The Fluke Norma 6000 Series Portable Wideband Precision Power
Analyzers give you more freedom than ever before to make high
accuracy power measurements wherever you need to—whether
in the lab, or in the field. Designed for portability the lightweight,
battery powered Fluke 6000 Series eliminates the need to carry
large, fragile, expensive analyzers into the field, allowing you to
make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the
equipment operates under real-world conditions, with real-world
variables, not just at a test bench or in the lab.
The Fluke 6003 includes three measurement channels which
each consist of a voltage and current input making it ideal for
three-phase power measurements. The Fluke 6004 includes four
measurement channels giving it the capability to measure threephase power and DC power simultaneously to enable real-time
inverter efficiency measurements under real-world conditions.
The Fluke 6003+ and 6004+ models both add the capability to
measure mechanical parameters such as speed and torque (from
separate transducers) to discover the electrical to mechanical
efficiency of the load under a variety of typical operating modes.
With the addition of optional measurement accessories, you can
even make measurements up to 1,500V DC and 2,000A AC+DC on
conductors with a diameter of up to 52mm.
KEY MEASUREMENTS
Voltage, Current, Active Power, Reactive Power,
Apparent Power, Power Factor and Harmonics with
associated values
HIGH ACCURACY AND WIDE
BANDWIDTH
0.1 % measurement accuracy and 500kHz
bandwidth
HIGHLY PORTABLE
Battery powered, weighs 3.5kg, operates for up to
10 hours without a power cord
The instrument’s compact, battery-powered design combined
with a wideband frequency response makes it easier than ever to
make measurements on hard to access systems such as inverter
drive systems, DC-AC and AC-DC power conversion systems and
electric motors without removing them from service. Making these
measurements in the field simplifies the troubleshooting and performance measurement processes without sacrificing uptime, giving
you more accurate test results that will enable you to discover
whether your loads are operating as effectively and efficiently as
they should be.
• Highly portable and easily installed in tight spaces—only 9.6 cm
thick.
• Operate continuously for up to 10 hours without an external
power supply using the 5000mAh Li-ion Internal Battery.
• Measure safely—safety rated for CAT III 1000V, CAT IV 600V
environments.
• Measure three phase power and DC output power at the same
time with 3 or 4 channel models, with voltage and current inputs
on each channel.
• Make mechanical torque and speed measurements using the
included inputs and outputs of the Fluke 6003+ and 6004+.
Page 2
• 0.1% accuracy, 500kHz bandwidth, 200ks/s sample rate so you
can rely on the power conversion system measurements you take
no matter what distortion may be present.
• USB and RS485 interface and open communication protocol for
easy system integration and software platform flexibility.
• Combine two analyzers to enable simultaneous measurement of
multiple circuits for even more troubleshooting capability—configurable to 6 or 8 channels using dual analyzer synchronization.
• View critical data in the field on the main display—Meter, Wave-
form, Harmonics up to the 100th, Vector and Trend.
• Ensure high common-mode rejection and allow flexible
configurations according to measurement requirements using the
electrically isolated channels.
• User adjustable measurement rate from 100ms to 1s with con-
tinuous logging via 32GB of onboard storage.
• Easy in-field set up using the integrated front panel or a remote
PC connection (USB or RS485).
• Online measuring, data download and analysis with included PC
software (Fluke Power Analyzer Software).
• Full remote control of the connected instrument using Fluke
Power Analyzer Software and a local USB or long-distance
RS485 connection.
≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)
2000m
12000m
IP 50 (Terminals mated) according to IEC 60529:
Operating time: 10 Hours (on batter y)
IEC 61010-2-030: CAT IV 600V, CAT III 1000 V
IEC 61326-1: Industrial
IEC 61326-2-2
1 Year
2 Fluke Corporation Fluke Norma 6000 Series Portable Power Analyzers
Page 3
Communication Interface
Dual Analyzer Synchronization Mode
PC Software
Storage Capacity
Data trend storage rate
Main Function
Measuring ParametersRMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor,
USB/RS485
Able to extend to 6, 7 or 8 channels (using multiple instruments)
Fluke Power Analyzer software
32GB
As per display rate
Meter, Scope, Harmonic, Phasor, Trend
Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic
Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent
Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge
capacity (Ah), Frequency, Motor Speed, Torque, Mechanical Power, Mechanical Energy, Summation function
Bandwidth10 A range: 500 kHz; 1 A range: 200 kHz; 0.1 A range: 100 kHz
BNC (voltage input)
Range0.1 V, 1 V, 10 V
Input Impedance100k Ω/100pF (Typical)
Bandwidth10 V range: 500 kHz; 1 V range: 200 kHz; 0.1 V range: 100 kHz
3 Fluke Corporation Fluke Norma 6000 Series Portable Power Analyzers
Page 4
Accuracy (% reading + % range)
Range10 A1 A0.1 A10 V1 V0.1 V
DC0.1 + 0.20.1 + 0.50.1+20.1+0 .10.1+0.20.1+1
AC (10Hz to 1kHz)0.1+0 .10.1+0.20.1+10.1+0.10.1+0.10.1+0.5
AC (10k H z )5+15+15+15+15+15+1
Motor Module (Torque and Speed)
Voltage Range± 10 V dc, 10 % overload
Voltage Channels2
Input Impedance1.1M Ω (Typical)
Accuracy at dc0.1 % range + 0.1 % reading
Pulse Channels3
Pulse Logic High Threshold
Pulse Logic Low Threshold
Maximum Pulse Frequency
2 V (Typical)
0.8 V (Typical)
100 k Hz
Frequency Domain Measurement
Frequency Accuracy
Harmonics
Calculation method
0.05 % range + 0.05 % reading
100 (50Hz/60Hz)
FFT/Interpolation
Optional Accessory: Fluke U1500s High Voltage Differential Probe
Product Feature
The Fluke U1500s High Voltage Differential Probe is a portable voltage sensor with a 1500 V range and 0.1 % accuracy.
