Follett HCE1400A, HCE1400W User Manual

HCE1400A, HCE1400W 50Hz Icemakers
Operation and Service Manual
After Serial Number C20000
Following installation, please forward this manual
to the appropriate operations person.
801 Church Lane • Easton, PA 18040, USA Toll free (800) 523-9361 • (610) 252-7301 Fax (610) 250-0696 • www.follettice.com
00171611R00
Follett Corporation Equipment Return Policy
Follett equipment may be returned for credit under the following conditions:
1. The equipment is new and unused.
2. A return authorization number has been issued by customer service within 30 days after shipment.
3. Follett receives the equipment at the factory in Easton, PA within 30 days after issuance of the return authorization number.
4. The equipment must be returned in Follett packaging. If the packaging has been damaged or discarded, Follett will forward, at the customer’s expense, new packaging.
Note: Return freight charges are the responsibility of the customer. If equipment is returned and is damaged because of
improper packaging, Follett Corporation will not be held responsible.
Credit will be issued when: The equipment has been inspected by Follett and deemed suitable to be returned to stock.
Note: A 15% restocking charge will be deducted from the credit. If the cost to return the product to stock exceeds 15%, the
actual cost will be deducted.
2
Table of contents
Welcome to Follett Corporation Specifications Operation
Cleaning Weekly exterior care Monthly condenser cleaning
Semi-annual evaporator cleaning
Service
Icemaker operation Water system Electrical system Normal control board operation Test points Time delay and self flushing jumpers Error faults Hard error Soft errors Relay output indication Compressor/refrigerant solenoid output Wiring diagram Compressor data Gearmotor data Resistance of windings Mechanical system Evaporator disassembly Evaporator reassembly Refrigeration system Refrigeration pressure data Refrigeration system diagram Refrigerant charge size Refrigerant replacement requirements Evacuation Ambients Ice capacity test Bin full detection system Troubleshooting Replacement parts
4 5 7 7 7 7
7 12 12 13 14 14 15 15 15 15 15 15 15 16 17 17 17 18 18 20 23 23 23 24 24 24 24 24 25 26 28
3
Welcome to Follett
Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and outstanding after-the-sale support. To ensure that this equipment delivers the same degree of service, we ask that you review the installation manual (provided as a separate document) before beginning to install the unit. Our instructions are designed to help you achieve a trouble-free installation. Should you have any questions or require technical help at any time, please call our technical service group at (800) 523-9361 or (610) 252-7301.
Before you begin
After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If damage is found, notify the shipper immediately and contact Follett Corporation so that we can help in the filing of a claim, if necessary.
Check your paperwork to determine which model you have. Follett model numbers are designed to provide information about the type and capacity of Follett equipment. Following is an explanation of the different model numbers in the 1400 series.
Horizon Series Icemaker Model Number Configurations
ATSE 1400HC
Icemaker Voltage Series Condenser
HC Horizon Chewblet
Chewblet is a registered trademark of Follett Corporation, registered in the US.
E 230/50/1
®
(self-contained only)
1000 up to 1036 lbs (471kg)
1400 up to 1450 lbs
(658kg)
A Air-cooled, self-contained W Water-cooled, self-contained
Application Configuration
H Harmony™ B Ice storage bin
S Satellite-fill™ T Top-mount
CAUTION
• Warranty does not cover exterior or outside installations
• Moving parts. Do not operate with front cover removed.
• Hot parts. Do not operate with cover removed.
• To reduce risk of shock, disconnect power before servicing
• Most ice machine cleaners contain citric or phosphoric acid, which can cause skin irritation. Read caution label on product and follow instructions carefully.
• Ice is slippery. Maintain counters and floors around dispenser in a clean and ice-free condition.
• Ice is food. Follow recommended cleaning instructions to maintain cleanliness of delivered ice.
4
Specifications
Electrical
Each icemaker requires its own separate circuit with electrical disconnect within 10 ft (6m). Equipment ground required. Standard electrical – 220-240/50/1 Maximum icemaker fuse – 20 amps Amperage – 16 amps Maximum power – 5280 watts Climatic class – N 6 ft (2m) cord provided on icemaker
CAUTION
• Plug must be provided by the end-user and must conform to standard EN 60 335-2-24:2003 of the end
destination
• If the supply cord is damaged, it must be replaced by the manufacturer or their service agent, or a similarly
qualified technician in order to avoid a hazard
Plumbing
3/8" OD push-in water inlet 3/4" MPT drain 1/4" FPT condenser inlet (water-cooled condenser only) 1/4" FPT condenser drain (water-cooled condenser only)
Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run). Drain to be hard piped and insulated. To prevent back flow, do not connect drains. Separate drains for icemaker and condenser. Water shut-off recommended within 10 feet (3m). Follett recommends installation of Follett model 00130286 activated carbon filter in icemaker inlet water line.
