Follett HCD1010NHT, HCF1010RHS, HCD1010NHS, HCF1410RHT, HCD1410RHT User Guide

...
HCD1010R/N, HCD1410R/N, HMD1010R/N, HMD1410R/N, HCF1010R/N, HCF1410R/N, HMF1010R/N, HMF1410R/N
Horizon Elite™ 1010/1410 Ice Machines
(Remote Condensing)
User Guide
Please visit www.follettice.com/technicaldocuments
for the Operation and Service manual for your unit.
Welcome to Follett
Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and outstanding after-the-sale support. To ensure that this equipment delivers that same degree of service, review this guide carefully before you begin your installation.
Should you need technical help, please call our Technical Service group at (877) 612-5086 or (610) 252-7301.
Please have your model number, serial number and complete and detailed explanation of the problem when contacting Technical Service.
Getting Started
After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. All freight is to be inspected upon delivery. If visible signs of damage exist, please refuse delivery or sign your delivery receipt "damaged." Follett Customer Service must be notied within 48 hours. Wherever possible, please include detailed photos of the damage with the original packaging so that we may start the freight claim process.
801 Church Lane • Easton, PA 18040, USA Toll free (877) 612-5086 • +1 (610) 252-7301
Horizon Elite 1010/1410 Ice Machines (Remote Condensing) 1
www.follettice.com
Installation and Service Videos:
www.follettice.com/servicevideolibrary
CAUTION
• Warranty does not cover exterior or outside installations.
• Moving parts. Do not operate with front cover removed.
• Hot parts. Do not operate with cover removed.
• To reduce risk of shock, disconnect power before servicing.
• Drain line must not be vented.
• Water supply must have particle ltration.
• Most ice machine cleaners contain citric or phosphoric acid, which can cause skin irritation. Read caution label on product and follow instructions carefully.
• Ice is slippery. Maintain counters and oors around dispenser in a clean and ice-free condition.
• Ice is food. Follow recommended cleaning instructions to maintain cleanliness of delivered ice.
Specications
Electrical
Separate circuit and equipment ground required.
Evaporator unit
Standard electrical: 115/60/1 Maximum fuse: 15A Amperage: 5A
Condensing unit
1010
Single-Phase
(Tecumseh)
Electrical 208-230 V,
60 Hz
Max Circuit
15A 15A 30A 25A 15A 20A HVACR breaker size
Min Circuit
10.7A 9.9A 19.3A 14.2A 15A 15A
Ampacity
1010
3-Phase
(Tecumseh)
208-230 V,
60 Hz
1410
Single-Phase
(Tecumseh)
208-230 V,
60 Hz
1410
3-Phase
(Tecumseh)
208-230 V,
60 Hz
1410
3-Phase
(Larkin
LZT015M6CFIM)
208-230 V,
60 Hz
LCH0015MCACZ)
Evaporator plumbing
§ 3/8" OD push-in water inlet (connection inside machine) - 3/8" OD tubing required.
§ Water shut-off recommended within 10 feet (3 m).
§ Follett recommends installation of Follett water lter system (part# 00130286) in ice machine inlet water line.
1410
3-Phase
(Larkin
208-230 V,
60 Hz
2 Horizon Elite 1010/1410 Ice Machines (Remote Condensing)
Flush drain plumbing
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
3/4" MPT x 1" slip
1" PVC Drain
2 ft. x 1" OD
silicone tubing
3/4" MPT x 1" slip
3/4" barb x 3/4" FPT
1'
1/4" per foot
(6,4 mm per 0,3 m)
§ 3/4" MPT ush drain connection at the rear of the machine.
§ Drain must slope 1/4" inch per foot (6 mm per 30.4 cm).
§ Drain line should not be shared with any other piece of equipment.
§ Drain line cannot be reduced to a size smaller than 1 inch.
§ Drain should be piped without a vent.
Chassis drain plumbing
§ Plug must be removed from John Guest tting.
§ Route 3/8" drain tubing through knockout in back of docking station and insert fully into John Guest tting connection at the rear of the machine chassis. Route other end of 3/8" drain tubing to drain.
§ Drain must slope 1/4" inch per foot (6 mm per 30.4 cm).
Horizon Elite 1010/1410 Ice Machines (Remote Condensing) 3
Ambient
Evaporator unit
Air temperature 100 F/38 C max. 50 F/10 C min.
Water temperature 90 F/32 C max. 45 F/7 C min.
Water pressure 70 psi max. (483 kPa) 10 psi min. (69 kPa)
Condenser unit
Air temperature 120 F/49 C max. –20F/–29C min.
Refrigeration
§ 3/8" liquid line
§ 5/8" suction line
Note: Rack system installations require a capacity of 10,000 BTU/hr for 1010 machines and 13,000 BTU/hr for
1410 machines at 0 F (–18 C) evaporator temperature. Evaporator pressure regulator (not supplied) is required.
Weight
Evaporator unit: 125 lbs (57 kg) Condensing unit:
Horizon Elite 1010 series Horizon Elite 1410 series
Approximate ship weight 260 lb (118 kg) 270 lb (122 kg) – single phase (Tecumseh)
230 lb (104 kg) – three phase (Larkin)
Approximate net weight 250 lb (114 kg) 260 lb (118 kg) – single phase (Tecumseh)
210 lb (95 kg) – three phase (Larkin)
Ice production
1010 ice machine capacity/24 hrs.
