Fluke Test Tools Catalog

Page 1
Test Tools Catalog
2012 2013
Digital Multimeters
Clamp Meters
Electrical Testers
Insulation Testers
Earth Ground Testers
Portable Appliance Testers
Digital Thermometers
Thermal Imagers
Distance Meters
Indoor Air Quality Tools
®
ScopeMeter
Test Tools
Power Quality Tools
Field Calibrators
Vibration Tester
Radiation Tester
EX Test Tools
Accessories
Page 2
Contents
riešenia na presné meranie
http://www.elso.sk
Fluke web and electronic newsletter .................................................... 1
New from Fluke........................................................................................2-3
Fluke Combo Kits ..................................................................................... 4-5
Application/background articles ......................................................6
Fluke After Sales Service .................................................................. 7
Fluke where safety is built in .......................................................... 8-9
Fluke web/campaign ......................................................................... 10
Digital Multimeters ............................................................................ 11
DMM Selection Guide ....................................................................... 12
280 Series Digital Multimeters .......................................................13
233 Remote Display Multimeter ...................................................... 14
80 Series V Digital Multimeters ....................................................... 15
170 Series Digital Multimeters ........................................................16
110 Series II Digital Multimeters .....................................................17
27 II / 28 II Rugged Industrial Multimeters .................................... 18
77 IV Digital Multimeter ...................................................................19
88V Automotive Meter ......................................................................20
8845A/8846A 6.5 Digit Precision Multimeters ...............................21
8808A 5.5 Digit Multimeter .............................................................. 22
Clamp Meters and Electrical Testers ................................................23
Clamp Meter selection guide ........................................................... 24
381/365 Clamp Meters ...................................................................... 25
370 Series Clamp Meters .................................................................. 26
320 Series / 902 Clamp Meters ......................................................... 27
353/355 AC/DC Clamp Meters .......................................................... 28
360 Current Leakage Clamp Meter .................................................29
T100 Series Voltage/Continuity Testers .......................................... 30
T5/T5-H5-1AC Kit Electrical Testers ................................................ 31
2AC/1AC-II/LVD1/LVD2 Voltage Detectors ...................................... 32
9040/9062 Phase Rotation Indicators .............................................. 33
2042 Cable Locator ............................................................................ 34
Insulation Testers/Earth Ground Testers ......................................... 35
Insulation Tester Selection Guide ................................................... 36
1577/1587 Insulation Multimeters .................................................. 37
1503/1507 Insulation Testers ........................................................... 38
1555/1550C Insulation Resistance Testers .................................... 39
1620 Series Earth Ground Testers ...................................................40
1621 Earth Ground Tester .................................................................41
1630 Ground Loop Tester ..................................................................42
Installation Testers/Portable Appliance Testers ..............................43
1650 Series Multifunction Installation Testers.............................. 44-45
6000 Series Portable Appliance Testers .......................................... 46-47
1650/6000 Series Accessories ...........................................................48
Laser Distance Meters ....................................................................... 73
421D/416D/411D Laser Distance Meters ........................................74
Indoor Air Quality Tools ....................................................................75
975 Air Meter ......................................................................................76
922 Airflow Meter .............................................................................. 77
971 Temperature Humidity Meter ................................................... 78
983 Particle Counter .......................................................................... 79
ScopeMeter
ScopeMeter 190 Series II ..................................................................81-83
ScopeMeter 120 Series .....................................................................84
ScopeMeter 225C/S and general specifications ............................85
ScopeMeter Accessories ................................................................... 86
Power Quality Tools ........................................................................... 87
Power Quality Selection Guide ........................................................88
345 Power Quality Clamp Meter ...................................................... 89
43B Single-phase Power Quality Analyzer ..................................... 90
1710 Single-Phase Voltage Quality Recorder .................................91
430 II Series Three-phase Power Quality Analyzers ..................... 92-93
1735 Power Logger ............................................................................. 94
1740 Series Power Quality Loggers..................................................95
1750 Power Recorder ......................................................................... 96
1760 Power Quality Recorder ...........................................................97
Power Quality Current Clamp Accessories ....................................98
Norma 4000/5000 Series ................................................................... 99-100
Field Calibrators .................................................................................101
Field Calibrator Selection Guide ...................................................... 102
750 Series Documenting Process Calibrators ................................ 103
726/725/725Ex Multifunction Process Calibrators ........................104
724 Temperature Calibrator ............................................................. 105
712/714 Temperature Calibrators .................................................... 106
914X/418X Drywells/IR Calibrators ................................................. 107
717/718/718Ex/719 Pressure Calibrators ......................................... 108
705/707/707Ex/715 Loop Calibrators ............................................... 109
771/772/773 mA Clamp Meters ........................................................ 110
787/789 ProcessMeters......................................................................111
Field Calibrator Accessories ............................................................. 112
Vibration Tester ..................................................................................113
810 Vibration Tester .......................................................................... 114
Radation Meter ................................................................................... 115
481 Radation Meter ........................................................................... 116
®
Test Tools ...................................................................... 80
Digital Thermometers ....................................................................... 49
Infrared Thermometer Selection Guide .........................................50
570 Series Precision Infrared Thermometers ................................51
60 Series Infrared Thermometers ...................................................52
566/568 Multipurpose Thermometers ............................................ 53
561 Multipurpose Thermometer ..................................................... 54
50 Series II Thermometers ............................................................... 55
1523/1524 Reference Thermometers .............................................. 56
1551A/1552A Ex “Stik” Thermometers ........................................... 57
Thermal Imagers ...............................................................................58
Ti Series Thermal Imagers ...............................................................59
Ti32/Ti29/Ti27 Industrial Thermal Imagers ................................... 60-61
TiR32/TiR29/TiR27 Industrial Thermal Imagers
for Building Diagnostics ................................................................... 62-63
Ti125/Ti110/Ti100 Industrial / Commercial Thermal Imagers .... 64-65
TiR125/TiR110/Ti100 Building Diagnostic Thermal Imagers ....... 66-67
Ti9/Ti10/Ti25 Thermal Imagers ....................................................... 68-69
TiS/TiR/TiRx/TiR1 Thermal for Building Inspection ..................... 70-71
Hawk IR CRange IRWindows ........................................................... 72
ATEX Certified Test Tools ..................................................................117
A brief look at ATEX ..........................................................................118
Fluke intrinsically safe tools ............................................................ 119
General Accessories ........................................................................... 120
Electronic Test Leads, Probes & Clips ............................................. 121
Industrial Test Leads, Probes & Clips .............................................. 122-123-124
Automotive Accessories ...................................................................125
Current Clamps ................................................................................. 126-127
Temperature Accessories .................................................................128-129
Cases and Holsters ............................................................................ 130-131
Software and Other Accessories ..................................................... 132
Other Accessories .............................................................................. 133
Fuse and Warranty Information...................................................... 134
Fluke. Keeping your world up and running
Page 3
Electronic Newsletter
riešenia na presné meranie
http://www.elso.sk
Fluke web
Complete information
The most complete and in-depth resource for information on Fluke’s products and services including:
• Product information
• Solution Centers
• Interactive selection guides
• Virtual product demonstrations
• Extended specications
• Application notes
• Product manuals
• Service information
• Promotions
• Prices
• Where to buy
• Distributor and sales ofce locations
Find information fast
To quickly nd more information on Fluke products, use the “Search by model” box in the top left corner of our web pages. All you have to do is type in the model number.
Fluke Web and
UK: www.fluke.sk IE: www.fluke.sk Worldwide: www.fluke.sk
Fluke web sites are available in all countries around the world and in 18 different languages.
Electronic Newsletter
E-Test-it! is Fluke’s regular news publication for professional test tool users. It is electronically available 6 times per year. You will be the first to hear about:
• New Fluke products
• The latest actions and promotions from Fluke
• How to get more out of Fluke tools
• How to use Fluke tools better in your application
• Exclusive offers, promotions and discounts on Fluke Merchandizing
• Exclusive offers on Fluke ex-demo equipment
E-Test-it! is free of charge. If at any point in time you do not want to receive E-Test-it! anymore, you can unsubscribe with a simple mouse click. E-Test-it! is small in size (on average about 12 KB) and does not ll up your mailbox or take long to download.
Try it now and sign-up for your FREE e-Test-it! subscription. Go to the Fluke web site and fill in the on-line subscription form.
1
Page 4
New from Fluke
riešenia na presné meranie
http://www.elso.sk
Fluke 190 Series II Scopemeter
For the rst time, plant maintenance engineers and technicians can take a high-performance four-channel scope into the harsh world of industrial electronics.
See page 81-83.
Fluke TiS Thermal Imaging Scanner
Fluke proudly introduces an entry level thermal imager for quick, easy, and
accurate problem identication and troubleshooting designed specically for
Fluke 1654B Multifunction Installation Tester
The new 1654B Installation Tester builds upon the rugged reputation of the earlier 1650 Series, only it’s re-designed to meet your need for more productive test tools.
See page 44 and 45.
the building inspection professional.
See page 70 and 71.
Fluke 365 Detachable Jaw True-rms AC/DC Clamp Meter
The Fluke 365 is a new, innovative Fluke clamp meter, offering a thin,
small jaw design that makes it easy to get around tightly packed wires.
See page 25.
Fluke 750 series Documenting Process Calibrators
Fluke 750 series process calibrators can help you get the job done faster. It does so many different tasks, so quickly and so well, it’s the only process calibrator you need to carry.
See page 103.
Fluke 370 series Clamp Meters
With this new family of clamp meters, Fluke provides a range of state of-the-art
capabilities to meet users’ most demanding requirements for exibility, safety and
performance.
See page 26.
Fluke 381 Remote Display True-rms AC/DC ClampMeter with iFlex
The new Fluke 381 does everything you would expect from a clamp meter, and then lets you remove the display for even more exibility.
See page 25.
2
Page 5
New from Fluke
riešenia na presné meranie
http://www.elso.sk
Fluke Ti27/Ti29 Thermal Imagers
Designed for industrial and commercial environments, the Fluke P3 series of thermal imagers deliver superior image quality, versatility, and affordability without compromise.
See page 60-63.
Ti125/Ti110/Ti100/TiR125/TiR110 Thermal Imagers
Fluke proudly introduces ve new thermal imagers specically designed to help you do
more in less time, while being at home in the harshest of environments. A project that might normally take an hour can now be done in minutes. Our newest imagers are the
lightest, most rugged, easiest-to-use professional imagers you can buy.
See page 64-67.
Fluke 430 Series II Three-Phase Power Quality and Energy Analyzers
The new Fluke 434, 435 and 437 Series II models help locate, predict, prevent, and troubleshoot power quality problems in three-phase and single-phase power distribution systems.
See page 92-93.
1551A Ex and 1552A Ex “Stik” Thermometer
Accurate and repeatable to ± 0.05 °C over its full range, the 1551A/1552A “Stik”
Thermometer is the new “gold standard” of industrial temperature calibration.
See page 57.
Fluke 1555/1550C Insulation Resistance Testers
The new 1555 and redesigned Fluke 1550C insulation resistance testers offer digital insulation testing up to 10kV, making them ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables.
See page 39.
TL175 Twistguard™ Test Leads
The new Fluke TL175 TwistGuard™ Test Leads are the innovative test leads with adjustable
length test tips for use in different measurement environments.
See page 124.
3
Page 6
Fluke Combo Kits
riešenia na presné meranie
http://www.elso.sk
Buy a Combo Kit and save
Fluke 117/322 Kit Electrician’s Combo Kit
• Fluke 117 True RMS Multimeter
• Fluke 322 Clamp Meter
• Silicon test lead set
• TPAK Magnetic Hanger
• C115 Deluxe carrying case with shoulder strap
Fluke 179/MAG2 Kit Industrial Combo Kit
• Fluke 179 True RMS Multimeter
• TL224 SureGrip™ Silicone Test Lead Set
• AC220 SureGrip™ Alligator Clip Set
• TP74 lantern tip test probe set
• TPAK Magnetic Hanger
• 80BK-A Integrated DMM Temperature Probe
• C35 Soft Meter Case
• + Maglite ashlight
Fluke 179/TPAK 179/ToolPak Combo Kit
• Fluke 179 True RMS Multimeter
• TPAK ToolPak Meter Hanging Kit
Fluke 179/61 Kit Multimeter and Infrared Thermometer Combo Kit
• Fluke 179 True RMS Multimeter
• Fluke 61 Infrared Thermometer
• C550 Hard Meter and Accessory Case
Fluke 179/EDA2 Kit Electronics Combo Kit
• Fluke 179 True RMS Multimeter
• TL224 SureGrip™ Silicone Test Lead Set
• TL910 Electronic Test Probe Set
• AC280 SureGrip™ Hook Clip Set
• TPAK Magnetic Hanger
• 80BK-A Integrated DMM Temperature Probe
• C35 Soft Meter Case
Fluke 87V/E2 Industrial Electrician Combo Kit
• Fluke 87V True RMS Multimeter
• TL224 SureGrip™ Silicone Test Lead Set
• TP38 Slim Reach Test Probe Set (insulated)
• AC220 SureGrip™ Alligator Clip Set
• TPAK Magnetic Hanger
• 80BK-A Integrated DMM Temperature Probe
• C35 Soft Meter Case
Ordering Information
Fluke 117/322 Kit Fluke 179/TPAK Fluke 179/61 Kit Fluke 179/MAG2 Kit Fluke 179/EDA2 Kit Fluke 87V/E2 Fluke 87V/i410
4
Fluke 87V/i410 Combo Kit for Industrial Applications
• 87V Industrial Multimeter
• TL75 Test Leads
• AC172 Alligator Clips
• i410 400A AC/DC Current Clamp
• 80BK-A Temperature Probe
• C115 Soft Carrying Case
(Not available in all countries)
Page 7
Fluke Combo Kits
riešenia na presné meranie
http://www.elso.sk
Buy a Combo Kit and save
Fluke 287/FVF FlukeView Forms Combo Kit
• Fluke 287 True RMS Electronic Logging Multimeter with TrendCapture
• FVF-SC2 FlukeView Forms Software and cable
• 80BK-A Thermocouple Probe
• CAT III 1000 V 10 A Modular Test Leads (red, black)
• CAT II 300 V 5 A Alligator Clips (red, black)
• C280 Soft Case for meter protection and accessory storage
Fluke 289/FVF Industrial Logging Multimeter and Software Combo Kit
• Fluke 289 True-RMS Multimeter
• FVF-SC2 FlukeView Forms Software and cable
• Silicon Test Lead Set
• AC172 Alligator Clips
• 80BK-A Integrated DMM Temperature Probe
• TPAK Magnetic Meter Hanger for hands-free operation
• C280 Soft Case for meter protection and accessory storage
Fluke 1587/MDT Advanced Motor & Drive Troubleshooting Kit
• Fluke 1587 Insulation Multimeter
• Fluke 9040 Phase Rotation Indicator
• I400 Current Clamp
Fluke 1587/MDT
Fluke T5-H5-1AC Kit
• Fluke T5-1000 Electrical Tester
• H5 Holster
• 1AC-II Volt Alert
Fluke T5-600/62/IAC-E Kit
• Fluke T5-600 Electrical Tester
• Fluke 62 Mini IR Thermometer
• Fluke 1AC-II Volt Alert
• C115 Soft Meter Case
Ordering Information
Fluke 287/FVF Fluke 289/FVF Fluke 1587/ET Fluke 1587/MDT Fluke T5-H5-1AC Kit Fluke T5-600/62/IAC-E Kit Fluke 62/322/1AC Kit Fluke 411D/62 Kit
Fluke 1587/ET Advanced Electrical Troubleshooting Kit
• Fluke 1587 Insulation Multimeter
• Fluke 62 Mini Infrared Thermometer
• I400 Current Clamp
Fluke 62/322/1AC Kit
• Fluke 62 Mini IR Thermometer
• Fluke 322 Clamp Meter
• Fluke 1AC-II Volt Alert
Fluke 411D/62 Kit
• Fluke 411D Laser Distance Meter
• Fluke 62 Mini IR Thermometer
• Soft case for each model
5
Page 8
Application/
riešenia na presné meranie
http://www.elso.sk
background articles
As part of our commitment to supporting you in your work we do more than just design and manufacture rugged and versatile test tools: we also provide application notes which all can be downloaded from our web site. Furthermore check out our “total solutions” campaigns on the website. In addition to inspection tips and helpful application information, these campaigns also offer advice on picking the right tool for the job.
6
Page 9
Let Fluke After Sales Service
riešenia na presné meranie
http://www.elso.sk
help you further
Did you know that the Fluke after sales service team can offer you much more than just repairing and calibrating your instrument when it is needed? Across our whole Fluke European service organization we have a vast range of capabilities, which can be utilized via your local service centre. Behind the scenes Fluke draws on the expertise of over 150 service staff that are focused on offering only the best and most comprehensive after sales service.
Fluke service centres handle a wide range of equipment.
As part of Fluke’s continuing focus on improving our service to our customer we now offer a comprehensive range of repairs and calibrations on a vast range of equipment. Fluke manufactures equipments such as:
Fluke Brands Instrument Types
Fluke Digital Multimeters
Hart Scientific Electrical Standards
Fluke Networks Biomedical Equipment
Fluke Biomedical Data Loggers
Raytek Thermal Imagers
Reliable Power Meters Thermometers
Robin Pressure
LEM Instruments Function Generators
BEHA Oscilloscopes
Norma Installation Testers
Wavetek/Datron PAT Testers
Metron Clamp Meters
DHI Power Analyzers
Comark EX meters
Plus many more
So why should you use Fluke service?
• Original manufacturers’ parts used
• All instruments reviewed for latest updates
• Repair warranty that covers whole unit
• In depth product knowledge
• Accredited calibrations available
• Traceable calibrations available on all products
• Full check of unit during verication cycle
• Full safety test on mains powered units
What other instruments can we help you with?
We also offer a range of calibrations and repairs on other manufacturer’s equipment upon request. Manufacturers such as:
• Tektronix
• Agilent
• Bruel & Kjaer
• Philips
• Megger
• Seaward
• Kewtech
• Lecroy
• Hioki
• Yokogawa
• Druck
• Iwatzu
• plus many more ...
Eindhoven Norwich Cologne
Telephone Telefax Email Address Science Park 5108
+31 (0)40 267 5300 +44 (0)1603 256620 +49 (0)69 2222 20210 +31 (0)40 267 5321 +44 (0)1603 256688 +49 (0)69 2222 20211 servicedesk@fluke.nl ukservicedesk@fluke.com
Eindhoven 5692 EC Son Netherlands
52 Hurricane Way Norwich Norfolk NR6 6JB United Kingdom
What other value added services do we offer?
• Gold Support for Fluke Networks
• Gold CarePlans for calibration products
• A full range of maintenance contracts
• Extended warranty programs
• Instrument upgrades
• Option retrots
• Asset management
• Calibration reminders
What services do we offer you?
• 5 day repairs on all current products
• 5 days or less on all calibrations (excl. repairs)
• 3 days for all Gold CarePlan calibrations
• 1-2 days on all Networks Gold calibration
• Pick up services where available
On-Line booking in system
Why not use our On-Line booking in system where you can book your unit in, get pricing and receive a RMA number for a smooth return.
www.uke.com/servicerma
Contact Information
servicedeskgermany@fluke.com
Heinrich-Pesch-Str. 9-11 50739 Köln Germany
7
Page 10
Fluke: Where safety is built in
riešenia na presné meranie
http://www.elso.sk
As distribution systems and loads become more complex, the possibilities of transient overvoltages increase. Motors, capacitors and power conversion equipment such as variable speed drives can be prime generators of spikes. Lightning strikes on outdoor transmission lines also cause extremely hazardous high-energy transients. If you’re taking measurements on electrical systems, these transients are “invisible” and largely unavoidable hazards. They occur regularly on low-voltage power circuits, and can reach peak values in the many thousands of volts. To protect you against transients, safety must be built into the test equipment.
Figure 1. Understanding categories: location
Who Develops Safety Standards?
The IEC (International Electrotechnical Commission) develops international general standards for safety of electrical equipment for measurement, control and laboratory use. IEC61010-1 is used as the basis for the following national standards:
• US ANSI/ISA-S82.01-94
• Canada CAN C22.2 No.1010.1-92
• Europe EN61010-1:2001
Overvoltage Installation Categories
IEC61010-1 species categories of overvoltage based on the distance the piece of equipment is from the power source (see Fig. 1 and Table 1) and the natural damping of transient energy that occurs in an electrical distribution system. Higher categories are closer to the power source and require more protection. Within each installation category there are voltage classications. It is the combination of installation category and voltage classication which determines the maximum transient withstand capability of the instrument.
IEC 61010 test procedures take into account three main criteria: steady-state voltage, peak impulse transient voltage and source impedance. These three criteria together will tell you a multimeter’s true voltage withstand value.
Within a category, a higher working voltage” (steadystate voltage) is associated with a higher transient, as would be expected. For example, a CAT III 600 V meter is tested with 6000 V transients while a CAT III 1000 V meter is tested with 8000 V transients. So far, so good. What is not as obvious is the difference between the 6000 V transient for CAT III 600 V and the 6000 V transient for CAT II 1000 V. They are not the same. This is where the source impedance comes in. Ohm’s Law (Amps = Volts/Ohms) tells us that the 2  test source for CAT III has six times the current
of the 12  test source for CAT II. The CAT III 600 V meter clearly offers superior transient protection compared to the CAT II 1000 V meter, even though its so-called “voltage rating” could be perceived as being lower. See Table 2.
Independent testing is the key to safety compliance
How can you tell if you’re getting a genuine CAT III or CAT II meter? Unfortunately it’s not always that easy. It is possible for a manufacturer to self-certify that its meter is CAT II or CAT III without any independent verication. The IEC (International Electrotechnical Commission) develops and proposes standards, but it is not responsible for enforcing the standards. Look for the symbol and listing number of an independent testing lab such as UL, CSA, VDE, TÜV or other recognized approval agency. These symbols can only be used if the product successfully completed testing to the agency’s standard, which is based on national and
international standards. UL 3111, for example, is based on EN61010-1. In an imperfect world, this is the closest you can come to ensuring that the meter you choose was actually tested for safety.
Overvoltage category In brief Examples
CAT IV Three-phase at utility connection,
CAT III Three-phase distribution, including
CAT II Single-phase receptable
CAT I Electronic
Overvoltage installation categories. IEC 61010-1 applies to low-voltage (< 1000V) test equipment
8
any outdoor conductors
single-phase commercial lighting
connected loads
Table 1
• Refers to the “origin of installation”; i.e., where low-voltage connection is made to utility power.
• Electricity meters, primary overcurrent protection equipment.
• Outside and service entrance, service drop from pole to building, run between meter and panel.
• Overhead line to d etached building, underground line to well pump.
• Equipment in xed installations, such as switchgear and polyphase motors.
• Bus and feeder in industrial plants.
• Feeders and short branch circuits, distribution panel devices.
• Lighting systems in larger buildings.
• Appliance outlets with short connections to service entrance.
• Appliance, portable tools, and other household and similar loads.
• Outlet and long branch circuits.
• Outlets at more than 10 meters (30 feet) from CAT III source.
• Outlets at more than 20 meters (60 feet) from CAT IV source.
• Protected electronic equipment.
• Equipment connected to (source) circuits in which measures are taken to limit transient overvoltages to an appropriately low level.
• Any high-voltage, low-energy source derived from a high-winding resistance transformer, such as the high-voltage section of a copier.
Page 11
Fluke: Where safety is built in
riešenia na presné meranie
http://www.elso.sk
Safety is everyone’s responsibility but ultimately it is in your hands. No tool by itself can guarantee your safety when working with electricity. It’s the combination of the right tools and safe work practices that gives you maximum protection. Here are a few tips to help you in your work:
Make sure you always comply with (local) regulations.
Work on de-energized circuits whenever possible.
Use proper lock-out/tag-out procedures. If these procedures are not in place or enforced, assume that the circuit is live.
Use protective gear when working on live circuits:
• Use insulated tools
• Wear safety glasses or a face shield
• Wear insulated gloves, remove watches or jewelry
• Stand on an insulated mat
• Wear ame resistant clothing, not ordinary work clothes
Select the right test tool:
• Choose a test tool rated to the highest category and voltage for which it could possibly be used (most often 600 or 1000 volt CAT III and/or 600 volt CAT IV).
• Look for the category and voltage marking near the recessed input connectors of your test tool and a “double insulated” symbol on the back.
• Verify your test tool has been tested and certied by two or more independent testing laboratories, such as UL in the United States and VDE or TüV in Europe by looking for the symbols of these agencies on (the back of) your test tool.
• Make sure that the test tool is made of a high-quality, durable non-conductive material.
• Check the manual to verify that the ohms, continuity and capacitance circuits are protected to the same level as the voltage test circuit, to reduce hazards when the test tool is used incorrectly in ohms, continuity or capacitance mode (if applicable).
• Verify that the test tool has internal protection to prevent instrument damage when voltage is incorrectly applied to an amperage measurement function (if applicable).
• Make sure that the amperage and voltage of your test tool’s fuses meets specications. Fuse voltage must be as high or higher than the test tool’s voltage rating.
• Be sure to use test leads that have:
- Shrouded connectors
- Finger guards and a non-slip surface
- Category ratings that equal or exceed
those of the test tool
- Double insulation (look for the symbol)
- A minimum of exposed metal on the
probe tips
Inspect and test your test tool:
• Check for a broken case, worn test leads or a faded display.
• Make sure the batteries still deliver sufcient power to get reliable readings. Many test tools have a low battery indicator on the display.
• Check the test leads resistance for internal breaks while moving the leads around (good leads measure 0.1-0.3 Ohm).
• Use the meter’s own test capability to ensure that the fuses are in place and working right (see manual for details).
Apply the appropriate working practices when measuring on live circuits:
• Hook on the ground clip rst, then make contact with the hot lead. Remove the hot lead rst, the ground lead last.
• Use the three-point test method, especially when checking to see if a circuit is dead. First test a known live circuit. Second, test the target circuit. Third, test the live circuit again. This veries that your test tool worked properly before and after the measurement.
• Hang or rest the test tool if possible. Try to avoid holding it in your hands, to minimize personal exposure to the effects of transients.
• Use the old electrician’s trick of keeping one hand in your pocket. This lessens the change of a closed circuit across your chest and through your heart.
Use protective equipment such as safety glasses and insulated gloves
Use meters with these markings: 1000 V CAT III or 600 V CAT IV
Overvoltage Installation
Category
CAT I 600 V 2500 V 30 Ohm source
CAT I 1000 V 4000 V 30 Ohm source CAT II 600 V 4000 V 12 Ohm source CAT II 1000 V 6000 V 12 Ohm source
CAT III 600 V 6000 V 2 Ohm source CAT III 1000 V 8000 V 2 Ohm source
CAT IV 600 V 8000 V 2 Ohm source
Transient test values for overvoltage installation categories. (50 V/150 V/300 V values not included)
Working Voltage
(DC or AC RMS
to ground)
Peak Impulse
Transient
(20 repetitions)
Table 2
Test Source
(Ω = V/A)
9
Page 12
Fluke Solution
riešenia na presné meranie
http://www.elso.sk
Fluke total solutions campaigns
Fluke has launched a total solutions campaign focused on all our products and the benets for you. Discover how Fluke tools can help you make or save money. You can nd a wide range of useful background information, www.ukesolution.co.uk
Plant Maintenance
Focus on motors and drives, energy saving and process trouble shooting, where Fluke’s Test & Measurement tools can help you make the difference. Learn more about our latest developments in for example inspecting motors and drives.
Thermography
Focus on the user experience of our Thermal Imagers and experience the wide-ranging benets of thermal imaging in everyday on­the-job situations. See what Fluke Thermography has to offer to make your work easier.
Energy
Focus on energy saving benets in the industrial maintenance market. Fluke Test & Measurement tools help you to detect problems and/or monitoring situations –prevention- before they become critical. Learn how we can help you make or save money in your plant or industry.
www.flukesolution.co.uk
10
Visit the full portal to get all your troubleshooting solutions from one source. Every Fluke tool is built around one idea…You!
Page 13
Digital Multimeters
riešenia na presné meranie
http://www.elso.sk
Safety, quality and performance: three words that sum up the benets of our extensive range of digital multimeters. Designed to help you do your job faster, more efciently and with greater accuracy, there is a model for every budget and application. Choose from handheld troubleshooters to ultra smart instruments packed with features, including the ability to log and graph data, as well as high-precision bench units.
11
Page 14
DMM Selection guide
riešenia na presné meranie
http://www.elso.sk
Loop calibration Insulation test
Auto-
motive
General
Purpose
(IP67)
Heavy duty
Basic Electrical
Field
Service
O
/
OO
/
OO
/
OO
/
OO
/
OO
/
OO
/
OO
/
OO
/
OO
/
OO
/
OO
/
/-
O
O
/
OO
/
OO
/
OO
O
OO
/
OO
/
OO
/
O
/-
/
O
OO
/
OO
/
OO
/
OO
/
O
OO
O
/-
OO
/
OO
/
/-
O
/-
O
/-
O
/-
O
/-
O
/-
O
/-
O
/-
O
/-
O
/-
O
/-
O
O
/
OO
-/
O
O
/
-/
O
/
OO
-/
O
/
OO
/
O
/-
O
/-
O
/-
O
/-
O
/-
OO
/
O
O
/
OO
/
O
/-
OO
/
O
3333
/-
OO
/
OO
/
OO
O
/-
O
/-
O
/-
O
/-
O
OOOO
Electrical HVAC/R
and field service
Industrial maintenance
High-end Industrial
display
Remote
289 287 233 87V 83V 179 177 175 117 116 115 114 113 27II 28II 77IV 88V 789 787 1587 1577
Highest accuracy
OO
/
OO
/
OO
/
OO
/
OO
/
OO
/
OO
/
OO
/
OO
/
O
OO
/
OO
/
OO
/
OO
/
OO
/-
/
O
OO
/-
/
OO
/
OO
OO
/
/
OO
OO
/
/
O
O
O
OO OO
O OO O
OO OO O
OO OO
OO OOOOOOOOOOOOOOO
/-
/-
O
OO
/-
/
O
OO
/-
/
O
OO
/-
/
O
OO
/-
/
O
OO
/-
/
O
O
O
O
O
O
O
/
OO
/
OOOOOOO OOOOOOOOOOOOO
O
O O
/
/
/
OO
OO
OO
/
/
/
OO OO OO OOO
O
O
O
OO O
OOO O
OO
/-
OO
/
OO
/
OO
/
O
/-
O
/-
OO OOOOOOO O OOO
OO
/
OO
/
OO
/
OOO OOO OO
OOOOOOOOOOOOOOOOOO OO
O
33333
OOOOO
3
OO
OO OO OO O
OO OOOOOOOOOOOOOOOOOO
OO OOOOOOOOOOOOOOOOOO
OOOOOOOOOOOOOOOOO OO
12
Basic features
Counts 50000 50000 6000 20000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 20000 6000 20000 4000 4000 6000 6000
True RMS readings AC+DC AC+DC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC
Basic DC accuracy 0.025% 0.025% 0.25% 0.05% 0.1% 0.09% 0.09% 0.15% 0.5% 0.5% 0.5% 0.5% 2.0% 0.1% 0.05% 0.3% 0.1% 0.1% 0.1% 0.09% 0.2%
Wide bandwidth 100 kHz 100 kHz 20 kHz 5 kHz 20 kHz 50 kHz
Auto/manual ranging
Measurements
Voltage AC/DC 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 600 V 600 V 600 V 600 V 600 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
Current AC/DC 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A 200 A 10 A 10 A 10 A 10 A 10 A 1 A 1 A 400 mA 400 mA
Resistance 500 MΩ 500 M 40 M 50 M 50 M 50 M 50 M 50 M 40 M 40 M 40 M 40 M 60 k 50 M 50 M 50 M 50 M 40 M 40 M 50 M 50 M
Frequency 1 MHz 1 MHz 50 kHz 200 kHz 200 kHz 100 kHz 100 kHz 100 kHz 50 kHz 50 kHz 50 kHz 200 kHz 200 kHz 100 kHz 200 kHz 20 kHz 20 kHz 100 kHz
Capacitance 100 mF 100 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF
Temperature +1350ºC +1350ºC +400ºC +1090ºC +400ºC +400ºC +1090ºC +1090ºC +500ºC
dB 60 dB 60 dB
Conductance 50 nS 50 nS 60 nS 60 nS 60 nS 60 nS 60 nS
Duty cycle/pulse width
, Non-contact voltage detection
TM
Motor drive measurement
4-20mA loop current as % readout
RPM/Dwell
VoltAlert
Continuity with beeper/Diode test
LoZ
TM
LoZ: low input impedance
VCHEK
Microamps
Insulation test
Number of insulation test ranges 52
Display
Warranty and safety
Lifetime warranty/warranty (years)
Dangerous voltage indication
Dual display
Analog bargraph
Backlight
Remote displayOData storage and exchange
Min-Max recording/with time stamp
Relative
Stand alone logging/TrendCapture
USB interface/RS232 interface
Readings memories 10000 10000
Other features
Source 4-20mA loop current/24V loop supply
Real time clock
Smoothing
Integrated holster
Removable holster
Closed case calibration
Seperate battry/fuse access
Completely sealed/watertight
Automatic power off
Fast Min-Max 250 µs 250 µs 250 µs 250 µs 250 µs
Display Hold/Auto (Touch) Hold
Automatic selection, AC/DC volts
Low battery indication
EN61010-1 CAT III 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 600 V 600 V 600 V 600 V 600 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
Input alert
EN61010-1 CAT IV 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V
See catalog page 13 13 14 15 15 16 16 16 17 17 17 17 17 18 18 19 20 111 111 37 37
Page 15
280 Series Digital Multimeters
riešenia na presné meranie
http://www.elso.sk
Fluke 289
Fluke 287
Precise performance View logged data graphically
on screen
Advanced diagnostic and logging functionality for maximizing productivity
Replacing the popular 180 Series, the Fluke 289 and Fluke 287 represent the next generation of high-performance industrial logging multimeters, including higher accuracy and greater troubleshooting convenience than ever before. With the ability to log data and review it graphically on the large display, you can solve problems faster and help minimize downtime, while working at several locations.
