Focusrite REDNET 3 User manual

User Guide
FA0771-02
www.focusrite.com

IMPORTANT SAFETY INSTRUCTIONS

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15. No naked flames, such as lighted candles, should be placed on the apparatus.
The appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
Do not use a damaged or frayed power cord.
If the mains plug supplying the apparatus incorporates a fuse then it should only be replaced with a fuse of identical or lower rupture value.
The apparatus shall be connected to a mains socket outlet with a protective earthing connection.
GB
Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/ apparatus combination to avoid injury from tip-over.
FIN
Laite on liitettävä suojamaadoituskoskettimilla va rustettuumpistorasiaan
NOR
Apparatet må tikoples jordet stikkontakt
SWE
Apparaten skall anslutas till jordat uttag
2
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (ser vicing) instructions
in the literature accompanying the appliance.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE AND OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHOULD NOT BE PLACED ON THIS APPARATUS.
ENVIRONMENTAL DECLARATION
Compliance Information Statement: Declaration of Compliance procedure
Product Identification: Focusrite RedNet Responsible party: American Music and Sound Address: 4325 Executive Drive Suite 300 Southaven MS 38672
Telephone: 800-431-2609
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For USA
To the User:
1. Do not modify this unit! This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not expressly approved by Focusrite may void your authority, granted by the FCC, to use this product.
2. Important: This product satisfies FCC regulations when high quality shielded cables are used to connect with other equipment. Failure to use high quality shielded cables or to follow the installation instructions within this manual may cause magnetic interference with appliances such as radios and televisions and void your FCC authorization to use this product in the USA.
3. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense
For Canada
To the User:
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
RoHS Notice
Focusrite Audio Engineering Limited has conformed where applicable, to the European Union’s Directive 2002/95/EC on Restrictions
of Hazardous Substances (RoHS) as well as the following sections of California law which refer to RoHS, namely sections 25214.10,
25214.10.2, and 58012, Health and Safety Code; Section 42475.2, Public Resources Code.
3
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS .............................................. 2
INTRODUCTION ................................................................5
About this User Guide .........................................................6
Box Contents ................................................................6
INSTALLATION GUIDE ........................................................... 7
Unit Connections and Features .................................................7
RedNet 3 - Front Panel ..........................................................7
RedNet 3 - Rear Panel...........................................................8
Physical Characteristics ......................................................10
Power Requirements.........................................................10
OTHER REDNET SYSTEM COMPONENTS ..........................................11
USING REDNET CONTROL.......................................................11
APPENDIX.................................................................... 12
Connector Pinouts...........................................................12
Performance Specifications ...................................................14
Focusrite RedNet Warranty and Service .........................................15
Registering Your Product .....................................................16
Customer Support and Unit Servicing ...........................................16
Troubleshooting ............................................................16
4

INTRODUCTION

Thank you for purchasing this Focusrite RedNet 3.
RedNet 3 is a multichannel, bidirectional digital audio interface for use with a RedNet digital audio networking system.
RedNet is a powerful, low latency, digital audio networking system designed specifically for music, recording studio and broadcast applications. It is based on Audinate’s Dante™, a well-established audio networking technology known for its extreme robustness. Dante - and the RedNet system ­is capable of transporting up to 512 channels of bidirectional audio (at 48 kHz sample rate) over a single Gigabit Ethernet link. The number of channels available in your DAW will depend on the host method being used.
RedNet 3 provides up to 64 channels of digital I/O (32 inputs, 32 outputs), in ADAT format. The ADAT connectivity consists of eight optical inputs and eight optical outputs. ADAT Inputs 1 to 4 and Outputs 1 to 4 can each carry 8 audio channels at 44.1 or 48 kHz. Outputs 5 to 8 duplicate the lower-numbered ports at these sample rates. At higher sample rates, Inputs 5 to 8 and Outputs 5 to 8 are used for the higher-numbered channels, and the per-port channel count is reduced from 8 to 4 (at 96 kHz) or to 2 (at 192 kHz).
The AES/EBU I/O makes Input and Output channels 1 to 8 available on a 25-pin Dsub connector, in addition to the ADAT format at the optical ports. Sample Rate Conversion (SRC) is available on the AES/EBU inputs; this may be selected from RedNet Control. (Note that the AES/EBU digital format encodes audio channels in pairs.) RedNet 3 is also provided with an S/PDIF input and an S/PDIF output; these carry Channels 1 and 2. Sample Rate Converters (SRCs) are fitted to the S/PDIF input. Word Clock Input and Word Clock Output connectors permit RedNet 3 to be either a master or slave to other digital audio devices outside the RedNet network.
The front panel has LEDs confirming the unit’s network status, sample rate and sync source, together with data activity for each group of eight digital inputs and outputs.
5
Loading...
+ 11 hidden pages