Page 1
Horizon™ Ice Machine Installation Instructions
to Ice Storage Bin Top-mount Applications
HCC/HMC/HCE/HME1000ABT, HCC/HMC/HCE/HME1400ABT,
HCC/HMC/HCE/HME1000WBT, HCC/HMC/HCE/HME1400WBT,
(See model number con gurator on page 2 for details.)
Order parts online
www.follettice.com
self-contained
a
i
n
a
v
l
y
s
n
en
P
O
n
N
o
t
T
s
R
E
a
L
A
E
P
G
N
I
S
E
S
A
H
P
Z
OZ
H
N
NO
O
L
I
A
G
I
I
AT
S
R
R
P
E
S
PO
E
R
D
G
E
O
R
T
C
S
A
C
T
E
T
CH
OL
O
V
N
I
PR
E
E
D
Y
AD
I
L
S
M
SA
L
U
A
E
W
H
L
M
O
T
E
R
L
E
D
H
F
O
T
S
M
R
N
O
S
S
E
PS
PR
M
U
L
M
A
R
O
D
C
A
O
L
TOR
L
C
O
L
U
L
M
FU
R
S
P
M
E
A
D
I
ANT
S
R
H
E
S
G
G
I
I
R
H
MP
F
A
E
E
R
R
U
S
S
E
R
P
Y
T
I
N
C
A
G
P
I
S
M
A
E
T
I
D
U
E
RC
I
Z
I
C
S
H
SE
U
NC
F
A
T
R
I
B
U
C
N.
I
R
I
M
C
H
C
N
A
BR
.
AX
M
208264
Stock Module Identification Plate
Module No.
Product
Service No.
801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com
00159905R07
Page 2
Chewblet® Ice Machine Model Number Configurations
HC 1400 CS V A
MC Maestro™
Chewblet
(400 Series)
HC Horizon
Chewblet
(1000, 1400,
1650 Series)
HM Horizon
Micro Chewblet
C 208-230/60/1 (icemaking head)
®
Self-contained only.
D 115/60/1 (icemaking head)
Self-contained and remote. If remote
unit, high side is 208-230/60/1.
E 230/50/1 (icemaking head)
Self-contained only.
F 115/60/1 (icemaking head)
Remote only. High side is
208-230/60/3.
400 up to
454 lbs
(206kg)
1000 up to
1036 lbs
(471kg)
1400 up to
1450 lbs
(658kg)
1650 up to
1580 lbs
(717kg)
Condenser Series Voltage Icemaker
A Air-cooled, self-contained
W Water-cooled, self-contained
R Air-cooled, remote condensing unit
N Air-cooled, no condensing unit for
connection to parallel rack system
V Vision™
H Harmony™
B Ice storage bin
J Drop-in
M Ice Manager
diverter valve
system
Configuration Application
S RIDE™
(RIDE remote
ice delivery
equipment)
T Top-mount
2
self-contained BIN • TOP-MOUNT
Page 3
Read and complete the following 8 installation steps
Site preparation Unpack
2 1
Bin preparation
4 3
Ice transport tube
5 6
8 7
Louvered docking assembly
External connection
Front cover Internal connection
BIN • TOP-MOUNT self-contained
3
Page 4
Carefully unpack and inspect the contents of your Follett ice machine.
Unpack
1
1. 1
Unpack ice machine
4
self-contained BIN • TOP-MOUNT
Page 5
Site preparation
Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2m) of ice
machine in accordance with local and national codes. Outdoor installation is
not recommended and will void warranty.
2
2.1
2.1
Installation site requirements
208264
Stock Module Identification Plate
Module No.
Product
Service No.
2
wire
2
wire
‡
‡
ia
n
sylva
n
n
e
NO
ston P
a
ART
E
P
INGLE
E
S
PHAS
Z
O
HZ
O
N
ION
T
AL
IG
TED
RI
S
E
P
ORA
EC
S
P
R
GE
OT
R
R
CO
TS
P
L
CHA
LLY
VO
N
I
E
DE
D
I
A
A
RMA
S
M
U
E
W S
E
O
TH
L
SOR TH
MODEL
N SF
S
AMPS
U
L
D
R
COMPRE
A
O
TOR
O
C
U
L
M
FULL L
R
S
P
SIDE
NT
AM
HIGH
S
IGERA
E
P
R
M
F
UR
A
RE
SS
PRE
ACITY
N
P
AM
T
I
E
ESIG
U
IZ
D
S
RC
I
C
SE
H
U
C
N
T F
I
A
U
R
C
R
N. B
I
CI
M
H
C
N
BRA
.
X
MA
H_E1000A/W
requires 15A circuit,
1.50 mm
H_E1400A/W
requires 20A circuit,
4.00 mm
NEMA
6-15
H_C1000A/W
NEMA
6-20
H_C1400A/W
1/4" (6,4mm)
Electrical
➊
1' (0,3m)
• H_C1000(A/W)BT 208-230/60/1-15 amps • H_C1400(A/W)BT 208-230/60/1-20 amps
• H_E1000(A/W)BT 230/50/1-15 amps‡ • H_E1400(A/W)BT 230/50/1-20 amps
(H_E1000A/W requires 15A circuit, 1.50 mm2 wire) (H_E1400A/W requires 20A circuit, 4.00 mm2 wire)
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply
➋
‡
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Follett recommends the use of an in-line water ltration system (#00130286)
Condenser water supply for water-cooled systems
➌
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 to 90 F (7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
➍
• The drain line from the ice machine must have at least 1/4” per foot pitch (6,4mm/0,3m)
BIN • TOP-MOUNT self-contained
5
Page 6
Prepare the bin.