• Large 50,000 count 320 x 240 (1/4 VGA) dot matrix display
True-RMS measurements AC, AC+DC AC, AC+DC Bandwidth (voltage/current) 100 kHz / 100 kHz 100 kHz / 100 kHz Digital display counts (default/selectable) 50.000 / 50.000 50.000 / 50.000 Logging function with TrendCapture Records events and trends Internal memory Up to 180 h Up to 180 h Saves measurements Optical USB PC communications interface Low input impedance function (LoZ) Motor winding and low ohm measurement range 50  Low pass filter Field upgradeable/expandable meter Navigation keys F1-F4 soft keys/user function menus I-info button/on board help screens Multilingual interface Saves preferred measurement setups Current measurement: 20 A (30 seconds momentary; 10 A continuous) Peak capture (records transients as fast as 250 µs) Continuity measurement Min/Max/Average with Time Stamp (records signal fluctuations) IP Rating 54
• Logging function with TrendCapture for easy review of logged data
• Multiple readings per display provide more information at a glance
• “I”-info button for convenient on-board help
• PC interface for easy data transfer
In addition, the Fluke 289 provides:
• Lo Pass lter for motor drive measurements
• LoZ – Low impedance function prevents false “ghost voltage” readings
• 50  range for motor winding and low ohm measurements
Features
287 289
OO OO
OO OO
O
O OO OO OO OO OO OO OO OO OO OO OO
Included Accessories
TL175 test leads, AC172 alligator clips, probe holder, 6 AA batteries (installed), user manual, Calibration Certicate Sheet.
Ordering Information
Fluke 287 True-RMS Electronic logging multimeter with TrendCapture Fluke 289 True-RMS Industrial logging multimeter with TrendCapture Fluke 289/FVF Industrial logging multimeter and Software Combo Kit (see page 5) Fluke 287/FVF FlukeView Forms Combo Kit (see page 5) FVF-SC2 FlukeView Forms software including IR/USB cable
True RMS
Specifications
(Check the Fluke web for detailed specifications)
Functions Maximum Max. resolution 287 and 289**
Voltage DC 1000 V 1 µV ±(0.025% + 5) Voltage AC 1000 V 1 µV ±(0.4% + 40) Current DC 10 A 0.01 µA ±(0.15% +2) Current AC 10 A 0.01 µA ±(0.7% + 5) Temperature -200 ºC to 1350 ºC 0.1 ºC ±(1.0% + 1 ºC) Resistance 500 M 0.01  ±(0.05% + 2) Conductance 50 nS 0.01 nS ±(1.0% + 10) Capacitance 100 mF 0.001 nF ±(1.0% + 5) Frequency 1 MHz 0.01 Hz ±(0.005% + 1)
Accuracies are best accuracies for each function. ** 287 and 289 accuracy and resolution are stated for 50.000 counts
Battery life: 50 hours minimum, 180 hours in logging mode
Weig ht: 0,871 kg Lifetime warranty
Size (HxWxD): 222 mm x 102 mm x 60 mm
Recommended Accessories
TLK289
See page 123
TL910
See page 121
TLK287
See page 121
TPAK
See page 132
C280
See page 130
13
Page 16
233 Remote Display Multimeter
riešenia na presné meranie
http://www.elso.sk
Ultimate flexibility with removable display
Fluke 233
The Fluke 233 remote display digital multimeter allows you to be in two places at once. The removable display solves the problems of holding both the meter and the test leads to make a measurement, making measurements in hard-to-reach places, and making measurements in machines or panels that are physically separated from a limit
Removable magnetic display
True-RMS measurement
Digital display counts 6000
Display backlight
Built in thermometer
Resistance, continuity and diode test
Min/Max and average recording
Auto power off maximizes battery life
Radio transmitter automatically turns off when the display is connected to the meter
Use as conventional multimeter when the display is connected
Safety rating CAT IV 600 V / CAT III 1000 V
Auto and manual ranging
Display Hold and AutoHOLD
Unsafe voltage alert warns for voltages above 30V
2 Low batteries indication
Ergonomic case with integrated holster
Selectable sleep mode preserves battery life
®
switch or an isolator switch. Wireless technology allows the display to be carried up to 10 meters away from the point of measurement. The Fluke 233 is also designed to work in areas where the operator can’t be close to the active measurement point, like clean rooms or hazardous areas.
Features
233
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Included Accessories
Test leads with 4mm lantern tips, AC 172 alligator clips, 80BK-A temperature probe, CD-ROM, AA batteries and user manual.
Ordering Information
Fluke 233 Remote Display Multimeter
14
On all inputs
True RMS
Specifications
Functions
Voltage DC 1000 V 0.1 mV ±(0.25% + 2) Voltage AC 1000 V 0.1 mV ±(1.0% + 3) Current DC 10 A 1 mA ±(1.0% + 3) Current AC 10 A 1 mA ±(1.5% + 3) Resistance 40 M 0.1  ±(0,9% + 1) Capacitance 9999 F 1 nF ±(1,9% + 2) Frequency 50.00 kHz 0.01 Hz ±(0,1% + 2) Temperature -40 ºC to +400 ºC 0,1 ºC ±(1% + 10) Wireless frequency: 2.4 GHz ISM Band 10 meter range
Accuracies are best accuracies for each function
Battery Life: AA alkaline (3 for main body, 2 for display), 400 hrs typical
Maximum Max. Resolution Accuracy
Weig ht: 0.6 kg Three year warranty
Size (HxWxD): 193 x 93 x 53 mm
Fluke 233
Recommended Accessories
80AK-A
See page 128
80PK-9
See page 128
i410
See page 127
Tpak
See page 132
C35
See page 130
Page 17
80 Series V
riešenia na presné meranie
http://www.elso.sk
Digital Multimeters
Performance and accuracy for maximum industrial productivity
The Fluke 80 Series V have improved measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution, and electro-mechanical equipment.
The Fluke 87V has a unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment. A built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument. For 87V Ex see also page 118 and 119.
Features
Fluke 83V
Fluke 87V
83V/87V
On all inputs
True RMS
Fluke 87V Ex
not 87V Ex
Included Accessories
TL175 test leads, AC172 alligator clips, yellow holster (H80M excl. TPAK), 80BK temperature probe (87V only), 9 V battery (installed), CD-ROM (user’s manual and technical notes) and operator’s guide.
Ordering Information
Fluke 83V Multimeter Fluke 87V True RMS Multimeter Fluke 87V Ex Intrinsically safe True RMS multimeter Fluke 87V/E2 Industrial Electrician Combo Kit See page 4
True-RMS voltage and current for accurate measurements on non linear signals Bandwidth (voltage/current) 5 kHz 20 kHz
Digital display counts (default/selectable) 6000 20000 / 6000
Selectable filter for accurate voltage and frequency measurements on motor drives Large display with analog bargraph and 2 level bright white backlight Auto and manual ranging for maximum flexibility
Built-in thermometer lets you carry one less tool
Peak capture to record transients as fast as 250 µs
Relative mode to remove test lead resistance from low ohms measurements Min-Max-Average recording with Min/Max Alert to capture variations automatically AutoHOLD® to capture stable readings avoiding noisy signals Audible continuity, diode test and duty cycle
Input Alert
“Classic” design with new removable holster with built in test lead and probe storage Improved selectable sleep mode for long battery life
Easy battery exchange without opening the complete case
ATEX safety rating II 2 G Eex ia IIC T4
83V 87V / 87V Ex
OO
OO
OO
OO
OO
OO
OO
OO
OO
OO
O
O
O
O
87V Ex
Specifications
(Check the Fluke web for detailed specifications)
Functions Maximum Range 83V 87V/87V Ex*
Voltage DC 1000 V 0.1 mV ±(0.1%+1) 10 µV ±(0.05%+1) Voltage AC 1000 V 0.1 mV ±(0.5%+2) 10 µV ±(0.7%+2)
Current DC 10 A ** 0.1 µA ±(0.4%+2) 0.01 µA ±(0.2%+2)
Current AC 10 A ** 0.1 µA ±(1.2%+2) 0.01 µA ±(1.0%+2) Resistance 50 M 0.1  ±(0.4%+1) 0.01  ±(0.2%+1)
Conductance 60 nS 0.01 nS ±(1.0%+10) 0.001 nS ±(1.0%+10)
Capacitance 9999 µF 0.01 nF ±(1.0%+2) 0.01 nF ±(1.0%+2)
Frequency > 200 kHz 0.01 Hz ±(0.005%+1) 0.01 Hz ±(0.005%+1)
Temperature -200 to 1090 ºC - 0.1 ºC 1.0%
80BK temperature probe -40 to 260 ºC - - 2.2 ºC or 2%
Accuracies are best accuracies for each function. * 87V accuracy is stated for 6000 counts and resolution for 20000 counts ** 20 A up to 30 seconds
Battery Life: Over 400 hours typical (alkaline). Size (HxWxD):
200 mm x 95 mm x 48 mm
Max. resolution Accuracy
Weig ht: 0.6 kg 83V/87V: Lifetime Warranty 87V Ex: One Year Warranty
Max.
resolution
Accuracy
Recommended Accessories
(Not for hazardous zones)
C25
See page 130
TL238
See page 122
i410/i1010
See page 127
TPAK
See page 132
L215
See page 123
15
Page 18
170 Series Digital Multimeters
riešenia na presné meranie
http://www.elso.sk
Versatile meters for field service or bench repair
These meters have the features needed to nd most electrical, electro­mechanical and heating and ventilation problems. They are simple to use and have signicant improvements over Fluke’s original 70 Series like True-RMS, more measurement functions, conformance to the latest safety standards, and a much larger display that’s easier to view.
175 177 179
OOO
OOO
OOO
OOO
OOO
OOO
OOO
OOO
OOO
OOO
OOO
OOO
Fluke 179
Fluke 177
Fluke 175
True-RMS measurements AC AC AC
Digital display counts, updates 4 times per second 6000 6000 6000
Display backlight
Analog bargraph / 33 segments, updates 40 times per second Auto and Manual ranging
Display Hold and AutoHOLD®
Min-Max-Average recording mode with Min/Max Alert
Temperature readings (bead thermocouple probe included) Smoothing mode allows filtering of rapidly changing inputs Audible continuity and diode test
Test lead alert
Unsafe voltage alert warns for voltages above 30V
Low battery indication
Ergonomic case with integrated holster
Easy battery and fuse exchange without opening the complete case Selectable sleep mode preserves battery life
Features
OO
O
Included Accessories
Test leads with 4 mm lantern tips, installed 9V battery and users manual. The 179 also includes the 80BK temperature probe.
Ordering Information
Fluke 175 True RMS Multimeter Fluke 177 True RMS Multimeter Fluke 179 True RMS Multimeter Fluke 179/EDA2 Kit Electronics Combo Kit Fluke 179/MAG2 Kit Industrial Combo Kit See page 4
16
On all inputs
True RMS
Specifications
(Check the Fluke web for detailed specifications)
Functions Maximum Max. resolution 175 177 179
Voltage DC 1000 V Voltage AC 1000 V Current DC 10 A Current AC 10 A Resistance 50 M
Capacitance 10000 µF
Frequency
Temperature -40 ºC/+400 ºC 0.1 ºC
Accuracies are best accuracies for each function
100 kHz
Battery Life: Alkaline, 200 hrs typical Size (HxWxD): 190 mm x 85 mm x 45 mm
0.1 mV
0.1 mV
0.01 mA
0.01 mA
0.1  1 nF
0.01 Hz
±(0.15%+2) ±(0.09%+2) ±(0.09%+2)
±(1.0%+3) ±(1.0%+3) ±(1.0%+3) ±(1.0%+3) ±(1.0%+3) ±(1.0%+3) ±(1.5%+3) ±(1.5%+3) ±(1.5%+3) ±(0.9%+1) ±(0.9%+1) ±(0.9%+1) ±(1.2%+2) ±(1.2%+2) ±(1.2%+2) ±(0.1%+1) ±(0.1%+1) ±(0.1%+1)
Weig ht: 0.42 kg Lifetime Warranty
Recommended Accessories
i400
See page 126
C90
See page 130
TLK-220
See page 122
SV225
See page 133
±(1.0%+10)
i410-i1010
See page 127
Page 19
110 Series Digital Multimeters
riešenia na presné meranie
http://www.elso.sk
Fluke 115
Fluke 117
Fluke 114
Fluke 116
Fluke 113
On all inputs
True RMS
Included Accessories
Test leads with 4 mm lantern tips, holster, installed 9V battery and users manual
Ordering Information
Fluke 113 True RMS Multimeter Fluke 114 True RMS Multimeter Fluke 115 True RMS Multimeter Fluke 116 True RMS Multimeter Fluke 117 True RMS Multimeter Fluke 117/322 Kit Electricians Combo Kit (see page 4)
Compact design for ergonomic one-handed operation
The Fluke 110 Series has ve true-rms DMMs, each for specic users. The compact instruments offer convenient one-handed operation and a backlit display with large, easy­to-read digits.
Fluke 117 Electrician’s Multimeter with Non-Contact Voltage
The 117 is for electricians working in commercial and non-commercial premises (like hospitals and schools). It includes extras like non-contact voltage detection for faster and safer operation.
Fluke 116 Multimeter with Temperature and Microamps
The 116 is for heating, ventilation and air conditioning (HVAC) engineers. It includes temperature measurement and microamp current ranges to quickly troubleshoot HVAC problems.
True RMS readings
Counts
Backlight
Analog bargraph
AutoVolt: Automatic AC/DC voltage selection
VoltAlert™, Non-contact voltage detection
Built-in thermometer for HVAC applications
LoZ: low input impedance to prevent ghost voltage
VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity
Min/Max/Average to record signal fluctuations
Resistance, continuity
Frequency, Capacitance, Diode test
Microamps to test flame sensors
Display hold
Auto/manual ranging
Low battery indication
Compact case with removable holster
Functions Maximum Max. resolution 113 114 115 116 117
Voltage DC 600V 1mV Voltage AC 600V 1mV Current DC 10.00A 1mA Current AC 10.00A 0.01A Resistance 40M (113: 60K) 0.1 Capacitance 10000µF 1nF Frequency 50kHz 0.01Hz Temperature -40°C/+400°C 0.1°C VCHEK™ 600.0V AC/DC 0.1V
Accuracies are best accuracies for each function
Battery type: 9 volt Alkaline, 400 hours typical Size (HxWxD): 167 mm x 84mm x 46 mm
Fluke 115 Field Service Testing Multimeter
An everyday multimeter for technicians, the 115 is for electrical and electronic testing in eld service, industrial, and applications where more than the basic functions simplify work.
Fluke 114 Electrical Multimeter
The 114 is for electrical troubleshooting and straightforward ‘go/no-go’ in residential/ commercial testing. It has all the basic functions plus a special feature to prevent false readings caused by ghost voltage.
Fluke 113 Multimeter
The 113 is for basic electrical tests and repairing most electrical problems. Features include Fluke’s VCHEK™, added measurement functions, backlight and conformance to the latest safety standards.
Features
113 114 115 116 117
AC AC AC AC AC
6000 6000 6000 6000 6000
OOOOO
OOOOO
OOO
O
OOO
O
OOOOO
OOOOO
-/ O/
O
OOOOO
OOOOO
OOOOO
OOOOO
OOO
O
Specifications
(Check the Fluke web for detailed specifications)
±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2)
±(1.0%+3) ±(1.0%+3) ±(1.0%+3) ±(1.0%+3)
±(1.0%+3) ±(1.0%+3)
±(0.9%+2) ±(0.9%+1) ±(0.9%+1) ±(0.9%+1) ±(0.9%+1)
±(1.9%+2) ±(1.9%+2) ±(1.9%+2) ±(1.9%+2)
±(2.0%+3)
±(1.5%+3) ±(1.5%+3)
±(0.1%+2) ±(0.1%+2) ±(0.1%+2)
±(1.0%+10)
Weig ht: 0.55 kg (including batteries) Three Year Warranty
Recommended Accessories
O
C50
See page 130
TL223-1
See page 122
MC6
See page 133
TPAK
See page 132
17
Page 20
27II / 28II Rugged IP67 Industrial
riešenia na presné meranie
http://www.elso.sk
Multimeters
Designed to survive water, dust and rough handling and yet troubleshoot most electrical problems
Fluke 27 II
The Fluke 27 II and 28 II digital multimeters dene a new standard for operating in harsh conditions with the features and accuracy to troubleshoot most electrical problems. Both meters have IP 67 (waterproof and dustproof) rating, MSHA approvals, extended operating temperature range of -15° C to + 55°C and 95% humidity, and a 3-meter drop. They withstand hazardous 8.000 volt spikes caused by load switching and
Features
IP 67 waterproof & dustproof protection
Withstands 3 meter drop (with holster)
True-RMS measurements
Digital display counts 6000 20000/6000
Bright, two-level backlight
Backlit keypad buttons
Reversible, rubber holster
Built-in thermometer
Resistance, continuity and diode test
Min/Max and average recording
Improved sleep mode for long battery life
Relative mode to remove test lead resistance from low ohms measurements
Auto and manual ranging
Safety rating CAT III 1000 V
faults on industrial circuits and complies with second edition IEC and ANSI electrical safety standards. Furthermore, the 28 II has a unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment. The new Fluke 20 series multimeters are built to work in the toughest environments.
27 II 28 II
CAT IV 600 V
OO
OO
O
OO
OO
OO
O
OO
OO
OO
OO
OO
CAT III 1000 V
CAT IV 600 V
Included Accessories
TL175 Test leads, AC172 alligator clips, 80BK-A temperature probe (28 II), holster, manual, CD-ROM, three AA batteries (installed)
Ordering Information
Fluke 27 II IP 67 Industrial Multimeter
18
Fluke 28 II IP 67 True-RMS Industrial Multimeter
Fluke 28 II
On all inputs
True RMS
Specifications
Functions Maximum
Voltage DC 1000 V 0.1 mV ±(0.1% + 1) ±(0.05% + 1) Voltage AC 1000 V 0.1 mV ±(0.5% + 3) ±(0.7% + 4) Current DC 10 A 0.1 A ±(0.2% + 4) ±(0.2% + 4) Current AC 10A 0.1 A ±(1.5% + 2) ±(1.0% + 2) Temperature -200°C to
Resistance 50M 0.1 ±(0.2% + 1) Low pass filter (Measurement on VSD’s) yes Capacitance 9999µF 0.01nF ±(1% + 2) Frequency 200 kHz 0.01 Hz 0.005% + 1 Peak transient capture 250 S
Accuracies are best accuracies for each function
Battery Life: 3x AA alkaline, 800 hrs typical Size (HxWxD): 198 x 100 x 63.5 mm
+1090°C
Weig ht: 0.75 kg Lifetime Warranty
Max.
Resolution
0.1°C ±(1% + 10)
27 II 28 II
Recommended Accessories
PV 350
See page 125
i200
See page 126
i410
See page 127
80K-6
See page 133
Page 21
77IV Digital Multimeter
riešenia na presné meranie
http://www.elso.sk
Versatile multimeter for field service or bench repair
The 77-IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has signicant improvements over Fluke’s original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that’s easier to view.
Digital display counts Large display with backlight Min-Max-Average recording mode with Min/Max Alert High contrast digital display with large digits Analog bargraph/segments Auto and Manual ranging Automatic Touch Hold® Audible continuity / diode test Ergonomic case with integrated holster Sleep Mode preserves battery life EN 61010-1 safety rating
Features
77 IV
6000
O
O
O
31
O
O
O
O
O
CAT IV 600 V / CAT III 1000 V
Fluke 77 IV
On all inputs
Included Accessories
Test leads with 4mm lantern tips, operator’s manual, 9V battery (installed)
Function Maximum Max. resolution Accurancy
Voltage DC 1000 V 1 mV ±(0.3%+1) Voltage AC 1000 V 1 mV ±(2.0%+2)
Current DC 10 A 0.01 mA ±(1.5%+2)
Current AC 10 A 0.01 mA ±(2.5%+2) Resistance 50 M 0.1  ±(0.5%+1)
Capacitance 9999 µF 1 nF ±(1.2%+2)
Frequency 99.99 kHz 0.01 Hz ±(0.1%+1)
Accuracies are best accuracies for each function.
Battery Life: 400 hours typical Size (HxWxD): 185 mm x 90 mm x 43 mm
Weight: 0.42 kg Lifetime Warranty
Recommended Accessories
Specifications
Ordering Information
Fluke 77IV Multimeter
i400
See page 126
C35
See page 130
Tpak
See page 132
TL225
See page 133
TLK-225
See page 123
19
Page 22
Fluke 88V/A
riešenia na presné meranie
http://www.elso.sk
88V Automotive Meter
The right meter for auto-electric diagnosis
Perhaps the most important tool you’ll use in troubleshooting auto electrical systems is the multimeter. Basic multimeters measure voltage, current and resistance, while automotive multimeters like the Fluke 88V have features that can check frequency, duty cycle, make diode tests, and measure temperature, pressure and vacuum.
Continuity for detecting open and shorts
Frequency for “pulsed-DC” and AC tests
Duty cycle to verify operation of feedback carburetors
Diode test for alternator testing
Built-in thermometer; thermocouple probe included
Min/Max/Average recording with Min/Max Alert
Peak capture to record transients as fast as 250 µs
Relative mode to remove test lead resistance from low ohms measurements
Millisecond pulse width measurements for fuel injectors
AutoHOLD® to capture stable readings
Large display with bright, two-level backlight
Magnet hanger to attach meter to the vehicle
RPM80 Inductive Pickup for both conventional and distributorless (DIS) ignitions
Hard Meter Case
Safety rating CAT III 1000 V,
Features
88V/A
O
O
O
O
O
O
O
O
O
O
O
O
O
O
CAT IV 600 V
Included Accessories
H80M Holster with TPAK Meter Hanging Solution, TL224 SureGrip Silicone Test Lead Set, TP74 Test Probe Set, AC285 SureGrip Large Jaw Alligator Clip Set, 80BK Integrated Temperature Probe, RPM80 Inductive Pick-up Probe, C800 Hard Case, User’s Manual + Quick Reference Guide
Ordering Information
Fluke 88V/A Automotive Meter Combo Kit
20
On al inputs
Specifications
Voltage DC 1000V 0.1mV 0.1% Voltage AC 1000V (5 kHz) 0.1mV 0.5% Current DC 10A 0.1µA 0.4% Current AC 10A 0.1µA 1.2% Resistance 50MΩ 0.1Ω 0.4% Capacitance 10mF 0.01nF 1% Frequency 200kHz 0.01Hz 0.01% Temperature 1090ºC 0.1ºC 1%
Battery Life: 88V – Over 400 hours typical (alkaline)
Range Resolution Accuracy
Weig ht: 88V – 0.36 kg Lifetime Warranty
Size (HxWxD): 88V – 186 mm x 86 mm x 32 mm
Fluke 88V
Recommended Accessories
TL82
See page 125
TLK-282-1
See page 125
90i-610s
See page 125
80PK-27 (requires 80AK)
See page 128
PV350
See page 125
Page 23
8845A/8846A
riešenia na presné meranie
http://www.elso.sk
6.5 Digit Precision Multimeters
Precision and versatility for bench or systems applications
Fluke 8845A
The Fluke 8845A and 8846A, 6.5 digit precision multimeters have the precision and versatility to handle your most demanding measurements on the bench or in a system.
Dual Display offers versatile graphical capabilities: The 8845A and 8846A
features a unique graphical display that can reveal signal quality issues like drift, intermittent and stability by viewing the measurement data as a real time TrendPlot™, Histogram or Statistics using the unique analyze mode. Wide Measurement Ranges: Resistance or current has been extended to cover the widest range possible.
Perform 4-wire measurements easily with two leads: Patented split terminal
jacks for 2x4 Ohms function allows you to perform precise 4-wire measurements with only two leads instead of four. Optional Kelvin leads accessories are available to enable you to establish a 4­wire connection even in tight spaces. Systems Capabilities: Both instruments include an RS-232, IEEE-488 and Ethernet interface as standard, with popular DMM emulation modes makes systems integration a simple task. Software: Transfer data points from your meter to your PC with the free copy of FlukeView Forms Basic. To customize your forms upgrade with FVF-UG.
Fluke 8846A
Use the built-in TrendPlot paperless chart recorder to graphically identify the extent of drift and intermittent events in analog circuits
View results in Histogram mode to reveal stability or noise problems in analog circuits
Handle even the most demanding measurements with high accuracy and 6.5 digit resolution
True RMS
Included Accessories
LCI Line Power Cord, Test Lead Set, Spare Line Power fuse, Programmers Manual/ User Manual on CD-ROM, 884X-USB USB to RS232 Cable Adapter, FVF-BASIC FlukeView Forms Software Basic Version.
Ordering Information
Fluke 8845A 6.5 Digit Precision Multimeter Fluke 8845A/SU 6.5 Digit Precision Multimeter (software + cable) Fluke 8846A 6.5 Digit Precision Multimeter Fluke 8846A/SU 6.5 Digit Precision Multimeter (software + cable) Calibration & Service agreements
Features
Display Resolution Measurement Rate (Rdgs/s) Continuity / Diode Test Analytical Functions Math Functions USB Device Port Real Time Clock Interfaces Programming Languages/
Emulation Modes Safety Designed to comply with IEC 61010-12000-1, ANSI / ISA-S82.01-1994, CAN /
8845A 8846A
Statistics, Histogram, TrendPlot™, Limit Compare
CSA-C22.2 No.1010.1-92 1000V CATI / 600V CATII
Dual VFD Dot Matrix
6.5 Digits 1000
Yes
NULL, Min/Max, dB/dBm – USB Memory Drive port –Yes
RS232, IEEE-488.2, Ethernet
SCPI (IEEE-488.2), Agilent 34401A, Fluke 45
Specifications
(Check the Fluke web for detailed specifications)
Function*
Voltage DC Voltage AC (Freq 300 Hz) Resistance (2x4 Wire) Current DC Current AC (Freq. 3Hz-10kHz) Freq/Period Capacitance Temperature RTD
* Accuracy =+/- (% of reading)
Size (HxWxD): 88 mm x 215 mm x 293 mm Weig ht: 3.6 kg Three Year Warranty
1000 V 100 nV 0.0035 1000 V 100 nV 0.0024
100 MΩ 100 µΩ 0.01 1 GΩ 10 µΩ 0.01
300 kHz 1 µHz 0.01 1 MHz 1 µHz 0.01
8845A 8846A
Range Resolution Accuracy* (%) Range Resolution Accuracy* (%)
750 V 100 nV 0.06 1000 V 100 nV 0.06
10 A 100 pA 0.05 10 A 100 pA 0.05 10 A 10 µA 0.10 10 A 100 pA 0.10
- - - 1 nF to 100 mF 1 pF 1
- - - -200 to +600º 0.001º 0.06
Recommended Accessories
884X-case
Hard case
TL2X4W-TWZ
2x4 Wire Ohms Tweezer
Test Leads
TL2X4W-PT II
2x4 Wire Ohms Test lead 2mm Probe Tip
884X-512M
USB Memory 512M
FVF-UG
FlukeView Forms Software Upgrade
21
Page 24
8808A 5.5 Digit Multimeter
riešenia na presné meranie
http://www.elso.sk
Fluke 8808A
The Fluke 8808A includes two low impedance low current ranges for measuring sensitive leakage currents
Use setup keys (S1-S6) for fast access to repetitive measurements. Setups can include limit compare mode with pass/fail indicators
Versatile multimeter for manufacturing, development and service applications
Manufacturing test, R&D, development and service applications demand performance and exibility from a bench meter. The Fluke 8808A delivers a wide variety of measurement functions, including volts, ohms, and amps, plus frequency - all at superior accuracy and resolution with a basic V dc accuracy of
0.015 %.
Measure sensitive leakage current: The Fluke 8808A includes two low impedance low current ranges for measuring sensitive leakage currents (i-Leakage).
Perform routine manufacturing functional tests with consistency:
Use setup keys (S1 – S6) for fast access to repetitive measurements. Operators no longer need to press multiple buttons to make routine measurements.
Display Resolution Measurements Advanced Measurements Continuity / Diode Test Analytical Functions Math Functions Interfaces Programming Languages/Modes Safety Rating
Eliminate production mistakes: The 8808A has a limit compare mode with built in display enunciators that clearly show whether a test is within or out of limits.
Perform 4-wire measurements with only two leads: Patented split terminal
jacks for 2x4 Ohms function allow you to perform precise 4-wire low ohms measurements with only two leads instead of four. Optional test lead accessories are available to enable you to establish a 4-wire connection even in tight spaces or on surface mount devices.
Features
8808A
VFD multi segment
5.5 digits
V ac, V dc, I dc, I ac, Ω, Cont, Diode
2X4 Wire Ohms, Freq, i-Leakage
Yes
Limit Compare
dBm, dB, Min, Max
RS-232, USB via optional adapter
Simplified ASCI, Fluke 45 CAT I 1000 V, CAT II 600 V
Dual Display
Included Accessories
LCI Line Power Cord, Test Lead Set, Spare Line Power fuse, 884X-USB USB to RS232 Cable Adapter, FlukeView Forms Software Basic Version, Programmers Manual/User Manual on CD-ROM.
Ordering Information
Fluke 8808A 5.5 digit multimeter Fluke 8808A/SU 5.5 digit multimeter, (software & cable) Fluke 8808A/TL 5.5 digit multimeter, 2X4W Test Lead Kit
22
True RMS
Specifications
(Check the Fluke web for detailed specifications)
Voltage DC 200 mV to 1000 V 1 µV 0.015 Voltage AC
(Freq. 10 Hz to 100 kHz) Resistance (2x4 Wire) 200 Ω to 100 MΩ 1 mΩ 0.02
Current DC 200 µA to 10 A 1 nA 0.02
Current AC (Freq. 20 Hz to 2 kHz) Freq. Period 20 Hz to 1 MHz
* Accuracy = +/- (% of reading)
Size (HxWxD): 88 mm x 217 mm x 297 mm Weig ht: 2.1 kg Three year Warranty
Functions Range Resolution Accuracy*
200 mV to 750 V 1 µV 0.2
20 mA to 10A 0.1 µA 0.3
(Freq. only)
0.1 mHz 0.01
Recommended Accessories
TL2X4W-TWZ
2x4 Wire Ohms Tweezer
Test Leads
884X-case
Hard case
TL2X4W-PT II
2x4 Wire Ohms Test lead 2mm Probe Tip
884X-short
4-Wire Short
FVF-UG/SC4/SC5
FlukeView Forms
Software
Page 25
Clamp Meters and
riešenia na presné meranie
http://www.elso.sk
Electrical Testers
The ergonomic clamp meters feature wide opening jaws for safe, fast non-contact current measurement. The Fluke leakage clamp meter is ideal for non-invasive checks of insulation resistance. The range of electrical testers includes two-pole testers for taking quick measurements in tight spaces, phase rotation indicators to take the guess work out of checking phase/motor rotation, a multipurpose cable locator and handy voltage alerts. The new Fluke iFlex exible current probes expand the measurement range of select Fluke meters to 2500 A ac and allow technicians to reach crowded spaces.
23
Page 26
Clamps Selection Guide
riešenia na presné meranie
http://www.elso.sk
Leakage
360*
iFlex
accessory
utility
High end industrial,
i2500-18
OO
1 %
± 5 counts
3 %
± 5 counts
1.5 % ± 5 counts
1.5 % ± 5 counts
2 %
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
1,5 %
± 5 counts
1,5 %
± 5 counts
1 %
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
1 %
± 5 counts
1 %
± 5 counts
1,5 %
± 5 counts
1,5 %
± 5 counts
1 %
± 5 counts
1 %
± 5 counts
1 %
± 5 counts
1 %
± 5 counts
1
CAT III 30 0 V
CAT IV 60 0 V
CAT III 1000 V,
CAT IV 60 0 V
CAT III 1000 V,
CAT IV 60 0 V
CAT III 60 0 V CAT III 100 0 V,
CAT IV 60 0 V
CAT III 1000 V,
CAT IV 60 0 V
CAT III 1000 V,
General purpose Industrial electrical HVAC/R
electrical
OOOOOOOOOOOOO
OOOOOOOOO O
321 322 365 373 374 375 376 381 902 353 355 i2500-10/
Residential/commercial
OOO OOO
OOOOOOOO
O OOOOOOO
OOOOOOOOOO
OOOOOOOO O
OOOOOOOOO O
OOOOOOOOO O
OOO OO
OOOO OOO
OOOOOO
OOOOOOOOO O
OOOOOOOOOOO O
2 %
2 %
2 %
2 %
1.8 %
1.8 %
± 5 counts
± 5 counts
± 5 counts
± 5 counts
± 5 counts
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
1,5 %
± 5 counts
1,5 %
± 5 counts
1 %
± 5 counts
2 %
± 5 counts
1.2 % ± 5 counts
1.2 % ± 5 counts
1 %
± 5 counts
1 %
± 5 counts
1 %
± 5 counts
2 %
± 5 counts
1 %
± 5 counts
CAT IV 60 0 V
CAT III 1000 V,
CAT IV 60 0 V
CAT III 1000 V,
CAT IV 30 0 V
OO OOOOOOOO O
24
Measurements
AC current
AC volts
Resistance
Continuity
DC Volts
DC current
True-rms
Frequency
AC + DC voltageOAC + DC current
Min/Max/Avg
TemperatureOCapacitance
Special features
Inrush current mode
Low Pass filter
Harmonics, power, data logging
18-inch iFlex Flexible Current Probe Optional Optional Included Included
10-inch iFlex Flexible Current Probe Optional Optional Optional Optional
Remote displayOFlashlight/torchODisplay
Display hold
Backlight
Graphing display
Specifications
Jaw opening 25.4 mm 25.4 mm 18 mm 32 mm 34 mm 34 mm 34 mm 34 mm 30.5 mm 58 mm 58 mm 7.5 mm coil 40 mm
Current range ac rms 0 to 400.0 A 0 to 400.0 A 0 to 200.0 A 0 to 600.0 A 0 to 600.0 A 0 to 600.0 A 0 to 999.9 A 0 to 999.9 A 0 to 600.0 A 0 to 1400 A 0 to 1400 A 0 to 2500 A 0 to 60 A
Accuracy ac current (50/60 Hz)
AC Response Averaging Averaging True-rms True-rms True-rms True-rms True-rms True-rms True-rms True-rms True-rms True-rms Averaging
Current range dc 0 to 200 A 0 to 60 0.0 A 0 to 600.0 A 0 to 999.9 A 0 to 999.9 A 0 to 200 A 0 to 2000 A 0 to 2000 A
Accuracy dc current
Voltage range ac 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 1000 V 0 to 1000 V 600.0 V 0 to 600.0 V
Accuracy ac voltage
Voltage range dc 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 1000 V 0 to 1000 V 0 to 600.0 V 0 to 1000 V
Accuracy dc voltage
Resistance range 0 to 400  0 to 40 0  0 to 6000  0 to 6000  0 to 6000  0 to 600 0  0 to 60 k 0 to 60 k 0 to 9999  0 to 400 k
Frequency measurement range 500 Hz 500 Hz 500 Hz 5 to 1000 Hz 5 to 1000 Hz 500 Hz
Unit power
Category ratings (EN61010-1) CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V,
Warranty and safety
Warranty (years) 2 2 3 3 3 3 3 3 3 3 3 3
Auto off
Page 27
New
riešenia na presné meranie
http://www.elso.sk
381 Remote Display True-rms
AC/DC Clamp Meter with iFlex
All the bells and whistles
The Fluke 381 Clamp Meter combines iFlex exibility with remote reading capability for the ultimate in innovation and safety.
