Follett HCD710AHT, HCD710AHS, HCC1410WHT Installation Manual

Horizon Elite™ Ice Machine Installation Instructions
for Harmony
(See model number congurator on page 2 for details.)
Order parts online www.follettice.com
Horizon top-mount ice machines
t most countertop dispensers manufactured by
Top-mount Applications
Cornelius • Lancer • SerVend
self-contained
self-contained
801 Church Lane • Easton, PA 18040, USA Toll free (877) 612-5086 • +1 (610) 252-7301 www.follettice.com
01113323R02
Chewblet® Ice Machine Model Number Configurations
HC 1810D SVA
ConfigurationApplication
S RIDE™
(RIDE remote ice delivery equipment)
T Top-mount
MC Maestro™
Chewblet (425 Series)
HC Horizon
Chewblet (710, 1010, 1410, 1810, 2110 Series)
HM Horizon
Micro Chewblet
C 208-230/60/1 (icemaking head)
®
Self-contained only.
D 115/60/1 (icemaking head)
Self-contained and remote. If remote unit, high side is 208-230/60/1.
E 230/50/1 (icemaking head)
Self-contained only.
F 115/60/1 (icemaking head)
Remote only. High side is 208-230/60/3.
425 up to
425 lbs (193 kg)
710 up to
675 lbs (306 kg)
1010 up to
1061 lbs (482 kg)
1410 up to
1466 lbs (665 kg)
1810 up to
1790 lbs (812 kg)
2110 up to
2039 lbs (925 kg)
CondenserSeriesVoltageIcemaker
A Air-cooled, self-contained W Water-cooled, self-contained R Air-cooled, remote condensing unit N Air-cooled, no condensing unit for
connection to parallel rack system
V Vision™ H Harmony™ B Ice storage bin J Drop-in M Ice Manager
diverter valve system
P Cornelius Profile
PR150
CAUTION!
• This appliance should be connected by a qualied person in accordance with applicable codes.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied persons in order to avoid a hazard.
• Connect to potable water supply only.
• This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children should be supervised to ensure that they do not play with the appliance.
• This appliance is intended to be used for household and similar applications such as staff kitchen areas in shops, offices and other working environments; farm houses and by clients in hotels, motels and other residential type environments; bed and breakfast type environments; catering and similar non-retail applications.
• WARNING! To avoid a hazard due to instability of the appliance, it must be xed in accordance with the instructions.
2
self-contained HARMONY • TOP-MOUNT
Read and complete the following 8 installation steps
Site preparationUnpack
21
Bin preparation
43
Ice transport tube
5 6
87
Louvered docking assembly
External connection
Front coverInternal connection
HARMONY • TOP-MOUNT self-contained
3
Carefully unpack and inspect the contents of your Follett ice machine.
Unpack
1
1. 1
Unpack ice machine
7/16"
DO NOT TILT ICE MACHINE TO ACCESS BOLTS!
7/16"
4
COMPRESSOR DAMAGE WILL RESULT
self-contained HARMONY • TOP-MOUNT
1" Stand pipe/Drain
3/4" MPT x 1" slip
3/4" barb x 3/4" FPT
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
Site preparation
Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2m) of ice machine in accordance with local and national codes. Outdoor installation is not recommended and will void warranty.
2
2.1
2.1
Installation site requirements
1/4" (6,4 mm)
H_C1010A/W
H_D710A
1' (0,3 m)
NEMA
6-15
NEMA
5-15
H_E1010A/W
requires 15A circuit,
H_E1410A/W
requires 20A circuit,
1.50 mm
4.00 mm
2
wire
2
wire
H_C1410A/W
NEMA
6-20
Electrical ➊
• H_C1010/1410(A/W)HT 208-230/60 • H_D710AHT 115/60
• H_E1010/1410(A/W)HT 230/50
(H_E1010A/W requires 15A dedicated circuit 1.50 mm2 wire, H_E1410A/W requires 20A dedicated circuit 4.00 mm2 wire) ‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply ➋ (3/8” push-in internal connection, 3/8” OD tubing required)
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Follett recommends the use of an in-line water ltration system (item# 00130286)
• This equipment is to be installed with adequate backow protection to comply with applicable federal, state, and local codes
Condenser water supply for water-cooled systems
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 to 90 F (7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
• Minimum 8” radius on silicone drain line. Drain line from the ice machine must have at least 1/4” per foot pitch (6,4mm/0,3m).
HARMONY • TOP-MOUNT self-contained
(3/4” Barb)
Requires dedicated 15A circuit.
(1/4” FPT inlet, 1/4” FPT outlet)
5
Dispenser preparation
Prepare the dispenser.
Note: The instructions below only apply to 22" & 30" wide dispensers.
44" wide dispenser instructions may be found with the top kit.
3
3.1
Top preparation – ALL
All models
• Remove protective tape from gaskets
3.2
Top preparation – ALL
• Apply gaskets ➊.
• Install coupling dispenser top and secure with locking nut
through bottom of
3.3
Top preparation – ALL
• Screw 4" (102mm) extension bottom of shuttle actuator
into
3.4
Top preparation – CORNELIUS
Cornelius models only
• Remove protective tape
• Apply gasket
6
self-contained HARMONY • TOP-MOUNT