Fluke Norma 6000 Specifications

Page 1
TECHNICAL DATA
Fluke Norma 6000 Series Portable Power Analyzers
Accurate enough for the lab, built for the field
The Fluke Norma 6000 Series Portable Wideband Precision Power Analyzers give you more freedom than ever before to make high accuracy power measurements wherever you need to—whether in the lab, or in the field. Designed for portability the lightweight, battery powered Fluke 6000 Series eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environ­ment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab.
The Fluke 6003 includes three measurement channels which each consist of a voltage and current input making it ideal for three-phase power measurements. The Fluke 6004 includes four measurement channels giving it the capability to measure three­phase power and DC power simultaneously to enable real-time inverter efficiency measurements under real-world conditions. The Fluke 6003+ and 6004+ models both add the capability to measure mechanical parameters such as speed and torque (from separate transducers) to discover the electrical to mechanical efficiency of the load under a variety of typical operating modes. With the addition of optional measurement accessories, you can even make measurements up to 1,500V DC and 2,000A AC+DC on conductors with a diameter of up to 52mm.
KEY MEASUREMENTS
Voltage, Current, Active Power, Reactive Power, Apparent Power, Power Factor and Harmonics with associated values
HIGH ACCURACY AND WIDE BANDWIDTH
0.1 % measurement accuracy and 500kHz bandwidth
HIGHLY PORTABLE
Battery powered, weighs 3.5kg, operates for up to 10 hours without a power cord
The instrument’s compact, battery-powered design combined with a wideband frequency response makes it easier than ever to make measurements on hard to access systems such as inverter drive systems, DC-AC and AC-DC power conversion systems and electric motors without removing them from service. Making these measurements in the field simplifies the troubleshooting and per­formance measurement processes without sacrificing uptime, giving you more accurate test results that will enable you to discover whether your loads are operating as effectively and efficiently as they should be.
• Highly portable and easily installed in tight spaces—only 9.6 cm thick.
• Operate continuously for up to 10 hours without an external power supply using the 5000mAh Li-ion Internal Battery.
• Measure safely—safety rated for CAT III 1000V, CAT IV 600V environments.
• Measure three phase power and DC output power at the same time with 3 or 4 channel models, with voltage and current inputs on each channel.
• Make mechanical torque and speed measurements using the included inputs and outputs of the Fluke 6003+ and 6004+.
Page 2
• 0.1% accuracy, 500kHz bandwidth, 200ks/s sample rate so you can rely on the power conversion system measurements you take no matter what distortion may be present.
• USB and RS485 interface and open communication protocol for easy system integration and software platform flexibility.
• Combine two analyzers to enable simultaneous measurement of multiple circuits for even more troubleshooting capability—con­figurable to 6 or 8 channels using dual analyzer synchronization.
• View critical data in the field on the main display—Meter, Wave- form, Harmonics up to the 100th, Vector and Trend.
• Ensure high common-mode rejection and allow flexible configurations according to measurement requirements using the electrically isolated channels.
• User adjustable measurement rate from 100ms to 1s with con- tinuous logging via 32GB of onboard storage.
• Easy in-field set up using the integrated front panel or a remote PC connection (USB or RS485).
• Online measuring, data download and analysis with included PC software (Fluke Power Analyzer Software).
• Full remote control of the connected instrument using Fluke Power Analyzer Software and a local USB or long-distance RS485 connection.
