taken so that
15.
objects do not fall and liquids are not spilled into the enclosure through openings.
Damage requiring Service - The appliance should be ser-
16.
viced by qualified service personnel when:
The power supply cord or the plug has been damaged;
A.
or
Objects have fallen, or liquid has been spilled into the
B.
appliance; or
The appliance has been exposed to rain; or
C.
The appliance does not appear to operate normally or
D.
exhibits a marked changed in performance; or
The appliance has been dropped, or the enclosure
E.
damaged.
Servicing - The user should not attempt to service the ap-
17.
pliance beyond that described in the operating instructions. All other servicing should be referred to qualified
service personnel.
DIP: Dual In Line
H:Horizontal mount
ZIP: Zigzag in-line package
SIP: Single in-line package
V:Vertical mount
T:Taping device
P:Penetrate mount
I:I form (straight)
L:L form (right angle)
DG: Digital
AN: Analogue
NF-1A
Speakers
Enclosure system2-way bass-reflex system
Drivers160 mm HP woofer x 1 (low-leakage type)
20 mm Soft-Dome tweeter x 1 (low-leakage type)
Impedance8 Ω
Reproduction Frequency Response50 Hz ~ 40 kHz
Enclosure volume9.2 liters
Maximum output sound level106 dB (with VOL max./rated input)
Amplifiers
Output power60 W each for low and high frequency amplifiers
Tweeter SPL adjustable level± 3 dB
Filter characteristic adjustable level
HI-FREQ (10 kHz)+ 3 / 0 / - 3 dB (selective)
LO-FREQ (60 Hz)+ 3 / 0 / - 3 dB (selective)
HI-MID ATT. (3 kHz)0 dB when switched off.
- 3 dB when switched on.
Input terminalsXLR-3-31 type (for balanced input)
∅6 mm phone jack (for unbalanced input)
Normal input level+4 dBu (XLR balanced input)
-10 dBV (phone unbalanced input)
Input impedance20 kΩ or more
Crossover frequency5 kHz
Others
WeightApprox. 11 kg
Power supply120 V AC, 60 Hz
230 V AC, 50 Hz
Power consumption52 W
Specifications and physical appearance are subject to change without notice for product improvement.
165
Page 6
NF-1 & NF-1ANF-1 & NF-1A
2. CONTROLS, INDICATORS & CONNECTORS
NF-1A
1. Power LED
2. Heat sink
3. Loudness control [
VOL, -∞ ~ MAX (0dB)
4. Tweeter level control
[
TWEETER LEVEL, -3 ~ 0dB ~ +3
5. Hi-Mid attenuator [
HI-MID ATT., ON / OFF
6. High-frequency filter selector
[
HI-FREQ, +3dB / 0 / -3
]
+3dB
0dB
-3dB
60Hz
]
]
]
+3dB
0dB
-3dB
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUEELECTRIQUECHOCDE
AVIS:
NE PAS OUVRIR.
WARNING:
TO
REDUCETHE RISKOF FIREORELECTRIC
SHOCK,DO NOT EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE.
0dB
-3dB
HI-MID ATT.HI FREQLO FREQ
7. Low-frequency filter selector
[
LO-FREQ, +3dB / 0 / -3
8. Unbalanced input terminal
[
INPUT, UNBAL -10dBV (phone jack)
9. Balanced input terminal
[
INPUT, BAL +4dBu (XLR)
10. Power switch [
11. AC IN connector [
MAX
(0dB)
-3
+3
1:G
2:H
3:C
3k1k 5kHz10kHz
ON
OFF
+3dB
0
-3
+3dB
0
-3
TWEETER
0dB
HI-MID ATT.
LO FREQ
POWER
POWER
VOL
LEVEL
HI FREQ
INPUT
UNBAL
-10dBV
BAL
+4dBu
ON
OFF
AC IN
AC IN
NF-1A PCB Assy Parts List
• POWER AMP PCB assy
Ref. No.Part No.Description
]
]
]
]
]
Ref. No.Part No.Description
U0018236 0781 01 PT, DG, driver, DTC114ES
U5018236 0361 00 PT, SIP, AN, op amp, BA4560N
U5028236 0466 00 HZIP, AN, power amp, LM3886TF
U5108236 0466 00 HZIP, AN, power amp, LM3886TF
8274 2700 00 PCB Assy, Power Amp, NF-1A
8251 9930 01 Plain PCB, Power Amp, NF-1A