Fluke Ti25, Ti10, Ti9 Catalog Page

Fluke Ti25, Ti10, Ti9 Catalog Page

Fluke Ti25, Ti10 and

Ti9 Thermal Imagers

The ultimate tools for troubleshooting and maintenance

The perfect tools to add to your problem solving arsenal. Built for tough work environments, these high-performance, fully radiometric imagers are ideal for troubleshooting electrical installations, electro-mechanical equipment, process equipment, HVAC/R equipment and others.

Fluke Ti25 and Ti10 imagers come with enhanced problem detection and analysis capabilities with IR-Fusion® Technology. Simply scroll through the different viewing modes quickly to better identify trouble areas in Full IR thermal, picture-in-picture, or automatic blend visual and thermal images. Fluke Ti9 imagers can be upgraded to a full Ti10 with IR-Fusion at a later time.

Optimized for field use in harsh work environments.

Engineered and tested to withstand a 2 m (6.5 ft) drop—When was the last time you dropped a tool?

Withstands dust and water—tested to an IP54 rating.

Delivers the clear, crisp images needed to find problems fast.

Identify even small temperature differences that could indicate problems with excellent thermal sensitivity (NETD).

Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.

No need to carry pen and paper—record findings by speaking into the camera. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference (Ti25 only).

Everything needed to get started is included.

Adjustable hand strap for left-or right-handed use.

Manufactured in the U.S.A.

Technical Data

IR-Fusion® Technology

See things both ways—infrared and visual (visible light) images fused together communicating critical information faster and easier—traditional infrared images are no longer enough.

Fluke led the way in the development and use of IR-Fusion and the industry followed. Both visible and infrared images allow you to communicate exactly where potential savings can be gained. IR-Fusion is standard on Fluke Ti25 and Ti10 models.

Detailed specifications

 

 

Ti25

 

Ti10

 

Ti9

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature measurement range

-20 °C to +350 °C (-4 °F to + 662 °F)

 

-20 °C to +250 °C (-4 °F to + 482 °F)

 

(not calibrated below -10 °C)

 

 

 

 

 

 

 

 

 

 

 

 

 

Accuracy

± 2 °C or 2 % (whichever is greater)

 

± 5 °C or 5 % (whichever is greater)

 

 

 

 

 

 

 

On-screen emissivity correction

Yes

 

 

 

 

 

 

 

 

 

 

Imaging performance

 

 

 

 

 

 

 

 

 

 

 

 

Field of view

23° x 17°

 

 

 

 

 

 

Spatial resolution (IFOV)

2.5 mRad

 

 

 

 

 

 

 

 

Minimum focus distance

Thermal lens: 15 cm (6 in)

 

 

Thermal lens only:

 

 

Visible (visual) light lens: 46 cm (18 in)

 

15 cm (6 in)

 

 

 

 

 

 

Focus

Manual, one-handed focus

 

 

 

 

 

 

Image frequency

9 Hz refresh rate

 

 

 

 

 

Detector type

160 X 120 focal plane array, uncooled microbolometer

 

 

 

 

 

Infrared lens type

20 mm F = 0.8 lens

 

 

 

 

 

 

Thermal sensitivity (NETD)

0.1 °C at 30 °C (100 mK)

 

0.2 °C at 30 °C (200 mK)

 

 

 

 

 

 

Infrared spectral band

7.5 μm to 14 μm

 

 

 

 

 

 

Visual camera

640 x 480 resolution

 

 

 

 

 

 

 

 

 

Image presentation

 

 

 

 

 

 

 

 

 

 

 

 

 

Palettes

Ironbow, blue-red, high contrast,

 

Ironbow, blue-red, high contrast, grey

 

 

amber, hot metal, grey

 

 

 

 

 

 

 

 

 

 

 

 

Level and span

Smooth auto-scaling and manual scaling of level and span

 

 

 

 

 

Minimum span (in manual mode)

2.5 °C (4.5 °F)

 

5 °C (9 °F)

 

 

 

 

 

 

Minimum span (in auto mode)

5 °C (9 °F)

 

10 °C (18 °F)

 

 

 

 

 

 

 

IR-Fusion® information

Full infrared with MAX, MID, or MIN

 

Full infrared or

 

No IR-Fusion. Full

 

 

automatic blending; and picture-in-picture

 

picture-in-picture

 

Infrared only. Ti9

 

 

with MAX, MID, or MIN automatic blending

 

 

 

models are upgrad-

 

 

(Visual and IR blending)

 

 

 

able to a full Ti10 for

 

 

 

 

 

 

an additional fee.*

 

 

 

 

 

 

 

 

Picture-In-Picture (PIP)

Three levels of on-screen IR blending

 

100 % IR displayed

 

 

 

 

 

in center

 

 

 

displayed in center 320 x 240 pixels

 

 

 

 

 

320 x 240 pixels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full screen (PIP off)

Three levels of on-screen IR blending

 

100 % IR displayed in center

 

 

displayed in center 640 x 480 LCD

 

640 x 480 LCD

 

 

 

 

 

 

 

 

Voice annotation

 

 

 

 

 

 

 

 

 

 

 

 

 

Voice annotation

60 seconds maximum recording time per image

 

 

 

 

 

 

 

 

 

 

Image and data storage

 

 

 

 

 

 

 

 

 

 

 

Storage medium

SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked

 

 

visual images each with 60 seconds voice annotations or 3000 basic (.bmp) IR images)

 

 

 

 

 

File formats

Non-radiometric (.bmp) or fully-radiometric (.is2).

 

 

 

No analysis software required for .bmp files.

 

 

 

 

 

 

 

 

 

Export file formats

JPEG, BMP, GIF, PNG, TIFF

 

 

w/SmartView® software

 

 

 

 

 

 

 

*Contact your Fluke sales representative for more information about upgrade options.

2 Fluke Corporation

Ti25, Ti10 and Ti9 Thermal Imagers

Loading...