Follett U155N Parts List

Order parts online www.follettice.com
U155N Series
Ice and Water Dispensers
Installation, Operation and Service Manual
Manual load units Automatic load units
with one icemaker
Automatic load units
with two icemakers
Following installation, please forward this manual
801 Church Lane • Easton, PA 18040, USA Toll free (800) 523-9361 • (610) 252-7301 Fax (610) 250-0696 • www.follettice.com
208599R01
Contents
Welcome to Follett. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Before you begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Field wiring diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installing dispenser in counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installing remote icemaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Cleaning Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Disassembly for cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Disassembly for service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Dispenser troubleshooting guide . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Replacement parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Dispenser exterior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Dispense assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Hopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Auger motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Electrical components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Welcome to Follett
Follett ice and water dispensers enjoy a well-deserved reputation for excellent performance, long-term reliability and outstanding after-the-sale support. To ensure that this dispenser delivers that same degree of service, we ask that you take a moment to review this manual before beginning the installation of the dispenser. Should you have any questions or require technical help at any point, please call our technical service group toll free at (800) 523-9361 or (610) 252-7301.
Before you begin
• After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If damage is found, notify the shipper immediately and contact Follett Corporation so that we can help in the filing of a claim, if necessary.
• Check your paperwork to determine which model you have. Follett model numbers are designed to provide information about the type and capacity of Follett ice dispensing equipment. Following is an explanation of the different model numbers in the U155 series.
U155NR400AR
Ice dispense chute location – R = right side, L = left side
Condenser type – A = air-cooled, W = water-cooled
Remote icemaker(s) capacity and refrigerant – 400 = 400 lbs (181kg)/day, R404A 800 = 800 lbs (363kg)/day, R404A absence of = manual fill unit
N = ice and water only, no beverage rail or valves
Approximate storage capacity in lbs
Dispenser configuration – U = undercounter
Important cautions
• Storage area of dispenser contains mechanical, moving parts. Keep hands and arms clear of this area at all times. If access to this area is required, power to unit must be disconnected first.
• Follett manual load dispensers can accommodate most cube/cubelet ices up to 1" square, or Follett compressed nugget ice. Crushed, flake, bagged, nugget or congealed ice cannot be used. Use of these ices can jam dispenser and void warranty. Separate any “waffle-like” sections of cubes before adding to dispenser. For ice compatibility questions, please call Follett customer service toll free at (800) 523-9361 or (610) 252-7301.
Follett recommends use of an activated carbon filter for units equipped with icemakers.
• Ice is slippery. Maintain counters and floors around dispenser in a clean and ice-free condition.
• Ice is food. Follow recommended cleaning instructions to maintain cleanliness of delivered ice.
Specifications
Electrical
Each icemaker and dispenser requires separate circuit with electrical disconnect within 10 feet (6m). Equipment ground required. Standard electrical - 115V, 60Hz, 1 phase. Max. fuse dispenser – 15 amps; each
icemaker – 20 amps
Model Icemaker Dispenser number amperage amperage
U155N - - 2.4 amps U155NR400A/W 11.0 amps 2.4 amps U155NR800A/W 11.0 amps ea (2) 2.4 amps
3
Plumbing
Dispenser 3/4" PVC slip joint for hopper drain
3/4" PVC pipe nipple for beverage drain pan 3/8" ID red line tubing for water in
304mm run) slope on drain line run.
Icemaker Refer to Icemaker Installation Manual packed with icemaker
1/4" FPT water in 1/2" MPT drain 3/8" FPT condenser inlet (water-cooled condenser only) 1/2" FPT condenser drain (water-cooled condenser only) Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.
Note: Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per
Clearance and access information
• 51" (1296mm) above counter
• 12" (305mm) on side opposite tower, below counter
• Counter front or rear panel must be removable for service access to both sides of dispenser and icemaker(s), if any
• Below counter access to drain clean-out required on utility side of dispenser
Side view - right hand dispenser
(side opposite dispense tower)
27.375"
(696mm)
12"
(305mm)
ice transport tube entrance
3.5"
(89mm)
26"
(661mm)
plain water connection
air break:
do not connect to drain system
26"
(661mm)
3/4" PVC slip joint drain
5.25"
(134mm)
two remote icemakers models U155NR800A/W
17" (432mm)
Front view
one remote icemaker models U155NR400A/W
18.875" (480mm)
6" min (153mm)
12" min (305mm)
plain water
electric conn.
and drain clean-out
Automatic load units with 1 icemaker
Automatic load units with 2 icemakers
31.25
(794mm)
Manual load units
12"
(305mm)
21.75"
"
(553mm)
49.75" (1264mm)
28" (712mm)
4
Electrical hookup information
Model
U155N
U155NR400A/W
U155NR800A/W
Electrical Connection
Hard-wiring of dispenser required.
Dispenser power – hard wiring required.
Bin signal – cord and plug supplied.
Icemaker – cord and plug supplied on power and bin signal.
Dispenser power – hard wiring required.
Circuit(s) required
115V, 60Hz, 1 phase Max. fuse dispenser – 15 amps.
115V, 60Hz, 1 phase (2) circuits required
Dispenser – 15 amps max. fuse size.
Icemaker – 20 amps max. fuse size.
115V, 60Hz, 1 phase (3) circuits required
Dispenser – 15 amps max. fuse size.
Bin signal – cord and plug supplied.
Icemaker – cord and plug supplied on power and bin signal.
(2) icemakers – 20 amps max. fuse size each.
Note: equipment must be wired according to local and NEC codes.
Attention – Should local codes require a hard-wired connection and/or shielded wiring,
!
eliminate the cord(s) and plug(s) and follow the appropriate field wiring diagram on the following page.
See icemaker Installation and Operation manual for recommended junction box preparation of
hard-wired remote icemaker(s).
5
Field wiring diagrams
Manual load units
IMPORTANT
Field wiring diagram is intended to aid electrician or technician in understanding how equipment works. All field wiring must be installed in accordance with NEC and local electrical codes.
LEGEND
Wirenut field connections Equipment
X
ground
BL - black
W - white
GRN - green
Automatic load units
Electric power source
(115 volts)
GND
GRN
BL W
X
Standard electrical - 115V, 1 Ph, 60Hz, max. fuse size 15 amps
U155 dispenser
15 amp fused disconnect
Left junction box
GND GRN
W
BL
Right junction box
BL
Y
NOT USED
R
Field wiring diagram is intended to aid electrician or technician in understanding how equipment works. All field wiring must be installed in accordance with NEC and local electrical codes.
IMPORTANT
Electric power source
(115 volts)
BL W
GND
X
GRN
15 amp fused disconnect
Standard electrical - 115V, 1 Ph, 60Hz, max. fuse size 15 amps
U155 dispenser
Left junction box
W
GND GRN
(115 volts) (24 volts)
On all models with remote icemaker(s), the black wire on the icemaker control board’s(s’) LINE VAC terminal must be moved to the 24V terminal.
Right junction box
BL
LEGEND
Wirenut field connections
Equipment
X
ground
GND - ground BL - black
W - white GRN - green B - blue R - red
Y - yellow
B
Y
R
Icemaker #1
Lower junction box
BL
W
(24 volts)
Icemaker #2 (optional)
Lower junction box
W
BL
(24 volts)
(115 volts)
Electric power source
GND
BL W
GRN
X
15 amp fused disconnect
BL W
GND
X
GRN
15 amp fused disconnect
Upper junction box
W
BL
GRN
X
GND
Upper junction box
GND
BL
GRN
X
W
6