Bin preparation
3
3.1
• Remove protective tape from gaskets
Bin top preparation
3.2
Bin top preparation
➋
➊
➊
• Apply gaskets
• Install shuttle actuator
dispenser top and secure with locking nut
➊
through
➋
➌
➌
6
self-contained BIN • TOP-MOUNT
Page 7
Louvered docking assembly
Install the louvered docking assembly.
WARNING
• Docking station must be secured in accordance with these instructions to ensure ice machine
stability.
• Ventilation openings in the louvered docking station should be clear of obstruction
4
4.1
• Mount louvered docking assembly
Louvered docking assembly
BIN • TOP-MOUNT self-contained
7
Page 8
Install the ice transport tube.
Ice transport tube
5
5.1
Ice transport tube installation
Hot Water
160 F (71 C)
• Install supplied ice transport tube insulation
• Heat end of transport tube in cup of 160 F (71 C) hot water to soften and spread with pliers
before making connection to ease assembly
• Connect ice transport tube to coupling on louvered docking station
• Connect ice transport tube to shuttle actuator
➌
➋
➊
8
self-contained BIN • TOP-MOUNT
Page 9
Connect utilities to louvered docking assembly.
External connections
6
6.1
Air-cooled ice machines only
➋
➊
• Remove access panel if necessary
• Install drain line
The rigid drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Install ice machine potable water
supply
• Replace access panel
➋
➊
.
6.2
Water-cooled ice machines only
➌
➋
➍
➊
• Remove access panel if necessary
• Install drain line
The rigid drain line from the ice machine
must have at least 1/4" per foot pitch.
• Connect cooling water supply
return
• Install ice machine potable water
supply
• Replace access panel
➌
➍
➊.
➋
and
BIN • TOP-MOUNT self-contained
9
Page 10
Connect louvered docking assembly to ice
machine.
CAUTION
• Plug must be accessible after nal installation.
• H_E1400A/W 230/50/1 requires a 20A circuit (4.00 mm2 wire)
Air-cooled ice machines – follow steps 7.1 through 7.4.
Internal connections
7
7. 1
Ice transport tube
➋
➊
• Slide ice machine into louvered docking
assembly
• Insert ice transport tube all the way into
coupling and tighten nut rmly
➊
➋
7. 2
Potable water line
➊
• Insert potable water line into valve
• Push drain line over hose barb on
back of evaporator mount
➋
➊
➋
➋
➊
7. 3
Power cord
➊
• Remove twist tie
• Carefully pass plug thru opening and plug
into wall outlet
10
self-contained BIN • TOP-MOUNT
7. 4
• Position plate into opening and secure
Power cord
with supplied screw
Page 11
Water-cooled ice machines – follow steps 7.5 through 7.10.
7. 5
• Install ice machine cooling water lines to
Cooling lines
Out
In
louvered docking assembly
7. 6
Ice transport tube
➋
➊
• Slide ice machine into louvered docking
assembly
• Insert ice transport tube into coupling and
tighten nut rmly
➊
➋
7. 7
Potable water and drain lines
➊
➋
➊
➋
• Insert potable water line into valve
• Push drain line over hose barb on back of
evaporator mount
➊
➋
Cooling lines and power
7. 8
A d justment will v o id w a rr ant y and ma y damage equipment.
Do not adjust.
A TTENTION INS T ALLER
V a l v e is pr eset at f a ct or y .
• Connect cooling water lines to ice
machine
• Water valve is set at the factory. DO NOT
remove seal or adjust water valve
➊
➋
BIN • TOP-MOUNT self-contained
11
Page 12
7. 9
Power cord
7. 1 0
Power cord
• Remove twist tie
• Carefully pass plug thru opening and plug
into wall outlet
• Position plate into opening and secure
with supplied screw
12
self-contained BIN • TOP-MOUNT
Page 13
Install front cover to ice machine.
Front cover
8
8.1
Water-cooled ice machines only
➋
➊
• Slide ice machine cover over machine
ensuring that tabs on back of cover
slip under louvers on back of louvered
docking assembly
• Insert and tighten two screws through
cover and into louvered docking assembly
➊
➋
NOTICE
Ice machine MUST be sanitized prior to operation!
Consult Operation and Service Manual provided with ice machine for sanitizing instructions.
BIN • TOP-MOUNT self-contained
13
Page 14
Long tube run recommendations
max. 2 ft (0,6m)
1/4" (6,4mm)
1' (0,3m)
• Pitch ice transport tube to allow melt water to drain towards ice machine
• Secure insulated ice transport tube at least every 2 ft (0,6m) to prevent dips or traps
➊
➋
14
self-contained BIN • TOP-MOUNT
Page 15
BIN • TOP-MOUNT self-contained
15
Page 16
801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com
00159905R07
3/13