Ambient
Air temperature 100˚F/38˚C max. 50˚F/10˚C min. Water temperature 90˚F/32˚C max. 45˚F/7˚C min. Water pressure – potable 70 psi max. (483 kPa) 10 psi min. (69 kPa)
Note: Water-cooled condenser pressure 150 psi max (1034kPa); 10 psi min (69kPa)
Heat rejection
Air-cooled rejects 15,500 BTU/hr to air (3906Kcal/hr) to air Water-cooled rejects 15,500 BTU/hr to water (3906Kcal/hr) to water
Ice production
Air-cooled icemaker capacity/24 hrs.
Ambient Air Temperature F/C
60
70
80
90 32
1105
502
1033
469
969 440
891 405 820 372
100
989 449 917 416 847 385 776 352 714 324
38
Inlet Water Temperature F/C
F
16
21
1290
586
1206
548
1136
516
1065
484 993 451
27
1192
541
1120
509
1050
477 919 417 907 412
C
1362
50
618
10
1290
60
586
16
1219
70
553
21
1148
80
521
27
1077
90
489
32
Water-cooled icemaker capacity/24 hrs.
Ambient Air Temperature F/C
50
60
F
10
16
C
1128
1128
512
1081
491
1035
470 989 449 943 428
1128
1081
1035
Inlet Water Temperature F/C
50
512
10
1081
60
491
16
1035
70
470
21
989
80
449
27
943
90
428
32
lbs kg lbs kg lbs kg lbs kg lbs kg
512
491
470 989 449 943 428
70
80 27
1128
512
1081
491
1035
470 989 449 943 428
90 32
1128
512
1081
491
1035
470
989 449 943 428
lbs kg lbs kg lbs kg lbs kg lbs kg
21
5
Dimensions and clearances
Entire front of icemaker must be clear of obstructions/connections to allow removal.
1" (26mm) clearance above icemaker for service.
1" (26mm) minimum clearance on sides.
The intake and exhaust air grilles must provide at least 170 sq in (1098 sq cm) of open area.
Air-cooled model HCC1400A icemakers – 18" (458mm) minimum clearance between discharge and air intake-grilles.
Keep ventilation openings in the appliance enclosure or built-in structure, clear of obstruction.
CAUTION
• Keep ventilation openings in the appliance enclosure or built-in structure, clear of obstruction
Front View Side View Back View
Air exhaust
29.63" (753mm)
21.28" (541mm)
Ice transport hose connection
Air exhaust both sides
Cord only
Air intake
23.50"
(597mm)
Stock Module Identification Plate Module No.
Product
Service No.
208264
Easton Pennsylvania
CORPORATION
PART NO
SERIAL NO
MODEL
SINGLE
FULL LOAD AMPS
HZ
VOLTS
PHASE
MOTOR COMPRESSOR THERMALLY PROTECTED
OZ
REFRIGERANT
CHARGE
PSIG
DESIGN PRESSURE HIGH SIDE
LOW SIDE
MIN. BRANCH CIRCUIT AMPACITY
AMPS
MADE IN
ULU
NSF
THE USA
L
RR
MAX. BRANCH CIRCUIT FUSE SIZE
AMPS
C
21.05" (535mm)
23.77" (604mm)
15.56"
(396mm)
6.95"
(177mm)
1/4" FPT condensor drain (water-cooled only)
1/4" FPT condensor inlet (water-cooled only)
2.53"
(65mm)
2.43" (62mm)
3/4" MPT drain
3/8" OD push-in water inlet
6
Operation
Cleaning and preventive maintenance (all models)
Note: Do not use bleach to sanitize or clean the icemaker.
Preventive maintenance
Periodic cleaning of Follett’s icemaker system is required to ensure peak performance and delivery of clean, sanitary ice. The recommended cleaning procedures that follow should be performed at least as frequently as recommended, and more often if environmental conditions dictate.
Cleaning of the condenser can usually be performed by facility personnel. Cleaning of the icemaker system, in most cases, should be performed by your facility’s maintenance staff or a Follett authorized service agent. Regardless of who performs the cleaning, it is the operator’s responsibility to see that this cleaning is performed according to the schedule below. Service problems resulting from lack of preventive maintenance will not be covered under the Follett warranty.
Weekly exterior care
The exterior may be cleaned with a stainless cleaner such as 3M Stainless Steel Cleaner & Polish or equivalent.
Monthly condenser cleaning (air-cooled icemaker only)
1. Use a vacuum cleaner or stiff brush to carefully clean condenser coils of air-cooled icemakers to ensure optimal performance.