• Remote display reads measurements up to 30 feet away
• iFlex exible current probe included, 18-inch circumference
• 2500 A ac current measurement with iFlex
• 1000 A ac and dc current measurement with xed jaw
• 1000 V ac and dc voltage measurement
• Frequency measurement to 500 Hz
• 60 k resistance measurement
• Min/Max/Avg and inrush recording
• CAT IV 600 V, CAT III 1000 V
True RMS
• Three-year warranty
See specications chart on page 24.
True-rms AC/DC Clamp Meter
New
Included Accessories
18-inch iFlex™ Flexible Current Probe (Fluke
381), test leads, soft carrying case, instruction card, safety information sheet, two AA alkaline batteries.
365 Detachable Jaw
Where rugged meets reliable
The Fluke 365 Clamp Meter offers a small, detachable jaw—with four feet of coil—that makes it easy to take and read measurements in tight or hard-to-reach places.
• 200 A ac and dc current measurement
• 600 V ac and dc voltage measurement
• 6000  resistance measurement
• Built-in ashlight
• Large, easy-to-read backlight display
• Three-year warranty
True RMS
See specications chart on page 24.
Recommended Accessories
Ordering Information
Fluke 381 Remote Display True-rms AC/DC Clamp Meter with iFlex Fluke 365 Detachable Jaw True-rms AC/DC Clamp Meter
TL223-1
See page 122
TL175
See page 124
25
Page 28
New
riešenia na presné meranie
http://www.elso.sk
Fluke 376
(with i2500)
370 Series Clamp Meters
Be ready for anything
Our new family of true-rms clamp meters provides a range of state of-the­art features to meet even the most demanding job requirements. All four of the new clamp meters have improved base features such as a large, backlit display, true-rms standard, CAT IV
True-rms AC current AC voltage Resistance Continuity DC volts DC current Frequency Low pass filter Inrush current mode 18-inch iFlex Flexible Current Probe Optional Optional Included 10-inch iFlex Flexible Current Probe Optional Optional Optional
safety rating and a durably constructed body. Additionally, the 376, 375 and 374 are compatible with the iFlex exible current probe (included with the 376, sold separately for the 375 and 374), and provide increased measurement readings to 1000 A and 1000 V ac and dc.
373 374 375 376
OOOO
OOOO
OOOO
OOOO
OOOO
OOOO
Features
OOO
OO
OO
OOO
Fluke 375
Fluke 374 Fluke 373
Fluke i2500
True RMS
Included Accessories
18-inch iFlex™ exible current Probe (Fluke
376), test leads, soft carrying case, instruction card, safety information sheet, two AA alkaline batteries.
Specifications
Functions Range 373 374 375 376
Current AC 0 to 600.0 A 2% ± 5 counts 2% ± 5 counts 2% ± 5 counts
Current DC 0 to 600.0 A 2% ± 5 counts 2% ± 5 counts
Voltage AC 0 to 600.0 V 1% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts Voltage DC 0 to 600.0 V 1% ± 5 counts 1% ± 5 cou nts 1% ± 5 counts
Resistance range 0 to 6000  0 to 6000  0 to 60 00  0 to 60 k Jaw opening 32 mm 34 mm 34 mm 34 mm Max. wire size 750 MCM 750 MCM 750 MC M 75 0 MCM Frequency measurement range 500 Hz 500 Hz
iFlex
Flexible Current Probe
The new Fluke iFlex exible current probes expand the measurement range of select Fluke meters to 2500 A ac and allow technicians to reach crowded spaces.
• Expands the measurement range to 2500 A ac while providing increased display exibility, ability to measure awkward sized conductors and improved wire access
• Compatible to Fluke 374, 375, 376 and 381
• CAT IV 600 V, CAT III 1000 V
• 7.5 mm coil diameter allows measurement in tight spaces
• Ergonomic design allows easy operation with one hand
• 1.8 m (6 ft) cable
• Three-year warranty
0 to 999.9 A 2% ± 5 counts
0 to 999.9 A 2% ± 5 counts
0 to 1000 V 1% ± 5 counts
Ordering Information
Fluke 376 True-rms AC/DC Clamp Meter with iFlex Fluke 375 True-rms AC/DC Clamp Meter Fluke 374 True-rms AC/DC Clamp Meter Fluke 373 True-rms AC Clamp Meter i2500-10 iFlex™ Flexible Current Probe 25 cm (10 in) i2500-18 iFlex™ Flexible Current Probe 45 cm (18 in)
26
Recommended Accessories
TL223-1
See page 122
AC285
See page 124
TL175
See page 124
Page 29
320 Series Clamp Meters
riešenia na presné meranie
http://www.elso.sk
Get more done
The Fluke 321 and 322 are designed to verify the presence of load current, ac voltage and continuity of circuits, switches, fuses and contacts. These small and rugged clamp meters are ideally suited for current measurements up to 400 A in tight cable environments.
• Precised measurements with 1.8 % basic accuracy
True-rms AC current AC voltage Resistance Continuity DC volts DC current Min/Max/Avg
Fluke 321Fluke 322
Temperature Capacitance
• Resolution up to 0.01 A and 0.1 V
• Measures ac current 40.00 A/400.0 A
• Measures ac and dc volts to 600 V
• Resistance measurement to 400 
• Continuity for quick checking of shorts
See specications chart on page 24 for details per model.
Features
321 322 902
O
OOO
OOO
OOO
OOO
OO
O
O
O
O
902 True-rms HVAC Clamp Meter
Just for our HVAC pros
• Small body and jaws t perfectly in your hand and into tight places
• Handy “Display Hold” button keeps measurements on the display
• Meter controls are positioned so current measurements can be done with one hand (index nger on clamp opening lever and thumb on rotary switch)
• Three-year warranty
See specications chart on page 24.
0 to 600.0 A 2% ± 5 counts
600.0 V 1% ± 5 counts
Fluke 902
True RMS
HVAC (heating, ventilation, air conditioning) technicians require a service tool that can consistently keep up with their demands. The Fluke 902 expands the existing line of quality Fluke clamp meters by delivering the features necessary to diagnose and repair HVAC systems. Combined with true-rms technology and a CAT III 600 V rating, the Fluke 902 helps technicians do their jobs safely and accurately.
• Designed for HVAC applications with capacitance, dc current (A), and temperature measurements
Functions Range 321 322 902
Current AC 0 to 4 00.0 A 1.8% ± 5 counts 1.8% ± 5 counts
Current DC 0 to 200.0 A 1% ± 5 counts Voltage AC 0 to 600.0 V 1.2% ± 5 counts 1.2% ± 5 counts
Voltage DC 0 to 600.0 V 1% ± 5 cou nts 1% ± 5 counts Resistance range 0 to 400  0 to 400  0 to 9999  Jaw opening 25.4 mm 25.4 mm 30.5 mm Max. wire size 500 MCM 500 MCM 750 MCM
Specifications
Included Accessories
Test leads, temperature probe (Fluke 902), soft carrying case, instruction card, safety information sheet, two AA alkaline batteries.
Ordering Information
Fluke 321 Clamp Meter Fluke 322 Clamp Meter Fluke 902 True-rms HVAC Clamp Meter
TL223-1
See page 122
Recommended Accessories
TL175
See page 124
LVD2
See page 32
See page 131
H3
27
Page 30
350 Series AC/DC Clamp Meters
riešenia na presné meranie
http://www.elso.sk
True-RMS, 2000 A Clamp Meters for industrial and utility applications
Fluke 353
Condently take reliable readings with the true-rms, Fluke 353/355 Clamp Meters; the tools of choice for high current measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high current applications. The rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of protection when taking high-powered measurements.
Features
True-RMS measurements Display backlight Motor start-up current Min/Max/Average Voltage AC/DC Resistance measurement Continuity measurement with beeper
Accurate peak measurements can be taken using the in-rush current mode ­ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this the most versatile tool for utilities, electrical contractors and industrial service technicians.
353 355
OO
OO
OO
OO
O
O
O
Fluke 355
True RMS
Included Accessories
Fluke 353: C43 Soft Meter Case, 6 AA batteries, users manual Fluke 355: C43 Soft Meter Case, 6 AA batteries, TL224 SureGrip
®
Silicone Test Lead Set, TP2 Slim Reach Test Probe Set (2 mm), AC285 SureGrip® Alligator Clip Set, users manual
Ordering information
Fluke 353 AC/DC Clamp Meter Fluke 355 AC/DC Clamp Meter
Specifications
(Check the Fluke web for detailed specifications)
Functions Range 353 355
Current AC/DC 0-40.00 A 1.5% ± 15 counts 1.5% ± 15 counts
Crest Factor 2.4 2.4 Voltage AC/DC 0-4.000 V 1% ± 10 counts
Resistance 0-400.0 
Continuity beeper Appr. ≤ 30  Frequency 5.0Hz to 100.0Hz 0.2% ± 2 counts
Power Supply: 6 x 1.5V AA NEDA 15A or IEC LR6 Battery Life: 100 hours (with typical usage, backlight off )
0-400.0 A 0-2000 A; 1400 AC rms
0-40.00 V 0-400.0 V 0-600 V AC rms 0-1000 V DC
0-4.000 k 0-40.00 k 0-400.0 k
100.1Hz to 999Hz 0.5% ± 5 counts
1.5% ± 5 counts 1.5% ± 5 counts
1% ± 5 counts
1.5% ± 5 counts
Size (HxWxD): 300 mm x 98 mm x 52 mm
Jaw opening: 58 mm Weig ht: 0.814 kg Two year warranty
Recommended Accessories
28
TL223-1 (Fluke 355)
See page 122
L215 (Fluke 355)
See page 123
Page 31
360 Leakage Clamp Meter
riešenia na presné meranie
http://www.elso.sk
Leakage current measurements with a tough, pocket sized clamp meter
The Fluke 360 is ideal for non-invasive checks of insulation resistance. The unique jaw design eliminates the inuence of adjacent current conductors. The ergonomic design of the Fluke 360 ensures easy measuring. The measuring clamp ts into tight spaces and the wide display angle clearly shows the measurement result. The data hold button keeps the measured value on the display after removing the clamp for the measured conductor.
The light Fluke 360 offers the widest range of current measurement for maintenance professionals and contractors.
Features
• Measurement of leakage protectives conductor and touch current with a resolution of 1µA
• Advanced shielding to ensure accurate results when measuring near other conductors
• Automatic ranging within the manually selected mA or A range
• Easily viewed measurements on digital and bargraph display and HOLD when measuring in hard to see locations
• Broad range of measurements currents up to 60 A for all installation needs
• Easy carrying, pocket sized clamp with wide 40 mm jaw size
• Display-Hold for convenience in use
• Auto power off with audible warning buzzer
• Conformance to IEC61010 and EMC standard
• Meets all the applications and performance classes in safety standard VDE0404-4 and the new VDE0702
Fluke 360
Included accessories
Soft carrying pouch and users manual
Ordering information
Fluke 360 Leakage Clamp Meter
Specifications
(Check the Fluke web for detailed specifications)
Functions Range Resolution Accuracy
Current AC
Frequency 50 and 60Hz
Battery type: 3 Volt Lithium, 90 hours typical Size (HxWxD): 176 mm x 70mm x 25 mm Weig ht: 0.2kg One Year warranty
leakage current 0.5mA
3mA 30mA 30A 60A
0.001A
0.01mA
0.01A
0.1A
display: 1.7mA
1% ± 5 counts 1% ± 5 counts (0~50A)
5% ± 5 counts (50~60A)
ground
leakage current
1.2mA (e.g. via motor shaft)
29
Page 32
T100 Series
riešenia na presné meranie
http://www.elso.sk
Voltage and Continuity Testers
The fast and easy solution to voltage, continuity and phase rotation testing
Fluke T140
Fluke T120
Fluke T100
The fast and easy solution to voltage, continuity and resistance measurements. Ideal for site conditions, the 3 models of the T100 Series 2-pole testers have a rugged construction and ergonomically formed housing for perfect handling. All models offer a patented three-phase rotation detection system providing quick phase rotation indication.
Display LCD LCD Led Bargraph 12 LED’s 12 LED’s 12 LED’s Backlight Resistance measurement Switchable load Voltage test Optical and acoustical continuity test Rotary field indication Single pole test for phase detection Indication of polarity Electrical torch function Probe tip protection The voltage display also functions when using
discharged - or o batteries
Moreover they have a special electrical torch function for working in low light level environments and have an ingress protection rating of IP65. The T100 Series are compliant with EN 61010-1 and EN61243-3 requirements.
T100 T120 T140
OOO
OOO
OOO
OOO
OOO
OOO
OOO
OOO
Features
O
O
O
Included Accessories
Two 1.5V batteries and instruction sheet
Ordering Information
Fluke T100 Voltage/Continuity Tester Fluke T120 Voltage/Continuity Tester Fluke T140 Voltage/Continuity Tester
UK versions are compliant with GS38
30
Specifications
Voltage AC/DC 12 - 690 V 12 - 690 V 12 - 690 V Continuity 0 - 400 k 0 - 400 k 0 - 400 k Frequency 0 - 400 Hz 0 - 400 Hz 0 - 400 Hz Phase rotation 100 to 690 V 100 to 690 V 100 to 690 V Resistance measurement - - Up to 1999  Response time < 0.1 s < 0.1 s < 0.1 s
Size (HxWxD): 240 mm x 56 mm x 24 mm Case: IP65 (water-jet and dust tight protection) Weig ht: 180 g Two year warranty
T100 T120 T140
Recommended Accessories
C33 (T100 Series)
See page 130
Page 33
Fluke T5-1000
riešenia na presné meranie
http://www.elso.sk
(incl. TP1-1 test probes)
T5 Electrical Testers
Fluke T5-600
(incl. TP1-1 test probes)
The fast and easy solution to basic electrical testing
The Fluke T5 testers let you check voltage, continuity and current with one compact tool. Select volts, ohms or current and the instrument does the rest. Model T5-600 measures 600 volts AC/DC, model T5-1000 is designed for 1000 volts. OpenJaw™ current technology lets you check current up to 100 A, without breaking the circuit. The optional H5 holster keeps the test probes and leads ready to test and lets you clip the T5 onto your belt.
Features and Specifications
Display Count 1000 1000 Automatic Selection Continuity and Bleeper Sleep Mode AC Voltage 600 V 1000 V DC Voltage 600 V 1000 V AC Current 100 A 100 A Resistance 1000  1000  Safety range 600V CAT III 1000 V CAT III / 600 V CAT IV
T5-600 T5-1000
OO
OO
OO
Fluke T5-H5-1AC Kit
Fluke T5-600/62/1AC-E Kit
Included Accessories
2 TP38 detachable probe (CAT III), 2 TP1-1 detachable probe (CAT II), (detachable GS38 probes for the UK) and instruction sheet
Ordering Information
Fluke T5-600 Electrical Tester Fluke T5-1000 Electrical Tester Fluke T5-H5-1AC Kit Electrical Tester with holster and IAC Fluke T5-600/62/1AC-E Electrical Tester, IR Thermometer, Voltage Detector Kit
Battery life: 400 hours Size (HxWxD):
203 mm x 51 mm x 30.5 mm
Fluke T5-H5-1AC Kit
The ideal kit for busy electrical contractors and electricians. The benets of a voltage and current meter and non­contact voltage detector all in one kit. A holster for the T5 is also included.
Kit includes:
- Fluke T5-1000
- H5 holster
- Free Fluke 1AC-II
Weig ht: 0.38 kg Two year warranty
Fluke T5-600/62/1AC-E Kit
This kit is designed to help electricians and HVAC technicians solve problems quicker. Test rst for overheated electrical devices using an IR thermometer; then use elecrtrical test tools to nd out more about the problem.
Kit includes:
• Fluke T5-600
• Fluke 62
• Fluke 1AC II
• C115
Recommended Accessories
H5
See page 131
ACC-T5-Kit
See page 123
AC285
See page 124
31
Page 34
Fluke 1AC II
riešenia na presné meranie
http://www.elso.sk
Fluke 2AC VoltAlert
1AC II/2AC Volt Alerts
LVD1/LVD2 Volt Lights
Fluke 1AC II VoltAlert™
The Fluke VoltAlert AC voltage detector is very easy to use – just touch the tip to a terminal strip, outlet or cord. When the tip glows red and the unit beeps, you know there is voltage on the line.
• It continually tests its battery and its circuit integrity with a periodic double ash visual indication.
• Highest safety rating: CAT IV 1000 V
• Detects voltage without metallic contact
2AC VoltAlert™
2AC is the latest addition to the VoltAlert™ ac non- contact voltage tester family from Fluke and is designed to be pocket-sized and easy to use. The 2AC tests for energized circuits and defective grounds, whether it’s for an electrician on the factory oor or the do-it­yourselfer around the house. The tip of the pocket-sized tester will glow red when within close proximity of an outlet, terminal strip, or power cord where voltage is present.
• Voltage detection from 200 to 1000 V ac, suitable for a wide range of residential, commercial and industrial needs.
• NEW! Always on, using special low power
circuitry to sustain battery life and ensure your 2AC is always ready.
• NEW! Innovative ‘Battery Check’ button function ensures battery is in good condition*
• Category IV – 1000 V overvoltage rated product for best in class user protection
• Integrated clip design, optimized for pocket storage
• Powered by 2x AAA batteries (included)
• Fluke ruggedness and reliability
• Two-year warranty storage.
• Powered by 2x AAA batteries (included)­Fluke reliability and ruggedness, Two-year warranty.
Operating range: 200 – 1000 V AC Batteries: Two AAA Alkaline Size (H): 148 mm Two Year Warranty
Fluke 1AC II VoltAlert™ 5-pack
• Buy 4 get 1 FREE
Operating range: 200 – 1000 V AC Batteries: Two AAA Alkaline Size (H): 148 mm Two Year Warranty
Fluke 2AC VoltAlert™ 5-pack
• Buy 4 get 1 FREE
Features
2AC 1AC-II LVD2
200-1000 V AC CAT IV 1000 V
200-1000 V AC
CAT IV 1000 V
90-600 V AC
CAT IV 600 V
Ordering Information
Fluke 1AC II Volt Alert Fluke 1AC II Volt Alert (5-pack) Fluke 2AC Volt Alert Fluke 2AC Volt Alert (5-pack) LVD2 Volt Light LVD1 Volt Light
32
LVD2
LVD1
LVD2 Volt Light
Combines bright light and voltage detection in one pen style design
• Dual sensitivity
• Detects voltage from 90 V to 600 V AC
• Blue light means you’re close
• Red light means you’re at the source
• Rated to CAT IV 600 V
LVD1 Volt Light
Dual sensitivity voltage detector
• Detects voltage from 40 V to 300 V AC
• Blue light means you’re close
• Red light means you’re at the source
• Comes with a versatile clip to secure light to pocket, hat or even panel door
Voltage Detection
Battery Included
Battery Check
On/Off Button
Voltbeat™
Audible/Silent
Dual Sensitivity
LED Flashlight
Page 35
9040/9062
riešenia na presné meranie
http://www.elso.sk
Phase Rotation Indicators
Take the guess work out of phase/motor rotation measurements
Fluke 9040
The Fluke 9040 is effective for measuring phase rotation in all areas where three-phase supplies are used to feed motors, drives and electrical systems. The Fluke 9040 is a rotary eld indicator and can provide clear indication of the 3 phase via an LCD display and the phase rotation direction to determine correct connections. It allows rapid determination of phase sequence and has a voltage (up to 700 V) and frequency range suitable for commercial and industrial applications. Test probes supplied with the instrument have a variable clamping range for safe contact, especially in industrial sockets.
Fluke 9062
The unique Fluke 9062 provides rotary eld and motor rotation indication with the benets of contact-less detection. Purpose made for commercial and industrial environments, the Fluke 9062 provides rapid indication of 3 phase rotation using test leads supplied or can be used to determine motor rotation on synchronous and asynchronous 3 phase motors. The contact-less detection is ideal for use on motors where the shaft is not visible. Test probes supplied with the instrument have a variable clamping range for safe contact, especially in industrial sockets.
Fluke 9040
Fluke 9062
9040:
9062:
Included Accessories
Fluke 9040: Alligator clips - black (3) Standard test probes - black (3) Flexible test probes - black (3) Fluke 9062: Alligator clips - black (3) Flexible test probes - black (3) Test leads - black (3)
Ordering Information
Fluke 9040 Phase Rotation Indicator Fluke 9062 Motor and Phase Rotation Indicator
Features
3 phase indication Via LCD Via LED Indication of phase rotation Indication of motor rotation direction Contact free determination of the rotation direction of running motors Clear LCD display No battery required
9040 9062
OO
O
O
O
O
Specifications
Voltage range 40 - 700 V Up to 400 V Phase display - 120 - 400 V AC Frequency range 15 - 400 Hz 2-400 Hz Operating time Continuous Continuous
Size (HxWxD) Fluke 9040:
124 mm x 61 mm x 27 mm
Size (HxWxD) Fluke 9062:
124 mm x 61 mm x 27 mm
9040 9062
Power supply 9040: from unit under test Power supply 9062: 1 x 9V Weig ht 9040: 0.20 kg Weig ht 9062 : 0.15 kg Two Year Warranty
Fluke 9062 Applications
Determine the presence of phase sequence of multiphase electrical supplies.
Determine the rotation of running motors simply by placing the instrument on the motor casing.
Check the correct rotation of motors prior to connection.
Recommended Accessories
TLK290
See page 123
TLK291
See page 123
C25
See page 130
33
Page 36
Receiver
riešenia na presné meranie
http://www.elso.sk
Fluke 2042
Transmitter
2042 Cable Locator
The multipurpose solution to cable location
The Fluke 2042 is a professional general purpose cable locator. It is ideal for tracing cables in walls and underground, locating fuses/breakers on nal circuits and locating interruptions and short­circuits in cables and electrical oor heating systems. It can also be used for tracing metallic water and heating pipes. The unit is supplied as a complete kit comprising of a transmitter and receiver in a purpose­made carry case. The receiver also incorporates a torch function for working in dimly lit locations.
• For all applications (live or dead cables) without additional instruments
• Set includes a transmitter and a receiver
• Proven digitally coded sender signal guarantees clear signal identication
• Transmitter with LCD-display for transmitting level, transmitting code and external voltage
Voltage Measurement Range 12V, 50V,120V, 230V, 400V Frequency Range 0..60 Hz Output signal 125 kHz Voltage Up to 400V AC/DC Tracing depth cable location 0...2.5m wall/underground
Main voltage detection 0...0.4m
• Receiver with a backlight LCD-display for level of receiving signal, code of receiving signal and live voltage indication
• Automatic or manual adjustment of receiving signal sensitivity
• Switchable acoustic receiving signal
• Auto-Power-Off
• Additional torch lamp function for working in dark environments
• Additional transmitters are available for extension or to distinguish between several signals.
Transmitter Receiver
Specifications
cables
34
Included Accessories
TL27 Heavy Duty Test Lead Set (2) TP74 Lantern Tip Test Probe Set AC285 Alligator Clip Set Soft carrying case Hard case
Ordering Information
Fluke 2042 Cable Locator (transmitter + receiver) Fluke 2042T Cable Locator Transmitter
Batteries Transmitter: 6 pc Batteries 1.5V Batteries Receiver: 1 pc Battery 9V Size (HxWxD) Transmitter:
190 mm x 85 mm x 50 mm
Size (HxWxD) Receiver:
250 mm x 65 mm x 45mm
Weig ht Locator: 0.45 kg Weig ht Receiver: 0.36 kg Two Year Warranty
Location of fuses/breakers and assignment to circuits
Tracing of underground cables (max. depth 2.5 m)
Fluke 2042 applications
Precise location of cable interruptions with additional transmitter
Recommended Accessories
Fluke 2042T
Page 37
Insulation Testers and
riešenia na presné meranie
http://www.elso.sk
Earth Ground Testers
With a 10kV insulation resistance tester and a range of compact hand­held instruments, we offer a solution for every troubleshooting and preventive application. Two of the digital hand-held insulation testers also include full-featured multimeters. The Fluke Earth Ground Testers can perform all four types of earth ground measurement, including stakeless testing with earth ground loop resistances using only clamps.
35
Page 38
Insulation Tester
riešenia na presné meranie
http://www.elso.sk
Selection Guide
InstallationTest Functionality
Test voltages 500V, 1000V 50V, 100V, 250V,
Insulation Resistance Test Range 0.1M - 600M 0.01 M - 2G 0.01M - 100M 0.1M - 2G 0.01M - 10G 200K - 1T 200K - 2T Polarization Index/Dielectric
Absorption Ratio Auto Discharge
Time Ramp test (Breakdown) Pass/Fail Comparison Estimated Number of
Insulation resistance Tests Voltage > 30V Warning
Memory (99 locations) (99 locations) Remote Test Probe Lo Ohms Display Digital LCD Digital LCD Digital LCD Digital LCD Digital LCD Digital LCD / Analog
Continuity
Multimeter Functionality
AC/DC Volts Current Resistance Temperature (contact) Lo-Pass Filter Capacitance Diode Test Frequency MIN/MAX
Other
Hold/Lock Backlight
Software
Warranty (in years) 3 331133
Battery
1577 1587 1587T 1503 1507 1550C 1555
500V, 1000V
OOOOOOO
1000 1000 1000 1000 1000 1000 @ 5000 V 1000 @ 10000 V
OOOOOOO
OOOOO
OOO
OOOOO
OOO
OOOOO
OOOOOOO
OOOOO
4 AA (NEDA 15A or
IEC LR6)
OO
OO
OO OO
OO
OO
OO
4 AA (NEDA 15A or
IEC LR6)
50V, 100V 500V, 1000V 50V, 100V, 250V,
OO
(200mA) (200mA)
4 AA (NEDA 15A or
IEC LR6)
4 AA (NEDA 15A or
IEC LR6)
500V, 1000V
4 AA (NEDA 15A or
IEC LR6)
OOO
O
250V, 500V, 1000V,
2500V, 5000V
OO
Bar Graph
(Fluke View® Forms
Basic)
Rechargeable Rechargeable
250V, 500V, 1000V,
2500V, 5000V, 10000V
Digital LCD / Analog
Bar Graph
(Fluke View® Forms
Basic)
Fluke 1587/ET
36
Fluke 1587/MDT
Buy a Fluke 1587 Combo Kit and save
Fluke 1587/ET Advanced Electrical Troubleshooting Kit
This kit contains:
• Fluke 1587 Insulation Multimeter
• Fluke 62 Mini Infrared Thermometer
• i400 Current Clamp
Perform insulation tests with the Fluke 1587 plus a wide-range of DMM tasks with condence and ease. Use the i400 with your Fluke 1587 to accurately measure AC current without breaking the circuit. Check for hot spots and measure temperature with the Fluke 62 Mini non-contact thermometer.
Fluke 1587/MDT Advanced Motor & Drive Troubleshooting Kit
This kit contains:
• Fluke 1587 Insulation Multimeter
• Fluke 9040 Phase Rotation Indicator
• i400 Current Clamp
Perform insulation tests with the Fluke 1587 plus a wide-range of DMM tasks with condence and ease. Use the i400 with your Fluke 1587 to accurately measure AC current without breaking the circuit. Check the phase­rotation of three-phase motors easily and safely with the Fluke 9040.
Page 39
Fluke 1577
riešenia na presné meranie
http://www.elso.sk
1577/1587
Insulation Multimeters
Two powerful tools in one
The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured True RMS digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventive maintenance.
Multimeter Features 1577 1587 1587T
True RMS Voltage and Current for accurate measurements Digital display counts 6000 6000 6000 Autorange and manual range for easy testing. Selectable filter for accurate voltage and frequency measurements on motor
drives Min Max Recording, Diode test, temperature, capacitance & frequency measurement for maximum flexibility.
Insulation features
User selectable test voltages for many applications Additional test voltages 50V, 100V, 250V Special remote control probe for easy and safe measurements Auto-discharge of capacitive voltage for added user protection Live circuit detection prevents insulation test if voltage > 30V is detected for
added user protection
General features
Auto Power off to save batteries
Fluke 1587
Fluke 1587T
Large display with backlight Input Alert to warn for incorrect connections Continuity
Whether you work on motors, generators, cables, or switch-gear, the Fluke 1587/1577 Insulation Multimeters are ideally suited to help you with your tasks.
The Fluke 1587T is specially designed for the telecom environment.
Features
OOO
OOO
OO
OO
OO
O
OOO
OOO
OOO
OOO
OOO
OOO
OOO
Included Accessories
C101 Rugged, utility hard case TL224 SureGrip Silicone Test Lead Set AC285 SureGrip Alligator Clip Set 80BK Integrated DMM Temperature Probe (Type K) TP165X Remote Test Probe
Ordering Information
Fluke 1577 Insulation Multimeter Fluke 1587 Insulation Multimeter Fluke 1587T Insulation Multimeter (for Telecom)
Insulation Specifications
Functions 1577 1587 1587T
Measurement range 0.1M to 600M 0.01M to 2G 0.01M to 100M Test voltages 500V, 1000V 50V, 100V, 250V, 500V,
Test voltage accuracy + 20%, -0% + 20%, -0% + 20%, -0 % Insulation test current 1mA nominal 1 mA nominal 1 mA nominal Auto discharge Discharge time < 0.5s
Maximum capacitive load Up to 1 µF load Up to 1 µF load Up to 1 µF load
for C = 1 µF or less
1000V
Discharge time <0.5s for C = 1 µF or less
50V, 100V
Discharge time <0.5s for C = 1 µF or less
Multimeter Specifications
Functions Maximum Max. resolution 1577 1587/1587T
Voltage DC 1000V 1 mV ± (0.2% + 2) ± (0.09% + 2) Voltage AC 1000V 0.1mV ± (2% + 3) ± (2% + 3) Current DC 400mA 0.01mA ± (1.0% + 2) ± (0.2% + 2) Current AC 400mA 0.01mA ± (2% + 2) ± (1.5% + 2) Resistance 50.0MΩ 0.1Ω ± (1.2% + 2) ± (0.9% + 2) Capacitance 9999µF 1 nF - ± (1.2% + 2) Frequency 99.99kHz 0.01 Hz - ± (0.1% + 1) Temperature -40°C to +537°C 0.1°C - ± (1% + 10)
Battery life: Meter: 1000 hrs, Insulation Test: >1000 tests
Size (HxWxD):
Weig ht: 0.55 kg Three Year Warranty
203 mm x 100 mm x 50 mm
Recommended Accessories
C25
See page 130
i400
See page 126
TPAK
See page 132
L215
See page 123
TL238
See page 122
37
Page 40
Fluke 1503
riešenia na presné meranie
http://www.elso.sk
1503/1507 Insulation Testers
Truly portable insulation resistance testers
When you need a low cost solution to general purpose insulation testing look no further than the new Fluke insulation tester range. The Fluke 1507 and 1503 Insulation Testers are compact, rugged, reliable and easy to use.
User selectable test voltages for many applications Additional test voltages 50V, 100V, 250V Special remote control probe for easy and safe measurements Auto-discharge of capacitive voltage for added user protection Live circuit detection prevents insulation test if voltage > 30 V
is detected for added user protection Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio Auto Power off to save batteries
Large display with backlight Continuity function (200 mA) Compare function (pass/fail) for fast repetitive tests
The multiple test voltages on both models make them ideal for many troubleshooting, commissioning and preventive maintenance applications. Additional features like the remote probe save both time and money when performing tests.
Features
1503 1507
OO
O
OO
OO
OO
O
OO
OO
OO
O
Fluke 1507
Included Accessories
TP165x Remote Test Probe TL224 SureGrip Silicone Test Lead Set TP74 Lantern Tip Test Probe Set Alligator clips
Ordering Information
Fluke 1503 Insulation Tester Fluke 1507 Insulation Tester
Specifications
Insulation specifications 1503 1507
Insulation test range 0.1 MΩ to 2 GΩ 0.01 MΩ to 10 GΩ Test voltages 500 V, 1000 V 50 V, 100 V, 250 V, 500 V, 1000 V Test voltage accuracy + 20 %, - 0 % + 20 %, - 0 % Insulation test current 1mA nominal 1mA nominal AC/DC Voltage measurement 600 V (0.1 V resolution) 600 V (0.1 V resolution) Resistance measurement range 0.01 Ω to 20 kΩ 0.01 Ω to 20 kΩ Auto discharge Discharge time < 0.5 second
Maximum capacitive load Up to 1 µF Up to 1 µF Open circuit test voltage > 4 V , < 8 V > 4 V , < 8 V Short circuit current > 200 mA > 200 mA
Battery life: Insulation Test: > 1000 tests Size (HxWxD):
203 mm x 100 mm x 50 mm
for C = 1 µF or less
Weig ht: 0.55 kg One Year Warranty
Discharge time < 0.5 second
for C = 1 µF or less
Fluke 1503/1507 Applications
Insulation test at a distribution panel
Wiring test in a small distribution box – all in one spot
38
C101
See page 131
PAK
See page 132
Recommended Accessories
TLK 225
See page 123
AC285
See page 122
L210
See page 133
Page 41
1555/1550C
riešenia na presné meranie
http://www.elso.sk
Insulation Resistance Testers
New
Fluke 1555 Fluke 1550C
Included accessories
Test Cables with Alligator Clips (red, black, green) Infrared adapter with interface cable FlukeView Forms Basic CD-ROM AC Power Cord Soft Carrying Case (base models only) English Manual Users Manual on CD-ROM Quick Reference Card Software License Agreement Registration Card FlukeView Forms Installation Guide USB-IR Cable Installation Guide IP67 Hard Case (kit only) Certicate of Calibration (kit only) Ruggedized Alligator Clips (kit and 1555 only)
Software specifications
Fluke ViewForms basic software requires a PC running Windows 2000, Windows XP and Windows Vista.
Digital insulation testing up to 10kV
The new 1555 and redesigned Fluke 1550C insulation resistance testers offer digital insulation testing up to 10kV, making them ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables. Fluke insulation testers can now conduct the entire range of test voltages specied in IEEE 43-2000 with a best in class, 3-year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, the 1555 and 1550C are perfect tools for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.
