T5-600
Continuity, Current and
Voltage Tester
Electrical tester with
™
OpenJaw
The Fluke T5Electrical Testerslet you check
voltage, continuity and current with one compact tool. With the T5, all you have to do is
select volts, ohms, or current and the tester
does the rest. OpenJaw
current up to 100 A—without breaking the circuit.
Its tough test leads stow neatly in the back of
the tester, making it easy to carry the T5 in your
tool bag. Detachable SlimReach
customized for electrical standards. The test leads
accept optional accessories such as clips and specialty probes. The optional H5 holster lets you clip
the T5 onto your belt.
current
™
current lets you check
™
test probes are
Technical Data
Features
Automatically measures volts ac and volts dc
•
with precise digital resolution
Displays resistance to 1000 Ω
•
Easy and accurate OpenJaw™ current
•
measurement
Continuity beeper
•
Compact design with neat probe storage
•
Rugged enough to withstand a 3-meter drop
•
Detachable SlimReach™ probe tips are
•
customized for national electrical standards
Test leads accept Fluke accessory test clips
•
Overvoltage category: 600 V ac/dc, CAT III
•
Stay connected much longer than solenoid
•
type tester
Auto off mode to conserve battery life
•
Optional holster attaches to a belt and neatly
•
stows test leads
Features
AC current
AC voltage
Resistance
Continuity
DC volts
Display hold
Auto off
•
•
•
•
•
•
•
Specifications
Jaw opening 12.9 mm (0.5 in)
Max wire size 1/0 THHN Cable
Current range ac rms 0 to 100.0 A
Accuracy ac current (50/60 Hz) 3 % ± 3 counts
AC Response Averaging
Voltage range ac 0 to 600 V
Accuracy ac voltage 1.5 % ± 2 counts
Voltage range dc 0 to 600 V
Accuracy dc voltage 1 % ± 1 count
Resistance range 0 to 1000 Ω
Continuity beeper threshold On at <25 Ω, off at >400 Ω
Volts indicator LED threshold Guaranteed on by 30 V ac
Environmental specifications
Operating temperature -10 °C to 50 °C
Storage temperature -30 °C to 60 °C
Humidity (without condensation) 0 % to 95 % (5 °C to 30 °C); 0 % to 75 % (30 °C to 40 °C);
0 % to 45 % (40 °C to 50 °C)
Dust/water resistance Yes
Operating altitude 2000 meters max
Temperature coefficient 0.1 x (specified accuracy)/°C (<18 °C or >28 °C)
Safety specifications
Overvoltage category CAT III 600 V ac/dc (EN61010-1)
Agency approvals CSA, TUV and CE
Maximum voltage Between any terminal and earth ground
Mechanical and general specifications
Size 30.5 mm x 51 mm x 203 mm
Weight 300 g
Warranty Two-years
Battery life 200 hour zinc chloride, 400 hour alkaline
Battery type 2 x AA
Low battery indicator Yes
Current sensor opening 12.9 mm
Calibration cycle One-year
Test leads Type: Heavy duty, flexible leads rated for 1000 V use
Field replaceable leads terminate in male shrouded banana plugs
Probes: One red, one black
Detachable Slim-Reach™ probe tips
Styles: TP1 Slim Reach™ Test Probes
2 Fluke Corporation T5-600 Continuity, Current and Voltage Tester
Ordering information
T5-600 Continuity, Current and
Non-Contact Voltage Tester
Fluke. Keeping your world
up and running.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2012-2014 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 5/2014 4234957B_EN
Modification of this document is not permitted
without written permission from Fluke Corporation.
®