Each Fluke Networks product is warranted to be free from defects in material and
workmanship under normal use and service. The warranty period for the mainframe is
one year and begins on the date of purchase. Parts, accessories, product repairs and
services are warranted for 90 days, unless otherwise stated. Ni-Cad, Ni-MH and Li-Ion
batteries, cables or other peripherals are all considered parts or accessories. The
warranty extends only to the original buyer or end user customer of a Fluke Networks
authorized reseller, and does not apply to any product which, in Fluke Networks’
opinion, has been misused, abused, altered, neglected, contaminated, or damaged by
accident or abnormal conditions of operation or handling. Fluke Networks warrants
that software will operate substantially in accordance with its functional specifications
for 90 days and that it has been properly recorded on non-defective media. Fluke
Networks does not warrant that software will be error free or operate without
interruption.
Fluke Networks authorized resellers shall extend this warranty on new and unused
products to end-user customers only but have no authority to extend a greater or
different warranty on behalf of Fluke Networks. Warranty support is available only if
product is purchased through a Fluke Networks authorized sales outlet or Buyer has
paid the applicable international price. Fluke Networks reserves the right to invoice
Buyer for importation costs of repair/replacement parts when product purchased in
one country is submitted for repair in another country.
Fluke Networks warranty obligation is limited, at Fluke Networks option, to refund of
the purchase price, free of charge repair, or replacement of a defective product which
is returned to a Fluke Networks authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke Networks authorized service
center to obtain return authorization information, then send the product to that
service center, with a description of the difficulty, postage and insurance prepaid (FOB
destination). Fluke Networks assumes no risk for damage in transit. Following
warranty repair, the product will be returned to Buyer, transportation prepaid (FOB
destination). If Fluke Networks determines that failure was caused by neglect, misuse,
contamination, alteration, accident or abnormal condition of operation or handling,
or normal wear and tear of mechanical components, Fluke Networks will provide an
estimate of repair costs and obtain authorization before commencing the work.
Following repair, the product will be returned to the Buyer transportation prepaid and
the Buyer will be billed for the repair and return transportation charges (FOB Shipping
point).
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY
IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
FLUKE NETWORKS SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM
ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied
warranty, or exclusion or limitation of incidental or consequential damages, the
limitations and
provision of this Warranty is held invalid or unenforceable by a court or other decisionmaker of competent jurisdiction, such holding will not affect the validity or
enforceability of any other provision.
ions of this warranty may not apply to every buyer. If any
exclus
4/04
Fluke Networks
PO Box 777
Everett, WA 98206-0777
USA
Chapter 1Get Acquainted
Overview of the CertiFiber Pro Optical Loss
Test Set Modules .............................................................1
Overview of the CertiFiber Pro Optical Loss
Test Set Modules
The Fluke Networks CertiFiber® Pro Optical Loss Test Set (OLTS)
modules attach to Versiv
rugged, hand-held testers that let you certify, troubleshoot, and
document optical fiber cabling installations. The testers include
these features:
Measures optical power loss and length on dual-fiber,
multimode cabling at 850 nm and 1300 nm (CFP-MM) or on
dual-fiber singlemode cabling at 1310 nm and 1550 nm
(CFP-SM). The four-wavelength module (CFP-QUAD) measures
at 850 nm, 1300 nm, 1310 nm, and 1550 nm.
Interchangeable connector adapters on input and output
ports let you make reference and test connections that agree
with ISO standards for most SFF (small form factor)
connectors.
Visual fault locator helps you find breaks, bad splices, and
bends and verify fiber continuity and polarity.
You can save approximately 30,000 fiber test results in the
tester’s internal memory. You can save more results on a
removable flash drive.
™
main and remote units to make
1
CertiFiber Pro Fiber Optical Loss Test Set
Users Manual
Contact Fluke Networks
www.flukenetworks.com
support@flukenetworks.com
+1-425-446-4519
Fluke Networks
PO Box 777
Everett, WA 98206-0777
USA
Australia: 61 (2) 8850-3333 or 61 (3) 9329 0244
Beijing: 86 (10) 6512-3435
Brazil: 11 3759 7600
Canada: 1-800-363-5853
Europe: +31-(0) 40 2675 600
Hong Kong: 852 2721-3228
Japan: 03-6714-3117
Korea: 82 2 539-6311
Singapore: +65-6799-5566
Taiwan: (886) 2-227-83199
USA: 1-800-283-5853
Visit our website for a complete list of phone numbers.