• Test voltages up to 10 kV (1555) provides solutions for all applications
• CAT III 1000 V, CAT IV 600 V safety rating
• Voltage breakdown detection alerts the user that voltage is present and gives the voltage reading up to 600 V ac or dc for increased user safety
Test voltage (dc) Range Accuracy (± reading) 250 V < 200 k
500 V < 200 k
1000 V < 200 k
2500 V < 200 k
5000 V < 200 k
10000 V (1555 only) < 200 k
Bar Graph Range 0 to 1 T & 0 to 2 T (1555 only) Insulation test voltage accuracy -0 %, +10 % at 1 mA load current
Induced ac mains current rejection
Charging rate for capacitive load 5 seconds per F
Discharge rate for capacitive load
Leakage current measurement 1 nA to 2 mA ± (5% + 2 nA) Capacitance measurement 0,01 uF to 15,00 F ± (15% rdg + 0,03 µF)
Timer Range Resolution
Live circuit warning Warning range Voltage accuracy
200 k to 5 G 5 G to 50 G > 50 G
200 k to 10 G 10 G to 100 G > 100 G
200 k to 20 G 20 G to 200 G > 200 G
200 k to 50 G 50 G to 500 G > 500 G
200 k to 100 G 100 G to 1 T > 1 T
200 k to 200 G 200 G to 2 T > 2 T
0 to 99 minutes Setting: 1 minute
30 V to 660 V ac/dc, 50/60 Hz ± (15% + 2 V)
• Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
• Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user dened, label for easy recall
• Long battery life gives the user over 750 tests between charges
• Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
• Guard system eliminates the effect of surface leakage current on high­resistance measurements
• Large digital/analog LCD for easy viewing
• Capacitance and leakage current measurement
• Ramp function for breakdown testing
• Resistance measurements up to 2T
• Timer settings up to 99 minutes for timed tests
• 3-year warranty
Specifications
(Check the Fluke web for detailed specifications)
unspecified 5 % 20 % unspecified unspecified 5 % 20 % unspecified unspecified 5 % 20 % unspecified unspecified 5 % 20 % unspecified unspecified 5 % 20 % unspecified unspecified 5 % 20 % unspecified
2 mA maximum
1,5 s/F
Range Accuracy
Indication: 1 second
Optional Accessories
TL1550EXT 25 Foot Extended Test Lead Set
Ordering information
Fluke 1550C 5 kV Insulation Tester Fluke 1555 10 kV Insulation Tester Fluke 1550C/Kit 5 kV Insulation Tester Kit Fluke 1555/Kit 10 kV Insulation Tester Kit
Temperature (operating):
-20 °C to 50 °C ( -4 °F to 122 °F)
Temperature (storage):
-20 °C to 65 °C (-4 °F a 149 °F) Humidity: 80 % to 31 ºC decreasing linearly to 50 % at 50 ºC
Enclosure sealing: IP40 Altitude: 0 to 2000 m Power: 12 V lead-acid rechargeable battery,
Yuasa NP2.8-12
Dimensions: 170 mm x 242 mm x 330 mm Weig ht: 3,6 kg (7,94 lb) 3-year warranty
39
Page 42
1620 Series
riešenia na presné meranie
http://www.elso.sk
Earth Ground Testers GEO
Advanced technology for all your earth ground testing applications
Fluke 1623
Fluke 1625
The new Fluke 1620 Series Earth Ground Testers not only measure ground resistance using the classic ‘fall of potential test’ but also enable time saving testing using the ‘selective’ and ‘stakeless’ methods. ‘Selective’ testing does not require the electrode under test to be disconnected during the measurement, thus increasing safety. The simple ‘stakeless’ method quickly checks ground connections using two current transformers (probes) clamped around the ground conductor under test. Offering ‘one-button’ simplicity, the 1623 is an all-in-one earth ground tester, while the 1625 has extra versatility for more demanding applications.
One-button measurement concept 3- and 4-pole earth ground measurement 4-Pole soil resistivity testing 2-Pole resistance measurement AC 2-and 4-pole resistance measurement DC Selective testing, no disconnection of ground conductor (1 clamp) Stakeless testing, quick ground loop testing (2 clamps) Measuring frequency 128 Hz Earth impedance measurement at 55 Hz Automatic frequency control (AFC) (94 – 128 Hz) Measuring voltage switchable 20/48V Programmable limits, settings Continuity with buzzer Dust/water resistance IP56 IP56 Safety rating CAT II 300 V CAT II 300 V
Earth ground resistance and soil resistivity should be measured when:
• Designing earth ground systems
• Installing new ground system and electrical equipment
• Periodically testing ground and lightning protection systems
• Installing large electrical equipment such as transformers, switchgears, machines, etc.
Features
1623 1625
O
OO
OO
O
O
OO
OO
O
O
O
O
O
O
Included accessories
Fluke 1623: Protective holster, 2 test leads, 2 alligator clips, users manual Fluke 1623 Kit: same as above plus stake/reel Set 4 pole and selective/stakeless clamp set Fluke 1625: Protective holster, 2 test leads, 2 alligator clips, users manual Fluke 1625 Kit: same as above plus stake/reel set 4 pole and selective/stakeless clamp set
Ordering information
Fluke 1623 Basic GEO Earth Ground Tester Fluke 1623 Kit Basic GEO Earth Ground Tester Kit Fluke 1625 Advanced GEO Earth Ground Tester Fluke 1625 Kit Advanced GEO Earth Ground Tester Kit
40
Fluke 1625 kit
Specifications
(Check the Fluke web for detailed specifications)
Resistance ranges 0 to 20 k 0 to 300 k Operating error ± 5% ± 5% Test voltage 48 V 20 / 48 V Short circuit current > 50mA 250 mA
Battery type: 6 x AA alkaline cells Size (HxWxD): 110 mm x 180 mm x 240 mm Weight – 1623 Geo: 1.1 kg (including batteries) 1625 Geo: 1.1 kg (including batteries) Two Year Warranty
1623 1625
Recommended Accessories
EI-1623
Selective/stakeless clamp
set for 1623
EI-1625
Selective/stakeless clamp
set for 1625
ES-162P3
Stake/reel set for 3 pole
measurements
ES-162P4
Stake/reel set for 4 pole
measurements
EI-162BN
320mm Split core
transformer for selective
measurements on high
voltage pylons
Page 43
1621 Earth Ground Tester
riešenia na presné meranie
http://www.elso.sk
Handheld earth ground testing for mobile use
The Fluke 1621 is an easy-to-use earth ground tester. The rst line of defense in detecting reliable ground connections, the unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance. Its convenient size, rugged holster, and large, clear LCD display make it an ideal eld earth tester, for most work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy tool for electrical contractors, utility test engineers, and earth ground specialists.
Features
• 3-pole Fall-of-Potential earth testing for basic measurements
• 2-pole resistance measurements for added versatility
• Easily capture values with single-button operation
• Ensure accurate measurements with automatic ‘noise’ voltage detection
• Hazardous voltage warning offers increased user protection
• Clearly read and record data with a large, backlit display
• Rugged holster and design for tough work environments
• Portable size allows for easy transportation
• Instantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting
• Safety rating CAT II 600 V
Fluke 1621
Included accessories
Two measuring leads with alligator clips ­2 m, protective holster, users manual, CD-ROM
Specifications
(Check the Fluke web for detailed specifications)
1621
Resistance range 0.15  to 2 k Basic accuracy ± 6% of measured value + 5D Operating error according EN61557 ± 18% of measured value +5D Test voltage 23 to 24 V AC Short circuit current > 50 mA AC
Battery type: 1 x 9 V alkaline (LR61) Size (HxWxD): 216 mm x 113 mm x 54 mm Weig ht: 0.850 kg Two Year Warranty
Recommended Accessories
Ordering information
Fluke 1621 Earth Ground Tester
GEO CABLE-REEL 25M
Ground Earth Cable Reel
25 M Wire
GEO CABLE-REEL 50M
Ground Earth Cable Reel
50 M Wire
GEO EARTH STAKE
Ground Earth Stake
ES-162P3
Stake/reel set for 3 pole
measurements
41
Page 44
1630 Earth Ground
riešenia na presné meranie
http://www.elso.sk
Clamp Meter
Fast and easy earth ground loop testing
The Fluke 1630 earth ground clamp meter simplies ground loop testing and enables non-intrusive leakage current measurement. The ground loop testing is also known as “stakeless” earth ground testing. To carry out the measurement there is no need for placing earth stakes and disconnecting the earth system from the electrical installation. The Fluke 1630 combines the two current clamps needed to perform the stakeless ground loop test in one compact and easy to use instrument.
• Ground loop resistance testing without any disconnection or additional earth stakes
• Earth ground leakage current measurement for system troubleshooting
• True RMS AC current measurement range up to 30 A
• Rapid evaluation of continuity without disconnection and audible HI/LO alarm
• Display-HOLD function to freeze measurements
• Recording function for automatic storage of measured values, which can be recalled later on the LCD display
• Automatic self calibration ensures correct measurement every time
The Fluke 1630 is ideally suited for the following applications:
• Ground loop checks on any earthing system
• Continuity tests on earth bonding circuits and connections
• Inspection of lightning protection systems
• Leakage current measurement for troubleshooting on earth ground systems
Fluke 1630
Included Accessories
Rugged carrying case with belt, Resistance test loop, 9 V battery, Operating instructions.
Specifications
(Check the Fluke web for detailed specifications)
Resistance 0.025 to 1500  0.002  Cntinuity buzzer < app. 40  Leakage current 0.2 to 1000 mA 0.001 mA Current 0.2 to 30 A 0.01 A
Range Max. resolution
Weig ht: 0.64 kg Conductor Size: 35 mm approx. Size (HxWxD): 257 mm x 100 mm x 47 mm Battery type: 9 V IEC 6 LR 61 Two Year Warranty
Ground resistance measurements principle
Ground resistance measurements principle
1630
EARTH GROUND CLAMP
mA
HOLD
CAT
OFF
300
A
 V
FUNC REC
.....R
n
R
3
.....R
n
Equivalent circuit diagram
R
g
R
1
1630
EARTH GROUND CLAMP
mA
HOLD
CAT
OFF
300 
A
V
FUNC REC
R
R
2
1
R
2
Ordering Information
Fluke 1630 Earth Ground Clamp Meter
42
g
R
1630
EA RTH GROUND CLAMP
mA
HOLD
CAT
OFF
300
A
V
F UNC REC
R
g
Page 45
Installation Testers/
riešenia na presné meranie
http://www.elso.sk
Portable Appliance Testers
Our multifunction testers have redened the standards for ease-of-use. With new features like the fast, high current loop test, RCD Type B compatibility, extended memory, and the fact they are designed for ensuring xed wiring installed according to IEC 60364,they perform all tests required to verify safety. Our Portable Appliance Testers verify the safety and operation of portable appliances, and are designed for ‘one­touch’ operation and a fast throughput.”
43
Page 46
1650 Series Multifunction
riešenia na presné meranie
http://www.elso.sk
Installation Testers
New
RCD Type B Compatibility
Fluke 1654B
Fluke 1653B
Fluke 1652C
BS7671 17th Edition IEE Wiring Regulations IEC 60364.6.61, HD 384
Included Accessories
6 AA Cell batteries C1600 Hard carrying case Zero Adapter Mains test cord TL165X STD Standard Test Lead Set TL165/UK Fused Test Lead Set (UK only) Padded carrying strap Quick reference guide TP165X Remote control probe and lead Users manual on CD-ROM
Ordering Information
Fluke 1652C Multifunction Installation Tester Fluke 1653B Multifunction Installation Tester Fluke 1654B Multifunction Installation Tester
Extra functionality, faster testing, and as rugged as ever
Safer, easier installation testing. The new 1650 Series builds on the rugged reputation of the earlier 1650 Series, only it’s re-designed to meet your need for more productive test tools. With new features like the fast, high current loop test (including a non-trip test) and a variable RCD trip current setting, accuracy is even better and the test cycle even faster. And with the addition of a unique zero adapter accessory for accurate mains test lead compensation, the 1650 Series continues to set the standard in installation testers. The 1650 Series testers verify the safety of electrical installations in domestic, commercial and industrial applications. They can ensure that xed wiring is safe and correctly installed to meet the requirements of IEC 60364, HD 384 and BS 7671 17th Edition wiring regulations.
1654B - The complete tester for advanced users
This is the instrument that has it all, in a word: it’s complete. From all the test functions you need to in-built memory
Measurement Function
Voltage & Frequency
Insulation Resistance
Continuity & Resistance
Loop & Line Resistance
Loop & Line Resistance–m1 resolution
Prospective Earth Fault Current (PEFC/IK) Prospective Short-Circuit current (PSC/IK)
RCD switching time
RCD tripping level
RCD variable current
Automatic RCD test sequence
Test pulse current sensitive RCDs (Type A)
Test smooth dc sensitive RCDs (Type B)
Earth Resistance
Phase Sequence Indicator
Other Features
Self-test
Illuminated Display
Memory, Interface
Memory
Extended Memory
Computer Interface
Time and date (When used with FlukeView software)
Software
Included Accessories
Hard case
Remote control probe
Zero Adapter
for documenting results. This makes it the complete solution for professionals, especially contractors, everyone who would want to have the best tool available and always understands (or know) how to use.
1653B - The ideal tester for professional trouble-shooters
This is the instrument that is indeed ideal for professional users due to its additional functionality. It is also ideal since even though it has high-end features, it is still easy to use – even after longer periods of non-use; because operating it is intuitive and not forgotten easily.
1652C - The everyday tester, for every electrical installer
This is the instrument that can be used every single day (day in, day out), and covers all the basic needs. It is the preferred tester for every front-line electrician/installer.
1652C 1653B 1654B
OOO
OOO
OOO
OOO
OOO
OOO
OOO
ramp test
O
OOO
OOO
OOO
OOO
OOO
OOO
OOO
OOO
OOO
Recommended Accessories
See also page 48 for more details
Features
O
ramp test
O
OO
OO
OO
OO
OO
ramp test
O
O
O
Check the Fluke website for the various software modules
44
TLK290 MTC1363 (UK) MTC77 (Europe) ES165X 1653B &1654B FVF-SC2
Page 47
1650 Series Multifunction
riešenia na presné meranie
http://www.elso.sk
Installation Testers
Slim probe design
Thanks to its slim probe with integral test button, you can safely make one-handed measurements on hard to reach points, while keeping your eyes on the panel. This remote probe is powered by the tester so always operable (does not require additional batteries!).
Zero Adaptersign
For easy, always reliable and accurate compensation for test leads and mains cords. This adapter can be used for all different kind of mains plugs as well as test accessories like probes, alligator clips etc.
Extra functionality, faster testing, and as rugged as ever
Specifications
(Check the Fluke web for detailed specifications)
AC Voltage Measurement
Range Resolution Accuracy
500 V 0.1 V ± (0.8% + 3 digits) 3.3 M1 660 Vrms
50 Hz - 60 Hz
Continuity Testing
Ratnge
(autoranging)
20 1 00.1 1
200 1 0.1 1
2000 1 1 1
Resolution Test Current Open Circuit Voltage Accuracy
> 200 mA > 4 V ± (1.5%+3 digits)
Insulation Resistance Measurement
Model Test Voltage Insulation
1653B / 1654B 50 V 10 k1 to 50 M1 0.01 M1 1 mA @ 50 k1 ± (3%+ 3 digits) 1653B / 1654B 100 V 20 k1 to 100 M1 0.01 M1
1653B / 1654B 1653B / 1654B
1653B / 1654B
1652C
1653B / 1654B 1653B / 1654B
1652C
Loop Impedance Measurement
Notes [1] Valid for resistance of neutral circuit <20 1 and up to a system phase angle of 30°. Test leads must be zeroed before testing.
[2] Valid for mains voltage >200 V.
PFC. PSC Test
Range 1000A / 10kA(50kA) Resolution and Units 1A / 0.1kA Accuracy Determined by accuracy of loop resistance and mains
Computation Prospective Earth Fault Current (PEFC) or Prospective Short Circuit Current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
RCD Testing
RCD Type
[1]
AC AC S
[4]
A AS
[5]
B BS
Notes [1] AC - Responds to ac [2] G - General, no delay [3] S - Time delay [4] A - Responds to pulsed signal
Tripping Time Test (6T)
10, 30, 100, 300, 500, 1000 mA, VAR x 1/2 + 0% - 10% ± (1% Reading + 1 digit)
G
G
G
Current Settings Multiplier Test Current Accuracy Trip Time Accuracy
10, 30, 100 mA X 5 + 10% - 0% ± (1% Reading + 1 digit)
250 V 20 k1 to 200 M1 0.01 M1
500 V 20 M1
1000 V 20 M1
Range Resolution Accuracy
10 1 0.001 1 Hi Current m1 mode: ± (2 % + 15 digits)
20 1 0.01 1
200 1 0.1 1
2000 1 1 1 ±6 %
[6]
[2]
[3]
[5] B - Responds to smooth dc [6] RCD test inhibited for V >265 ac RCD tests permitted only if the selected current, multiplied by earthing resistance, is <50 V.
Resistance Range
200 M1 500 M1
200 M1
1000 M1
Model 1652C Model 1653B Model 1654B
•••
•••
•••
•••
Resolution Test Current Accuracy
voltage measurements
Tripping Current (Ramp) Test
Current Range Step Size
30 % to 110 % of
RCD rated current
Notes [1] 30 % to 150 % for Type A 6 N >10 mA 30 % to 210 % for Type A 6 N =10 mA 20 % to 210 % for Type B Specified trip current ranges (EN 61008-1):
Earth Resistance Test (RE) – Fluke 1654B and 1653B only
Range Resolution Accuracy 200 1 0.1 1 ± (2% + 5 digits)
2000 1 1 1 ± (3.5% + 10 digits)
10 % of I 6 N
[1]
[2]
Type G Type S
300 ms/step 0 ms/step ±5 %
50 % to 100 % for Type AC 35 % to 140 % for Type A ( >10 mA) 35 % to 200 % for Type A ( )10 mA) 50 % to 200 % for Type B [2] 5% for Type B
Input Impedance Overload Protection
0.1 M1
0.1 M1
0.01 M1
0.1 M1 1 M1
0.1 M1 1 M1
Dwell Time
1 mA @ 100 k1 ± (3%+ 3 digits)
1 mA @ 250 k1 ± (1.5%+ 3 digits)
1 mA @ 500 k1 ± (1.5%+ 3 digits)
1 mA @ 1 M1 ± (1.5%+ 3 digits)
No Trip mode: ± ( 3 % + 6 digits)
Hi Current mode: ± (2 % + 4 digits)
No Trip mode: ± (3 %)
Hi Current mode: ± (2 %)
+ 10%
+ 10%
[1]
[2]
Measurement
Accuracy
Complete kit
All 1650 models are equipped with detachable leads that can be replaced in case of damage or loss. A durable hard case will protect your instrument in tough eld conditions.
Battery type: Alkaline supplied. usable with 1.2 V NiCD or NiMH rechargeable batteries
Size (HxWxD): 100 mm x 250 mm x 125 mm
Weig ht: 1.3 kg Three Year Warranty
45
Page 48
6000 Series PAT Testers
riešenia na presné meranie
http://www.elso.sk
Fluke 6200
Fluke 6500
Also available with European mains socket.
Versatile PAT testing at your fingertips
The Fluke 6200 and 6500 PAT testers verify the electrical safety and operation of portable appliances in accordance with relevant guidelines and regulations. With powerful auto test capabilities and simplied controls they increase the number of tests you can perform per day without compromizing results.
A choice of automatic and manual PAT testers
Both models perform all the tests required for class I and class II appliances. For manual testing and low volume applications, choose the cost­effective 6200 PAT model. If you need a more powerful instrument to test large numbers of appliances, the 6500 is the right choice.
6200 6500
• Dedicated key for each test for ‘one­touch’ testing
• Pre-set pass/fail levels to save time
• Large backlit display for easy reading
Fluke simplifies portable appliance testing
• Compact and lightweight… Efcient to work with and easy to carry around– and has extra space in the hard case for accessories.
• One touch simplicity… Pre-set and user-denable test routines are initiated from a single button – to speed up test procedures and save you time on site.
• A better way of working… Rapid data entry via a QWERTY keyboard (or optional Fluke barcode scanner) and fast data transfer from the main memory or the Compact Flash memory card (6500).
As 6200 but also with:
• Integral QWERTY keyboard for rapid data entry
• Slot for Compact Flash memory card for back-up data storage and transfer to PC
• Pre-set, auto-test sequences for user convenience
Included Accessories
Test lead, Test probe, Crocodile clip, Mains cord
Ordering Information
Fluke 6200 PAT Tester Fluke 6500 PAT Tester
Not available in all countries
Features
Measurement functions 6200 6500
L N Mains Volts Outside Limits Indicators Null out facility for earth bond lead Protective Earth Resistance PE (200mA) Protective Earth Resistance PE (25A) Insulation 500V dc Protective Earth Conductor Current Touch Current Substitute Leakage Current Appliance Power kVA Appliance Load Current Seven Segment Custom LCD Graphical LCD Back Light Compact Flash Card receptacle Serial Port - Printing / Downloading
External printer output Front Panel QWERTY Key pad
IEC Lead Test Auto-testing Pass / Fail Level Programmable Indicators Data Storage Limited Data Storage Polarity Checks Graphical Help Menu On Line Programme Mode Real time clock
Front panel results management 230V BS1363 Test socket / 230V Mains BS1363 input power plug
OO
OO
OO
OO
OO
OO
OO
OO
OO
OO
OO
O
O
OO
O
OO
OO
O
OO
O
O
O
O
OO
O
O
O
O
OO
46
Page 49
6000 Series PAT Testers
riešenia na presné meranie
http://www.elso.sk
The accuracy specification for the display range is defined as ± (%reading + digit counts) at 23 °C ± 5 °C, ≤ 75 % RH. Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C. The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997 , EN61557-4: 1997.
Specifications
Separate hard case
The compact Fluke PAT testers are supplied with a hard carrying case that not only offers protection during transit but also includes extra storage space for accessories and other tools. They’re extremely light, weighing approximately 3 kg (without case) and have integral carrying handles for extra convenience.
Special PAT Kit
If you need a complete PAT tester solution, a purpose made kit is available. Fluke 6500/UK Kit Contains:
• 6500, Mainframe
• EXTL 100, Extension lead test adaptor
• SP Scan 15, Barcode scanner
• Fluke PowerPat Plus
• Pass 560R, Appliance pass labels
• Fail 100S, Appliance fail labels APP 1000, Barcode appliance number labels
(Kit contents may vary per country)
Display Screens
Power-on Test
The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
Display Range 90 V to 264 V Accuracy at 50 Hz ± (2% + 3 counts) Resolution 0.1V (1V - model 6200) Input Impedance > 1 M // 2.2 µF Maximum Input Mains Voltage 300 V
Earth Bond Test
Display Range 0 to 19.99  Accuracy
(after Bond Test zeroing) Resolution 0.01
Test Current 200 mA AC - 0% + 40% into
Open Circuit Voltage > 4 V AC, < 24 Vac Bond Test zeroing can subtract up to 1.99
Insulation Test (Riso)
Display Range 0 to 299 M Accuracy ± (5% + 2 counts) from 0.1
Resolution 0.01 M (0 to 19.99 M)
Test Voltage 500 V DC - 0% + 25% at
Test Current > 1 mA at 500 k load,
Auto discharge time < 0.5 s for 1 µF Max. Capacitive Load Operational up to 1 µF
± (5% +4 counts)
1.99 25 A AC ± 20% into 25 m at 230 V
to 50 M ± (10% + 2 counts) from 50 to 299 M
0.1 M (20 to 199,9 M) 1 M (200 to 299 M)
500 k load
< 15 mA at 0 
Size (HxWxD): 200 mm x 275 mm x 100 mm Weig ht: 3 kg Two Years Warranty
Touch Current Test
Display Range 0 to 1.99 mA ac Accuracy ± (4% + 2 counts) Resolution 0.01 mA Internal Resistance (via probe) 2 k Measuring method Probe The appliance under test is energized at mains potential.
Substitute Leakage Current Test
Display Range 0 to 19.99 mA ac Accuracy ± (5% + 5 counts) Resolution 0.01 mA Test Voltage 35 V AC ± 20% Operational Error 10%
Load/Leakage Test: Load Current
Display Range 0 to 13 A Accuracy ± (4% + 2 counts) Resolution 0.1 A The appliance under test is energized at mains potential
Load/Leakage Test: Load Power
Display Range 0 to 999 VA
Accuracy ± (5% + 3 counts) Resolution 1 VA (0 to 999 VA)
The appliance under test is energized at mains potential
Load/Leakage Test: Leakage Current
Display Range 0.25 to 19.99 mA Accuracy ± (4% + 4 counts) Resolution 0.01 mA The appliance under test is energized at mains potential
PELV Test
Accuracy at 50 Hz ± (2% + 3 counts) Overload protection 300 Vrms Warning threshold 25 Vrms
1.0 kVA to 3.2 kVA
0.1 kVA (1.0 kVA to 3.2 kVA)
Current Test
Earth Bond Test (RPE)Substitute Leakage
Recommended Accessories
See also page 48 for more details
Fluke PowerPat Plus
Touch Current TestInsulation Test (RISO)
software
SP1000-02
Mini printer
SP-SCAN-15
Barcode scanner (6500 Fluke only)
BDST3 Snap Tags
Cable Tie
PASS
Appliance 560R
Pass Labels
47
Page 50
1650 Series/6000 Series
riešenia na presné meranie
http://www.elso.sk
Accessories
Accessories for Fluke 1650 Series Installation Testers
ES165X Earth Spike Test Kit (Fluke 1653B and 1654B)
Earth Spike Test kit contents:
• Auxiliary earth probes
• Test connection leads and crocodile clips
• Purpose-made carry case
FVF-SC2 Fluke ViewForms Software (Fluke 1653B)
To address the increasing demands for reporting and documentation, Fluke presents FlukeView Forms documenting software. Download the data from the Fluke 1653B and create an easy report. The Fluke ViewForms Software also supports other Fluke tools. See page 132.
Accessories for Fluke 6500 Series Portable Appliance Testers
PASS560R Appliance Pass Labels
Quantity 500
APP1000/APP2000 Bar Code Appliance Number Labels
APP1000: Labels numbered 0001-1000 APP2000: Labels numbers 1001-2000 Label number >2000 on request
SP1000 Mini Printer
Without using any additional software the SP1000 can be used to directly printout stored test records on to thermal paper. The printer is compact and easily transported and is ideal for test professionals who need to issue an immediate written account of work carried out. The printer is powered by a rechargeable battery and comes complete with mains charger and RS232 Printer Lead.
SP1000 Paper
Replacement thermal paper for the SP1000 Mini Printer
Fluke DMS software for 1650/6000 Series
BDST3/BDST4 Snap Tags
BDST3: Cable Tie BDST4: Clip On Quantity 20. Without labels.
TLK 290 Test Probe Kit
• Kit includes three exible socket probes and a large alligator clip
• To be used on three phase sockets
• Probes have exible width test points that t securely in 4 to 8 mm sockets
• CAT III 1000 V, 8 A
Mains Test Cord for 1650B series
MTC1363 UK plug MTC77 Schuko plug
48
The Fluke DMS (Data Management Software) is an efcient program for administration and reporting of installation tests in compliance with EN 60364, DIN VDE 0100/0105, BS7671 17th edition wiring resulation and appliance
EXTL100-02 (Schuko plug)EXTL100-02 (UK plug)
EXTL100 Extension Lead Test Adaptor
Adaptor for testing extension leads. Allows the earth test lead to be connected to the extension leads to perform insulation and earth bond tests.
tests in compliance with DIN VDE 0701/0702, ÖVE E 8701.
DMS 0100/INST Software for Installation Tester Fluke 1653B and 1654B
Supporting reports for Austria, Germany, UK, Switzerland, Netherlands
DMS 0702/PAT Software for Portable Appliance Tester Fluke 6500
Supporting reports for Austria, Germany, UK, Netherlands
DMS COMPL PROF Software for the Fluke 1654B, 1653B and Fluke 6500
Supporting reports for Austria, Germany, UK,
MTC77MTC1363
SPScan15 Barcode Scanner
Easy to use, low current, intelligent barcode reader. SPScan15 can be used to scan barcodes attached to curved surfaces or where actual contact with the barcode surface is difcult.
Switzerland, Netherlands
Page 51
Digital Thermometers
riešenia na presné meranie
http://www.elso.sk
For troubleshooting systems where temperature is a critical symptom, our digital thermometers provide you with laboratory accuracy wherever you need it. We offer a choice of non-contact, laser-guided infrared thermometers for safely getting at hard-to-reach, electrically live or particularly hot targets, and contact thermometers with a full range of thermocouple probes.
49
Page 52
Infrared Thermometer
riešenia na presné meranie
http://www.elso.sk
Selection Guide
O
focus)
60:1 (50:1
with close
OO
focus)
with close
laser
3-point
300 mm
(with close
focus) up to 10.5 m
laser
3-point
(with close
focus) up to 10.5 m
O
/-
/-
OO
O
O
Safety and protection
Fire localization
Hazardous materials
Faulty ballasts
Search and rescue
Smoldering embers
Equipment maintenance
Recommended Applications
Fluke 60 Series Fluke 560 Series Fluke 570 Series
laser
single-point
OO O
laser
single-point
OOOOO
OOOOO
laser
single-point
O
-/
laser
single-poimt
O
-/
laser
single-point
OO
OO
OOO O
20 points 99 points 100 points
OOO O
Type K Thermocouple Type K Thermocouple Type K Thermocouple Type K Thermocouple
OO
Manufacturing processes
Molding temperature measurement
Printing, paper and converting
Thermoforming plastics
Electronics
Paint curing/drying
Food
Chemical and pharmaceutical
Heating/ventilation/air conditioning/
refrigeration
Leaky ductwork
Thermostats
Temperature balancing
Steam distribution systems
Compressor lines
50
Fluke 61 Fluke 62 Fluke 63 Fluke 561 Fluke 566 Fluke 568 Fluke 572 Fluke 574
Infrared Thermometer
Selection Guide
Temperature range -18 to 275 ºC -30 to 500 ºC - 32 to 535 ºC - 40 to 550 ºC - 40 to 650 ºC - 40 to 800 ºC - 30 to 900 ºC - 30 to 900 ºC
Accuracy 2% 1.5% 1% 1% 1% 1% 0.75% 0.75%
Response time < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 500 mSec < 250 mSec < 250 mSec
Optical resolution 8:1 10:1 12:1 12:1 30:1 50:1 60:1 (50:1
laser
Up to 2 m Up to 2 m Up to 2.5 m Up to 2.5 m Up to 4.5 m Up to 7.5 m 300 mm
Laser sighting single-point
Recommended distance
to spot
Close focus model
available
Adjustable emissivity
OOOOOOOO
Plant/facilities maintenance
Preventive and predictive maintenance
Energy audits
Vehicle and fleet maintenance
programs
Faulty electrical/circuit connections
Petrochemical/hazardous locations
Motors, pumps and bearings
MIN/MAX readings
AVG readings
DIF readings
Backlit LCD
Bar graph display
Audible Hi/Lo alarm
Visible Hi/Lo alarm
Includes contact probe
Probe input (types)
Data logging
(number of
measurements)
PC interface USB RS232
Compatible with
FlukeView Forms
software
See catalog page 52 52 52 54 53 53 51 51
Contact thermometers
For our complete range of contact
thermometers, see page 55.
Page 53
570 Series
riešenia na presné meranie
http://www.elso.sk
Precision Infrared Thermometers
Measure temperature with ease and precision
The Fluke 570 series are the most advanced IR non-contact thermometers, and are ideal for predictive and preventative maintenance applications. Offering a broad temperature range and a true dimension laser sighting system for precise targeting resulting in more accurate measurements. When requiring analysis and documentation use the 100-point data logging and software for graphing and analysis. From close-up electrical connections, to far-distance room balancing checks, the Fluke 570 series can take IR temperature measurements with ease and precision.
Fluke 574
• Enhanced optics allows measurements of smaller objects from farther away
• True Dimension™ three-dot laser sighting system highlights the true diameter of measurement spots at all distances
• Adjustable emissivity setting and 30 pre-set common material values for more accurate measurements
• 100 data point memory for storage of measurements (Fluke 574).
Features
Fluke 572
Included Accessories
Fluke 572: Hard case, 2 batteries Fluke 574: Hard case, 2 batteries, Thermocouple
K probe, 220V power supply, IRGraph software, RS232 cable
Ordering Information
Fluke 572 Precision Infrared Thermometer Fluke 574 Precision Infrared Thermometer Fluke 572CF Precision Infrared Thermometer with close focus option Fluke 574CF Precision Infrared Thermometer with close focus option
Temperature range -30 to 900ºC Optical resolution Standard: 60:1
3 dot laser beam for accurate targeting Adjustable emissivity Bar graph display Backlit LCD display Use selectable ºC or ºF Audible and visible Hi/Lo Alarm MIN/MAX AVG/DIF readings Datalogging (number of measurements) 100 PC interface RS232
572 574
Close focus: 50:1
OO
OO
OO
OO
OO
O
/-
OO
O/O
O
Specifications
Temperature range -30 to 900°C Response time 250ms (95 % of reading) Resolution 0.1°C of reading up to 900°C Repeatability ±0.5% of reading or ±1°C* Accuracy: (assumes ambient operating temperature of 23 ºC to 25 ºC ) ±0.75% of reading, ±0.75°C * Typical distance to target 10,5 m Emissivity Digitally adjustable from 0.10 to 1.0
*whichever is greater.
Battery Life: 10 hours typical Weig ht: 0.480 kg Size (HxWxD): 200 mm x 170 mm x 55 mm Two years warranty
572 574
by 0.01
Recommended Accessories
AN5
Analog data cable
51
Page 54
Fluke 63
riešenia na presné meranie
http://www.elso.sk
60 Series
Infrared Thermometers
Point, press and read temperature
The Fluke 60 Series non-contact thermometers are the ideal professional diagnostic tools for quick and accurate temperature measurements. These handheld tools are ideal for measuring surface temperatures of rotating, hard-to-reach, electricity live or dangerously hot targets like electrical motors and – panels, and heating and ventilation systems. The laser sighting system guides measurements to the right target and in less than a second, the large temperature display provides a readout of the surface temperature.
Fluke 62
Form factor Flat grip Pistol grip Pistol grip Temperature range -18 to 275°C -30 to 500 °C -32 to 535°C Optical resolution 8:1 10:1 12:1 Laser beam for accurate targeting Backlit LCD display Use selectable °C or °F Min/max/avg/dif readings Max Max
The 60 Series IR thermometers feature:
• Laser guided sighting system for easy targeting with 1% accuracy
• Up to 12:1 optical resolution
• Backlit display for easy reading in the dark
• Temperatures up to 535°C
61 62 63
OOO
OOO
OOO
Features
Fluke 61
The Fluke FoodPro™ thermometer series provide advanced temperature measurement solutions for the foodservice industry. Check the Fluke web for more information.