2. When reinstalling counter panels in front of remote icemakers, be sure that ventilation louvers line up with condenser air duct.
Semi-annual evaporator cleaning (every 6 months)
WARNING
• Wear rubber gloves and safety goggles (and/or face shield) when handling ice machine cleaner or sanitizer
CAUTION
• Use only Follett approved SafeCLEAN™ Cleaner (part #00132001) and NU-CALGON IMS-II SANITIZER
• Do not mix Cleaner and Sanitizer solutions together
• DO NOT USE BLEACH
• It is a violation of Federal law to use these solutions in a manner inconsistent with their labeling
• Read and understand all labels printed on packaging before use
Note: Complete procedure for cleaning an sanitizing MUST be followed. Ice must be collected for 10 minutes before putting ice machine back into service.
1. To clean – Remove cover. Press the CLEAN button. The machine will drain. Wait for the LO
WATER light to come on (Fig. 1).
Fig. 1
LO WATER
C
L
E
A
N
7
2. Mix 1 gallon (3.8L) 120˚F (49˚C) water and
7 ounces (198g) (one 7 ounce packet of Follett SafeCLEAN ice machine cleaner, part# 00132001). Locate cleaning cup. Fill until HI WATER light comes on (Fig. 2). Note: Do not use bleach to sanitize or clean the icemaker.
3. Replace cover on cleaning cup. Wait until machine restarts. Machine will clean, then flush 3 times in approximately 12 minutes (Fig. 3).
Fig. 2
HI WATER
Fig. 3
4. To sanitize – Press CLEAN button. The machine will drain. Wait for LO WATER light to come on (Fig. 4).
Fig. 4
12
LO WATER
C
L
E
A
N
8
5. Mix 1 gallon 120˚F (49˚C) water and 1.6 ounces (48ml) NU-CALGON IMS-II SANITIZER. Fill until HI WATER light comes on (Fig. 5). Note: Do not use bleach to sanitize or clean the icemaker.
6. Replace cover on cleaning cup. Wait until machine restarts. Machine will sanitize, then flush 3 times in approximately 12 minutes (Fig. 6).
Fig. 5
HI WATER
Fig. 6
7. To clean transport tube – Press power switch OFF (Fig. 7).
12
Fig. 7
9
8. Disconnect coupling as shown (Fig. 8).
Fig. 8
9. Using disposable food service grade gloves, insert dry Sani-Sponge (kit part# 00132068). Next, insert Sani-Sponge soaked in Nu-Calgon IMS-II sanitizer solution. Push both Sani-Sponges down ice transport tube with supplied pusher tube (Fig. 9).
10. Remove and discard 16" (407mm) pusher tube (Fig. 10).
Fig. 9
1
Fig. 10
16"
(407mm)
2
3
10
11. Reconnect coupling. Press power switch ON. Ice pushes Sani-Sponges through tube (Fig. 11).
12. Place a sanitary (2 gallon or larger) container in bin or dispenser to collect Sani-Sponges and ice for 10 minutes. Collect 5.5 lbs of ice from unit. Discard ice and Sani-Sponges (Fig. 12).
Fig. 11
Fig. 12
11
Service
Icemaker operation (all models)
Follett’s icemaker consists of five distinct functional systems covered in detail as follows:
• Water system
• Electrical control system
• Mechanical assembly
• Refrigeration system
• Bin full
The Horizon icemaker overview
The Follett Horizon icemaker uses a horizontal, cylindrical evaporator to freeze water on its inner surface. The refrigeration cycle is continuous; there is no batch cycle. The evaporator is flooded with water and the level is controlled by sensors in a reservoir. A rotating auger (20 RPM) continuously scrapes ice from the inner wall of the evaporator. The auger moves harvested ice through the evaporator into an ice extrusion canal. The ice is forced through a restrictive nozzle that squeezes out the water and creates the Chewblet. The continuous extrusion process pushes the Chewblets through a transport tube into a dispenser or bin.
A solid state PC board controls and monitors the functionality of the ice machine. In addition to sequencing electrical components, the board monitors various operational parameters. A full complement of indicator lights allows visual status of the machine's operation. Additionally, the PC board controls the self-flushing feature of the icemaker. The evaporator water is periodically drained and replenished to remove minerals and sediment.
A unique “bin full” detection system is incorporated in the Horizon icemaker. A sensor located at the ice discharge port of the machine detects the position of the transport tube. When the bin fills up with ice, the transport tube moves out of the normal running position, and the sensor turns the ice maker off. A domed housing at the end of the transport tube contains the ice extrusion loads during shut down.
Harvest system diagram
ice transport tube
water inlet
compression nozzle
auger
12