Specifications
Inputs Norma 6003 3 Voltage + 3 Current
Norma 6003+ 3 Voltage + 3 Current + 1 Motor
Norma 6004 4 Voltage + 4 Current
Norma 6004+ 4 Voltage + 4 Current + 1 Motor
Sample rate
Measurement update rate
Dimensions (H * W * L)
Weight
Display
Operating temperature
Storage temperature
Operating humidity Non-condensing (< 10 °C )
Operating altitude
Storage altitude
Ingress protection
Battery BP 291, 10.8V/5000mAh, 54Wh IEC 62133, UN38.3
Safety IEC 61010-1: Pollution Degree 2
EMC
Warranty
200ks/s
100ms, 200ms, 500ms, 1s
298mm x 215m x 96mm
3.5 kg (7.7 lbs)
5.7 inch, TFT LCD, 640x480
-10 °C to +50 °C
-30 °C to +60 °C
≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C)
2000m
12000m
IP 50 (Terminals mated) according to IEC 60529:
Operating time: 10 Hours (on batter y)
IEC 61010-2-030: CAT IV 600V, CAT III 1000 V
IEC 61326-1: Industrial IEC 61326-2-2
1 Year
2 Fluke Corporation Fluke Norma 6000 Series Portable Power Analyzers
Page 3
Communication Interface
Dual Analyzer Synchronization Mode
PC Software
Storage Capacity
Data trend storage rate
Main Function
Measuring Parameters RMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor,
USB/RS485
Able to extend to 6, 7 or 8 channels (using multiple instruments)
Fluke Power Analyzer software
32GB
As per display rate
Meter, Scope, Harmonic, Phasor, Trend
Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge capacity (Ah), Frequency, Motor Speed, Torque, Mechanical Power, Mechanical Energy, Sum­mation function
Electrical specifications
Voltage
Range 10 V, 100 V, 1000 V
Crest Factor CF ≤ 2
Maximum Voltage 10 % overload
Input Impedance 2M Ω/10pF (Typical)
Temperature Coefficient 0.05 * (Spec)/k
Bandwidth 1000V range: 500kHz; 100V range: 200 kHz;
CMRR
10V ra nge:100 kHz
120 dB @ 50/60 Hz
Accuracy (% reading + % range)
Range 1000 V 100 V 10 V
DC 0.1 + 0.1 0.1 + 0.1 0.1 + 0.2
AC (10Hz to 1kHz) 0.1 + 0.1 0.1 + 0.1 0.1 + 0.2
AC (10k H z ) 5 + 0.5 5 + 0.5 5 + 0.5
Current
Crest Factor CF ≤ 2
Temperature Coefficient 0.05 x (Spec)/k
Overload capacity 10 % overload
CMRR 120 dB @ 50/60 Hz
Shunt (current input)
Measuring Range 0.1 A, 1 A, 10 A
Input Impedance 0.025 Ω (Typical)
Bandwidth 10 A range: 500 kHz; 1 A range: 200 kHz; 0.1 A range: 100 kHz
BNC (voltage input)
Range 0.1 V, 1 V, 10 V
Input Impedance 100k Ω/100pF (Typical)
Bandwidth 10 V range: 500 kHz; 1 V range: 200 kHz; 0.1 V range: 100 kHz
3 Fluke Corporation Fluke Norma 6000 Series Portable Power Analyzers
Page 4
Accuracy (% reading + % range)
Range 10 A 1 A 0.1 A 10 V 1 V 0.1 V
DC 0.1 + 0.2 0.1 + 0.5 0.1+2 0.1+0 .1 0.1+0.2 0.1+1
AC (10Hz to 1kHz) 0.1+0 .1 0.1+0.2 0.1+1 0.1+0.1 0.1+0.1 0.1+0.5
AC (10k H z ) 5+1 5+1 5+1 5+1 5+1 5+1
Motor Module (Torque and Speed)
Voltage Range ± 10 V dc, 10 % overload
Voltage Channels 2
Input Impedance 1.1M Ω (Typical)
Accuracy at dc 0.1 % range + 0.1 % reading
Pulse Channels 3
Pulse Logic High Threshold
Pulse Logic Low Threshold
Maximum Pulse Frequency
2 V (Typical)
0.8 V (Typical)
100 k Hz
Frequency Domain Measurement
Frequency Accuracy
Harmonics
Calculation method
0.05 % range + 0.05 % reading
100 (50Hz/60Hz)
FFT/Interpolation
Optional Accessory: Fluke U1500s High Voltage Differential Probe
Product Feature
The Fluke U1500s High Voltage Differential Probe is a portable voltage sensor with a 1500 V range and 0.1 % accuracy.
