(See model number congurator on page 2 for details.)
Order parts online
www.follettice.com
Horizon ice machines with RIDE technology
to t most countertop dispensers manufactured by
Cornelius • Lancer • SerVend
™
self-contained
801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com
01113224R02
Chewblet® Ice Machine Model Number Configurations
HC1810DSVA
ConfigurationApplication
S RIDE™
(RIDE remote
ice delivery
equipment)
T Top-mount
MC Maestro™
Chewblet
(425 Series)
HC Horizon
Chewblet
(710, 1010,
1410, 1810,
2110 Series)
HM Horizon
Micro Chewblet
C 208-230/60/1 (icemaking head)
®
Self-contained only.
D 115/60/1 (icemaking head)
Self-contained and remote. If remote
unit, high side is 208-230/60/1.
E 230/50/1 (icemaking head)
Self-contained only.
F 115/60/1 (icemaking head)
Remote only. High side is
208-230/60/3.
425 up to
425 lbs
(193 kg)
710 up to
675 lbs
(306 kg)
1010 up to
1061 lbs
(482 kg)
1410 up to
1466 lbs
(665 kg)
1810 up to
1790 lbs
(812 kg)
2110 up to
2039 lbs
(925 kg)
CondenserSeriesVoltageIcemaker
A Air-cooled, self-contained
W Water-cooled, self-contained
R Air-cooled, remote condensing unit
N Air-cooled, no condensing unit for
connection to parallel rack system
V Vision™
H Harmony™
B Ice storage bin
J Drop-in
M Ice Manager
diverter valve
system
P Cornelius Profile
PR150
CAUTION!
§ This appliance should be connected by a qualied person in accordance with applicable codes.
§ If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied
persons in order to avoid a hazard.
§ Connect to potable water supply only.
§ This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory,
or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards involved. Children should be
supervised to ensure that they do not play with the appliance.
§ This appliance is intended to be used for household and similar applications such as staff kitchen areas
in shops, offices and other working environments; farm houses and by clients in hotels, motels and other
residential type environments; bed and breakfast type environments; catering and similar non-retail
applications.
§ WARNING! To avoid a hazard due to instability of the appliance, it must be xed in accordance with the
instructions.
Site Preparation .............................................................................................................................................................. 5
Installation site requirements .....................................................................................................................................5
Dispenser Top Preparation ............................................................................................................................................ 6
Top preparation ..........................................................................................................................................................6
Mount Ice Machine .........................................................................................................................................................7
Ice machine in cabinet ...............................................................................................................................................7
Transport tube installation ....................................................................................................................................... 10
Air-cooled ice machines only ................................................................................................................................... 12
Water-cooled ice machines only .............................................................................................................................. 12
Ice transport tube .................................................................................................................................................... 13
Potable water lines ................................................................................................................................................... 13
Power cord ............................................................................................................................................................... 13
Power cord ............................................................................................................................................................... 13
Ice transport tube .................................................................................................................................................... 14
Potable Water Line ................................................................................................................................................... 15
Cooling lines and power ..........................................................................................................................................15
Power cord ............................................................................................................................................................... 15
Front Cover ................................................................................................................................................................... 17
Install cover - undercounter air-cooled application only .......................................................................................... 17
Install front cover .....................................................................................................................................................17
Dispenser diverter plate overview – CORNELIUS, ED, DF AND DB SERIES
(installation on next page) ....................................................................................................................................20
Dispenser diverter plate installation – CORNELIUS, ED, DF AND DB SERIES ....................................................21
RIDE model ice machine start up procedure ............................................................................................................22
Before turning on power ..........................................................................................................................................22
After turning on power .............................................................................................................................................22
Provide drainage, potable water supply and electrical power to within 6 feet (2 m) of ice
machine in accordance with local and national codes. Outdoor installation is not recommended
and will void warranty.
2.1 Installation site requirements
H_C1010
NEMA
➊
6-15
➋
➌
H_D710
NEMA
5-15
H_C1410
NEMA
6-20
➍
115 V ±5%, 208 V –5% to 230 V +5%
Electrical ➊
WARNING!
§ This appliance should be connected by a qualied person in accordance with applicable codes.
§ If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied
persons in order to avoid a hazard.
Minimum 8” radius on silicone drain line. The drain line from the ice machine must have at least 1/4 in. per foot
(6,4 mm/0,3 m) pitch
➌ (1/4" FPT inlet, 1/4" FPT outlet)
5
3. Dispenser Top Preparation
WARNING!
§ Prior to installing the louvered docking assembly, ensure that the drain tting is oriented (right or left) correctly
for your installation. An optional straight drain tting is also supplied. You may need to remove the back panel
of the docking assembly in order to re-orient or change the drain tting. Replace back panel prior to mounting
the docking assembly.
§ Docking station must be secured in accordance with these instructions to ensure ice machine stability.
§ Ventilation openings in the louvered docking station should be clear of obstruction. Failure to do so could
result in damage to equipment.
§ Plug must be accessible after nal installation.
3.1 Top preparation3.2 Install shuttle actuator
5"
(12,7 cm)
2.75 to 3" ∅
(7 to 7,6 cm)
➋
➊
§ Locate shuttle actuator hole 5" (127mm) from back
of dispenser top.
§ Cut a 2.75" to 3" (7 to 7,6 cm) diameter hole in
dispenser top for shuttle actuator.
§ Apply gaskets
§ Install shuttle actuator
and secure with locking nut ➌.
Ice machines can be installed undercounter/in-cabinet to ll bins or dispensers using RIDE technology. Care
must be taken to ensure proper cabinet venting to avoid recirculation of hot air. Improper venting can cause ice
machine outages.
DOCKING STATION: Horizon
(See detail drawing on page 9)
§ Position and screw louvered docking assembly to the bottom of counter inside of access panel/door 2" (51 mm)
from the front edge of the cross brace
§ The mounting surface for the louvered docking assembly must be solid.
Do not mount directly onto runners or channels.
§ There must be no lip or edge that would hinder the ice machine from sliding in or out of the louvered docking
station
➋
INTAKE AND EXHAUST GRILLE PLACEMENT: Air-cooled models only
(See detail drawing on page 9)
§ Position the intake grille cut out in the access panel/door Note: Ice machine must be aligned with cut out and inside of access panel to provide a tight seal and prevent
recirculation of hot exhaust air.
§ Left edge of cutout should be 2.25" (57 mm) from the left side of the ice machine
§ Bottom edge of cutout should be 2" (51 mm) from the bottom of the ice machine
§ Position supplied exhaust grille at least 18" (458mm) away from intake grille ➎.
Where possible, install exhaust grille to the rear or side of the base cabinet.
§ If not using supplied grille, air circulation requirements below must be met:
250 sq. in (1613 sq cm) intake air, 250 sq. in (1613 sq. cm) exhaust air