Register Your Product
Registering your product with Fluke Networks gives you access to
valuable information on product updates, troubleshooting tips,
and other support services. To register, fill out the online
registration form on the Fluke Networks website at
www.flukenetworks.com.
2
Chapter 1: Get Acquainted
Technical Reference Handbook
Technical Reference Handbook
The Versiv Technical Reference Handbook has more information
about the tester. The Handbook is on the Versiv Product Manuals
CD included with your product, and on the Fluke Networks
website.
Additional Resources
The Fluke Networks Knowledge Base answers common questions
about Fluke Networks products and provides articles on cable
testing techniques and technology.
To access the Knowledge Base, log on to www.flukenetworks.com,
then click SUPPORT > Knowledge Base.
Supplements and Updated Manuals
If necessary, Fluke Networks will put a supplement for this
manual, or an updated manual, on the Fluke Networks website.
To see if a supplement or updated manual is available, log on to
www.flukenetworks.com, click SUPPORT > Manuals, then select a
product.
Kit Contents
The CertiFiber Pro kits come with the accessories in the lists
below. If something is damaged or missing, contact the place of
purchase immediately.
3
CertiFiber Pro Fiber Optical Loss Test Set
Users Manual
CFP-100-M Kit
Versiv main and remote units with battery packs
Two CertiFiber Pro Multimode Optical Loss Test Set (OLTS)
Modules for tests at 850 nm and 1300 nm
Two encircled flux test reference cords (EF-TRCs) for 50 µm/
125 µm fiber, SC/LC connectors
Two test reference cords for 50 µm/125 µm fiber, LC/LC
Two LC/LC a d a pters
Carrying case for the testers
Case for the test reference cords
Two hand straps for the testers
USB cable for PC communications, type A USB to Micro-B USB
Two AC adapter/chargers
CertiFiber Pro Getting Started Guide
Versiv Product Manuals CD
LinkWare Software CD
CFP-100-S Kit
Versiv main and remote units with battery packs
Two CertiFiber Pro Singlemode Optical Loss Test Set (OLTS)
Modules for tests at 1310 nm and 1550 nm
Two test reference cords for singlemode fiber, SC/LC
Two test reference cords for singlemode fibers, LC/LC
Two LC/LC adapters
Carrying case for the testers
Case for the test reference cords
Two hand straps for the testers
4
Chapter 1: Get Acquainted
Kit Contents
USB cable for PC communications, type A USB to Micro-B USB
Two AC adapter/chargers
CertiFiber Pro Getting Started Guide
Versiv Product Manuals CD
LinkWare Software CD
CFP-100-Q Kit
Versiv main and remote units with battery packs
Two CertiFiber Pro Quad Optical Loss Test Set (OLTS) Modules
for tests at 850 nm, 1300 nm, 1310 nm and 1550 nm
Two encircled flux test reference cords (EF-TRCs) for 50 µm/
125 µm fiber, SC/LC
Two test reference cords for 50 µm/125 µm fiber, LC/LC
Two test reference cords for singlemode fiber, SC/LC
Two test reference cords for singlemode fiber, LC/LC
Two LC/LC adapters
Carrying case for the testers
Case for the test reference cords
Two hand straps for the testers
USB cable for PC communications, type A USB to Micro-B USB
Two AC adapter/chargers
CertiFiber Pro Getting Started Guide
Versiv Product Manuals CD
LinkWare Software CD
5
CertiFiber Pro Fiber Optical Loss Test Set
Users Manual
CFP-Q-ADD Kit
Two CertiFiber Pro Quad Optical Loss Test Set (OLTS) Modules
for tests at 850 nm, 1300 nm, 1310 nm and 1550 nm
Two encircled flux test reference cords (EF-TRCs) for 50 µm/
125 µm fiber, SC/LC
Two test reference cords for 50 µm/125 µm fiber, LC/LC
Two test reference cords for singlemode fiber, SC/LC
Two test reference cords for singlemode fiber, LC/LC
Two LC/LC adapters
Carrying case for the testers
Case for the test reference cords
CertiFiber Pro Getting Started Guide
Versiv Product Manuals CD
6
Chapter 1: Get Acquainted
Safety Information
Safety Information
Table 1 shows the international electrical symbols used on the
tester or in this manual. Symbols for certifications and compliance
are on page 131.
: This key turns the tester on and off.
Table 1. International Electrical Symbols
Warning: Risk of fire, electric shock, or personal injury.
