TECHNICAL DATA
Fluke T6 Electrical Testers
with FieldSense technology
Measure voltage…without test leads
Measure voltage up to 1000 V ac through the open fork, without test
lead contact to live voltage.
wire nuts. On wires up to AWG 4/0 (120 mm
200 A. It will change your job. Safer. Faster. Easier.
+
Without opening covers or removing
2
), carrying as much as
Product Highlights
• FieldSense technology for ac voltage, current and frequency
measurement without making electrical contact to live voltage
• Simultaneous voltage and current display (T6-1000)—
shows all power supply measurements at a glance for
efficient troubleshooting
• 1 to 1000 V ac or dc (T6-1000); 600 V ac or dc (T6-600)
• 0.1 to 200 A ac
• Resistance 1 Ω to 100 kΩ (T6-1000), 1 Ω to 1000 Ω (T6-600)
• Frequency measurement 45 Hz to 66 Hz (T6-1000)
• Works with wires up to AWG 4/0 (120 mm
17.8 mm jaw opening.
• HOLD button temporarily freezes the reading for easy viewing
• Easy to read display with backlight
• Accepts optional Fluke TPAK Magnetic Meter Hanger for
convenient operation
• Standard two-year warranty; extendable to four years through
product registration within 45 days of purchase*
+ Requires capacit ive pat h to ground, provided th rough user in most applications.
Ground connection via test lead may be req uired in some situations.
* Register product online within 45 days of purchase to extend warranty to four years.
See http://a.fluke.com/registration for details.
2
) with a
+
Specifications
Measurement Specifications
T6-600 T6-1000
Function Requires test leads Range Range Resolution Accuracy
FieldSense ac voltage No 600 V 1000 V 1 V
FieldSense ac cu rrent No 200.0 A 200.0 A 0.1 A
FieldSense frequency
(Hz)
Volts ac Yes 600 V 1000 V 1 V
Volts dc Yes 600 V 1000 V 1 V ±(1 % + 2 counts)
Resistance Yes 1000 Ω 1000 Ω 1 Ω ±(1 % + 2 counts)
Safety
(measurement category)
(1)
Accuracy
Accuracy
Accuracy
: ± ( [ % of reading] + [number of lea st sig ni ficant digits] ). Ac curacy is spec ified for 1 year after calibrat ion, at 18 °C to 28 °C (64 °F to 82 °F)
with r elative hum idit y to 90 %. AC conversions are ac-c oupled , RMS responding.
(2)
: Add 3 % without an ex tern al ground c onnection. Ex tern al ground c onne ction required for us er wearing i nsu lated gloves, standing on an
insulated ladder a nd otherw ise insu lated f rom ea rth grou nd.
(3)
: F ieldSense specified f rom 16V to 100% of range.
No 45 Hz – 66 H z 1 H z
Yes 10.0 0 kΩ 0.01 k Ω
Yes 100 .0 kΩ 0.1 kΩ
600 V CAT I II
1000 V CAT III
600 V CAT I V
[1]
±(3 % + 3 count s)
45 Hz - 66 H z
±(3 % + 3 count s)
45 Hz - 66 H z
±(1 % + 2 counts)
±(1.5 % + 2 counts)
45 Hz - 66 H z
General Specifications
Calibration 1-year ca libration cycle
Dimensions 61.1 mm x 259.3 mm x 43.8 mm
Fork opening 17.8 m m
Temperature
Operating:
Stor age:
Altitude
Operating:
Stor age:
Relative Humidity 0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)
Batter y Ty pe and Life 2 x AA (IEC LR6); 360 hours continuou s, ty pica l; 200 hours u sing
RF Field Specification 0.5 % fu ll sc ale + (s pecified ac curacy) at 3 V / m
Enclosure Rating IP 52 per I EC/E N 60529, no vacuu m applied
Temperature coefficient 0.1 x (speci fied ac curacy) / °C for <18°C or >28 °C
Safety IEC/EN 61010-1, IEC/ EN 61010-2-033: Pollution Degree 2
Electromagnetic Env ironment IEC/EN 61326-1: Portable
-10 °C to +50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
2,000 m (6,562 feet)
10,000 m (32, 808 feet)
0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F )
0 % to 45 %, 40°C to 50 ° C (104 °F to 122 °F)
FieldSense
(< 64.4 °F or > 82.4 ° F)
[2] [3]
[3]
Ordering information
Fluke T6-600 Electrical Tester
Fluke T6-1000 Electrical Tester
Included with product
Attached test leads with removable 4 mm probe caps,
user documentation
Optional accessories
H-T6 Belt Holster
TPAK Magnetic Hanger
PRV240FS Proving Unit
TP1 Probe Set, Flat-Blade (US/UK flat tip)
TP38 Probe set, round (EU)
AC285 SureGrip Alligator Clips
AC220 SureGrip Alligator Clips
Service Information Sheet, PN 686953
* Two-year additional w arr anty offer may be di scont inue d wit hout not ice
2 Fluke Corporation Fluke T6 Electrical Testers with FieldSense technolog y
Fluke. Keeping your world
up and running.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
Modification of this document is not
permitted without written permission
from Fluke Corporation.
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0)40 267 5100
or Fax +31 (0)40 267 5222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2017 Fluke Corporation.
Specifications subject to change without notice.
7/2017 6009251a-en
®