Included Accessories
Fluke 61: 9V Battery Fluke 62: 9V Battery, storage holster Fluke 63: Hard carrying case, 9V batteries
Ordering information
Fluke 61 Infrared Thermometer Fluke 62 Mini Infrared Thermometer Fluke 63 Infrared Thermometer Fluke 62/322/1AC-E (see page 5) Fluke T5-600/62/1AC (see page 5) Fluke FP FoodProTM Food Safety Thermometer Fluke FP Plus FoodProTM Plus Food Safety Thermometer
Specifications
Range - 18 to 275ºC - 30 to 500 ºC - 32 to 535 ºC Response time < 500ms < 500ms
Resolution 0.2 ºC 0.2 ºC 0.2 ºC
Repeatability (% of reading)
Accuracy:
(assumes ambient operating temperature of 23ºC)
Typical distance to target Up to 1m Up to 1.5 m Up to 2 m Emissivity Fixed at 0.95 Pre-set to 0.95 Fixed at 0.95
* whichever is greater
Batter y Life:
Fluke 63: 10 hours with laser and backlight on Fluke 62: 12 hours with laser and backlight on Fluke 61: 12 hours with laser and backlight on
Size (HxWxD):
Fluke 63: 200 mm x 160 mm x 55 mm Fluke 62: 152 mm x 101 mm x 38 mm Fluke 61: 184 mm x 45 mm x 38 mm
Kits
61 62 63
≤ 0.5 second
± 0.5%
or ≤ ± 1 ºC*
For targets at:
-32 to -26°C: ± 3°C
-26 to -18°C: ± 2.5°C
-18 to 23°C: ± 2°C 23°C -510°C: ± 1%
of reading or ± 1°C*
For targets
above 510°C:
± 1.5% of reading
± 2%
or ± 2 ºC*
For targets at:
-18 to -1ºC: ± 3ºC
-1 to 275ºC: ± 2% of reading or ± 2ºC
(95 % of reading)
± 0.5%
or < ± 1 ºC*
For targets at:
10 °C to 30 °C: ±1 °C
± 1.5% of reading
or ± 1.5°C whichever
is greater over
the balance of the
range
Weig ht:
Fluke 63: 0.320 kg Fluke 62: 0.200 kg Fluke 61: 0.227 kg
Fluke 62: 2 years warranty Other models: one year warranty
Recommended Accessories
52
Fluke 62/322 kit T5-600/62/1AC-E
C23
See page 130
H6
See page 131
Page 55
Fluke 566
riešenia na presné meranie
http://www.elso.sk
566 and 568
Multipurpose Thermometers
The two-in-one infrared and contact thermo­meter with an innovative graphical display
With a straight-forward, menu-driven user interface and graphical display, the Fluke 566 and 568 multipurpose thermometers make even complex temperature measurements easy. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button. For added convenience, both rugged handheld thermometers combine contact and non-contact temperature measurement capability, providing a total temperature measurement solution for any service and maintenance program.
• Easily access advanced features with the soft-key buttons and graphical display
• Measure smaller targets from farther away using the IR thermometer
• Adjustable emissivity and built-in table of common materials for higher IR accuracy
• Quickly identify problems with the MIN, MAX, AVG, and DIF functions
• 2-color ashing alarm alerts you visually when measurements exceed limits
• Includes Type K thermocouple bead probe
• Compatible with all standard mini­connector K-type thermocouples
• Data logging with a date/time stamp
• Soft rubber boot for increased ruggedness
• User interface available in 6 languages
Fluke 568
The Fluke 566 and included accessories
The Fluke 568 and included accessories
Included accessories
FlukeView® Forms software (568 only), USB cable (568 only), K-type thermocouple bead probe, 2 AA batteries, hard carrying case, quick start guide, and users manual.
Choose your language Select the measurement surface See complete measurement details
in seconds
Specifications
(Check the Fluke web for detailed specifications)
Infrared temperature range -40 °C to 650 °C -40 °C to 800 °C Infrared accuracy < 0 °C : ± (1.0 °C + 0.1°/1 °C);
Display resolution 0.1 °C Infrared spectral response 8 µm to 14 µm Infrared response time < 500 msec Input temperature range -270 °C to 1372 °C Input accuracy -270 °C to -40 °C: ± (1 °C + 0.2 °/1 °C)
D:S (Distance to measurement spot size) 30:1 50:1 Laser sighting Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm Minimum spot size 19 mm Emissivity adjustment By built-in table of common materials or digitally adjustable
Data logging with Date/Time stamp 20 points 99 points PC interface and cable None USB 2.0 with FlukeView
Hi/Low alarms Audible and two-color visual Min/Max/Avg/Dif Yes Display Dot matrix 98 x 96 pixels with function menus Backlight Two levels, normal and extra bright for darker environments Trigger Lock Yes Switchable between Celsius and Fahrenheit Yes
Power: 2 AA/LR6 Batter ies (566); 2 AA/LR6 Batteries and USB for use with a PC (568) Battery life: Used continuously; laser and backlight on: 12 hours; laser and backlight off: 100 hours
566 568
> 0 °C : ± 1 % or ± 1.0 °C, whichever is greater
-40 °C to 1372 °C: ± 1 % or 1 °C, whichever is greater
from 0.10 to 1.00 by 0.01
Forms software
Weig ht: 0.965 kg (566); 1.026 kg (568) Size (HxLxW): 25.4 cm x 19.1 cm x 6.9 cm Operating temperature: 0 °C to 50 °C Storage temperature: -20 °C to 60 °C Two years warranty
®
Recommended Accessories
Ordering information
Fluke 566 Infrared thermometer Fluke 568 Infrared thermometer
H6
See page 131
80PK-8
See page 128
80PK-9
See page 128
80PK-11
See page 128
80PK-25
See page 128
80PK-26
See page 128
53
Page 56
561
riešenia na presné meranie
http://www.elso.sk
Multipurpose Thermometer
Combined Infrared and Contact Thermometer
Fluke 561
The Fluke 561 combines the temperature measurement functions that industrial, electrical, and HVAC/R professionals need, all in one tool. It measures both IR and contact temperature, replacing several other test tools. It’s fast, efcient, and easy to use, saving you valuable time and effort. With the Fluke 561, you can take contact and ambient temperatures in the way that’s best for you. Use the IR thermometer to measure hot, moving, electrically energized, and hard-to­reach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded connections, and wires. Plus, scan ducts, and other hard-to-reach objects from the oor—leave your ladder in the truck. You can use the Fluke 561’s handy Velcro® pipe probe or, plug in any industry standard, K-type mini-connector thermocouple probe you already own.
• IR thermometer for quick measurements up close or at a distance
• Single-point laser sighting
• Easy emissivity adjustment for measuring pipes and ducts more accurately
• Includes a Velcro pipe probe for super­heat and sub-cooling as well as other surface contact measurements
• Also compatible with all standard mini­connector K-type thermocouples
• MIN, MAX and DIF temperature readings
• Lightweight (only 340 grams) and portable
• Includes measurement guide
The Fluke 561 includes everything you need for immediate inspections.
Included accessories
Thermocouple K-type Velcro pipe probe, hand carrying case, 2 AA batteries and user manual with measurement guide.
Ordering information
Fluke 561 HVACPro Thermometer
Specifications
Temperature range -40° to 550°C Display resolution 0.1° of reading D:S (Distance to spot size) 12:1 Easy emissivity selector Adjustable with three settings: low (0.3), medium (0.7), high (0.95) Display accuracy (Assumes ambient operating
temperature of 23° to 25°C) Response time 500 mSec (95% or reading) Repeatability ± 0.5% of reading or ± 1°C, whichever is greater Spectral focus 8 µm to 14 µm Laser sighting Single-point laser Laser shutoff Laser turns off above ambient temperature of 40°C Laser power Class 2 (II) operation; output ‹ 1 mW, wavelength 630 nm to 670 nm Relative humidity 10% to 90% RH non-condensing, at < 30°C Power 2 AA batteries (alkaline or NiCD) Display hold 7 seconds Backlit display Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery,
Operating temperature 0° to 50°C Storage temperature -20 to 65°C MAX, MIN, DIF temperatures Yes Thermocouple type K mini-adapter input Yes, compatible with industry standard type K probes with mini-connector Thermocouple type K Velcro pipe probe Yes, with a temperature range of 0° to 100°C and accuracy of ± 2.2°C Measurement guide Yes
Battery Life (alkaline): 12 hours Size (HxLxW): 176,9 mm x 163,6 mm x 51,8 mm
± 1.0% of reading or ± 1°C, whichever is greater; below 0°C, ± 1°C, ± 1°/1°
F/C indicator, and Scan/Hold options
Weig ht: 340 grams Two years warranty
Recommended Accessories
54
H6
Se page 131
80-PK-1
See page 128
80PK-8
See page 128
80PK-25
See page 128
Page 57
50 Series II Thermometers
riešenia na presné meranie
http://www.elso.sk
Laboratory accuracy. Wherever you go.
The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged handheld test tool.
• Large backlit dual display shows any combination of T1, T2 (52 and 54 only),
(52 and 54 only) plus MIN, MAX,
T
1-T2
or AVG
• Relative time clock on MIN, MAX, and AVG provides a time reference for major events
• Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
• Readout in °C, °F, or Kelvin (K)
• Sleep mode increases battery life
• Battery door allows easy battery replacement without breaking the calibration seal
Additional features for the 53 and 54 Series II:
• Data Logging up to 500 points of data with user adjustable recording interval
• Real time clock captures the exact time of day when events occur
• Recall function allows logged data to be easily reviewed on the meter display
• IR communication port allows data to be exported to optional FlukeView PC software
®
Features
Fluke 54 II B
Fluke 51 II
Fluke 52 II Fluke 53 II B
Included Accessories
Impact absorbing holster Two bead probe thermocouples 80PK-1 (54+52) One bead probe thermocouple 80PK-1 (51+53)
Ordering Information
Fluke 51 II Thermometer Fluke 52 II Thermometer Fluke 53 II B Thermometer Fluke 54 II B Thermometer FVF-SC2 FlukeView Forms Software including USB interface cable
Thermocouple types J,K,T,E J,K,T,E J,K,T,E,N,R,S J,K,T,E,N,R,S Number of inputs Single Dual Single Dual Time stamp Relative Time Relative Time Time of Day Time of Day Splash/Dust resistant Dual display with backlight Min/Max/Avg recording (T1-T2) True differential Data logging up to 500 points IR data port for interface
to PC Compatible with optional
FlukeView Software
51 II 52 II 53 II B 54 II B
OOOO
OOOO
OOOO
OO
OO
OO
OO
Specifications
Temperature range:
J-type Thermocouples -210°C to 1200°C K-type Thermocouples -200°C to 1372°C T-type Thermocouples -250°C to 400°C E-type Thermocouples -150°C to 1000°C N-type** Thermocouples -200°C to 1300°C R** and S-type** Thermocouples 0°C to 1767°C
Temperature accuracy Above –100°C (-148°F):
J, K, T, E, and N-type** ± [ 0.05% + 0.3°C ] R** and S-type** ± [ 0.05% + 0.4°C ]
Below –100°C (-148°F):
J, K, E, and N-types ± [ 0.20% + 0.3°C ] T-type ± [ 0.50% + 0.3°C ]
**Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type
Battery life: 1000 hours typical, AA Size (HxWxD): 173 x 86 x 38 mm
Weig ht: 0.4 kg Three Year Warranty
Recommended Accessories
C25
See page 130
80PK-26
See page 128
80PK-25
See page 128
FVF-SC 2
See page 132
TPAK
See page 132
55
Page 58
Fluke 1524
riešenia na presné meranie
http://www.elso.sk
1523 and 1524
Reference Thermometers
A new standard in accuracy and versatility.
Fluke 1523
Measure, graph and record three sensor types with one tool. The Fluke 1523/24 Reference Thermometer deliver high accuracy, wide measurement range, logging, and trending, all in a handheld tool you can take anywhere. For top accuracy, a memory chip inside the probe connector feeds probe calibration information to the readout. In addition, any thermocouple with a mini-thermocouple connector can be read using the optional universal thermocouple adapter. Choose the 1523 for single channel or the 1524 for dual channel measurement.
Three sensor types
• PRTs: –200 °C to 1000 °C
• Thermocouples –200 °C to 2315 °C
• Precision thermistors: –50 °C to 150 °C
High accuracy
• PRTs: ±0.011 °C
• Thermocouples: ±0.24 °C for J,K,L,M
• Precision thermistors: ±0.002 °C
Fast measurement
• PRTs: up to 0.45 seconds/sample
• Thermocouples: up to 0.3 seconds/ sample
• Precision thermistors: up to 0.3 seconds/sample
Two models
• 1523: Single channel standard model; memory for 25 readings & statistics
• 1524: Two channels; memory for 25 readings and statistics plus logging 15,000 measurements; real-time clock for time and date stamps
Note: The 1523/24 are pictured with probes connected which may be purchased seperately.
Included Accessories
NIST traceable certicate of calibration, users guide, CD-ROM (contains technical manual), 12 V dc universal power supply, RS-232 cable, 9940 I/O ToolKit software
Ordering Information
Fluke 1523* Reference Thermometer Fluke 1524* Reference Thermometer Fluke 1523-P1 Reference Thermometer,
PRT(–200 °C to 420 °C, 6.35 mm x 298 mm), Universal Thermocouple Adapter, TPAK, and Case
Fluke 1524-P1 Reference Thermometer,
PRT(–200 °C to 420 °C, 6.35 mm x 298 mm), Universal Thermocouple Adapter, TPAK, and Case
* Requires an optional probe
Optional Accessories
2384-P INFO-CON Connector, PRT (Gray Cap), Spare 2384-T INFO-CON Connector, Thermocouple (Blue Cap), Spare 2373-LPRT RTD Adapter, Lemo to Mini Grabbers (4-wire)
Features
Sensor Types PRT & RTD, Thermistor, and Thermocouple Thermocouple Types B,C,E,J,K,L,M,N,R,S,T,U Number of inputs Single Dual Data trending (graphing) Graphical display with backlight Min/Max/Avg/Standard deviation recording High speed measurement RS-232 PC communications T1-T2 True differential Data logging up to 15,000 points Time and date stamp
1523 1524
OO
OO
OO
OO
OO
O
O
O
Specifications
(Check the Fluke web for detailed specifications)
Temperature range
Thermocouple –200 °C to 2315 °C PRT & RTD –200 °C to 1000 °C Thermistor –50 °C to 150 °C
Resolution and best accuracy
Thermocouple 0.01 °, ±0.24 °C PRT & RTD 0.001 °, ±0.011 °C Thermistor 0.001 °, ±0.002 °C Operating temperature –10 °C to 60 °C Storage temperature –20 °C to 70 °C
Battery life (alkaline): 20 hours Power supply: Universal 12 Vdc Size (HxWxD): 200 x 96 x 47 mm Weig ht: 0.65 kg Warranty: 1 year
Optional probes:
5616-12-P PRT, 6.35 mm x 298 mm, –200 °C to 420 °C 5615-9-P PRT, 4.76 mm x 229 mm, –200 °C to 420 °C 5610-9-P Thermistor, 3.2 mm x 229 mm, 0 °C to 100 °C
56
TPAK
FLK80P1
(80PK1 with universal
thermocouple adapter)
Recommended Accessories
FLK80P3
(80PK-3A with universal
thermocouple adapter)
2384P and 2384T
Spare INFO-CON Adapters
2373-LTC
Universal TC adapter
Page 59
1551A Ex / 1552A Ex Intrinsically
riešenia na presné meranie
http://www.elso.sk
Safe “Stik” Thermometers
New
1552A Ex
1551A Ex
Included Accessories
NVLAP –accredited report of calibration, user’s guide on CD-ROM, 3 AAA batteries
Ordering Information
1551A-9 “Stik” Thermometer 1551A-12 “Stik” Thermometer 1551A-20 “Stik” Thermometer 1551A-9-DL “Stik” Thermometer with
datalogging
1551A-12-DL “Stik” Thermometer with
datalogging
1551A-20-DL “Stik” Thermometer with
datalogging 1552A-12 “Stik” Thermometer 1552A-12-DL “Stik” Thermometer with
datalogging
Note: Model number appended with a -9, -12, -20 indicates probe sheath length in inches. All probe diameters are 6.35 mm with the exception of the 1551A-9, which is 4.8 mm diameter
The new “gold standard” of industrial temperature calibration
Finally, a digital substitute for your mercury-in-glass thermometers! Highly accurate and durable, the Fluke 1551A Ex/1552A Ex “Stik” Thermometer is soon to become the new “gold standard” of industrial temperature calibration. Whether working outdoors in environments where potentially explosive gases may be present or on the oor of a processing plant, the intrinsically safe, battery-operated, portable reference thermometer is designed to go where you work.
The RTD sensor of the “Stik” Thermometer is housed in a rugged stainless steel sheath—you no longer have to worry about breaking a mercury-in-glass thermometer and the subsequent cleanup. The probe and digital readout are xed together, calibrated as a system, and accurate to ± 0.05 °C over the full
Specifications
Temperature range Accuracy (1 year) Display units Sensor type Probe temperature coefficient Sensor length Sensor position (from sheath tip) Minimum immersion depth Probe sheath material Response time 4.8 mm diameter probe (3/16 in): 14 seconds
Probe hysteresis Temperature resolution Sample rate Operating temperature range of readout Storage temperature Optional data logging Logging intervals Averaging Moving average of most recent 2 to 10 readings, user selectable
Communications EMC compliance Enclosure rating Calibration Characterization
1
Per ASTM E 644
2
See ordering information for optional data logging configurations
Battery Life: 300 hours typical without LCD, 3 AAA Size (HxWxD): 114 x 57 x 25 mm Weig ht: 196 grams Warr anty: 1 year
1
2
2
temperature range. The large backlit LCD display rotates 90° making it easy to read from any position. Minimize measurement errors with the user­congurable temperature trend/stability indicator which tells you when your temperature source is stable or if your temperature is trending up or down.
• ± 0.05 °C accuracy over full range
• Intrinsically safe (ATEX compliant)
• Display temperature in °C or °F
• Optional data logging to internal memory
• Temperature trend indicator
• User selectable resolution (0.1, 0.01,
0.001)
• 300 hour battery life
• Percent battery-life and low battery indicator
• NVLAP accredited calibration (NIST traceable)
1551A Ex 1552A Ex
–50 °C to 160 °C –80 °C to 300 °C
100  thin film RTD 100  wire-wound PRT
≤ 10 mm ≤ 30 mm
70 mm 120 mm
6.35 mm diameter probe (1/4 in): 21 seconds
Selectable: 0.1, 0.01, 0.001 (default 0.01)
Selectable: 0.5, 1, 2, seconds (default 1)
–20 °C to 60 °C , 0 to 95% RH, non-condensing
Up to 10k time-stamped readings stored to internal memory
2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes
RS-232 stereo jack (access calibration parameters only)
EN61326:2006 Annex C; CISPR II, Edition 5.0-2009; Class “B”
NVLAP accredited, NIST Traceable System Calibration
CVD ITS-90
±0.05 °C
°C, °F
0.00385 //°C nominal
3 mm
SST
±0.01 °C
–10 to 50 °C
(ON/OFF, 2,5,10)
IP50
Recommended Accessories
1551-CASE
Carrying case
1551-CBL
RS-232 cable
57
Page 60
Thermal Imagers
riešenia na presné meranie
http://www.elso.sk
Temperature changes can indicate problems in many everyday applications and a thermal imager makes it quick and easy to visually check surface temperatures. Often problems can be discovered before contact measurements even need to be made. Fluke offers a complete range of handheld thermal imagers for both industrial and building diagnostic applications. Models are available for any budget.
5858
Page 61
Ti Series Thermal Imagers
riešenia na presné meranie
http://www.elso.sk
Find it, fix it, fast!
Temperature changes can indicate problems in many areas you see everyday, some include:
Inside electrical distribution and service (Switch gear, panels, controls, fuses,transformers, receptacles, lighting, conductors, bus bars, motor control centers)
• Motors, pumps and mechanical (Electric motors and generators, pumps, compressors, evaporators, bearings, couplings, gearboxes, gaskets/seals, belts, rollers, disconnects)
• Process (Tanks and vessels, pipes, valves and traps, reactors, process insulation)
HVAC/R (air conditioning, heating, air handlers, refrigeration)
Outside electrical distribution - utilities (Transformers, bushings, insulators, transmission lines, other exterior conductors, service connections, disconnects, capacitor banks)
IR-Fusion® Technology: Infrared and visual images fused together in one image
See things both ways - Infrared and visual (visible light) images fused together communicating critical information faster and easier – traditional infrared images are no longer enough. Patented IR-Fusion® Technology, only available from Fluke, simultaneously captures a digital photo and the infrared image and fuses them together taking the mystery out of IR image analysis.
Picture-in-Picture Alpha BlendingFull IR
Overheating bearing cap
Overheated motor
Three-phase switch-gear load imbalance
Cool corner in a building
IR/Visible Alarm
Full Visible Light
SmartView® Software
Fluke SmartView® software is included with each Fluke Thermal Imager. This powerful software is a modular suite of tools that annotates, views, edits and analyzes IR images. It also generates fully customizable and professional­looking reports in a few easy steps. The IR-Fusion technology is fully supported.
FREE webinars/webcasts on Thermal Imaging
Keep up-to-date on the latest troubleshooting techniques. Attend a FREE Fluke webinar (web-based seminar) about thermal imaging applications. Go to the Fluke website for more information.
59
Page 62
New
riešenia na presné meranie
http://www.elso.sk
Ti32/Ti29/Ti27 Industrial/
Commercial Thermal Imagers
The New P3 Series from Fluke
Designed for industrial and commercial environments, the Fluke P3 Series of thermal imagers deliver superior image quality, versatility, and affordability without compromise. They also boast superior infrared resolution, industry leading spatial resolution, and a high denition display creating the sharpest images in their price classes. Finding a potential problem before it becomes a costly disaster shows you just how much a Fluke thermal imager can save you in time, money and even lifes.
Superior image quality
Fluke Ti32
• Delivers the clear, crisp images needed to nd problems fast with up to 320 x 240 sensor.
• Identify even the smallest temperature differences that could indicate problems with industry-leading thermal sensitivity (NETD), down to 45 mK.
• Automatic alignment (parallax correction) of visual and infrared images with Fluke patented IR-Fusion®.
• Optional telephoto and wide angle lenses available for added versatility and special applications (easily installable in the eld).
New
Fluke Ti29
Easy to use
• Field replaceable batteries give you maximum exibility no matter where your work takes you.
• Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.
• No need to carry pen and paper—record ndings by speaking into the imager. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference.
• One-handed focus capability, emissivity correction, reected background temperature compensation, and transmission correction increase the accuracy of measurements in most situations.
• Adjustable hand strap for left-or right-handed use.
• Everything needed to get started is included.
Rugged
• Optimized for eld use in challenging work environments.
• Engineered and tested to withstand a 2 m drop for the ultimate peace of mind.
• Withstands dust and water—tested to an IP54 rating.
• With their rugged design, integrated lens cover, protected display and 2 meter drop test, they are designed to handle the harshest environments.
60
Fluke Ti27
Page 63
Ti32/Ti29/Ti27 Industrial/
riešenia na presné meranie
http://www.elso.sk
Commercial Thermal Imagers
Specifications
Thermal imaging performance
Detector type 240 x 180 Focal Plane Array,
Field of view (FOV) 23 º horizontal x 17 º vertical Spatial resolution (IFOV) 1.67 mRad 1.49 mRad 1.25 mRad Min focus distance 15 cm Thermal sensitivity (NETD) ≤0.05 °C at 30 °C (50 mK) ≤0.045 °C at 30 °C (45 mK) Minimum span (auto/manual) 2.5 °C / 5 °C Focus Manual
Optional telephot infrared lens type
Field of view (FOV) 11.5” x 8.7” Minimum focus distance 45 cm
Optional wide-angle infrared lens type
Field of view (FOV) 46” x 34” Minimum focus distance 7.5 cm
Visual imaging performance
Minimum focus distance 46 cm On camera operating modes Picture-in-Picture and full screen IR plus Blending Color Alarm High temperature alarm Visible light camera 2.0 MegaPixel
Temperature measurement
Temperature range -20 °C to 600 °C Accuracy Measurement modes
Image presentation
Digital display 9.1 cm (3.7”) landscape color VGA (640x480) LCD LCD backlight Selectable bright or auto Palettes
Ultra Contrast Palettes
Voice Annotation
Voice annotation
Image and data storage
Storage medium 2GB SD Card (3000 .bmp IR images/1200 .IS2 images)
File formats supported JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Controls and adjustments
Set-up controls Date/time, Cº/ºF, language
Language selection Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur
Image controls Smooth auto scaling and manual scaling
Power
Battery type Two replaceable rechargeable battery packs (Lithium ion) Battery operating time 4+ hours per battery pack
Fluke Ti27 Fluke Ti29 Fluke Ti32
uncooled microbolometer
Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale,
On-screen reflected background temperature compensation
280 x 210 Focal Plane Array,
uncooled microbolometer
±2 °C or 2%
Center point and hot and cold markers
Grayscale Inverted
O
O
On screen emissivity correction
On-screen transmission correction
320 x 240 Focal Plane Array,
uncooled microbolometer
Water and dust resistant: IP54 Size (HxWxD): 277 x 122 x 170 mm Weig ht: 1.05 kg Two Years Warranty
Complete package
Included Accessories
SmartView® software 2 GB SD card SD card reader Rugged hard carrying case Soft carrying case Hand strap Rechargeable battery (extra) AC charger/power supply User manual
Ordering Information
Fluke Ti27 Thermal Imager Fluke Ti29 Thermal Imager Fluke Ti32 Thermal Imager
FLK-LENS/TELE1
Telephoto Infrared Lens
FLK/LENS/WIDE
Wide-angle Infrared Lens
Recommended Accessories
Ti-Car Charger
Car charger
FLK-TI-SPB3
Extra battery
FLK-TI-SBC3
Charging base
61
Page 64
New
riešenia na presné meranie
http://www.elso.sk
TiR32/TiR29/TiR27 Building
Diagnostic Thermal Imagers
The New P3 Series from Fluke
Designed specically for the building inspection professional, the Fluke P3 Series of thermal imagers deliver the perfect balance between performance and price. They also boast superior infrared resolution, spatial resolution, and high denition displays. The P3 Series delivers crisp images and impressive reports with the included professional SmartView® software. Whether you’re searching for energy waste, leaky roofs or moisture problems, Fluke P3 thermal imagers offer tested and proven technology that takes the guesswork out of nding problems and provides solutions.
Fluke TiR32
Superior image quality
• Delivers the clear, crisp images needed to nd problems fast
• Identify even the smallest temperature differences that could indicate problems with industry-leading thermal sensitivity (NETD), down to 40 mK.
• Automatic alignment (parallax correction) of visual and infrared images with Fluke patented IR-Fusion®
• Optional telephoto and wide angle lenses available for added versatility and special applications (easily installable in the eld).
New
Fluke TiR29
Fluke TiR27
Easy to use
• Field replaceable batteries give you maximum exibility no matter where your work takes you.
• Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.
• No need to carry pen and paper—record ndings by speaking into the imager. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference.
• One-handed focus capability, emissivity correction, reected background temperature compensation, and transmission correction increase the accuracy of measurements in most situations.
• Adjustable hand strap for left-or right-handed use.
• Everything needed to get started is included.
Rugged
• Optimized for eld use in challenging work environments.
• Engineered and tested to withstand a 2 m drop for the ultimate peace of mind.
• Withstands dust and water—tested to an IP54 rating.
• With their rugged body, integrated lens cover, protected display and 2 meter drop test, they are designed to handle the harshest environments.
62
Page 65
TiR32/TiR29/TiR27 Building
riešenia na presné meranie
http://www.elso.sk
Diagnostic Thermal Imagers
Specifications
Thermal imaging performance
Detector type 240 x 180 Focal Plane Array,
Field of view (FOV) 23 º horizontal x 17 º vertical Spatial resolution (IFOV) 1.67 mRad 1.49 mRad 1.25 mRad Min focus distance 15 cm Thermal sensitivity (NETD) ≤0.045 °C at 30 °C (50 mK) ≤0.040 °C at 30 °C (40 mK) Minimum span (auto/manual) 2.5 °C / 5 °C Focus Manual
Optional telephot infrared lens type
Field of view (FOV) 11.5” x 8.7” Minimum focus distance 45 cm
Optional wide-angle infrared lens type
Field of view (FOV) 46” x 34” Minimum focus distance 7.5 cm
Visual imaging performance
Minimum focus distance 46 cm On camera operating modes Picture-in-Picture and full screen IR plus Blending Color Alarm Dewpoint alarm Visible light camera 2.0 MegaPixel
Temperature measurement
Temperature range -20 °C to 150 °C Accuracy Measurement modes
Image presentation
Digital display 9.1 cm (3.7”) landscape color VGA (640x480) LCD LCD backlight Selectable bright or auto Palettes
Ultra Contrast Palettes
Voice Annotation
Voice annotation
Image and data storage
Storage medium 2GB SD Card (3000 .bmp IR images/1200 .IS2 images) File formats supported JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Controls and adjustments
Set-up controls Date/time, Cº/ºF, language
Language selection Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur Image controls Smooth auto scaling and manual scaling
Power
Battery type Two replaceable rechargeable battery packs (Lithium ion) Battery operating time 4+ hours per battery pack
Fluke TiR27 Fluke TiR29 Fluke TiR32
uncooled microbolometer
Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale,
On-screen reflected background temperature compensation
280 x 210 Focal Plane Array,
uncooled microbolometer
±2 °C or 2%
Center point and hot and cold markers
Grayscale Inverted
O
O
On screen emissivity correction
On-screen transmission correction
320 x 240 Focal Plane Array,
uncooled microbolometer
Complete package
Included Accessories
SmartView® software 2 GB SD card SD card reader Rugged hard carrying case Soft carrying case Hand strap Rechargeable battery (extra) AC charger/power supply User manual
Ordering Information
Fluke TiR27 Thermal Imager for Building Diagnostics Fluke TiR29 Thermal Imager for Building Diagnostics Fluke TiR32 Thermal Imager for Building Diagnostics
Water and dust resistant: IP54 Size (HxWxD): 277 x 122 x 170 mm Weig ht: 1.05 kg Two Years Warranty
FLK-LENS/TELE1
Telephoto Infrared Lens
FLK/LENS/WIDE
Wide-angle Infrared Lens
Recommended Accessories
Ti-Car Charger
Car charger
FLK-TI-SPB3
Extra battery
Charging base
FLK-TI-SBC3
63
Page 66
Ti125/Ti110/Ti100 Industrial /
riešenia na presné meranie
http://www.elso.sk
Commercial Thermal Imagers
New
Industrial and commercial maintenance made easy
Technology isn’t working for you if it’s slowing you down. Fluke proudly introduces ve new thermal imagers specically designed to help you do more in less time, while being at home in the harshest of environments. A project that might normally take an hour can now be done in minutes. Our newest imagers are the lightest, most rugged, easiest-to-use professional imagers you can buy.
IR-OptiFlex™ focus system
Discover issues signicantly faster with Fluke’s revolutionary, ultra-rugged focus system. The IR-OptiFlex focus system gives you optimum focus by combining focus-free ease-of-use with the exibility of manual focus on the same camera!
Ti125
IR-Fusion® technology
Enjoy the industry’s best point-and-shoot IR-Fusion camera. Fluke patented technology blends digital and infrared images into a single image to precisely document problem areas.
Ti110
Ti100
Rugged one-hand operation
Experience the most rugged and reliable, lightweight professional camera around. One-touch focus, laser pointer, and torch. Point-and-shoot simplicity. No one builds more rugged, ergonomic tools than Fluke.
Multi-mode video recording
Troubleshoot with the industry’s only thermal imager that records focus-free video in visible light and infrared with full IR-Fusion capabilities. Monitor processes over time, easily create infrared video reports, and troubleshoot.
IR-PhotoNotes™ annotation system
Get an exact reference to your problem area by capturing up to three digital photos per le. Add images of equipment, motor nameplates, workroom doors or any other useful or critical information.
Electronic compass
Make sure you and others know the location of the problem. Compass readings easily appear in images and reports.
64
Page 67
Ti125/Ti110/Ti100 Industrial /
riešenia na presné meranie
http://www.elso.sk
Commercial Thermal Imagers
Included Accessories
SmartView® software AC power adapter Lithium ion smart battery USB cable 2 GB SD memory card Hard carrying case Soft transport bag Adjustable hand strap User manual Two-bag charging base and multi-format USB memory card reader (Ti125 only)
Specifications
Fluke Ti125 Fluke Ti110 Fluke Ti100
Thermal imaging performance
IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer Field of view (FOV) 22.5 °H x 31 °V Spatial resolution (IFOV) 3.39 mRad Thermal sensitivity (NETD) ≤ 0.10 °C at 30 °C target temp (100 mK)
Minimum span in auto mode 5 °C Minimum span in manual mode 2.5 °C Minimum IR focus distance 15.25 cm (6 in) 1.2 m (4 ft) Focus mechanism IR-OptiFlex™ focus system Focus-free 1.2 m and
®
IR-Fusion
technology PIP, FULL IR, FULL VISIBLE,
Color alarms High temperature,
Visual imaging performance
Visible camera 2 megapixel industrial-grade n/a LCD display 3.5 inch diagonal (portrait format) Hot/Cold markers Yes ­User definable spot markers Three on camera and in SmartView Centerbox (MIN/AVG/MAX) Yes ­Level and span control Manual and auto IR-PhotoNotes™ annotation system Yes (3 images) ­Laser pointer Yes Torch Ye s ­Electronic (cardinal) compass Yes ­Emissivity correction Ye s Transmission correction Yes -
Video
Multi-mode video output Streaming USB video output ­Multi-mode video recording
(standard AVI with MPEG encoding) Multi-mode video recording
(radiometric .IS3)
Temperature measurement
Temperature measurement range (not calibrated below -10° C)
Accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Image presentation
Standard palettes Blue-Red, Grayscale, Inverted Grayscale, High-contrast,
Ultra Contrast™ palettes Blue-Red, Grayscale,
Voice Annotation
Voice annotation
Image and data storage
Memory storage 2 GB SD memory card
Power
Battery (field-replaceable, rechargeable)
Battery life 4+ hours (each) (assumes 50% brightness of LCD)
low temperature, isotherm
Yes, radiometric .is3 for approx.. 2.5 to 5 minutes depending upon thermal
High-contrast, Hot Metal,
Water and dust resistant: IP54 Size (HxWxD): 284 x 86 x 135 mm Weig ht: 0.726 kg Two Years Warranty
Industrial-Commercial General
AutoBlend
Yes (AVI with MPEG encoding) -
scene
Hot Metal, Ironbow, Amber, Inverted Amber
Inverted Grayscale,
Ironbow, Amber, Inverted Amber
Yes (60 seconds) per image -
Two One
PIP, FULL IR, FULL VISIBLE No, full IR only
High temperature -
®
-20 °C to +350 °C -20 °C to +250 °C
Blue-Red, Grayscale,
Ironbow
in SmartView® only
-
Blue-Red, Ironbow,
Grayscale, Amber
beyond
-
Ordering Information
Fluke Ti125 Industrial-Commercial Thermal Imager Fluke Ti110 Industrial-Commercial Thermal Imager Fluke Ti100 General Use Thermal Imager
Recommended Accessories
Ti-Car Charger
Car charger
FLK-TI-SPB3
Extra battery
FLK-TI-SBC3
Charging base
65
Page 68
TiR125/TiR110/Ti100 Building
riešenia na presné meranie
http://www.elso.sk
Diagnostic Thermal Imagers
New
Building diagnostics made easy
Technology isn’t working for you if it’s slowing you down. Fluke proudly introduces ve new thermal imagers specically designed to help you do more in less time, while being at home in the harshest of environments. A project that might normally take an hour can now be done in minutes. Our newest imagers are the lightest, most rugged, easiest-to-use professional imagers you can buy.
