The ultimate tools for
troubleshooting and
maintenance
The perfect tools to add to your problem solving
arsenal. Built for tough work environments, these
high-performance, fully radiometric imagers are
ideal for troubleshooting electrical installations,
electro-mechanical equipment, process equipment,
HVAC/R equipment and others.
Fluke Ti25 and Ti10 imagers come with enhanced
•
problem detection and analysis capabilities with
IR-Fusion® Technology. Simply scroll through the
different viewing modes quickly to better identify
trouble areas in Full IR thermal, picture-in-picture,
or automatic blend visual and thermal images.
Fluke Ti9 imagers can be upgraded to a full Ti10
with IR-Fusion at a later time.
Technical Data
Optimized for field use in harsh work environments.
•
Engineered and tested to withstand a 2 m (6.5 ft)
•
drop—When was the last time you dropped a tool?
Withstands dust and water—tested to an IP54 rating.
•
Delivers the clear, crisp images needed to find
•
problems fast.
Identify even small temperature differences that could
•
indicate problems with excellent thermal sensitivity
(NETD).
Intuitive, three-button menu is easy to use—simply
•
navigate with the push of a thumb.
No need to carry pen and paper—record findings by
•
speaking into the camera. Voice annotations can be
recorded with every image you take. Voice
comments are saved along with individual images
for future reference (Ti25 only).
Everything needed to get started is included.
•
Adjustable hand strap for left-or right-handed use.
•
Manufactured in the U.S.A.
•
IR-Fusion® Technology
See things both ways—infrared and visual (visible light)
images fused together communicating critical information
faster and easier—traditional infrared images are no
longer enough.
Fluke led the way in the development and use of
IR-Fusion and the industry followed. Both visible and
infrared images allow you to communicate exactly
where potential savings can be gained. IR-Fusion is
standard on Fluke Ti25 and Ti10 models.
Page 2
Detailed specifications
Ti25Ti10Ti9
Temperature
Temperature measurement range
(not calibrated below -10 °C)
Accuracy± 2 °C or 2 % (whichever is greater)± 5 °C or 5 % (whichever is greater)
On-screen emissivity correctionYes—
Imaging performance
Field of view23° x 17°
Spatial resolution (IFOV)2.5 mRad
Minimum focus distanceThermal lens: 15 cm (6 in)
FocusManual, one-handed focus
Image frequency9 Hz refresh rate
Detector type160 X 120 focal plane array, uncooled microbolometer
Infrared lens type20 mm F = 0.8 lens
Thermal sensitivity (NETD)≤ 0.1 °C at 30 °C (100 mK)≤ 0.2 °C at 30 °C (200 mK)
Infrared spectral band7.5 μm to 14 μm
Visual camera640 x 480 resolution
Image presentation
PalettesIronbow, blue-red, high contrast,
Level and spanSmooth auto-scaling and manual scaling of level and span
Minimum span (in manual mode)2.5 °C (4.5 °F)5 °C (9 °F)
Minimum span (in auto mode)5 °C (9 °F)10 °C (18 °F)
®
IR-Fusion
informationFull infrared with MAX, MID, or MIN
Picture-In-Picture (PIP)
Full screen (PIP off)Three levels of on-screen IR blending
Voice annotation
Voice annotation60 seconds maximum recording time per image—
Image and data storage
Storage mediumSD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked
File formatsNon-radiometric (.bmp) or fully-radiometric (.is2).
Export file formats
®
w/SmartView
software
-20 °C to +350 °C (-4 °F to + 662 °F)-20 °C to +250 °C (-4 °F to + 482 °F)
Thermal lens only:
Visible (visual) light lens: 46 cm (18 in)
amber, hot metal, grey
automatic blending; and picture-in-picture
with MAX, MID, or MIN automatic blending
(Visual and IR blending)
Ironbow, blue-red, high contrast, grey
Full infrared or
picture-in-picture
15 cm (6 in)
No IR-Fusion. Full
Infrared only. Ti9
models are upgrad-
able to a full Ti10 for
an additional fee.*
Three levels of on-screen IR blending
displayed in center 320 x 240 pixels
100 % IR displayed
in center
320 x 240 pixels
100 % IR displayed in center
displayed in center 640 x 480 LCD
640 x 480 LCD
visual images each with 60 seconds voice annotations or 3000 basic (.bmp) IR images)
No analysis software required for .bmp files.
JPEG, BMP, GIF, PNG, TIFF
—
*Contact your Fluke sales representative for more information about upgrade options.
2 Fluke Corporation Ti25, Ti10 and Ti9 Thermal Imagers
Page 3
General specifications
Temperature Operating: -10 °C to 50 °C (14 °F to 122 °F)
Storage: -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity10 % to 90 % non-condensing
Display9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with
backlight (selectable bright or auto)
Controls and adjustmentsUser selectable temperature scale (°C/°F)
Language selection
Time/Date set
Emissivity selection and Reflected Background Temperature Compensation (Ti25 only)
User selectable Hot Spot and Cold Spot on the image (Ti25 only)
Ti25 allows user to adjust palette, alpha blend, level, span, PIP, and emissivity on a captured
image before it is stored.
Battery life: Three to four hours continuous use (assumes 50 % brightness of LCD)
Battery charge time using ac adapter/charger and dc car charger: Two hours for full charge
AC operation/chargingAC adapter/charger (110 Vac to 220 Vac, 50 Hz to 60 Hz). Charges battery while
imager is operating. Universal ac mains adapters included.
Power savingSleep mode activated after 5 minutes of inactivity, automatic power off after 20 minutes of inactivity
Thermal imaging camera w/20 mm lens, ac power
supply/battery charger (including mains adapters), SD memory card, SD card reader
(USB) for downloading images into your computer, SmartView
software upgrades for life, rugged hard, carrying case, soft transport bag, hand strap,
users manual, warranty registration card, interactive training DVD.
Optional accessories
FLK-TI-CHARGER Thermal Imager Car Charger
FLK-Ti-VISOR Thermal Imager Visor
3 Fluke Corporation Ti25, Ti10 and Ti9 Thermal Imagers
®
software with free
Fluke. Not just infrared.
Infrared you can use.
™
Loading...