Follett U300 Installation Manual

Installation Manual
Service Numbers Below B22204
U300/UD300 Series Ice
and Beverage Dispensers
208601R01
801 Church Lane • PO Box D, Easton, PA 18044, USA Toll free (800) 523-9361 • (888) 2-FOLLETT (610) 252-7301 • Fax (610) 250-0696 • www.follettice.com
Model U300B
Model U300R400A/W
Model U300BR400A/W
Model U300R800A/W
Model U300BR800A/W
Model UD300
Model UD300R400A/W Model UD300R800A/W
Single-sided dispensers
Dual-sided dispensers
Order parts online www.follettice.com
Welcome to Follett
Follett ice dispensers enjoy a well-deserved reputation for excellent performance, long-term reliability and outstanding after-the-sale support. To ensure that this dispenser delivers that same degree of service, we ask that you take a moment to review this manual before beginning installation of the dispenser.
Should you have any questions or require technical assistance at any point, please call our technical service group toll free at (800) 523-9361 or (888) 2-FOLLETT or (610) 252-7301.
Before you begin
• After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If damage is found, notify the shipper immediately and contact Follett Corporation so that we can help in filing a claim, if necessary.
• Check your paperwork to determine which model you have. Follett model numbers are designed to provide information about the type and capacity of Follett ice dispensing equipment. Following is an explanation of the different model numbers.
U300BR400A
Condenser type – A = air-cooled, W = water-cooled
Remote icemaker(s) capacity and refrigerant – 400 = 400 lbs (181kg)/day, R404A
800 = 800 lbs (363kg)/day, R404A absence of = manual fill unit
B = beverage bath equipped. Absence of a B = no integral beverage cooling
Approximate manual load storage capacity in lbs
Dispenser configuration – U = undercounter, UD = undercounter dual-sided
Important cautions
• Storage area of dispenser contains mechanical, moving parts. Keep hands and arms clear of this
area at all times. If access to this area is required, power to unit must first be disconnected.
• Follett manual load dispensers can accommodate most cube/cubelet ices up to 1" square and
compressed nugget ice. Nugget, crushed, flake, bagged or congealed ice cannot be used. Use of these ices can jam dispenser and void warranty. Separate any “waffle-like” sections of cubes before adding to dispenser. For ice compatibility questions, please call Follett customer service at (800) 523-9361 or (888) 2-FOLLETT or (610) 252-7301.
• Follett recommends use of an activated carbon filter for units equipped with icemakers
• Ice is slippery. Maintain counters and floors around dispenser in a clean and ice-free condition.
• Ice is food. Follow recommended cleaning instructions to maintain cleanliness of delivered ice.
!
Electrical specifications – 115V, 60Hz, 1 phase
• Maximum fuse size 15 amps, each circuit all models
• Equipment ground required
• Electric disconnect suggested within 10 ft (3m) of dispenser and icemaker(s)
Single-sided dispensers
U300 – dispenser 6.0 amps U300B – dispenser 7.0 amps U300R400A/W – dispenser 6.0 amps, icemaker 11.0 amps U300BR400A/W – dispenser 7.0 amps, icemaker 11.0 amps U300R800A/W – dispenser 6.0 amps, icemakers 11.0 amps each U300BR800A/W – dispenser 7.0 amps, icemakers 11.0 amps each
Dual-sided dispensers
UD300 – dispenser 8.0 amps UD300R400A/W – dispenser 8.0 amps, icemaker 11.0 amps UD300R800A/W – dispenser 8.0 amps, icemakers 11.0 amps each
Plumbing
Caution: Do not reduce size of drain lines or tie drains together. Dispenser 3/4" slip fit PVC bin drain
1" PVC slip fit drain pan drain(s) 1" PVC slip fit beverage bath drain (units with beverage cooling)
Note: Drains should be hard piped and insulated. Maintain at least 1/4" per foot slope
(6mm per 304mm run) on drain line run.
Icemaker Refer to Icemaker Installation Manual packed with icemaker for installation instructions
1/4" FPT water in 1/2" MPT drain 3/8" FPT condenser inlet (water-cooled condenser only) 1/2" FPT condenser drain (water-cooled condenser only)
Note: Water disconnect within 10 ft (3m) of dispenser is suggested for auto load units.
Beverage connections
Dispenser type Syrup lines Carbonator manifold Plain water lines
Single-sided models 1/4" barb 3/8" barb 1/4" barb Dual-sided models Pigtail connections provided at base of dispenser
1/4" hose 3/8" hose 1/4" hose
2
On all models with remote icemaker(s), black wire on icemaker control board LINE VAC terminal must be moved to 24V terminal.
Front view
Side view
U300 series single-sided dispensers
m
3
Required clearances
• 60" (1524mm) above counter for installation if dispenser will be dropped into counter
• 49" (1245mm) above counter for all units after installation for auger cleaning and servicing
• 12" (305mm) on dispense chute side of all models for connections
• 12" (305mm) on side opposite dispense chute if ice transport tube enters side opposite chute
40.875 (1039mm)
17" (432mm)
one icemaker – models U300R400A/W U300BR400A/W
two icemakers – models U300R800A/W U300BR800A/W
18.875" (480mm)
6" min (153mm)
entrance beverage lines
12" min (305mm)
electric conn.
disp. drains
ice waterbath (U300BR400A/W, U300BR800A/W, U300B only)
ICE
22" (559mm)
32.375" (823mm)
25.25" (642mm)
54.875" (1394mm)
29.625" (753mm)
beverage lines enter through bottom
junction boxes
7" (178mm)
3" (77mm)
10" (254mm)
2.5" (64mm)
9" (229mm)
1" (26mm) drains
3/4" (19mm) drain
30" (762mm)
9" (229mm)
15" (381mm)
ice transport tube entry
8.5" (216mm)
2" (51mm)
27.5" (699m