IR-OptiFlex™ focus system
Discover issues signicantly faster with Fluke’s revolutionary, ultra-rugged focus system. The IR-OptiFlex focus system gives you optimum focus by combining focus-free ease-of-use with the exibility of manual focus on the same camera!
TiR125
IR-Fusion® technology
Enjoy the industry’s best point-and-shoot IR-Fusion camera. Fluke patented technology blends digital and infrared images into a single image to precisely document problem areas.
Rugged one-hand operation
Experience the most rugged and reliable, lightweight professional camera around. One-touch focus, laser pointer, and torch. Point-and-shoot simplicity. No one builds more rugged, ergonomic tools than Fluke.
66
TiR110
Ti100
Multi-mode video recording
Troubleshoot with the industry’s only thermal imager that records focus-free video in visible light and infrared with full IR-Fusion capabilities. Monitor processes over time, easily create infrared video reports, and troubleshoot.
IR-PhotoNotes™ annotation system
Always have references handy – IR-PhotoNotes™ annotation system – quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas (TiR110 and TiR125).
Electronic compass
Make sure you and others know the location of the problem. Compass readings easily appear in images and reports.
Page 69
TiR125/TiR110/Ti100 Building
riešenia na presné meranie
http://www.elso.sk
Diagnostic Thermal Imagers
Included Accessories
SmartView® software AC power adapter Lithium ion smart battery USB cable 2 GB SD memory card Hard carrying case Soft transport bag Adjustable hand strap User manual Two-bag charging base and multi-format USB memory card reader (Ti125 only)
Specifications
Fluke TiR125 Fluke TiR110 Fluke Ti100
Thermal imaging performance
IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer Field of view (FOV) 22.5 °H x 31 °V Spatial resolution (IFOV) 3.39 mRad Thermal sensitivity (NETD) ≤ 0.08 °C at 30 °C target temp (80 mK) ≤ 0.10 °C at 30 °C target
Minimum span in auto mode 2.5 °C 5 °C Minimum span in manual mode 2.0 °C 2.5 °C Minimum IR focus distance 15.25 cm (6 in) 1.2 m (4 ft) Focus mechanism IR-OptiFlex™ focus system Focus-free 1.2 m and
®
IR-Fusion
technology PIP, FULL IR, FULL VISIBLE,
Color alarms High temperature,
Visual imaging performance
Visible c amera 2 megapixel industrial-grade n/a LCD display 3.5 inch diagonal (portrait format) Hot/Cold m arkers Yes ­User defi nable spot markers Three on camera and in SmartView Centerbox (MIN/AVG/MAX) Yes ­Level and span control Manual and auto IR-PhotoNote s™ an notation system Yes (3 images) ­Laser pointer Yes Torch Ye s ­Electronic (cardi nal) compass Yes ­Emissivity correction Ye s Transmission correction Yes -
Video
Multi-mode video output Streaming USB video output ­Multi-mode video recording
(standard AVI with MPEG encoding) Multi-mode video recording
(radiometric .IS3)
Temperature measurement
Temperature measurement range (not calibrated below -10° C)
Accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Image presentation
Standard palettes Blue-Red, Grayscale, Inverted Grayscale, High-contrast,
Ultra Contrast™ palettes Blue-Red, Grayscale,
Voice Annotation
Voice annotation
Image and data storage
Memory storage 2 GB SD memory card
Power
Battery (field-replaceable, rechargeable)
Battery life 4+ hours (each) (assumes 50% brightness of LCD)
low temperature (dewpoint),
Yes, radiometric .is3 for approx.. 2.5 to 5 minutes depending upon thermal
Inverted Grayscale,
High-contrast, Hot Metal,
Water and dust resistant: IP54 Size (HxWxD): 284 x 86 x 135 mm Weig ht: 0.726 kg Two Years Warranty
Building diagnostics General
AutoBlend
and isotherm
Yes (AVI with MPEG encoding) -
scene
Hot Metal, Ironbow, Amber, Inverted Amber
Ironbow, Amber, Inverted Amber
Yes (60 seconds) per image -
Two One
PIP, FULL IR, FULL VISIBLE No, full IR only
Low temperature
(dewpoint)
®
-20 °C to +150 °C -20 °C to +250 °C
Blue-Red, Grayscale,
Ironbow
temp (100 mK)
in SmartView® only
-
Blue-Red, Ironbow,
Grayscale, Amber
beyond
-
-
Ordering Information
Fluke TiR125 Building Diagnostics Thermal Imager Fluke TiR110 Building Diagnostics Thermal Imager Fluke Ti100 General Use Thermal Imager
Recommended Accessories
Ti-Car Charger
Car charger
FLK-TI-SPB3
Extra battery
FLK-TI-SBC3
Charging base
67
Page 70
Ti9/Ti10/Ti25 Thermal Imagers
riešenia na presné meranie
http://www.elso.sk
The rugged and affordable tools for electricians and technicians
Get the full picture instantly with the Fluke Ti9/Ti10/Ti25 thermal imagers. Built for tough work environments, these fully radiometric imagers are ideal for detecting problems in a wide range of equipment including switchgear, motor control centers and lighting systems.
• Delivers the clear images to nd problems fast with its 160x120 sensor
• Even the smallest details become visible with the large, widescreen full color LCD display
• Optimized for eld use in harsh work environments
- Engineered and tested to withstand a 2 meter drop
- Withstands dust and water – tested to an IP54 rating
- Innovative protective lens cover protects the lens when not in use
Fluke Ti25
• Enhanced problem detection and analysis capabilities with patent pending IR-Fusion® Technology (Ti10 and Ti25)
• Intuitive, three-button menu is easy to use ... simply navigate with the push of a thumb
• Store more than 3.000 screen images (.bmp format) or 1.200 fully radiometric images (.IS2 format) on included 2 GB SD memory card
Fluke Ti10
Fluke Ti9
IR-Fusion
See things both ways—infrared and visual (visible light) images fused together communicating critical information faster and easier—traditional infrared images are no longer enough. IR-Fusion, a patent-pending technology that simultaneously captures a digital photo in addition to the infrared image and fuses it together taking the mystery out of IR image analysis. IR-Fusion is standard on Ti10 and Ti25 models. The Fluke Ti9 can be upgraded to a full Fluke Ti10 with IR-Fusion at a later time.
®
Technology
68
Page 71
Ti9/Ti10/Ti25 Thermal Imagers
riešenia na presné meranie
http://www.elso.sk
Specifications
Thermal imaging performance
Detector type 160 x 120 Focal Plane Array, uncooled microbolometer Field of view (FOV) 23 º horizontal x 17 º vertical Spatial resolution (IFOV) 2.5 mRad Min focus distance 15 cm Thermal sensitivity (NETD) ≤0.2 °C at 30 °C (200 mK) ≤0.13 °C at 30 °C (130 mK) ≤0.09 °C at 30 °C (90 mK) Minimum span (auto/manual) 10 ˚C / 5 ˚C 10 ˚C / 5 ˚C 2.5 °C / 5 °C Focus Manual
Visual imaging performance
Minimum focus distance 46 cm 46 cm On camera operating modes Picture-in-Picture and full
Visible light camera 1.3 MegaPixel 1.3 MegaPixel
Temperature measurement
Temperature range -20 ˚C to 250 ˚C -20 ˚C to 250 ˚C -20 ˚C to 350 ˚C Accuracy ± 5 °C or 5% ± 2 °C or 2% ± 2 °C or 2% Measurement modes
Image presentation
Digital display 9.1 cm (3.6”) landscape color VGA (640x480) LCD LCD backlight Selectable bright or auto Palettes
Image and data storage
Storage medium 2GB SD Card (3000 .bmp IR images/1200 .IS2 images)
File formats supported JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Controls and adjustments
Set-up controls Date/time, Cº/ºF, language Date/time, Cº/ºF, language
Language selection Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur Image controls Smooth auto scaling and manual scaling
Power
Battery type Internal rechargeable battery NiMh (included) Battery operating time 3 to 4 hours continuous operation
Fluke Ti9 Fluke Ti10 Fluke Ti25
screen IR plus
Center point Center point Center point and hot and
Ironbow, blue-red, high contrast, grey Ironbow, blue-red, high
Picture-in-Picture and full
screen IR plus Blending
cold markers
contrast, grey, amber and
hot metal
On screen emissivity correction On-screen reflected background
temperature compensation
Water and dust resistant: IP54 Size (HxWxD): Ti9/Ti10/Ti25: 267 x 127 x 152 mm Weig ht: Ti9/Ti10/Ti25: 1.2 kg Two Years Warranty
Complete package
Included Accessories
SmartView® software 2 GB SD card SD card reader Rugged hard carrying case Soft carrying case Hand strap Rechargeable battery AC charger/power supply User manual
Ordering Information
Fluke Ti9 Electrical Thermal Imager Fluke Ti10 Electrical Thermal Imager Fluke Ti25 Industrial Thermal Imager
Recommended Accessories
Ti-Visor
Sun Visor
(for complete Ti Series)
Ti-Car Charger
Car charger
69
Page 72
New
riešenia na presné meranie
http://www.elso.sk
Fluke TiS
TiS/TiR/TiRx/TiR1
Thermal Imagers
for Building Diagnostics
Entry-level Thermal Imager
Fluke’s entry level thermal imager for quick, easy, and accurate problem identication and troubleshooting designed specically for the building inspection professional. Whether you are a building inspector, plumber, roofer, electrician, energy auditor, HVAC, insulator, or windows installer the Fluke Thermal Imaging Scanner is the perfect tool to help you identify hidden building construction issues, nd moisture intrusion, detect energy loss/missing insulation, and many basic electrical connection and load problems. Now Fluke quality, durability, and performance are available in a thermal imager engineered for the valueconscious building professional. The Fluke TiS Thermal Imaging Scanner is the top-performing imager in its price class.
• Highest resolution (120x120) in price class
• Only imager in price class with versatile, manual focus
• Largest display size (3.7”) in price class.
• Long battery life lasts ~4 hours
• Rugged body engineered to withstand 2 m drop test
• Easy to use—the TiS Thermal Imaging Scanner provides you with a basic, reliable solution for the building professional
• NETD 100 mK
Fluke TiR
Fluke TiRx
Optimized for energy audits, restoration and remediation
The affordable rugged Fluke TiRx and TiR Thermal Imagers are workhorse tools for the demands of building envelope, restoration and remediation, inspection and roong applications. Whether to perform energy audits, locate the origins of construction problem or to nd roof leaks, the TiRx and TiR offer an economical solution for complete detection, analysis and documentation.
• Delivers the clear images to nd problems fast with its 160x120 sensor
• Enhanced problem detection and analysis capabilities with patent pending IR-Fusion® Technology (TiR)
• The Fluke TiRx can be upgraded to a full Fluke TiR with IR-Fusion at a later time.
• NETD 90 mK
The professional’s choice
The TiR1 Thermal Imager is the professional’s choice for building diagnostics. The Fluke TiR1 has all the features of the Fluke TiR, but with an NETD of 0.07ºC for the TiR1 to identify even small temperature differences that could indicate problems.
®
• IR-Fusion picture-in-picture views)
• Voice recording; record ndings by speaking into the camera. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference
• NETD 70 mK
, full option (combines visible image with IR image in full screen or
70
Fluke TiR1
Page 73
TiS/TiR/TiRx/TiR1
riešenia na presné meranie
http://www.elso.sk
Thermal Imagers
for Building Diagnostics
Specifications
Thermal imaging performance
Detector type 120 x 120 Focal Plane
Field of view (FOV) 17 º horizontal x 17 º
Spatial resolution (IFOV) 2.5 mRad Min focus distance 15 cm Thermal sensitivity (NETD) ≤0.1 °C at 30 °C
Minimum span 5 ˚C (in auto mode) 2.5 ˚C / 5 ˚C (Auto/Manual) Focus Manual
Visual imaging performance
Minimum focus distance - 46 cm On camera operating modes - Picture-in-Picture and full screen IR Picture-in-Picture and
Visible light camera 1.3 MegaPixel
Temperature measurement
Temperature range -20 ˚C to 100 ˚C -20 ˚C to 150 ˚C Accuracy ± 5 °C or 5% ± 2 °C or 2% Measurement modes
Image presentation
Digital display 9.1 cm (3.6”) landscape color VGA (640x480) LCD
LCD backlight Selectable bright or auto
Palettes
Image and data storage
Storage medium 2GB SD Card (3000 .bmp IR images/1200 .IS2 images) File formats supported JPG, JPEG, JPE, JFIF, BMP, GIF, DIB, PNG, TIF, and TIFF
Controls and adjustments
Set-up controls Date/time, Cº/ºF, language
Language selection Eng, ger, fre, spa, por, ita, swe, fin, rus, cze, pol, tur Image controls Smooth auto-scaling
Power
Battery type Internal rechargeable battery NiMh (included) Battery operating time 3 to 4 hours continuous operation
Fluke TiS Fluke TiRx Fluke TiR Fluke TiR1
Array, uncooled microbolometer
vertical
Ironbow, blue-red,
greyscale
and lock of level and
span
(100 mK)
160 x 120 Focal Plane Array, uncooled microbolometer
23 º horizontal x 17 º vertical
≤0.09 °C at 30 °C
(90 mK)
Center point Center point and hot
Ironbow, blue-red, high contrast, grey Ironbow, blue-red, high
Smooth auto scaling and manual scaling
contrast, grey, amber
Date/time, Cº/ºF, language
correction On-screen reflected background
≤0.07 °C at 30 °C
(70 mK)
full screen IR plus
Blending
and cold markers
and hot metal
On screen emissivity
Complete package
Included Accessories
SmartView® software 2 GB SD card SD card reader Rugged hard carrying case Soft carrying case Hand strap Rechargeable battery AC charger/power supply User manual
Ordering Information
Fluke TiS Thermal Imaging Scanner Fluke TiRx Inspector Thermal Imager Fluke TiR Thermal Imager for Building Diagnostics Fluike TiR1 Thermal Imager for Building Diagnostics
Water and dust resistant: IP54 Size (HxWxD): 267 x 127 x 152 mm Weig ht: 1.2 kg Two Years Warranty
Recommended Accessories
Ti-Visor
Sun Visor
(for complete Ti Series)
Ti-Car Charger
Car charger
FLK-TI-SBC3
Charging base (Ti32)
71
Page 74
CRange IRWindows
riešenia na presné meranie
http://www.elso.sk
Increase the safety and speed of electrical thermography
Infrared windows mount into panel doors and covers for switchgear, transformers, bus bars and other live electrical equipment, allowing Infrared, Ultraviolet, Visual and IRfusion technologies to be used without exposing personnel to live equipment. All infrared windows from Fluke use the unique Quadraband™ multispectral optic, allowing inspection with any camera for total exibility both now and in the future.
• Reduce the arc ash risk associated with electrical thermography
• Increase efciency as thermographer can work alone without being accompanied by an electrician to isolate and open panels
• Stay safety compliant with NFPA70E and other safety protocols and leave the panels closed
• Extend the life of your equipment with more frequent IR scans
• Easy to install
• Durable enough to withstand extreme outdoor conditions yet practical for indoor applications as well.
Included Accessories
Installation CD, self-adhesive drilling template, security access key, warranty statement.
Ordering Information
FLK-075-CLKT 75mm C-Range IR Window, Kwik Twist FLK-100-CLKT 100mm C-Range IR Window, Kwik Twist IP-200-UK Window Installation Kit 220/240V
Specifications
(Check the Fluke web for detailed specifications)
Optic Data
Crystal Insert Diameter 75 mm 100 mm Viewing Aperture Diameter 68 mm 89 mm Viewing Aperture Area 3632 mm Thickness 2 mm 4 mm CLIRVU Coating Shortwave IR Capable Midwave IR Capable Longwave IR Capable Ultraviolet (UV) Capable Visual Capable Fusion Capable
General
Maximum Temperature Gaskets 250º C Body 659 º C Optic 1400º C Gaskets Low Smoke & Fume (LSF) compliant silicone IP rating IP65 NEMA rating Typo 3/12 (UL & CSA Third Party Certified) Vibration rating IEC60068-2-6 Humidity rating IEC60068-2-3 Pull out strength Up to 630 kg
Warranty: Lifetime replacement against manufacturing defects
FLK-075-CLKT FLK-100-CLKT
2
6322 mm2
OO OO OO OO OO OO OO
72
Page 75
Laser Distance Meters
riešenia na presné meranie
http://www.elso.sk
The Fluke Laser Distance Meters bring you the most advanced measuring technology. Unlike ultrasonic distance meters with laser pointers, these meters use a precision narrow laser beam that can avoid the common errors caused by extraneous objects near measurement targets.
73
Page 76
421D, 416D, 411D
riešenia na presné meranie
http://www.elso.sk
Laser Distance Meters
Professional-grade laser distance measuring tools that are fast, easy to use, and fit in your pocket.
The Fluke laser distance meters bring you the most advanced measuring technology. These meters are fast, accurate, durable, and easy to use — just point and shoot. Their straightforward design and easy, one-button operation mean you spend less time measuring. Unlike ultrasonic distance meters with laser pointers, the Fluke 421D, 416D and 411D use a precision narrow laser beam that can avoid the common errors caused by extraneous objects near measurement targets.
These compact and handy Fluke distance meters are designed for indoor, and limited outdoor applications. Addition, subtraction, area, and volume calculations could not be simpler. The extra bright laser is clearly visible so you can see your targeting point even if an object is hard-to-reach or distant. The Fluke 421D, 416D and 411D have a large LCD screen and buttons positioned for one­handed measurements.
Fluke 421D
Fluke 416DFluke 411D
411D/62 Kit
Combo kit includes:
- Fluke 62 Mini IR Thermometer
- Fluke 411D Laser Distance Meter
- Soft pouch for each model
Included Accessories
Two AAA batteries, Users manual on CD, Quick start guide, Nylon carrying case, Wrist wrap (421D)
Features
411D 416D 421D
Reduction of estimation errors, saving both time and money
Instant measurement with one-button operation
Easy targeting with bright laser
Quick calculation of area (square footage) and volume
Easy addition and subtraction of measurements
Improved battery life from automatic shut-off feature
Pythagoras calculation for determining distance indirectly from two other measurements
Pouch
Ability to view more with large, 3-line display with backlight
Ability to measure up to 30 m 60 m 100 m
Storage capacity of measurements for quick recall of distance - 10 20
MIN/MAX function
Enhanced Pythagoras calculation for determining distance indi­rectly from three other measurements
Audible feedback of on and off modes
Strong environment protection with IP54 (water spray & dust proof) sealing
Audible feedback for taking room angle and incremental measurements
± 45° Tilt sensor for taking indirect measurements in hard to reach areas
Tripod mode allows you to mount to a tripod for measuring long distances
Built in light sensor for activating the backlight saving battery life
Corner angle feature, allows you to determine the angle of a corner
OOO
OOO
OOO
OOO
OOO
OOO
OOO
OOO
OO
OO
OO
OO
OO
O
O
O
O
O
Specifications
(Check the Fluke web for detailed specifications)
Fluke 411D Fluke 416D Fluke 421D
Range (for extended distances, use a target plate) 30 m 60 m 100 m
Accuracy ± 3 mm ± 1.5 mm ± 1.5 mm
Measurement units 00.000 m 00.000 m 00.000 m
Measurement storage 10 locations 20 locations
Backlight
Automatic power off After 180 seconds After 180 seconds After 360 seconds
Operating temperature: 0°C to 40°C Storage temperature: -25°C to 70°C Operating altitude: up to 3500 m Battery Life: 411D: up to 3000 readings 416D, 421D: up to 5000 readings
Size (HxWxD): 411D: 123 mm x 50 mm x 26 mm 416D: 135 mm x 46 mm x 31 mm 421D: 127 mm x 52 mm x 25 mm Weight: 411D: 0.150 kg
416D: 0.110 kg 421D: 0.125 kg Warranty: 2 years
OO
Ordering Information
Fluke 411D Laser Distance Meter Fluke 416D Laser Distance Meter Fluke 421D Laser Distance Meter
6574
Page 77
Indoor Air Quality Tools
riešenia na presné meranie
http://www.elso.sk
In response to the growing importance of air quality in buildings, workplaces and homes, Fluke offers you a range of tools that monitor temperature, humidity, air velocity, particulate, and carbon monoxide levels. These tools help you to quickly and easily troubleshoot and maintain indoor air quality, as well as to verify the efcient operation of heating, ventilation and air conditioning systems.
75
Page 78
Fluke 975
riešenia na presné meranie
http://www.elso.sk
975 AirMeter
Combined inspection tool for complete air quality inspections
The Fluke 975 AirMeter combines ve air monitoring tools into one, rugged and easy-to-use handheld tool. Use the Fluke 975 to verify the efcient operation of heating, ventilation and air conditioning systems, and test for dangerous carbon monoxide leaks in all types of buildings.
Specifications
Feature Range Display resolution Accuracy
Measured specifications
Temperature -20 °C to 60 °C 0.1 °C ± 0.9 °C from 40 °C to 60 °C
Relative humidity 10 % to 90 % RH non-
Air velocity 50 fpm to 3000 fpm
CO
2
CO 0 to 500 ppm 1 ppm ± 5 % or ± 3 ppm,
Calculated specifications
Dew point temperature -44 °C to 57 °C 0.1 °C ± 1 °C when temp: -20 °C to 60 °C
Wet bulb temperature -16 °C to 57 °C 0.1 °C ± 1.2 °C when RH: 20 % to 90 %
Volume flow rate (in a duct) 0 to 3,965 M
% outside air (based on temperature) 0 to 100 % 0.1 % N/A % outside air (based on CO2) 0 to 100 % 0.1 % N/A
condensing
0.25 m/sec to 15 m/sec
0 to 5000 ppm 1 ppm Warm up time 1 min
140,000 cfm)
• Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
• One-touch air ow and velocity measurements with available probe
• Min/Max/Average on all measured and calculated readings
• Audible and visual threshold alarms
• Multi-language user interface
• Extensive discrete or continuous data logging capacity, down-loadable to PC via USB interface
(Check the Fluke web for detailed specifications)
± 0.5 °C from 5 °C to 40 °C
1 % ± 2 % RH (10 % RH
1 fpm
0.005m/sec
3
/m 0 to
0.001 M3/min (1 cfm) N/A: The volume flow
± 1.1 °C from -20 °C to 5 °C
to 90 % RH) 4 % or 4 fpm* 3 % or 0.015 m/sec* whichever is greater *Accuracy specification only valid for velocity readings above 50 fpm.
(5 minutes for full specification)
2.75 % + 75 ppm
whichever is greater, @ 20 °C and 50 % RH
RH: 40 % to 90 % ± 2 °C when temp: -20 °C to 60 °C RH: 20 % to 40 % ± 4 °C when RH: 10 % to 20 %
temp: -20 °C to 60 °C ± 2.1 °C when RH: 10 % to 20 %
calculation will be a simple average of the data points times the duct area
Included Accessories
A4 alkaline batteries (3), Users Manual, Calibration Cap, FlukeView Forms Software, Power Adapter, International Power Plugs, Air Velocity Probe (Fluke 975V only)
Ordering Information
Fluke 975 AirMeter Fluke 975V AirMeter with Velocity 975R Regulator 975VP Air Velocity Probe
76
Operating temperature
(CO and CO2 sensors): -20 °C to 50 °C
Operating temperature
(all other functions): -20 °C to 60 °C
Storage temperature: -20 °C to 60 °C Humidity: 10% to 90% Altitude: Up to 2000 m
Shock and vibration: MIL-PRF-28800F, Class 2 Battery: Rechargeable Li-Ion (primary), three-
AA (backup)
Weig ht: 0.544 kg Size (HxWxD): 28.7 cm x 11.43 cm x 5.08 cm Data logging: 25,000 records (continuous),
99 records (discrete) Multilanguage interface: English, French, Spanish, Portuguese and German
Two-year warranty
Recommended Accessories
975VP
AirMeter Velocity Probe
Page 79
Fluke 922
riešenia na presné meranie
http://www.elso.sk
922 Airflow Meter
Measures pressure, air flow and velocity for maintaining balanced and comfortable ventilation
The Fluke 922 makes airow measurements easy by combining pressure, air ow, and velocity into a single, rugged meter. Compatible with most Pitot tubes, the Fluke 922 allows technicians to conveniently enter their duct shape and dimensions for maximum measurement accuracy.
Use the Fluke 922 to: Ensure proper air ow balance and maintain a comfortable environment; measure pressure drops across lters and coils; match ventilation to occupant loads; monitor indoor vs. outdoor pressure relationships and manage the building envelope; and perform duct traversals for accurate airow readings.
Feature Range Resolution Accuracy
Operating Specifications
Air Pressure ± 4000 Pascals
Air Velocity 250 to 16,000 fpm
Air Flow (Volume) 0 to 99,999 cfm
Temperature 0 °C to 50 °C 0.1°C ± 1 % + 2 °C
± 16 in H2O ± 400 mm H2O ± 40 mbar ± 0.6 PSI
1 to 80 m/s
0 to 99,999 m 0 to 99,999 l/s
• Provides differential and static pressure, air velocity and ow readings
• Convenient colored hoses help you properly diagnose pressure readings
• Bright, backlit display for clear viewing in all environments
• Min/Max/Average/Hold functions for easy data analysis
• Auto power off saves battery life
Specifications
(Check the Fluke web for detailed specifications)
3
/hr
1 Pascal
0.001 in H2O
0.1 mm H2O
0.01 mbar
0.0001 PSI 1 fpm
0.001 m/s 1 cfm
1 m3/hr
1 l/s
± 1% +1 Pascal ± 1% + 0.01 in H2O ± 1% + 0.1 mm H2O ± 1% +0.01 mbar ± 1% + 0.0001 PSI
± 2.5 % of reading at 10 m/s (2000 p/min)
Accuracy is a function of velocity and duct size
Included Accessories
Fluke 922: Two Rubber Hoses, Wrist Strap, Four AA Batteries 1.5 V Alkaline, Users Manual and Soft Carrying Case Fluke 922 Kit Includes: Fluke 922 Airflow Meter,
30.48 cm Pitot tube, ToolPak, Two Rubber Hoses, Wrist Strap, Four AA Batteries 1.5 V Alkaline, Users Manual and Hard Carrying Case
Ordering Information
Fluke 922 Air Flow Meter Fluke 922/Kit Airflow Meter with
30.48 cm Pitot Tube
General Specifications
General specifications
Operating Temperature 0 ºC to +50 ºC Storage Temperature -40 ºC to +60 ºC Operating Relative Humidity Non condensing (<10 ºC)
IP Rating IP40 Operating Altitude 2000 m Storage Altitude 12000 m EMI, RFI, EMC Meets requirements for EN61326-1 Vibration MIL-PREF-28800F, Class 3 Max Pressure at Each Port 10 PSI
Data Storage: 99 readings Size (HxWxD): 175 x 775 x 419 mm Weig ht: 0.64 kg Battery: Four AA batteries Battery Life: 375 hours without backlight,
80 hours with backlight
Two Year Warranty
90% RH (10 ºC to 30 ºC) 75% RH (30 ºC to 40 ºC) 45% RH (40 ºC to 50 ºC) Without Condensation
Fluke 922/Kit
Recommended Accessories
PT12
Pitot Tube, 30.48 cm
TPAK
Toolpak
See page 132
77
Page 80
971 Temperature Humidity Meter
riešenia na presné meranie
http://www.elso.sk
Carbon Monoxide Meters
Fluke 971 Temperature Humidity Meter
Fluke 971
Other useful tools
Quickly take accurate humidity and temperature readings in the air. Temperature and humidity are two important factors in maintaining optimal comfort levels and good indoor air quality. The Fluke 971 is invaluable for facility maintenance and utility technicians, HVAC-service contractors, and specialists who assess indoor air quality (IAQ). Lightweight, rugged, and easy to hold, the Fluke 971 is the perfect tool for monitoring problem areas.
Temperature range -20 ºC to 60 ºC Temperature accuracy
0 ºC to 45 ºC
-20 ºC to 0 ºC and 45 ºC to 60 ºC Resolution 0.1 ºC Response time (temperature) 500 ms Temperature sensor type NTC Relative humidity range 5% to 95% R.H. Relative humidity accuracy
10% to 90% R.H. @ 23 ºC <10%, >90% R.H. @ 23 ºC
Humidity sensor Electronic capacitance polymer film sensor Data storage 99 points Response time (humidity) For 90% of total range - 60 sec with 1 m/s air movement
± 0.5 0C ± 1.0 ºC
± 2.5 % R.H. ± 5.0 % R.H.
• Simultaneously measures humidity and temperature
• Measures dew point and wet bulb
• 99 record storage capacity
• Min/Max/Avg Data Hold
• Ergonomic design with built-in belt clip and protective holster
• Backlit, dual readings display
• Twist-open protective cap
• Low battery indicator
Specifications
Fluke 561
Combined Contact and Non-contact
Fluke 416D
Laser Distance Meter
See page 74 . Thermometer See page 54.
Included Accessories
Fluke CO-220: C50 soft carrying case and battery
Ordering Information
Fluke 971 Temperature Humidity Meter Fluke CO-220 Carbon Monoxide Meter CO-205 Aspirator Kit
Operating temperature:
Temperature: -20 °C to 60 °C Humidity: 0 °C to 60 °C
Storage temperature: : -20 °C to 55 °C Battery life: 4 AAA alkaline, 200 hours
Safety: Complies with EN61326-1 Weig ht: 0.188 kg Size (HxWxD): 194 mm x 60 mm x 34 mm One Year Warranty
Carbon Monoxide Meters
CO-220 Carbon Monoxide Meter
The CO-220 Carbon Monoxide Meter makes it easy to take quick and accurate measurements of CO levels. A large, backlit LCD display shows CO levels from 0 to 1000 PPM. The MAX Hold function stores and displays the maximum CO level. 1 year warranty.
CO-205 Aspirator Kit
Allows flue gas samples up to 371°C to be drawn with the CO-220 for carbon monoxide measurement. 1 year warranty.
Fluke CO-220
Fluke CO-205
78
Page 81
983 Particle Counter /
riešenia na presné meranie
http://www.elso.sk
RLD2 Leak Detector Flashlight
Easy to use tool for troubleshooting and maintaining indoor air quality
The Fluke 983 Particle Counter simultaneously measures and displays six channels of particle size distribution, temperature and humidity. This compact, lightweight, self-contained tool allows for one-handed operation. As the Fluke 983 doesn’t require level holding, it can make accurate measurements in any position. The 8 hour rechargeable battery together with a large 5000 sample record allows for complete air quality surveys in one go. The Fluke 983 is the ideal tool for determining size distribution of airborne particles or tracking down a particle source.
• Simultaneously measure and display 6 channels of particle sizes, temperature and humidity
• Measure particle size down to 0.3 µm
• Selectable sample time, count data, programmable delay
• Store 5000 records of date, time, counts, relative humidity, temperature, sample volumes, alarms and location label
• Upload stored data to a PC with included software
• Compact, self-contained package allows for one-handed operation
• Intuitive, easy-to-use user interface
• Always ready to run, with no uids to rell
• Backlit LCD for use in any lighting condition
Specifications
Fluke 983
Included Accessories
Fluke 983:
Certificate of Calibration (NIST) Isokinetic probe Zero count filter Windows-compatible software download utility DB9 to RS-232 adapter and cable High purity tubing 1/8 in. hose barb adapter Power supply Operation manual Hard molded carrying case Fluke RLD2: Key chain carabiner and batteries.
Ordering Information
Fluke 983 Particle Counter Fluke RLD2 Leak Detector Flashlight
6 size channels 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 µm Flow rate 0.1 cfm (2.83 L/min) controlled by internal pump Count modes Concentration, totalize, audio Counting efficiency 50 % @ 0.3 µm; 100 % for particles > 0.45 µm (per JIS B9921:1997) Zero count 1 count/5 minute (per JIS B9921:1997) Coincidence loss 5 % at 56,000 particles per m Relative humidity ± 7 %, 20 % to 90 %, non-condensing Temperature ± 3 °C, 10 °C to 40 °C Data storage 5000 sample records (rotating buffer) of date, time, counts, relative humidity,
Alarms Counts, low battery, sensor fail Delay time 0 to 24 hours Sample inlet Isokinetic probe Interface RS-232 and RS-485 via RJ-45 Calibration PSL particles in air (NIST traceable)
Operating temperature: 10 °C to 40 °C, 20 % to 90 % relative humidity, non-condensing Storage temperature: -10 °C to 50 °C, up to 90 % relative humidity, non-condensing
Power: AC adapter, 90 to 250 V AC, 50 to 60 Hz Battery life/recharge time: 8 hours/2 hours
temperature, sample volumes, alarms, label
3
Rechargeable battery: NiMH, 4.8V at 4.5 Ah; replaceable
Size (HxWxD): 209 mm x 114 mm x 57 mm Weig ht: 1 kg Warr anty: 1 year
RLD2 Leak Detector Flashlight
RLD2 Leak Detector Flashlight.
Leak detection made easy. The compact RLD2 uncovers refrigerant leaks instantly. Use the UV light to nd the leakage area, then, use the laser pointer to pinpoint the exact leak location.
• Six UV LEDs detect leak detection dyes
• Laser pointer clearly locates center of the UV eld for accuracy
• Three LED ashlight with 100,000 hour LED life
• Operating temperature 0ºC to 50ºC
• Four operating modes: ashlight, UV light, laser light, UV/laser light combination
• One year warranty
79
Page 82
ScopeMeter® Test Tools
riešenia na presné meranie
http://www.elso.sk
ScopeMeter portable oscilloscopes take you into territory standard bench scopes can’t go: where it’s harsh, hazardous and dirty – without sacricing any capabilities. They provide you with unmatched speed, performance and analysis power while working on site.
8080
Page 83
New
riešenia na presné meranie
http://www.elso.sk
ScopeMeter 190 Series II
The toughest portable scopes ever built
Combining rugged portability with the performance of a bench scope, the Fluke 190 Series can take you from troubleshooting microelectronics all the way into power electronic applications. See more, x more and go where you’ve never gone with a scope before.
