Fluke Ti27, Ti32 Data sheet

Fluke Industrial
Thermal Imagers
Models: Ti32, Ti29 and Ti27. Three models specifically
for industrial and electrical applications.
The P3 Series: Superior, not Superfluous. Fluke is how other tools are measured.
The greatest technological advancement in thermography may be how Fluke has made it so simple to capture images and analyze data right out of the box.
Superior image quality
Industry-leading thermal sensitivity and spatial resolution combined with a high definition display, creates the sharp­est images in the industry.
One-handed, easy-to-use interface
With just a push of your thumb, go from one-handed manual smart focus to adding picture-in-picture and even add voice comments.
Torture tested
Before a Fluke goes into your hands, we drop it from ours.
Ti27
•240x180IR
resolution
•43,200total IRpixels
Ti29
•280x210IR
resolution
•58,800total IRpixels
Ti32
•320x240IR
resolution
•76,800total IRpixels
Made in
the U.S.A.
of U.S. and
non U.S.
parts
Only Fluke thermal imagers are designed from the inside out to withstand a 6.5 ft drop.
Patented Fluke IR-Fusion
(Picture-in-picture and auto blending) Precision visible and IR image alignment allows Fluke to offer the only on-camera blended infrared and visible image to better diagnose issues.
Interchangeable lenses
Interchangeable wide-angle and IR-Fusion compatible telephoto lenses to cover any application.
Technical Data
®
Industrial
Mechanical, electromechanical and general building maintenance.
Process
Refractory insulation, tank and vessel levels, steam systems and traps, pipes and valves, etc.
Electrical
Unbalanced loads, overloaded systems, wiring mistakes or component failure, etc.
Fluke. Not just infrared, infrared you can use.
Patented Fluke IR-Fusion® Technology
More than picture in picture
Infrared images alone can be difficult to under­stand, which is why Fluke pioneered IR-Fusion, a revolutionary marriage of visible and infrared images never before seen in commercial or industrial thermal imagers. Automatically capturing a visible image with every infrared image allows to you always know exactly what you’re looking at.
®
Not all fusion is created equal
Don’t be fooled by imitators. No other manufacturer can boast on-camera blending. Compare the images. Only Fluke has mastered the ability to create the industry’s only transparent, perfectly blended and aligned visible and infrared images.
Fluke Competitor
Detailed specifications
Temperature
Ti32 Ti29 Ti27
Temperature measurement range (not calibrated below -10 °C)
Temperature measurement accuracy
-20 °C to +600 °C (-4 °F to +1112 °F)
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction Yes On-screen reflected background
temperature compensation
Yes
On-screen transmission correction Yes
Imaging performance
Image capture frequency 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation Detector type Focal Plane Array, uncooled
microbolometer, 320 x 240 pixels
Focal Plane Array, uncooled
microbolometer, 280 x 210 pixels
Focal Plane Array, uncooled
microbolometer, 240 x 180 pixels Thermal sensitivity (NETD) ≤ 0.045 °C at 30 °C target temp. (45 mK) ≤ 0.05 °C at 30 °C target temp (50 mK) Total pixels 76,800 58,800 43,200 Infrared spectral band 7.5 µm to 14 µm (long wave) Visual (visible light) camera Industrial performance 2.0 megapixel Minimum focus distance 45 cm (approx. 18 in) Standard infrared lens type Field of view 23 ° x 17 ° Spatial resolution (IFOV) 1.25 mRad 1.43 mRad 1.67 mRad Minimum focus distance 15 cm (approx. 6 in) Optional telephoto infrared lens type Field of view 11.5 ° x 8.7 ° Spatial resolution (IFOV) 0.63 mRad 0.72 mRad 0.84 mRad Minimum focus distance 45 cm (approx. 18 in) Optional wide-angle infrared lens type Field of view 46 ° x 34 ° Spatial resolution (IFOV) 2.50 mRad 2.86 mRad 3.34 mRad Minimum focus distance 7.5 cm (approx. 3 in) Focus mechanism Manual, one-handed Smart Focus capability
Image presentation
Palettes Standard Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted Ultra Contrast
Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra,
Grayscale Ultra, Grayscale Inverted Ultra Level and span Smooth auto-scaling and manual scaling of level and span Fast auto toggle between manual
and auto modes
Yes
Fast auto-rescale in manual mode Yes Minimum span (in manual mode) 2.5 °C (4.5 °F) Minimum span (in auto mode) 5 °C (9 °F)
IR-Fusion
Automatically aligned (parallax corrected) visual and IR blending
