Fluke ScopeMeter 190B Series, ScopeMeter 190C Series User Manual

4822 872 00741 Nov. 2002, Rev.1 3/04
© 2002 , 2003 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies.
Fluke 190B/C
Medical Functions
Users Manual Supplement
Chapter Title Page
1 General.......................................................................................................................... 1-1
About this Manual .......................................................................................................... 1-1
Safety Information.......................................................................................................... 1-1
Limited Warranty, Limitation of Liability......................................................................... 1-1
About the Medical Version ............................................................................................. 1-2
MA 190 Accessory Kit.................................................................................................... 1-2
2 Using the Medical Functions....................................................................................... 2-1
mAs Measurements ....................................................................................................... 2-1
mVs measurements ................................................................................................. 2-3
mWs measurements ................................................................................................. 2-3
Extended Offset ............................................................................................................. 2-4
Oscilloscopes and dynamic range............................................................................. 2-5
Triggering .................................................................................................................. 2-6
Tip for video signal measurements............................................................................ 2-6
Specifications ............................................................................................................ 2-6
Smart Average ............................................................................................................... 2-7
Smart average vs. normal average ........................................................................... 2-8
Non Interlaced Video Triggering..................................................................................... 2-9
Chapter 1
General
About this Manual
This manual supplement is an addition to the Users Manual that is included with the ScopeMeter 190B/C series test tool kit. It provides user information about the extended test tool functionality that is available in the Fluke190B/C /M versions.
Safety Information
Read and comply with the safety instructions that you find in the ScopeMeter 190B/C series Getting Started Manual and Users Manual.
The MA 190 kit accessories are intended for low voltage (42 Vpk) use only, and do not comply with the voltage rating on most other ScopeMeter accessories. Carefully read the warning below which is an explicit addition to the general accessory and ScopeMeter safety statements.
Warning
To avoid electrical shock or fire, do NOT connect the following accessories to voltages more than 42 Vpk (30 Vrms) or circuits of more than 4800 VA :
CS 190-1R, 1 Ohm shunt resistor
TR 190-50R, 50 Ohm terminator
TA 190-50R, 50 Ohm terminator / 10:1
attenuator
Limited Warranty, Limitation of Liability
Read the Warranty and Limitation of Liability statements that you find in the ScopeMeter 190B/C Users Manual that is included in the test tool kit shipment (on CD).
1-1
Fluke 190B/C Medical
ST8723
User Manual
About the Medical Version
The /M Medical version is a standard Fluke 190B/C Series ScopeMeter test tool with the following additional functionality:
mAs measurements
non interlaced video triggering
smart averaging
extended offset
MA 190 Accessory Kit
The MA 190 is an optional accessory kit that provides optimal connectivity to the ScopeMeter test tool in medical and video applications.
Before use carefully read the WARNING on page 1-1.
The kit contains:
TR 190-50R, 50 Ohm BNC feed-through terminator for video and HF measurements (Max. 5 V) . See Fig. 1-1.
TA 190-50R, 50 Ohm 10:1 attenuator feed-through terminator for additional dynamic range and offset. See Fig. 1-1.
CS 190-1R, 1 Ohm current shunt for sensitive current and mAs measurements. (Max. 500 mA)
. See Fig. 2-1.
Safety designed 50 Ohm BNC cable with isolated plastic connectors. (1.5 m)
Female BNC to male 4 mm banana plug adapter
Two female to female 4 mm banana plug adapters
Note 1
CS 190-1R, the TR 190-50R, and the
The TA 190-50R are not available as individual accessory, but only as part of the MA 190 kit.
VIDEO SIGNAL SOURCE
50 BNC CABLE
TR190-50R
or
TA190-50R
Figure 1-1. 50 Ohm cable termination using the
TR190-50R or TA190-50R
1-2