The first high-performance two and four Channel scopes built for harsh industrial environments.
Introducing the rst high-performance portable oscilloscopes with 2 or 4 independently insulated input channels, an IP51 dust- and drip waterproof rating and a CAT III 1000 V / CAT IV 600 V safety rating. Choose from 500 MHz, 200 MHz, 100 MHz or 60 MHz bandwidth models. Now plant maintenance engineers can take a four-channel scope into the harsh world of industrial electronics. Safely troubleshoot three-phase systems like variable speed drives, UPS or back-up generators. Measure input, output and feedback signals simultaneously to diagnose industrial electronics.
• 4 independent isolated input channels enable 3-axis industrial testing, simultaneous testing of input signals, output signals and feedback loops or safety interlocks
• 190-XX4 model with four independent isolated inputs
• 190-XX2 models with two independenet isolated scope inputs and DMM input
• Fast sample rate: up to 5 GS/s with up to 200 ps resolution
• Single shot, pulse width and video triggering
• Deep memory: 10,000 points per trace waveform capture
• CAT III 1000 V / CAT IV 600 V, safety rated
• Up to seven hours of operation with high performance Li-ion batteries, that extend usage time plus optional external charger
• Battery door for conveniently swapping out
• Two isolated USB ports, for memory devices and PC connectivity
• Security slot to lock down instrument using standard Kensington® lock
• Connect & View™ triggering for intelligent, automatic triggering on fast, slow and even complex signals
• Frequency Spectrum using FFT analysis
• Automatic capture and REPLAY of 100 screens
• ScopeRecord™ mode gives 30000 points or more per input channel for low frequency signal analysis
• TrendPlot™ paperless recorder mode with deep memory for long-term automatic measurements
What could you do with four channels?
Take multiple measurements simultaneously to track down the root cause of your most complex troubleshooting challenges.
• Easily diagnose timing-related issues with multiple signals
• Real-time inspection of multiple signals simultaneously
• Meaure a combination of input and output signals and system safety interlocks and feedback loops
Fluke 190-502 brings wide bandwidth test applications in the palm of your hand!
With the new 500 MHz model, the verication of telecommunication equipment, high frequency and wide bandwidth systems such as radar equipment has become truly portable. Conveniently verify the systems performance right ‘on the spot’, fully safely without carrying bulky lab equipment around. Battery powered and fully oating – up to 600V CAT III, for each channel and in between channel references.
Application driven
Find problems in industrial systems including:
• Circuit voltage/current overloading
• Attenuation/input impedance mismatch
• Signal uctuation/drift
• Conditioning circuits signal integrity
• Test point verication for critical signals
• Input/output/feedback timing issues
• Induced noise and disturbances
• Random shutdowns/reset
Diagnose VSDs* or power inverters and converters
• Harmonics, transients and loads in three phase power input
• Troubleshoot dc to ac converters for faulty control circuits or output IGBT gate stages
• Cable interface - test PWM output for reections and transients
• Vpwm measurement to measure the effective voltage on drive outputs
Technologies Electrical Electromechanical Process Controls Automation Medical Imaging Avionics
Equipment Switch Gear,
Interlocks,
Motors, Pumps,
Fans,
Furnaces,
Presses,
Mixers,
Refrigeration
Actuators,
VFD Drives,
Linear Motors,
Pressure-Level-
Flow-Position
Sensors,
Packaging
Equipment
Transducers,
Sensors,
Loop Controllers,
Calibrated Gauges
PLC´s,
Sensors,
Transducers,
Motion
Controllers,
Rotory Encoders, Scanners,
Readers, Printers
XRay,
MRI,
Ultrasound
Imaging
equipment
Flight Line Navigation
Systems,
Communication
systems,
Radar,
On board
aircraft control
systems
A/V & Security
Systems
Retail security
devices,
Surveillance and
monitoring equipment,
RFID
81
Page 84
ScopeMeter 190 Series II
riešenia na presné meranie
http://www.elso.sk
New
Fluke 190-204
Multiply your diagnostic powers with the new Fluke 190 Series II portable oscilloscopes
Rated all the way to CAT IV
ScopeMeter test tools are rugged solutions built for industrial troubleshooting. The new Fluke 190 Series II are double-insulated oating oscilloscopes safety rated for measurements up to CAT III 1000 V/CAT IV 600 V environments. The new 500 MHz model is rated all the way up to 600 V CAT III.
Measure from mV to kV safely
Independently isolated inputs allow you to make measurements in mixed circuits having different ground references reducing the risk of accidental short circuits. Conventional bench oscilloscopes without special differential probes and isolation transformers can only reference measurements to line power earth ground. With standard probes that cover a wide application range from mV to kV, you are ready for anything from micro-electronics to heavy-duty higher voltage electrical applications.
IP-51 rated for harsh environments
Rugged and shock-proof, ScopeMeter portable oscilloscopes are built for dirty, hazardous environments. With its sealed case, it can endure dust, drips, humidity and airborne pollutants. Every time you reach for ScopeMeter you can be condent it will work reliably wherever your work takes you.
82
Fluke 190-202
True RMS
Optional Accessories
C290 Hard shell protective carrying case for 190 Series II HH290 Hanging Hook for 190 Series II instruments SCC290 FlukeView Software (full version) and C290 Carrying Case kit VPS410-R Voltage Probe set, 10:1, 300 MHz, one set red VPS410-G Voltage Probe set, 10:1, 300 MHz, one set grey VPS410-B Voltage Probe set, 10:1, 300 MHz, one set blue VPS410-V Voltage Probe set, 10:1, 300 MHz, one set green VPS420-R High working voltage probe set 150 MHz, 100:1, CAT III 2000 V (1000 V to earth) BC190 Mains adapter/battery charger EBC290 External battery charger for BP290 and BP291 TL175 TwistGuard™ safety designed Test Leads set (1 red, 1 black) BP290 Li-Ion battery pack, 2400 mAh BP291 Li-Ion battery pack, 4800 mAh SW90W FlukeView® ScopeMeter Software for Windows VPS510-X Wide bandwidth probe set, 10:1, 500 MHz, 600V CAT III
®
USB connectivity makes it easy to capture and share waveforms
The new Fluke 190 Series II offers two USB ports, electrically isolated from measurement input circuits. Easily transfer data to a PC. Archive and share waveforms with OEMs, colleagues and support staff. Store waveforms, screen captures and instrument setups onto USB memory devices.
FlukeView ScopeMeter software for documenting, archiving and analysis
Get more out of your ScopeMeter with FlukeView® ScopeMeter® SW90W Software for Windows.
• Documentation—transfer waveforms, screens and data to your PC for printing or importing data into a report
• Add text to ScopeMeter settings—give operators guidance when recalling settings
• Archive—create a library of waveforms for easy reference, waveform comparison, or pass/fail testing
• Analysis—use cursors, perform spectrum analysis or export data to another analysis program
Page 85
Figure 1.
G703 - E1 template
Application Note
From the Fluke Digital Library @ www.fluke.com/library
The G.703 standard
G.703 is a standard origi-
nally introduced for voice and
data transmission over digital
networks. It is an ITU recom-
mendation (formerly CCITT)
that’s associated with the PCM
standard. Analog-voice to digital-
data conversion according to PCM requires a bandwidth of
64 kb/s (±100 ppm), resulting in
the basic unit for G.703. Through multiplexing this results in a T1
of 1.544 Mb/s and E1 of
2.048 Mb/s. The electrical characteristics
of the network interfaces are
described in recommendation
G.703. The signal limits for a
2.048 Mb/s signal are shown in Figure 1.
Multiple-channel
testing using two
different masks
A balun is used between the
patch panel and a coaxial
transmission line to match the
impedance of the 120 Ω sym-
metrical line to a 75 Ω coaxial line. The input and output of the
balun each has its specific mask.
The ScopeMeter 190 Series II
portable oscilloscopes can simul-
taneously perform a pass/fail test
at the input and output of the
balun with different masks.
The floating and isolated
inputs of the Fluke ScopeMeter
190 Series II test tools make these measurements pos-
sible without the risk of making
unwanted groundings. Moreover,
the high impedance probes allow for direct measurements without
loading the line and without the
need for an external differential
probe.
Testing telecommunication
equipment using Pass/Fail
mask testing with a Fluke
ScopeMeter
®
190 Series II
Editing the pass/fail
templates
With FlukeView we can export
a waveform into a spreadsheet and a custom template can be
created by editing a waveform
using Excel.
A reference template for
pass/fail testing can be cre-
ated by saving waveforms from
FlukeView in .csv format and
editing the waveform using, for
Figure 2. ISDN30 network
ISDN 30
Patch
Panel
Balun SDH
Distr.
Nowadays digital communication systems such as Synchronous
Digital Hierarchy (SDH) in Europe and the Synchronous Optical
Network (SONET) in North America require standard test methods.
The electrical signals are tested against the standard ITU pulse
masks. The Fluke ScopeMeter 190 Series II portable oscilloscope
offers a standard pass/fail function that can be used to perform
these tests. The instrument is capable of storing up to 100 “fails”
for further analysis.
Demystifying
drive anomalies
using the Fluke 190 Series II 2-Channel
ScopeMeter
®
portable oscilloscope
From the Fluke Digital Library @ www.fluke.com/library
Seeing is believing? More aptly, seeing is
understanding.
If anyone can wring every last ounce of functionality out
of a piece of electronic test equipment, it’s Chris Vogel.
At Siemens Building Technologies, Vogel has his work cut out for him keeping HVAC systems running for the com-
pany’s large commercial customers in Florida’s tropical
weather, which is marked by seemingly nonstop 90 °F
temperatures and 95 % humidity levels. And that’s just one of the challenges faced by technicians at Siemens
Building Technologies, which plays a more sweeping role
in its customers’ success: ensuring energy efficiency, comfort, protection against unauthorized access, and
fire safety year-round for every building or office tower entrusted to it by customers.
Storing a slice of time
It’s important, says Vogel, that the technician be able to characterize VFD problems by
capturing a waveform from the offending drive. His premise: A
signal is much more telling when presented in a waveform view than in a single, static volt-
age reading. The signal has a shape and value that may look
right at a glance, but could just as easily have a distortion or
rough “edge,” or a momentary spike almost too short to be
seen. Either problem, or a host of other signal anomalies, would be indistinguishable with just a
numeric reading of the signal.
“The scope allows me to record information, and from a number of sources—sine waves
on the inputs and outputs of
VFDs, current and voltage—and,
for that matter, make compari-
sons of current and voltage so that I can derive a power factor
for the circuit.”
Operator: Chris Vogel, HVAC
Technician for Siemens Building Technologies
Testing
Functions
Case
Study
ScopeMeter 190 Series II
riešenia na presné meranie
http://www.elso.sk
Application Note
Connect the ScopeMeter
test tool and view the
result: the start of every
measurement
are automatically detected and
It frequently happens that service
adjusted, followed by display-
engineers have to spend a lot of
ing the signal in the correct ratio
time adjusting their measuring
with respect to the horizontal
device such as a portable oscil-
and vertical axis. At least 1.5
loscope for an optimal setting.
to 4 periods of the signal are
Valuable time is spent completing
measured before the pattern is
this set up, and ideally, this could
shown.
be done automatically.
With the introduction of the
a stable, reliable and repeat-
new ScopeMeter 190 Series II,
able display of virtually any
Fluke has revamped its unique
signal, including motor drive and
feature, Connect and View.
control signals, without touch-
Scope users know how dif-
ing a button. Signal changes are
Vogel, an HVAC technician,
ficult triggering can be. Wrong
becomes energized when dis-
instantly recognized and settings
settings show unstable and
cussing the return on investment
adjusted for, once again, a stable
sometimes wrong results. Fluke’s
in his handheld ScopeMeter
®
Test Tool
display. This is all done auto-
unique Connect and View
Test Tool. “Out at one large site,
matically, but manual overruling
recognizes signal patterns, and
where we monitor and trouble-
ScopeMeter
Measuring tools: 190 Series II
2-Channel
Measurements: Current and voltage waveform analysis, power factor
is still possible. If manual over-
automatically sets up correct
shoot variable frequency drives
ruling is needed, the ScopeMeter
triggering, attenuator and time
(VFDs), component-level repair
190 Series will switch from auto-
base settings. Switching on the
can often mean the difference
matic to 1/2 automatic, which is
ScopeMeter portable oscilloscope
between a $20 repair part and
visible on the display.
to display correct signal patterns
a $100,000 repair bill. I know
only takes a couple of seconds,
firsthand, because we recently
the different types of waveforms
and this is exactly what an
documented that very scenario.”
On large VFDs, Vogel uses his
which can de detected by
operator wants.
2 Mb/s
120 Ω
Connect & View. If required the
Settings regarding
ScopeMeter portable oscilloscope
criteria for best settings can be
amplitude,
to uncover capacitance problems,
optimized by switching on one or
timebase,
transistor firing mishaps, and
even bleed-throughs on a gate.
all of the following options:
triggering,
Telephone
“Of course, a transistor is basi-
Exchange
Automatic trigger
etc.
cally a lightning-fast switch,”
Figure 1.
From the Fluke Digital Library @ www.fluke.com/library
Connect and View provides
®
2 Mb/s
2 Mb/s
120 Ω
Figure 1 gives an example of
he says. “It switches back and
forth between open and closed, and it can sometimes start to
break down. When that happens,
motors will start doing weird things. For example, at load
stage we’ll actually see the motor banging back and
forth as if it is not sure which way to turn.”
75 Ω
AC/DC coupling
Glitch detect
Figure 2 shows the different settings.
Application Note
Connect-and-View™ triggering for an instant, stable display
If you’ve used other scopes, you know how tricky triggering can be. If settings are incorrect, results can be unstable or incorrect. Connect-and­View™ automatically sets up correct triggering by recognizing signal patterns. Without touching a button, you get a stable, reliable and repeatable display of virtually any signal including motor drive and control signals. It’s especially fast and convenient when you’re measuring a number of test points in rapid succession.
Connect-and-View™ captures even the most complex motor drive signals.
A range of application notes is available.
See the Fluke website.
Included Accessories
Fluke 190 Series II 4-channel instruments include a set of four probes, hanging strap, handstrap, USB cable with mini-B connector, double capacity Li-ion battery BP291, battery charger/power adapter BC190, a FlukeView demo package and users manuals on CD-ROM. The /S-versions also include the C290 hard-shell carrying case and the FlukeView software package. The 2-channel models come with two probes plus a set of TL175 test leads and a single capacity battery BP290. The 190-502 also includes two pieces TRM50 coaxial feedthrough terminator. The SCC290 kit includes: C290 hardshell carrying case and FlukeView® for Windows® software (full version).
Ordering Information
Fluke-190-502/S Color ScopeMeter (500 MHz, 2 channel), with SCC290-kit Fluke-190-204/S Color ScopeMeter (200 MHz, 4 channel), with SCC290-kit Fluke-190-204 Color ScopeMeter (200 MHz, 4 channel) Fluke-190-202/S Color ScopeMeter (200 MHz, 2 channel), with SCC290-kit Fluke-190-202 Color ScopeMeter (200 MHz, 2 channel) Fluke-190-104/S Color ScopeMeter (100 MHz, 4 channel), with SCC290-kit Fluke-190-104 Color ScopeMeter (100 MHz, 4 channel) Fluke-190-062/S Color ScopeMeter (60 MHz, 2 channel), with SCC290-kit Fluke-190-062 Color ScopeMeter (60 MHz, 2 channel) AS400 Probe Accessory Extension set for VPS400 Series probes BP291 Double capacity Li-Ion battery (4800 mAh) pack for 190C Series II BP290 Single capacity Li-ion battery (2400 mAh) pack for 190-series II C195 Soft padded carrying case for ScopeMeter and accessories C290 Protective Carrying Case for Fluke 190-series II EBC290 External Battery Charger for charging BP290 or BC291 outside the instrument HH290 Hanging Hook RS400 Probe Accessory Replacement set for VPS400 series probes RS500 Probe Accessory Replacement set for VPS510 series probes SCC290 Software and Case kit for Fluke 190 Series 190 Series II. Includes SW90W and C290. SW90W FlukeView® ScopeMeter Software for Windows® (full version) TRM50 Coaxial 50  feedthrough terminator VPS410-x Probe-set, 10:1, 1000V CAT III / 600V CAT IV (colors: blue, green, red, grey) VPS420-R Probe-set, bicolor (r/b), 100:1, 150 MHz, 1000V CAT III / 600V CAT IV, working voltage (voltage between probe tip and reference lead): 2000V CAT III / 1200V CAT IV. VPS510-x Wide bandwidth probeset, 500 MHz, 10:1, 600V CAT III
Built-in digital multimeter
(2 channel models)
190 Series II models with isolated dual input scope and dedicated digital multimeter. Conveniently switch from waveform analysis to precise multimeter measurements using the built in 5000 count digital multimeter. Measurement functions include Vdc, Vac, Vac+dc, resistance, continuity and diode test. Measure current and temperature using suitable shunt, probe or adapter with wide range of scaling factors.
The built in multimeter provides convenient precision measurements.
Automatic capture and replay op 100 screens
Scope users know how frustrating it is to see a one­time anomaly ash by, never to be seen again. Not with the ScopeMeter 190-series! Now you can look back in time with the touch of a button. In normal use, the instrument continuously memorizes the most recent 100 screens. At any moment in time, you can ‘freeze’ these latest screens and scroll through them picture-by-picture or replay them as a ‘live’ animation. Cursors and zoom can be used for further analysis. You can even use the advanced trigger capabilities to capture up to 100 specic events. Two sets of 100 screens with individual time stamps can be stored for later recall or download to a PC.
See dynamic signal behavior instantly
The digital Persistence mode helps to nd anomalies and to analyze complex dynamic signals by showing the waveforms amplitude distribution over time using multiple intensity levels and user selectable decay time – it’s as if you’re looking at the display of an analog, real time oscilloscope! A fast display update rate reveals signal changes instantaneously, useful for instance when making adjustments to a system under test.
Recommended Accessories
SCC290SW90W
EBC290VPS420-R
AS400
83
Page 86
ScopeMeter® 120 Series
riešenia na presné meranie
http://www.elso.sk
Three-in-one simplicity
The compact ScopeMeter 120 Series is the rugged solution for industrial troubleshooting and installation applications. It’s a truly integrated test tool, with oscilloscope, multimeter and “paperless” recorder in one affordable, easy-to-use instrument. Find answers to problems in machinery, instrumentation, control and power systems quickly and easily.
unique Connect-and-View recognizes signal patterns, and automatically sets up correct triggering. It provides a stable, reliable and repeatable display of virtually any signal - including motordrive and control signals - without touching a button. Signal changes are instantly recognized and settings adjusted for - once again - a stable display.
Fluke 125
Fluke 124
Fluke 123
True RMS
Included Accessories
PM 8907 line adapter/charger, STL120-III shielded test leads set (1 red, 1 grey) including hook clips, BB120 shielded BNC adapter, BP120MH NiMH battery pack, VPS40-III wide bandwidth Voltage Probe (Fluke 124/125), TL175 Safe-guard testlead, i400s current clamp (Fluke 125), Getting Started booklet, user’s manual (cd-rom)
• Dual-input 40 MHz or 20 MHz digital oscilloscope
• Two 5,000 counts true-RMS digital multimeters
• A dual-input TrendPlot™ recorder
• Bus Health Test for industrial bus systems (Fluke 125)
• Connect-and-View™ trigger simplicity for hands-off operation
• Power Measurements and Harmonics measurement (Fluke 125)
• Shielded test leads for oscilloscope, resistance and continuity measurements
• Up to 7 hours battery operation
• 600 V CAT III safety certied
• Optically isolated interface for PC and Printer connection (optional)
• Rugged, compact case
Connect-and-View™ triggering for an instant, stable display
Scope users know how difcult triggering can be. Wrong settings show unstable and sometimes wrong results. Fluke’s
Use TrendPlot™ to help find intermittents fast
The toughest faults to nd are those that happen only once in a while: intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. You may not be around to see it – your Fluke ScopeMeter will. In this “paperless recorder” mode, you can plot the minimum and maximum peak values and average over time – up to 22 days (Fluke 190 Series) or 16 days (Fluke 120 Series).
Bus Health mode (Fluke 125)
Bus Health mode gives a clear “Good/ Bad” indication for the electrical signals on industrial buses and networks, such as CAN-bus, Pro-bus, RS-232 and many more. The Fluke 125 validates the quality of the electrical signals as soon as any electrical signals are passed along the network.
Ordering Information
Fluke 123 Industrial ScopeMeter® (20MHz) Fluke 123/S Industrial ScopeMeter® (20MHz) + SCC120 kit Fluke 124 Industrial ScopeMeter® (40MHz) Fluke 124/S Industrial ScopeMeter® (40MHz) + SCC120 kit Fluke 125 Industrial ScopeMeter (40 MHz) Fluke 125/S Industrial ScopeMeter (40 MHz) + SCC120 kit SCC120 FlukeView® Software + OC4USB Cable + Carrying Case OC4USB USB Interface Cable PM9080 RS-232 Interface Cable DP120 Differential Voltage Probe ITP120 Isolated Trigger Probe
84
SW90W FlukeView Software BHT190 Set of 3 break-out adapters (Fluke 125)
Connect-and-View captures even the most complex motor drive signals.
See page 85 for specifications.
SCC120
C125
See page 124
Bus Health mode allows for an analysis of the signal quality on an industrial network.
Recommended Accessories
DP120
See page 86
OC4USB
See page 86
SCC128
See page 125
Page 87
ScopeMeterTest Tools
riešenia na presné meranie
http://www.elso.sk
Included Accessories
BHT190 Set of three break-out adapters for industrial networks BC190 Mains adapter/Battery charger BP190 NiMH battery pack (installed) VPS210 Voltage probe sets (1 red, 1 grey) TL175 SafeGuard(r) Testlead set C190 Hard shell protective carrying case OC4USB Optically insulated USB interface cable for PC connectivity SW90W FlukeView software package (full version)
Fluke 225C/S Industrial Networks and Bus Health Test
Built on the Fluke 190C-series, the 225C/S makes Bus Health Test analysis on the electrical signals on an industrial bus or network, giving a clear “Good”, “Weak” or “Bad” validation of the relevant parameters, presented next to the actual measurement value. The Fluke 225C/S can make the signal quality validation as soon as electrical signals are passed along the network, without looking at the data content. It nds errors like improper cable connections, bad contacts, incorrect grounding and missing or superuous terminators.
Ordering Information
225C/S Color ScopeMeter (200 MHz,
2.5 GS/s) with Bus Health Test capabilities and SCC-kit.
Typical status overview of a bushealth measurement.
General ScopeMeter
Specifications
Oscilloscope Specifications
Bandwidth 500 MHz 200 MHz 100 MHz 60 MHz 200 MHz 40 MHz 20 MHz Max. real time sample rate 5 GS/s 2.5 GS/s 1.25 GS/s 625 MS/s 2.5 GS/s 25 MS/s Input sensitivity 2 mV/div. 5 mV/div. Max. timebase speed 1 ns/div. 2 ns/div. 4 ns/div. 10 ns/div. 5 ns/div. 10 ns/div. 20 ns/div. Inputs and digitizers 2 + Ext.Tr. 4 2 + Ext.Tr. 4 2 + Ext.Tr. 2 + Ext.Tr. 2 + Ext.Tr. 2 (+ Ext.Trig. Optional) Independently floating isolated inputs 600 V
Max.record length …. In Scope mode …. In ScopeRecord mode
Glitch capture 8 ns peak detect at full timebase range 50 ns 40 ns True RMS multimeter built-in (5000 counts) yes - yes - yes dual 5000 counts DMM Dedicated test capabilities V/Hz ratio - V/Hz ratio - V/Hz ratio Bus health test -
General Specifications
Mains adapter/battery charger incl. (type) BC 190 PM8907 Battery installed BP291 BP291 BP290 BP291 BP290 BP290 BP190 BP120MH Size 265 x 190 x70 mm ** 232 x 115 x 50 mm Weight 2.1 kg 2.2 kg 2.1 kg 2.2 kg 2.1 kg 2 kg 1.2 kg Safety certified 1000 V CAT III / 600 V CAT IV 600 V CAT III
Model: 190-502 190-204 190-202 190-104 190-102 190-062 225C/S 125 124 123
CAT III
1000 V CAT III,
600 V CAT IV
10 000 samples per trace
30 000 min/max pairs
600 V
CAT III
3000
27500
-
512 min/max pairs per input
85
Page 88
ScopeMeter® Accessories
riešenia na presné meranie
http://www.elso.sk
VPS410-X
ScopeMeter series 190-series II 120-series
Description Voltage probe High working voltage
Colors available red, grey, blue, green bicolor (red & black) red, grey, blue, green red + grey (1 set) black red + grey (1 set) Attenuation 10:1 100:1 10:1 Bandwidth 300 MHz 150 MHz 500 MHz 12.5 MHz 40 MHz 20 MHz Length 1.2 m 1.2 m 1.2 m 1.2 m 1.2 m 1.5 m (2x) Safety Rating CAT II -- -- -- 1000 V 1000 V 1000 V Safety Rating CAT III 1000 V 1000 V* 300 V Safety Rating CAT IV 600 V 600 V* -- -- -- --
* High Working Voltage Probe is specied for working voltages (between probe tip and reference lead) up to 2000V in CAT III or 1200V in CAT IV environments. Reference lead voltage (between reference lead and earth ground): 1000V in CAT III, 600V in CAT IV. These specication applies only when used with Fluke 190-series II Test Tool.
PM9091/9092
VPS420-R
VPS410-x VPS420-R VPS510-x STL120-III VPS40-III DP120
probe*
PM9081
VPS510-x
Wide bandwidth
voltage probe
PM9082
STL120-III
Shielded Test leads Voltage probe Differential Voltage
1:1
600 V
10:1 200:1 / 20:1
600 V 600 V
PM9093
VPS40-III
Probe
DP120
Description Safety designed 50  BNC Cable set
Length 1.5 m each 0.5 m each -- -- -­Safety Rating CAT III 300 V 600 V 600 V
RS400
PM9091 PM9092 PM9081 PM9082 PM9093
(1 red, 1 black, 1 grey)
AS400
BP291
Dual banana plug
(m) to female BNC
Dual banana jack
(f) to BNC plug (m)
OC4USB
600 V
BNC (m) to dual BNC (f) ‘T-piece’
EBC290
RS400 Probe Accessory Replacement set for VPS200 and VPS400 series probes AS400 Accessory Extension set for VPS200 and VPS400 series probes PM9080 RS232 interface cable for 120-series OC4USB Optocoupler to USB interface cable for 120 series BP120MH Ni-MH battery pack for Fluke 120-series and Fluke 43B BP290 Single capacity Li-ion battery pack for 190-series II BP291 Double capacity Li-ion battery pack for 190-series II EBC290 External battery charger for BP290 and BP291 TRM50 Coaxial 50  feedthrough terminator RS500 Probe Accessory Replacement set for VPS510 series probes C437-II Hard shell protective carrying case with rollers for 190-II and 430-II RF-AM90 RF Detector and Demodulation probe
10:1
86
Page 89
Power Quality Tools and Power
riešenia na presné meranie
http://www.elso.sk
Analyzers
We offer an extensive range of power quality test tools for troubleshooting, predictive maintenance and long-term recording in industrial and utility applications. For the development and test of electrical equipment, our high-precision power analyzers enable easy and reliable use in the eld or as a bench unit in test laboratories. Additionally, the Fluke-patented energy loss algorithm, Unied Power Measurement, measures and quanties energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy waste within a system.
87
Page 90
Power Quality Selection Guide
riešenia na presné meranie
http://www.elso.sk
OO
(not 1743)
OOOOO
OOOOO
OOOOOOO
OOOOOOO
OOOOOOO
OOOOOOO
OOOOOOO
OOOOOOO
Single phase Three phase
OOOOOOOO
VR1710 345 43B 430 II 1735 1740 1750 1760
OOOOOOOO
OOO OOO
OOOOOO
OO
(no DC) (not 1743)
O
OOO
OOO OO
OOOOOOO
OOO OO
OOO
OOO OOO
OOOO OO
OOO OO
OOOOOOO
O OOOOOO
OOOO OO
O OOO
OOO OO
O O OOO
OOO
O OOO
(only 437-II)
O
O OOO
OO
OO OO
Detailed RMS trending shows how connected loads
behave.
Power quality tools help pinpoint problems fast
Basic measurements Application use
RMS Current
RMS voltage
88
Get detailed power and energy consumption
profiles during energy audits and pinpoint savings
opportunities.
Energy studies
Measure V, I, kW, Cos/DPF, kWhr
Measure MIN/MAX and AVG values
10 day logg ing
Energy aggregation
Utility meter pulse inputOEnergy Loss (Eff. kW, Reactive kVAR, Unbalance kVAR,
Discover the source of distortion in your installation, so
that you can filter those loads or move them to separate
circuits.
Distor tion kVAR, Neutral kVAR)
Energy loss calculatorOBasic harmonics study
THD measurement (V & I)
Harmonics 1 to 25 for V & I
Tabular values
If distorting loads are causing problems in your
installation, you need comprehensive data to intentify
the source and create a solution.
Neutral current measurement
Crest factor
Advanced harmonics study
Full harmonic spectrum
Power harmonics
Harmonics 1 to 50 and dc
k-fa ctor
%Fundamental and %RMS
Basic Industrial PQ Troubleshoot ing
When troubleshooting in the field, graphical data
enables you to trace the source of the problem at hand.
Oscilloscope function
Voltage dips and swells
Phasor diagram
Trend record ing
Complex installations often require a deeper dive into
measurement data. Multiple loads may be interacting
randomly to cause a single problem.
Inrush current
Advanced industrial PQ troubleshooting
Comprehensive logging capability
Transient capture
Flicker
EN50160 analysis
Complex System interaction event capture (manual
threshold setting)ORandom /variable system event capture (Adapt ive
threshold setting)O400 Hz
Before you install sensitive loads, make sure you
understand the existing quality of power delivered by
Utility PQ benchmarking
Phase sequence components
Interharmonics
your utility. Comparing benchmarks over time can help
pinpoint potential areas of concern.
To make use of the power data you collect, you need
software that can help analyze your findings and share
Mains signaling
IEC61000-4 -30 Class A
Software
Power Log
PQ LogOPower AnalyzeOPQ AnalyzeOFlukeView FormsOFSD card (max 32 GB) 8 GB 8 GB
them with equipment providers and plant management.
Page 91
Power Quality Clamp Meter
riešenia na presné meranie
http://www.elso.sk
Fluke 345
View waveforms for equipment checking and setup
Log parameters over time to track down intermittent faults
345
The ideal troubleshooting tool for modern electrical loads
The Fluke 345 measures a wide range of electrical parameters for troubleshooting power disturbances in single- and three-phase electrical loads. With a bright color display to see waveforms and trends, a low-pass lter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 is ideal for measurements on switching loads such as variable speed drives, electronic lighting and UPS systems.
Specifications
Current measurement
DC, DC rms, AC rms All measurements DC and 15 Hz to 1 kHz.
Measuring range 0 – 2000 A dc or 1400 AC rms Harmonics All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequency
Voltage measurement
DC, DC rms, AC rms All measurements DC and 15 Hz to 1 kHz. Maximum overload 1,000 V rms. Volts rms is a
Measuring range 0 – 825 V DC or AC rms Harmonics All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hz
Watts measurement (single- and three-phase)
Measuring range 0 – 1650 kW DC or 1200 kW ac
VA measurement (single- and three-phase)
Measuring range 0 -1650 kVA DC or 1200 kVA ac
VAR measurement (single- and three-phase)
Measuring range 0 – 1250 kVAR
Power factor (single- and three-phase)
Measuring range 0.3 cap…1.0… 0.3 ind (72.5° cap…0°… 72.5° ind)
Displacement power factor
Measuring range 0.3 cap … 1.0 … 0.3 ind (72.5° cap ... 0° ... 72.5° ind)
Kilowatt Hour (kWHr)
Measuring range 40,000 kWHr
Scope function
Time base 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div Current management: Ranges 10 A/20 A/40 A/100 A; 200 A/400 A/1000 A/2000 A Voltage measurement: Ranges 4 V/10 V/20 V/40 V/100 V; 200 V/400 V/1000 V
Inrush current function
Ranges 40, 400 and 2000 A
Memory
Power supply: 1.5 V Alkaline AA MN 1500 or IEC LR6
x 6 Batter y Battery life (typical): >10 hours ( backlight on full); >12 hours (backlight reduced) Safety: IEC 61010 -1 600 V CAT IV, 1000V CAT III (maximum input phase-phase 825V rms) double or reinforced insulation, pollution degree 2
Protection: IP40; EN60529 Operating temperature: 0 °C to 50 °C
Maximum overload 10,000 A or RMS x frequency < 400,000. Amps rms is a true rms measurement (AC + DC).
range F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A
true-rms measurement (AC + DC).
to 65 Hz; Vacrms > 1V
DC, DC rms, AC rms
DC, DC rms, AC rms
All measurements dc and 15 Hz to 1 kHz
Up to 50 screen shots and over 150,000 individual measurement values
High safety rating: 600V CAT IV / 1000V CAT III rated for use at the service entrance
ac/dc current measurements: Clamp- on measurement of ac peak and dc current up to 2000 A without breaking the circuit
Harmonic analysis: Analyze, display and log harmonics up to the 30th harmonic (40th harmonic for 15 Hz to 22 Hz)
Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
(Check the Fluke web for detailed specifications)
Display: Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level back light
Digital output: USB interface to a PC Size (HxWxD): 300 mm x 98 mm x 52 mm Jaw opening: 60 mm Jaw capacit y: 58 mm diameter Weight (including batteries): 0.82 kg Two Year Warrant y
Included Accessories
Soft carrying case, Power Log software, Test probes, Test leads, Alligator clips, International ac adapter / battery eliminator, Printed English User manual, Multi-language manual on CD
Ordering Information
Fluke 345 Power Quality Clamp Meter
TLK291
See page 123
TP220-1
See page 123
Recommended Accessories
AC220
See page 124
TP1-1
See page 123
C550
See page 130
89
Page 92
43B Single-phase Power
riešenia na presné meranie
http://www.elso.sk
Quality Analyzer
The perfect tool for tracking down single-phase power-related problems
The Fluke 43B is the choice for diagnosing and troubleshooting power quality and general equipment failures. Ease to use thanks to menu selection of the power modes, it combines the
capabilities of a power quality analyzer, a 20 MHz oscilloscope, a multimeter and a data recorder in a single instrument.
Fluke 43B
On all inputs
True RMS
Included Accessories
TL224 test lead set, AC220 alligator clip set, TP4 test probe set, BP120MH rechargeable battery pack, BB120 shielded BNC adapter, PM8907 line adapter/charger, i400s AC current clamp, AB200 alligator clip set, TP1-1 test probe set, C120 hand carrying case, OC4USB interface cable, SW43W FlukeView software, VPS 40 voltage probe, Fluke 61 IR thermometer, user and application manual.