® information
Yes
Picture-In-Picture (PIP) Three levels of on-screen IR blending displayed in center of LCD Full screen infrared Three levels of on-screen IR blending displayed on LCD Color alarms (temperature alarms) High-temperature alarm (user-selectable) Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager
Image capture and data storage
® mode, emissivity, and reflected
Image capture, review, save mechanism
The Ti32, Ti29 and Ti27 allow users to adjust palette, blending, level, span, IR-Fusion
background temperature compensation, and transmission correction on a captured image before it is stored
One-handed image capture, review, and save capability
Storage medium SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with
60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via
included multi-format USB card reader
File formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp and .jpeg) files
Export file formats w/SmartView software
®
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Memory review Thumbnail view navigation and review selection
2 Fluke Corporation Ti32, Ti29 and Ti27 Industrial Thermal Imagers
General specifications
Operating temperature -10 °C to +50 °C (14 °F to 122 °F) Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries Relative humidity 10 % to 95 % non-condensing Display 9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover Controls and adjustments User selectable temperature scale (°C/°F)
Software SmartView Batteries Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level Battery life Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD) Battery charge time 2.5 hours to full charge AC battery charging Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included.
AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included. Power saving Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 Electromagnetic compatibility Meets all applicable requirements in EN61326-1:2006 C Tick IEC/EN 61326-1 US FCC CFR 47, Part 15 Class B Vibration 0.03 g2/Hz (3.8 grms), IEC 68-2-6 Shock 25 g, IEC 68-2-29 Drop 2 meter (6.5 feet) with standard lens Size (H x W x L) 27.7 cm x 12.2 cm x 17.0 cm (10.9 in x 4.8 in x 6.7 in) Weight (battery included) 1.05 kg (2.3 lb) Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions) Warranty Two-years (standard), extended warranties are available. Recommended calibration cycle Two-years (assumes normal operation and normal aging) Supported Languages Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish,
Language selection Time/Date set Emissivity selection Reflected background temperature compensation Transmission correction User selectable hot spot and cold spot, and center point on the image (other custom markers and shapes in SmartView High temperature alarm User selectable backlight: “Full Bright” or “Auto” Information display preference
Optional 12 V automotive charging adapter.
Swedish, Traditional Chinese, and Turkish
® full analysis and reporting software included
® software)
Ordering information
FLK-Ti32 9 Hz Industrial-Commercial Thermal Imager, 9 Hz FLK-Ti32 60 Hz Industrial-Commercial Thermal Imager, 60 Hz FLK-Ti29 9 Hz Industrial-Commercial Thermal Imager, 9 Hz FLK-Ti29 60 Hz Industrial-Commercial Thermal Imager, 60 Hz FLK-Ti27 9 Hz Industrial-Commercial Thermal Imager, 9 Hz FLK-Ti27 60 Hz Industrial-Commercial Thermal Imager, 60 Hz
Included
Thermal imager with standard infrared lens; ac power supply and battery pack charger (including mains adapters); two, rugged lithium ion smart battery packs; SD memory card; multi-format USB memory card reader for downloading images into your computer; SmartView® software with free software upgrades for life; rugged, hard carrying case; soft transport bag; adjustable hand strap; printed users manual; warranty registration card.
Optional accessories
FLK-LENS/TELE1 Telephoto Infrared Lens FLK-LENS/WIDE1 Wide-angle Infrared Lens TI-CAR-CHARGER Thermal Imager Vehicle Charger TI-VISOR Thermal Imager Visor BOOK-ITP Introduction to Thermography Principles Book TI-TRIPOD Tripod Mounting Base Accessory
3 Fluke Corporation Ti32, Ti29 and Ti27 Industrial Thermal Imagers
Fluke. Not just infrared. Infrared you can use.
Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2011 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 3/2011 4008148A D-EN-N
Modification of this document is not permitted without written permission from Fluke Corporation.