General Specifications
Modules
Maximum Voltage
Dimensions
Weight
Input terminal
4 Fluke Corporation Fluke Norma 6000 Series Portable Power Analyzers
U1500s
1000 V ac rms, continuous, 1500 V dc (Single-range)
138 mm x 75 mm x 45 mm
295 g, battery included
4 mm banana jacks
Page 5
Output terminal
Accessory Cable
Ingress Protection
Battery Type
Battery Life
Indicator Low battery flashes red
Operating Temperature
Storage Temperature
Operating Humidity Non-condensing (<10 °C)
Operating Altitude
Storage Altitude
Safety General
Safety Measurement
BNC (female)
BNC to Banana, 1.6 m
IEC 60529: IP40 (Terminals Mated)
4 AA, IEC LR6
168 hours (typical)
Working flashes green
-10 °C to 50 °C
-30 °C to 60 °C
≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C)
2000 m
12 000 m
IEC 61010-1: Pollution Degree 2
IEC 61010-2-030: CAT III 1000 V, CAT IV 600 V, DC 1500 V
Electrical Specifications
Measurement Range 1000 V ac rms, 1500 V dc
Accuracy 0.1 % of reading +0.1 % of Range
Bandwidth 100 kHz (Max)
Input Impedance 10 MΩ / <10 pF
Scale 4 mV/ V
Common Mode Rejection Ratio 60 dB at 50 Hz
Temperature Coefficients 0.05 % / °C (<18 °C or >28 °C)
Over-range Protection 10 % over range
5 Fluke Corporation Fluke Norma 6000 Series Portable Power Analyzers
Page 6
Optional Accessory: Fluke 80i-2010s AC/DC Current Clamp
Product Feature
The Fluke 80i-2010s AC/DC Current Clamp is a clamp-on current probe with 2000A range and 0.8 % accuracy.
General Specifications
Modules
Dimensions
Weight
Output Cable
Maximum Conductor Size
Maximum Jaw Opening
Output to Zero
Temperature Operating
Storage (battery removed)
Operating Humidity
Altitude Operating
Storage
Demagnetize Clamp Open and close the Clamp jaws several times with soft click, use of the clamp on
Safety
Ingress Protection
Power Supply Type
Battery Life
Low battery indicator
80 i -2010s
110 mm x 270 mm x 46mm
0.710 kg (1.6 lbs), including battery
1.5 m (60 in) Shielded Coaxial cable with BNC plug
52.0 mm (2.05 in)
81.5 mm
Auto adjustment with Zero button
-10 °C to 50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C)
2,000 m (6560 ft)
12,000 m (40,000 ft)
uninsulated conductors is limited to 1000 Vac rms or DC and frequencies 1 kHz or less.
IEC 61010-1, Pollution Degree 2, IEC 61010-2-032: CAT III 1000 V /CAT IV 600 V
IEC 60529, IP40
2 x AA alkaline battery, IEC LR6
150 hours (typically)
Yes
6 Fluke Corporation Fluke Norma 6000 Series Portable Power Analyzers
Page 7
Electrical Specifications
Current Range 2000 A ac rms, ± 2000 A dc
Output Sensitivity 1 mV/A
Accuracy ± 0.8 % of reading ± 0.2 % of range
Bandwidth for Accuracy Specification DC to 400 Hz
Load impedance >1 MΩ and <10 pF
Frequency Response (small signal) DC to 20 kHz (-3 dB)
Temperature Coefficient 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Working Voltage 1000 V AC RMS or DC
Ordering information
Fluke-Norma 6003 Portable power analyzer with 3 voltage
inputs and 3 current inputs
Fluke-Norma 6003+ Portable power analyzer with 3 voltage
inputs, 3 current inputs, and 1 motor input
Fluke-Norma 6004 Portable power analyzer with 4 voltage
inputs and 4 current inputs
Fluke-Norma 6004+ Portable power analyzer with 4 voltage
inputs, 4 current inputs, and 1 motor input
Optional accessories
Flu ke U1500S High Voltage Differential Probe
Fluke 80i-2010S 2,000 A AC/DC Current Clamp
Fluke 80i-2010S/3PK 2,000 A AC/DC Current Clamp 3 pack
Fluke. Keeping your world up and running.
Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0)40 267 5100 or Fax +31 (0)40 267 5222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2019 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 12/2019 6013111a-en
Modification of this document is not permitted without written permission from Fluke Corporation.
®
7 Fluke Corporation Fluke Norma 6000 Series Portable Power Analyzers
Loading...