• Voltage, current, and power harmonics
• Up to 51st harmonic
• Total harmonic distortion (THD)
• Phase angle of individual harmonics
• Watts, power factor,
ƴ, VA and VAR
COS
• Voltage and current waveforms
• Continuously measure volts and amps on a cycle-by-cycle basis for up to 16 days
• Use cursors to read time and date of sags and swells
• Connect-and-View™ scope for quick waveform display
• View voltage and current channels simultaneously
Specifications
(Check the Fluke web for detailed specifications)
Menu items Measurements Ranges Accuracy
Volts/Amps/Hz Volts
Power Watts, VAR, VA
Harmonics Volts
Sags & Swells Voltage and Current 4 min-16 days selectable ±(2%+10) Transient Capture 40 ns pulse width
Inrush Current 1 sec. to 5 min selectable 1 A to 1000 A ± 5% of full scale Ohms/Continuity/
Capacitance Temperature (with accessory) Scope DC, AC, AC+DC, peak,
Screen saves All functions 20 screens Recording V/A/Hz, Power, Harmonics,
Amps Mains frequency CF Crest Factor
ƴ
PF, DPF, COS
Amps Watts K-factor
Up to 40 transients
Ohms Capacitance ºC ºF
peak-peak, Hz, duty cycle, phase, pulse width, crest factor
Ω/Cap, Temperature, Scope
Battery life: Rechargeable Ni-MH pack (charger included), 6 hrs typical (continuous) Shock & Vibration: Mil 28800E, Type 3, Class III, Style B. Operating temperature: 0°C to 50°C; Case: IP51 (dust, drip, waterproof) Size (HxWxD): 232 mm x 115 mm x 50 mm; Weight: 1.1 kg Three Years Warranty
5.000 V - 1250 V
50.00A - 50.00 kA
40.0 - 70.0 Hz 1,0 à 10,0 250 W - 1.56 GW
0.25 W-0.9
0.90-1.00 1 st to 51 st harmonic 1 st to 51 st 1 st to 51 st
1.0 to 30.0
Select 20/50/100/200% above or below line voltage
500.0  to 30.00 M
50.00 nF to 500.0 µF
-100.0ºC to 400.0ºC
-200.0ºF to 800.0ºF Sampling rate: Bandwidth: Voltage BW (Channel 1) Current BW (Channel 2)
4 min - 16 days selectable Select any two parameters
±(1%+10) ±(1%+10) ±(0.5%+2) ±(5%+1) ±(4%+4) ±0.04 ±0.03 ±(3%+2) to ±(15%+5) ±(3%+8) to ±(15%+5) ±(5%+2) to ±(30%+5) ±10%
± 5% of full scale
± (0.6%+5) ± (2%+10) ± (0.5%+5)
25 MS/sec
20 MHz 15 kHz
display mode in each
Ordening information
Fluke 43B Power Quality Analyzer (single-phase)
90
Recommended Accessories
i2000flex
See page 126
i1000s
See page 126
80TK
See page 128
Page 93
VR1710 Single-Phase Voltage
riešenia na presné meranie
http://www.elso.sk
Quality Recorder
Easy-to-use solution for detecting and recording voltage quality problems
The Fluke VR1710 is a single-phase, plug­in voltage quality recorder that provides fast and easy recording of voltage trends, dropouts, harmonics and general power quality including dips and surges to help maintenance and facilities management personnel easily pinpoint the root cause of voltage problems. Voltage quality parameters including RMS average, transients, icker, and harmonics up to
Fluke VR1710
Fluke VR1710 and included accessories
the 32nd are recorded using a user­selected average period from 1 second to 20 minutes.
Applications
Voltage recording – Monitors and records supply voltage; measures RMS average, minimum and maximum values, and checks whether the socket outlet is providing voltage within tolerance.
Distortion measurement – Measure frequency and harmonics; check whether the distorting loads (UPS systems, drives, etc.) are affecting your other equipment.
• Clear graphical summary of data and quick overview of key power quality parameters
• Get the complete picture with Min, Max, Average RMS values (1/4 cycle) with time stamps
• See the detailed with actual transient display (> 100 µs) with time stamp
• Comprehensive analysis of Individual harmonic and THD values with trends
Flicker measurement – Quantify the affects of switching loads on lighting systems.
Voltage transients – Capture those intermittent, momentary events that may be affecting your equipment; the full waveform is captured with date, timestamp, and duration.
Includes PowerLog software
Included Accessories
Plug-in Fluke VR1710, USB cable, PowerLog software CD, universal power cord adapters.
Ordering Information
Fluke VR1710 Voltage Quality Recorder
PowerLog Setup – Simple set up of internal clock, logging periods, and intervals with default values for quick results. PowerLog View – Data presentation showing RMS voltage and harmonic trends, actual transients, summary information and statistics in accordance with EN50160.
Actual transient display (> 100 μs) with time stamp–
Quickly identify issues with included graphical software.
Statistical analysis of voltage event – reduces analysis time by tracking
event quantities and magnitudes.
Specifications
(Check the Fluke web for detailed specifications)
Operating voltage 70 V to 300 V Min/Max/Avg RMS value Resolution 0.125 V Number of events 175,000 Dips/Interruptions Yes Time resolution 5 ms Voltage resolution) 0.125 V Over-voltages Yes Frequency Yes Harmonics measurement EN 61000-4-7 (up to 32nd) Flicker measurement EN 61000-4-15 Number of recording channels 1 Phase to Neutral
Recording time 1 day to 339 days depending on average time from 1 second to 20 minutes Transients Yes (> 100µs) Frequency range 50 Hz ± 1 Hz and 60 Hz ± 1 Hz Safety category rating CAT II 300 V
Display: LED Size (HxWxD): 23 x 19.75 x 22.2 cm
2 Phase/Neutral to Ground
Weig ht: 0.8 kg Two years warrant y
91
Page 94
430 Series II Three-Phase Power
riešenia na presné meranie
http://www.elso.sk
Quality and Energy Analyzers
New
Fluke 437-II
Fluke 435-II Fluke 434-II
Compliant
Fluke
435 II / 437 II
True RMS
On all inputs
More detailed power quality analysis capability, and a Fluke-patented energy monetization function
The new Fluke 434, 435 and 437 Series II models help locate, predict, prevent, and troubleshoot power quality problems in three-phase and single­phase power distribution systems. Additionally, the Fluke-patented energy loss algorithm, Unied Power Measurement, measures and quanties energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy waste within a system.
• Energy loss calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantied to pinpoint true system energy losses in dollars.
• Power inverter efciency: Simultaneously measure AC output power and DC input power for power electronics systems using optional DC clamp.
• PowerWave data capture: 435 and 437 Series II analyzers capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
• Waveform capture: 435 and 437 Series II models capture 100/120 cycles (50/60Hz) of each event that is detected in all modes, without set-up.
• Automatic Transient Mode: 435 and 437 Series II analyzers capture 200 kHz waveform data on all phases simultaneously up to 6 kV.
• Fully Class-A compliant: 435 and 437 Series II analyzer conduct tests according to the stringent international IEC 61000-4-30 Class-A standard with 435 and 437 Series II analyzers.
• 400 Hz measurement: 437 Series II analyzer captures power quality measurements for avionic and military power systems.
• Troubleshoot real-time: Analyze the trends using the cursors and zoom tools.
• Highest safety rating in the industry: 600 V CAT IV/ 1000 V CAT III rated for use at the service entrance.
• Automatic Trending: Every measurement is always automatically recorded, without any set-up.
• System-Monitor: Ten power quality parameters on one screen according to EN50160 power quality standard
• Logger function: Congure for any test condition with memory for up to 600 parameters at user dened intervals.
Unified Power Measurement
Fluke’s patented Unied Power Measurement system (UPM) provides the most comprehensive view of power available, measuring:
• Parameters of Classical Power (Steinmetz 1897) and IEEE 1459-2000 Power
• Detailed Loss Analysis
• Unbalance Analysis
• These UPM calculations are used to quantify in dollars the cost of energy loss caused by power quality issues.
Energy savings
The cost of power quality could only be quantied in terms of downtime caused by lost production and damage to electrical equipment. The Unied Power Measurement (UPM) method now goes beyond this to achieve energy savings by discovering the energy waste caused by power quality issues. Using the Unied Power Measurement, Fluke’s Energy Loss Calculator will determine how much money as facility is losing due to waste energy.
Unbalance
UPM gives a more comprehensive breakdown of the energy consumed in the plant. In addition to measuring reactive power (caused by poor power factor), UPM also measures the energy waste caused by unbalance; the effect of unevenly loading each phase in three-phase systems.
Harmonics
UPM also provides details of the energy wasted in your facility due to the presence of harmonics. The presence of harmonics in your facility can lead to:
• Overheating transformers and conductors
• Nuisance tripping of circuit breakers
• Early failures of electrical equipment
Phasor diagram.
92
Track harmonics up to the 50th, and measure and record THD in accordance with IEC61000-4-7 requirements.
The System-Monitor overview gives instant insight into whether the voltage, harmonics, flicker, frequency and the number of dips and swells fall outside the set limits. A detailed list is given of all events falling outside the set limits.
Page 95
430 Series II Three-Phase Power
riešenia na presné meranie
http://www.elso.sk
Quality and Energy Analyzers
Energy Loss Calculator
Useful k ilowatts (power) available
Kilowatts made unusable by harmonics
Kilowatts made unusable by unbalance issues
Total bil lable kilowatt hours wasted
Total cost of wasted ki lowatt hours
Fluke 437 II with all standard accessories.
Included Accessories
TL430 test lead and alligator clip set, i430ex-TF, 61 cm, 4 clamps, BC430 power adapter, BP290 single capacity Li-ion battery, International plug adapter set, WC100 color coding clips and regional decals, 8 GB SD card, PowerLog on CD USB cable A-Bmini C1740 softcase (434-II, 435-II), C437 hard case (437-II)
Ordering information
Fluke 434-II Three-Phase Energy Analyzer Fluke 435-II Three-Phase Power Quality and Energy Analyzer Fluke 437-II Three-Phase Power Quality and Energy Analyzer
Logging provides instantaneous analysis of user selectable parameters.
Input characteristics
Voltage inputs Number of inputs 4 (3 phase + neutral) dc-coupled Maximum input voltage 1000 Vrms Nominal volt age range Selectabl e 1 V to 1000 V Max. peak me asurement voltage 6 kV (trans ient mode only) Input impedance 4 M//5 pF Bandwidth > 10 kH z, up to 100 kHz for tr ansient mode Scaling 1:1, 10:1, 10 0:1, 1,000:1 10,00 0:1 and variable Current inputs Number of input s 4 (3 phase + n eutral) dc- or ac-coupl ed Type Clamp or current tra nsformer with mV output or i430flex-TF Range 0.5 Arms to 60 0 Arms with i ncluded i430fl ex-TF (w ith sensitivit y 10x)
Input impedance 1 M Bandwidth > 10 kH z Scaling 1:1, 10:1, 10 0:1, 1,000:1 10,00 0:1 and variable Measurement modes Scope 4 voltage wavefor ms, 4 current wav eforms, Vrms, Vfu nd. Arms, A fund , V @ cursor,
Volts/amps/hertz Dips and swells Vrm s½, Arms½, Pinst w ith program mable threshold lev els for event detecti on Harmonic s dc, 1 to 50, up to 9th harm onic
for 400 Hz
Power and ener gy Vrms, Ar ms, Wfull, Wfu nd., VAfull, VAfund., VAha rmonics, VAunbalanc e, var, PF, DPF, Co sQ,
Energy loss calculator Wfund , VAh armonics, VAunbala nce, var, A, Loss Ac tive, Loss React ive, Loss Harm onics, Loss
Inverter efficiency (requires optional dc current clamp)
Unbalance Vneg%, Vzero%, Ane g%, Azero%, Vf und, Afund, V phas e angles, A phase ang les Inrush Inrush c urrent, Inru sh duration, Arm s½, Vrms½ Monitor Vrms, A rms, harmonic Volts , THD Volts, PLT, Vrms½, Arms½, H z, dips, swells, int erruptions, r apid
Flicker (4 35-II and 437-II only) Pst(1min), Pst, Plt, Pinst, Vrms ½, Arms ½, Hz Transient s (435-II and 437-II only) Transient wa veforms 4x Voltage 4x Amp s, triggers: Vr ms ½, Arms ½, Pi nst Mains Signa ling
(435-II and 4 37-II onl y)
UPower Wave (435-II and 4 37-II onl y)
Logger Custo m selection of up to 150 P Q parameters mea sured simultane ously on 4 phases
Battery life: 7 hours operating time per charge on Li-ion batter y pack Safety: EN61010-1 (2nd edition) pollution deg ree 2; 100 0 V CAT III / 600 V CAT IV Case: Rugged, shock proof with integ rated protective holster, IP51 (dr ip and dust proof) Shock: 30 g; Vibration: 3g according to MIL-PR F-28800F Class 2 Operating temperature: 0°C to +50°C Size (HxWxD): 265 mm x 190 mm x 70 mm; Weight: 2.1 kg Three Years War ranty
5 Arms to 6 000 Arms w ith included i430f lex-TF (with sensit ivity 1x)
0.1 mV/A to 1 V/A and cu stom for use with opt ional ac or dc clamps
A @ cursor, pha se angles
Vrms phas e to phase, Vrms phase t o neutral, Vpeak, V C rest Factor, Arms Ap eak, A Crest Factor, Hz
Harmon ics Volts, THD, Harmon ic Amps, K factor Amp s, Harmonic Watts , THd Watts, K factor Watts, Interh armonic Volts, Interh armonic Amps, Vr ms, Arms (relati ve to fundamental o r to total rms)
Efficiency fact or, Wforw ard, Wreverse
Unbalance , Loss Neutral, Lo ss Cost (based up on user defined cos t / kWh) Wfull, Wf und, Wdc, Efficien cy, Vdc, A dc, Vrms, Arms, H z
voltage cha nges, unbalance a nd mains signal ling. All param eters are measure d simultaneously in accorda nce with EN50160 Fl agging is applie d according to IEC610 00-4-30 to i ndicate unrelia ble reading s due to dips or swells
Relative s ignaling voltag e and absolute signal ing voltage average d over three second s for up to two selectable signal ing frequencies
Vrms½, Ar ms½ W, Hz and scope waveform s for voltage amps and wat ts
Recommended Accessories
i430-FLEXI-TF-4PK
See page 98
i5sPQ3
See page 98
BP291
See page 86
See page 98 for power quality current clamps
93
Page 96
Fluke 1735
riešenia na presné meranie
http://www.elso.sk
1735 Power Logger
Performs electrical load studies, energy consumption testing, and general power quality logging
The Fluke 1735 Power Logger is the ideal tool for electricians and maintenance technicians for conducting energy studies and basic power quality logging. The 1735 is easy to set up with its color display and four included new thinner exible current probes.
The 1735 logs most electrical power parameters, harmonics and captures voltage events. View graphs and generate reports with the included Fluke Power Log software.
• Record power and associated parameters for up to 45 days
• Monitor maximum power demand over user-dened averaging periods
• Prove the benet of efciency improvements with energy consumption tests
• Measure harmonic distortion caused by electronic loads
• Improve reliability by capturing voltage dips and swells from load switching
• Conrm instrument setup easily with color display of waveforms and trends
View recorded data in simple graphs and tables with Fluke Power Log software.
Customize the report generator to easily generate professional looking reports.
Included Accessories
FS17X5-TF 4-phase flexible current clamp set, VL1735/1745 voltage lead set, Power Log software, color localization set, PC interface cable, international ac adapter, BC1735 battery charger, soft carrying case, printed English manual and multi-language manual on CD.
Conduct load studies for up to 45 days and view saved data on-screen or on a computer.
Quantify energy consumption quickly on-screen or log to memory for extended periods.
Access voltage and current harmonics up to the 50th.
Capture voltage events using user-defined thresholds.
Specifications
(Check the Fluke web for detailed specifications)
Volts rms V-rms wye measurement ranges:
Amps rms Flexi set measurement range: 15 A/150 A/3000 A rms (at sine)
Frequency Measurement range: 46 Hz to 54 Hz and 56 Hz to 64 Hz Harmonics and THD To 50th harmonic (< 50 % of nom) Power measurement
(P - Active, S - Apparent, Q - Reactive, D - Distorting) Energy Measurement (kWh, KVAh, kVARh) Measuring range: see V-rms and A-rms measurement rangeso PF (Power factor) 0.000 to 1.000 Events Detection of voltage dips, voltage swells and voltage interruptions with a
General
Memory 4 MB Flash memory, 3.5 MB for measuring data Sample rate 10.24 kHz Line frequency 50 Hz or 60 Hz, user-selectable, with automatic synchronization
Display: VGA Graphic Color transmissive displays 320 x 240 pixels with additional background lighting and adjustable contrast, text and graphics in color Interface: USB with Mini USB B socket. Firmware updates are possible with the USB interface Housing: IP65; EN60529 (refers only to the main housing w ithout the battery compartment)
57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/ 400 V/417 V/480 V AC V-rms delta measurement ranges: 100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/ 690 V/720 V/830 V AC
Current clamp measurement range: 1 A/10 A
Measuring range: see V-rms and A-rms measurement ranges
10 ms resolution and measuring error of the half period sine wave of rms.
Power supply: NiMH batter y-pack, with AC adapter (15 V to 20 V/0.8 A) Battery Life: Typical > 16 hours without backlight and > 6 hours with backlight high
Operating temperature: 0°C to + 40°C Size (HxWxD): 240 mm x 180 mm x 110 mm Weig ht: 1.7 kg, including batter y Two Year Warrant y
Ordering Information
Fluke 1735 Power Logger FS17X5-TF 4-phase thin flexi current clamp set, 3000 A 3000/6000A-TF-4 4-phase thin flexi current clamp set, 6000 A
94
Recommended Accessories
See page 98 for power quality current clamps
Page 97
1740 Series Three-Phase
riešenia na presné meranie
http://www.elso.sk
Power Quality Loggers Memobox
Assess power quality and conduct long-term studies with ease
Fluke 1743
Fluke 1745
Fluke 1744
Compact, rugged and reliable, the Fluke 1740 Series three-phase power quality loggers are everyday instruments for technicians who troubleshoot and analyze power distribution systems. Capable of simultaneously logging up to 500 parameters for up to 85 days and capturing events, the Fluke 1740 Series helps uncover intermittent and hard-to­nd power quality issues. There are three models to choose from to meet your basic or advanced power logging needs.
Fluke 1743: IP65 waterproof monitor for logging the most common power parameters including V, A, W, VA, VAR, PF, energy, icker, voltage events and THD.
Fluke 1744: Includes the same features as the Fluke 1743. In addition to common power parameters, the Fluke 1744 also measures voltage and current harmonics, interharmonics, mains signaling, unbalance, and frequency.
Fluke 1745: Advanced IP50 power quality logger with the same measurement capability as the 1744, plus real-time LCD, ve hour UPS.
Plug and play: Set up in minutes with automatic current probe detection and powering
Installs inside the cabinet: Compact, fully-insulated housing and accessories t easily in tight spaces next to live power
Monitors power for the long-term: Data can be downloaded during recording without interruption
Measure voltage with premium accuracy: IEC61000-4-30 Class-A compliant voltage accuracy (0.1%)
Quickly validate quality of power: Assess power quality according to EN50160 power quality standard with statistical overview
The included PQ Log software helps you to quickly identify the root cause of a disturbance.
Included Accessories
Fluke 1743/1744/1745: FS17XX IP65-TF thin exible current clamp set (1743 & 1744), FS17X5-TF thin exible current clamp set (1745), VL1735/1745 voltage lead set (1745 only), Power Log software, RS232 interface cable and RS232-USB adapter, 4 black dolphin clips, WC17XX color localization set, carrying bag, test certicate with measurement values, printed English manual and multi-language manual on CD. Basic models: Excl. current clamps FS17XX-TF
Ordering Information
Fluke 1743 Basic Power Quality Logger Memobox Fluke 1743 Power Quality Logger Memobox Fluke 1744 Basic Power Quality Logger Memobox Fluke 1744 Power Quality Logger Memobox Fluke 1745 Power Quality Logger Memobox FS17x5-TF 4-phase thin exi current clamp set, 3000 A 3000/6000A-TF-4 4-phase thin exi current clamp set, 6000 A
Measurement of common power parameters: V, A, W, VA, VAR, PF, energy, flicker, voltage events (dips, swells, interruptions), and THD
Measurement of voltage and current harmonics to the 50th, unbalance, frequency and mains signaling
Dust/water resistance Display Memory UPS ride-through EN 50160
Power supply: 88 V … 660 V AC Safety: IEC/EN 61010-1 600 V CAT III, 300 V
CAT IV, pollution degree 2, double insulation
Housing: Fully insulated housing and accessories Operating temperature: 0 °C to 35°C Interface: RS 232, 9600 ... 115 000 Baud, automatic
Baud rate selection, 3-wire communication
See page 98 for power quality current clamps
Specifications
(Check the Fluke web for detailed specifications)
1745 1744 1743
OOO
OO
IP 50 IP 65 waterproof
LED + LCD LED LED
8 MB 8 MB 8 MB
> 5 hrs 3s 3s
OOO
Size: Fluke 1745: 282 mm x 216 mm x 74 mm; Fluke 1743/44: 170 mm x 125 mm x 55 mm Weig ht: Fluke 1745 – approx. 3 kg; Fluke 1743/44: approx. 2 kg
Two Year Warrant y
95
Page 98
1750 Three-Phase Power
riešenia na presné meranie
http://www.elso.sk
Recorder
Never miss capturing a disturbance
On all inputs
With its exclusive threshold-free measurement system, the Fluke 1750 Power Recorder captures every measurement, every event, on every cycle, all the time. Outstanding accuracy and resolution provide complete visibility into your installation or distribution system.
Power quality that meets the standard: All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, harmonics, icker etc.
Quick and reliable conguration: PDA wireless “front panel interface” provides the ability to verify setup without a laptop along with a window into what the instrument is recording, even in awkward test locations.
Threshold-free setup: Apply thresholds after data is collected with Fluke Power Analyzer Software so there is no need to worry about missed information due to incorrect set-up.
Captures everything: Cross-channel and current triggering capture every measurement, on every channel, every time.
Intuitive PC software: Easily analyze data and generate reports. Automated EN50160 reporting and compliance.
Plug and play: Set up in minutes with seldentifying current probes and single-lead voltage connections.
No need to reconnect wires: Swap channels internally with the wireless PDA or PC when connections are not correct.
• Measure every parameter: Voltage and current on three phases, neutral, and ground.
• 5 MHz, 8000 Vpk waveform capture: Get a detailed picture of even the shortest events.
• Quickly retrieve data: With included SD memory card or via the 100BaseT high­speed Ethernetv connection
View measurements real time with wireless PDA interface
Included Accessories
PDA and charger power plug adapters, 4 current probes, 5 test leads and clips, SD memory card., Fluke Power View and Fluke Power Analyze software, power cord with international plug set, Ethernet cable, color localization set, soft carrying case, Printed Getting Started manual, CD with software and users manual PDF Basic model: excl. 4 current probes
Ordering Information
Fluke 1750/B Three-Phase Basic Power Recorder Fluke 1750
Three-Phase Power Recorder
Specifications
(Check the Fluke web for detailed specifications)
Power quality measurement standards
Conformance Clock/calendar Leap years, 24-hour clock Real-time clock accuracy Not more than ± 1 s/day Internal memory capacity for data At least 1 GB Maximum recording period At least 31 days Measurement time control Automatic Maximum number of events Limited only by the size of the internal memory Power requirements 100 to 240 V rms ± 10 %, 47-63 Hz, 40 W
Operating time during interruptions (internal UPS operation) 5 minutes per interruption, 60 minutes total operating time without recharging
Safety: EN 61010-1 2nd Edition; 2000 Weig ht: 6.3 kg Size (H x W x D): 215 x 310 x 35 mm One Year Warranty
IEC 61999-1-4 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459 and EN50160
Recommended Accessories
Model Description
3210-PR-TF 1000A Thin flexible current transformer 61 cm (24") (20 A - 1000 A) 3310-PR-TF 5000A Thin flexible current transformer 61 cm (24") (100 A - 5000 A) 3312-PR-TF 5000A Thin flexible current transformer 122 cm (48") (100 A - 5000 A) 3140-PR Clamp-on current transformer (2 A - 400 A) i40S-PR Clamp-on current transformer (0,1 A - 40 A) i4S-PR Clamp-on current transformer (0,01 A - 5 A) FLUKE-1750/SEAT-L Fluke Power Analyze – Additional SEAT LICENSE FLUKE-1750/SITE-L Fluke Power Analyze – Additional SITE LICENSE FLUKE-1750/CASE Hard Case CS1750 Soft Case HP IPAQ 2490 Additional Wireless Interface PDA FLUKE-1750/MC Additional 512 MB SD Memory Card
96
Page 99
1760 Three-Phase Power
riešenia na presné meranie
http://www.elso.sk
Quality Recorder Topas
Class-A compliance for the most demanding power quality tests
Fluke 1760
The Fluke 1760 Three-Phase Power Quality Recorder is fully compliant to IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium and low-voltage networks, the Fluke 1760 provides the exibility to customize thresholds, algorithms, and measurement selections. It has 8 input channels (4 currents/4 voltages or 8 voltages), and captures the most comprehensive details on user selectable parameters.
GPS time synchronization: Correlate data with events or datasets from other instruments with precision
Uninterrupted power supply (40 minutes): Never miss important events - even record the beginning and end of interruptions and outages
10 MHz, 6000 Vpk waveform capture: Get a detailed picture of even the shortest event
2 GB data memory: Enables detailed, simultaneous recording of numerous power parameters for long periods of time
Includes Comprehensive software: Provides trend diagrams for root cause analysis, statistical summaries, report writing and real-time data monitoring in the online mode
The included PQ Analyze software provides a detailed overview of several power quality parameters on one dashboard according to the EN50160 power quality standard.
Included Accessories
4 x TPS Flex 24-TF flexible current probe, 4 x TPS VoltProbe 600V, 2 GB internal flash memory, ST1760 standard Ethernet cable, RS232 interface cable and RS232-USB adapter, CS1760 crossover Ethernet cable, 1 mains cable, PC software on CD-ROM, WC17xx color localization set, GPS-time sync (1760TR only) CS 1750/1760 carrying bag, hardware and software manual
Basic models: Excl. current clamps TPS Flex 24-TF
Ordering Information
Fluke 1760 Basic Power Quality Recorder Topas Fluke 1760TR Basic Power Quality Recorder Topas Fluke 1760 Power Quality Recorder Topas Fluke 1760TR Power Quality Recorder Topas
Features
(Check the Fluke web for detailed specifications)
Power quality statistics according to EN50160 Voltage event list (dips, swells and interruptions) Continuous recording of: Voltage Current Power P, Q, S Power factor kWh Flicker Unbalance Frequency Voltage and current harmonics to the 50th/
Interharmonics THD Mains signaling Triggered recordings Online mode (Oscilloscope, transients and events) Fast transient analysis up to 10 MHz 4 voltage probes 4 dual-range flexible current probes (1000 A / 200 A ac) GPS time sync receiver Memory 2 GB Flash memory
Power supply: 83 V to 264 V, 45 to 65 Hz Battery pack: NIMH, 7.2 V, 2.7 Ah (up to 40 minutes
back-up power supply) Safety: 600V CAT IV/1000V CAT III (Rated for use at the service entrance)
Housing: Fully insulated robust plastic housing
1760 Basic 1760TR Basic 1760 1760TR
OOOO OOOO
OOOO OOOO OOOO OOOO OOOO OOOO OOOO OOOO OOOO
OOOO OOOO OOOO OOOO
Operating temperature: 0 °C to 35°C Interfaces: Ethernet (100 MB/s), RS-232, external modem via RS-232 Size (HxWxD): 325 mm x 300 mm x 65 mm Weig ht: Approxiamtely 4.9 kg Two Year Warrant y
OO
OO OO OO
Recommended Accessories
(Check the Fluke web for complete accessory list)
Model Description
• TPS VOLTPROBE 10 V 10 V Voltage Probes (Range: 0.1 V to 17 V)
• TPS VOLTPROBE 100 V 100 V Voltage Probes (Range: 1 V to 170 V)
• TPS VOLTPROBE 400 V 400 V Voltage Probes (Range: 4 V to 680 V)
• TPS VOLTPROBE 600 V 600 V Voltage Probes (Range: 10 V to 1000 V)
• TPS VOLTPROBE 1 KV 1000 V Voltage Probes (Range: 10 V to 1700 V)
• TPS FLEX 18-TF Flexible Current Probe (Range: 1 A to 100 A / 5 A to 500 A)
• TPS FLEX 24-TF Flexible Current Probe (Range: 2 A to 200 A / 10 A to 1000 A)
• TPS FLEX 36-TF Flexible Current Probe (Range: 30 A to 3000 A / 60 A to 6000 A)
• TPS CLAMP 10 A / 1 A Clip-on Current Transformer (Range: 0.01 A to 1 A / 0.1 A to 10 A)
• TPS CLAMP 50 A / 5A Clip-on Current Transformer (Range: 0.05 A to 5 A / 0.5 A to 50 A)
• TPS CLAMP 200 A / 20 A Clip-on Current Transformer (Range: 0.2 A to 20 A / 2 A to 200 A)
• TPS SHUNT 20 MA 20 mA ac/dc Shunt (Range: 0 to 55 mA)
• TPS SHUNT 5 A 5 A ac/dc Shunt (Range: 0 to 10 A)
97
Page 100
Power Quality Current Clamps
riešenia na presné meranie
http://www.elso.sk
i5sPQ3
i430-FLEXI-TF-4PK
clamp
Current
3 ... phase 5A
3000A
Flexible
4 ... phase
clamp
Single phase
400A current
3000A
Flexible
4 ... phase
IP65
4 Phase
flexiset,
IP41
4 Phase
flexiset,
flexiset
4 Phase
3000/6000A-TF-4 FS17X5-TF FS17xx IP65-TF i3000 flex ... 4PK i400s
set
current
clamp set
(4 required)
current
clamp set
MBX
Lem Flex
(15/150/3000)
MBX
Lem Flex
(15/150/3000)
kHz
0.01 A ... 6 A
3000 A
3000 A 5 A
30 A ...
40 A
400 A
5 A ... 400 A
0.5 A ... 40 A
OOOO
30 A
300 A
3000 A
1 A ... 30 A
1 A ... 300 A
1 A ... 2400 A
(EP0404A)
(EP0404A)
AC
15A 150A
1500A 3000A
AC
15A 150A
1500A 3000A
AC
30A 300A
3000A 6000A
450mA …
150A 6A…
1500A 12A…
15A 600mA…
450mA …
150A 6A…
1500A 12A…
15A 600mA…
AC
0.8 ... 6.000 A
3000A
3000A
40 Hz ... 5
kHz
10 Hz ... 7
kHz
45 Hz ... 3
O
kHz
2% + 2 A 2% + 0.15 A 1% 1%
influence
2%+2% position
influence
40Hz …5kHz 40Hz …5kHz 10 Hz ... 100
2%+2% position
opening:
61 cm Clamp
opening:
15 mm
400 mV/A
@50 Hz
0.085 mV/A
32 mm
1 mV/A
10 mV/A
1 mV/A
CAT III 600 V
CAT III 1000 V
0.1 mV/A CAT III 600 V CAT III 1000 V
CAT III 1000 V
CAT III 1000 V
CAT IV 600 V
CAT IV 600 V
4 x BNC 4 x BNC 4 x BNC 3 x BNC
One
CAT IV 600V
One
CAT IV 600V
One
CAT IV 600V
O
connector
connector
connector
i20A/200A
CLAMP PQ4
i20A/200A
CLAMP PQ3
i5A/50A
CLAMP PQ4
i5A/50A
CLAMP PQ3
i1A/10A
CLAMP PQ4
i1A/10A
CLAMP PQ3
clamp set
4 ... phase
20A/2000A
Mini current
20A/200A
clamp set
3 ... phase
Mini current
current
clamp set
4 ... phase
5A/50A Mini
current
clamp set
3 ... phase
5A/50A Mini
current
clamp set
4 ... phase
1A/10A Mini
current
clamp set
1A/10A Mini
0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
1)
kHz
40 Hz ... 10
kHz
40 Hz ... 10
kHz
40 Hz ... 10
kHz
40 Hz ... 10
kHz
40 Hz ... 10
kHz
20 A
20 A
(EPO456A)
20/2000A+N
MBX CLAMP
20A/200A
(EPO455A)
MBX CLAMP
5A/50A+N
(EPO453A)
MBX CLAMP
5A/50A
(EPO452A)
MBX CLAMP
1A/10A+N
(EPO451A)
MBX CLAMP
OOOOOOOOO
(EPO450A)
CLAMPS 1A
200 A AC
200 mA ...
2 A ... 200 A
20 A
20 A
200 A AC
200 mA ...
2 A ... 200 A
5 A
5 A
1 A
OOOOOOOOO
50 A
50 A AC
500 mA ...
50 mA ... 5A
50 A
50 A AC
500 mA ...
50 mA ... 5 A
10 A
10 A AC
100 mA ...
10 mA ... 1 A
10 A
10 A AC
100 mA ...
One
connector
One
connector
One
connector
One
connector
One
connector
connector
i400s i430-FLEXI-TF-4PK i5sPQ3
i3000 flex-4PK
(4x i3000s flex24)
Fluke model number
Description 3 ... phase
98
Old Fluke model # CURRENT
Fluke 1735
Fluke 174X
Fluke 43X
Basic accuracy (48 ... 65 Hz)
Lowest measurable current 10 mA 10 mA 50 mA 50 mA 200 mA 200 mA 450 mA 450 mA 1 A 0.5 A 30 A 10 mA
Cont. AC current range 10 mA ... 1 A
Nominal current range(s) 1 A
Highest current 20 A 20 A 100 A 100 A 300 A 300 A 0.8 A 3300 A 3300 A 4000 A 1000 A 100 kA 70 A
Usable frequency 40 Hz ... 10
Requires battery
Flex head length 92 cm 61 cm 61 cm Clamp
Output level(s) 75 mV/A 75 mV/A 15 mV/A 15 mV/A 3.75 mV/A 3.75 mV/A 0.1 mV/A 0.1 mV/A 10 mV/A
Connection One
Safety rating CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 1000 V
Output cable (m) 2 222224222.12.52.52.5
BNC to banana adapters included n/a n/a n/a n/a n/a n/a n/a n/a n/a
Basic accuracy: % reading plus floorspec.
1
n/a = not applicable
Loading...