Ambient Air Temperature F/C
F 60 70 80 90 100
C 16 21 27 32 38
50 1051 978 906 834 763 lbs
10 477 444 411 379 346 kg
60 994 925 855 796 737 lbs
16 451 420 388 361 335 kg
70 937 871 805 758 7 11 lbs
21 425 395 365 344 323 kg
80 904 839 7 74 727 680 lbs
27 410 381 351 330 309 kg
90 872 807 74 3 696 648 lbs
Evap Potable Water Temperature F/C
32 396 366 337 316 294 kg
1410 ice machine capacity/24 hrs.
Ambient Air Temperature F/C
F 60 70 80 90 100
C 16 21 27 32 38
50 1474 1372 1269 1212 1154 lbs
10 669 623 576 550 524 kg
60 1385 1292 119 8 11 4 8 1097 lbs
16 628 586 544 521 498 kg
70 1296 1212 11 2 7 1083 1039 lbs
21 588 550 5 11 492 472 kg
80 1239 1155 1072 1030 988 lbs
27 562 524 487 468 449 kg
90 90 118 1 1099 1017 976 lbs
Evap Potable Water Temperature F/C
32 32 536 499 462 425 kg
4 Horizon Elite 1010/1410 Ice Machines (Remote Condensing)
Dimensions and clearances
§ Entire front of ice machine must be clear of obstructions/connections to allow removal.
§ 1" (26 mm) clearance above ice machine for service.
§ 1" (26 mm) minimum clearance on sides.
§ The intake and exhaust air grilles must provide at least 250 sq in (1615 sq cm) of open area.
§ Air-cooled ice machines – 18" (458 mm) minimum clearance between discharge and air intake-grilles.
1410 ONLY
1410 ONLY
NEMA 5-15 RIGHT ANGLE
A
C (1410 ONLY)
B
K
D (1410 ONLY)
A 21.26" (54.0 cm) B 21.11" (53.6 cm) C 23.77" (60.4 cm)
E
D 2.66" (6.8 cm) E 19.59" (49.8 cm)
F
F 16.00" (40.6 cm) G 2.73" (6.9 cm) H 2.28" (15.3 cm) I 6.04" (5.8 cm)
G
H
I
J
J 22.00" (55.9 cm) K 22.69" (57.6 cm)
Horizon Elite 1010/1410 Ice Machines (Remote Condensing) 5
Condensing unit
1010/1410 single phase (Tecumseh)
1010 three phase (Tecumseh)
D1
W1
H1
1410 three phase (Larkin)
D1
W1
H1
Horizon Elite 1010 series Horizon Elite 1410 series
W1 Width 36.25" (91.4 cm) – all models 36.25" (90.1 cm) – single phase (Tecumseh)
37.75" (95.9 cm) – three phase (Larkin)
D1 Depth 25.50" (64.8 cm) – all models 25.50" (64.8 cm) – single phase (Tecumseh)
28.25" (71.6 cm) – three phase (Larkin)
H1 Height 26.10" (66.3 cm) – all models 26.10" (66.3 cm) – single phase
19.75" (50.2 cm) – three phase (Larkin)
Electrical single phase – 208-230/60/1
three phase – 208-230/60/3
Operating power single phase – 2.4 kW
three phase – 2.2 kW
Minimum circuit ampacity single phase – 10.7 A
three phase – 9.9 A
Maximum overcurrent protection single phase – 15 A
three phase – 15 A
Outdoor condensing unit operating limits (air temperature)
min -20 F (-29 C) max 120 F (49 C)
single phase – 208-230/60/1 (Tecumseh) three phase – 208-230/60/3 (Larkin)
single phase – 4.2 kW (Tecumseh) three phase – 3.0 kW (Larkin)
single phase – 19.3 A (Tecumseh) three phase – 15 A (Larkin)
single phase – 30 A (Tecumseh) three phase – 15 A (Larkin)
min -20 F (-29 C)
max 120 F (49 C) Maximum refrigerant line run length 100' (30.5 m) 100' (30.5 m) Maximum line rise above evaporator 35' (10.7 m) 35' (10.7 m) Evaporator mounting above condenser 15' (4.6 m) 15' (4.6 m) Maximum refrigeration line drop without oil trap 15' (4.6 m) 15' (4.6 m) Refrigerant charge 12.5 lb required at installation 12.5 lb – single phase (Tecumseh)
10 lb – three phase (Larkin)
required at installation Approximate ship weight 260 lb (118 kg) 270 lb (122 kg) – single phase (Tecumseh)
230 lb (104 kg) – three phase (Larkin) Approximate net weight 250 lb (114 kg) 260 lb (118 kg) – single phase (Tecumseh)
210 lb (95 kg) – three phase (Larkin) NOTE:
1. The entire liquid line should be insulated separately from the suction line.
6 Horizon Elite 1010/1410 Ice Machines (Remote Condensing)
Loading...