General Specifications
Modules
Maximum Voltage
Dimensions
Weight
Input terminal
4 Fluke Corporation Fluke Norma 6000 Series Portable Power Analyzers
U1500s
1000 V ac rms, continuous, 1500 V dc (Single-range)
138 mm x 75 mm x 45 mm
295 g, battery included
4 mm banana jacks
Page 5
Output terminal
Accessory Cable
Ingress Protection
Battery Type
Battery Life
IndicatorLow battery flashes red
Operating Temperature
Storage Temperature
Operating HumidityNon-condensing (<10 °C)
Operating Altitude
Storage Altitude
Safety General
Safety Measurement
BNC (female)
BNC to Banana, 1.6 m
IEC 60529: IP40 (Terminals Mated)
4 AA, IEC LR6
168 hours (typical)
Working flashes green
-10 °C to 50 °C
-30 °C to 60 °C
≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)
2000 m
12 000 m
IEC 61010-1: Pollution Degree 2
IEC 61010-2-030: CAT III 1000 V, CAT IV 600 V, DC 1500 V
Electrical Specifications
Measurement Range1000 V ac rms, 1500 V dc
Accuracy0.1 % of reading +0.1 % of Range
Bandwidth100 kHz (Max)
Input Impedance10 MΩ / <10 pF
Scale4 mV/ V
Common Mode Rejection Ratio60 dB at 50 Hz
Temperature Coefficients0.05 % / °C (<18 °C or >28 °C)
Over-range Protection10 % over range
5 Fluke Corporation Fluke Norma 6000 Series Portable Power Analyzers
Page 6
Optional Accessory: Fluke 80i-2010s AC/DC Current Clamp
Product Feature
The Fluke 80i-2010s AC/DC Current Clamp is a clamp-on current probe with 2000A range and 0.8 % accuracy.
General Specifications
Modules
Dimensions
Weight
Output Cable
Maximum Conductor Size
Maximum Jaw Opening
Output to Zero
Temperature Operating
Storage (battery removed)
Operating Humidity
Altitude Operating
Storage
Demagnetize ClampOpen and close the Clamp jaws several times with soft click, use of the clamp on
Safety
Ingress Protection
Power Supply Type
Battery Life
Low battery indicator
80 i -2010s
110 mm x 270 mm x 46mm
0.710 kg (1.6 lbs), including battery
1.5 m (60 in) Shielded Coaxial cable with BNC plug
52.0 mm (2.05 in)
81.5 mm
Auto adjustment with Zero button
-10 °C to 50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C)
2,000 m (6560 ft)
12,000 m (40,000 ft)
uninsulated conductors is limited to 1000 Vac rms or DC and frequencies 1 kHz or less.
IEC 61010-1, Pollution Degree 2, IEC 61010-2-032: CAT III 1000 V /CAT IV 600 V
IEC 60529, IP40
2 x AA alkaline battery, IEC LR6
150 hours (typically)
Yes
6 Fluke Corporation Fluke Norma 6000 Series Portable Power Analyzers
Page 7
Electrical Specifications
Current Range2000 A ac rms, ± 2000 A dc
Output Sensitivity1 mV/A
Accuracy± 0.8 % of reading ± 0.2 % of range
Bandwidth for Accuracy SpecificationDC to 400 Hz
Load impedance>1 MΩ and <10 pF
Frequency Response (small signal)DC to 20 kHz (-3 dB)
Temperature Coefficient0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Working Voltage1000 V AC RMS or DC
Ordering information
Fluke-Norma 6003Portable power analyzer with 3 voltage
inputs and 3 current inputs
Fluke-Norma 6003+Portable power analyzer with 3 voltage
inputs, 3 current inputs, and 1 motor input
Fluke-Norma 6004Portable power analyzer with 4 voltage
inputs and 4 current inputs
Fluke-Norma 6004+Portable power analyzer with 4 voltage
inputs, 4 current inputs, and 1 motor input
Optional accessories
Flu ke U1500SHigh Voltage Differential Probe
Fluke 80i-2010S2,000 A AC/DC Current Clamp
Fluke 80i-2010S/3PK2,000 A AC/DC Current Clamp 3 pack
Fluke. Keeping your world
up and running.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0)40 267 5100 or
Fax +31 (0)40 267 5222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com