Warning or Caution: Risk of damage or destruction to equipment
or software. See explanations in the manuals.
Warning: Class 1 (OUTPUT port) and Class 2 (VFL port) lasers. Risk of
eye damage from hazardous radiation.
Do not put products containing circuit boards into the garbage.
Dispose of circuit boards in accordance with local regulations.
Warning
To prevent possible fire, electric shock, or personal
injury:
Use only AC adapters approved by Fluke Networks
for use with the tester to supply power to the tester
and charge the battery.
Do not put the battery pack in a fire or an
environment with temperatures more than 140 °F
(60 °C).
Do not use the tester in damp or wet environments.
Do not short-circuit or disassemble the battery pack.
Do not use the tester if it is damaged. Inspect the
tester before use.
Do not open the case; no user-serviceable parts are
inside.
Do not modify the tester.
7
CertiFiber Pro Fiber Optical Loss Test Set
Users Manual
If this equipment is used in a manner not specified
by the manufacturer, the protection provided by the
equipment can possibly be impaired.
Warning: Class 1 and Class 2 Laser Products
To prevent possible eye damage caused by
hazardous radiation:
Do not look directly into optical connectors. Some
optical equipment emits invisible radiation that can
cause permanent damage to your eyes.
Keep the module’s OUTPUT ports covered with a
dust cap or keep a test reference cord attached. The
OUTPUT ports can emit radiation even when you do
not do a test.
Do not run any tests that activate the outputs on
the tester unless a fiber is attached to the output.
When you inspect fiber endfaces, use only
magnification devices that have the correct filters.
Use of controls, adjustments, or procedures not
stated herein can possibly result in hazardous
radiation exposure.
Caution
To prevent damage to the tester or cables under
test and to prevent data loss:
Do not connect the tester to an active network.
Doing so causes unreliable test results, can disrupt
network operations, and can cause damage to the
module’s receiver.
Use proper cleaning procedures to clean all fiber
connectors before every use. Neglecting this step or
using improper procedures can cause unreliable test
results and may permanently damage the
connectors. See Chapter 6.
8
Chapter 1: Get Acquainted
Safety Information
Use a video probe to periodically inspect the
module’s optical connectors for scratches and other
damage.
To make sure your test results are as accurate as
possible, do the reference procedure frequently. See
“About the Reference for Fiber Tests” on page 42.
Use only high-quality test reference cords that
comply with the standards. See “About Test
Reference Cords and Mandrels” on page 44
Connect the AC adapter or replace the battery as
soon as the low battery indication appears.
Keep modules attached to the main and remote
Versiv units to give protection to the module
connectors.
Do not remove the USB flash drive while the LED on
the drive flashes. Doing so can corrupt the data on
the drive.
You can lose a USB flash drive, cause damage to it,
or accidentally erase the contents of the drive. Thus,
Fluke Networks recommends that you save no more
than one day of test results on a flash drive.
9
CertiFiber Pro Fiber Optical Loss Test Set
Users Manual
Connectors, Keys, and LEDs
N
M
A
L
K
J
B
C
D
E
F
O
G
H
I
GPU123.EPS
Figure 1. Main Tester Connectors, Keys, and LEDs (CFP-QUAD module
shown)
LCD display with touchscreen
Singlemode output port with removable connector adapter
and dust cap. This port transmits optical signals for loss and
length measurements.
10
Chapter 1: Get Acquainted
Connectors, Keys, and LEDs
The LED below the output port is red when the port transmits
1310 nm and green for 1550 nm.
Input port with removable connector adapter and dust cap.
This port receives optical signals for loss, length, and power
measurements.
Multimode output port with removable connector adapter and
dust cap. This port transmits optical signals for loss and length
measurements.
The LED below the output port is red when the port transmits
850 nm and green for 1300 nm.
Universal fiber connector (with dust cap) for the visual fault
locator. The connector accepts 2.5 mm ferrules. The LED below
the connector shows the locator’s mode.
Button to manually control the output ports ( and ) and the
visual fault locator (
).
Micro-AB USB port: This USB port lets you connect the tester to a
PC so you can upload test results to the PC and install software
updates in the tester.
Type A USB port: This USB host port lets you save test results on a
USB flash drive or connect a video probe to the tester.
Headset jack
: Starts a test. To start a test, you can also tap TEST on the
display.
: Power key
: Press to go to the home screen.
Connector for the AC adapter. The LED is red when the battery
charges, and green when the battery is fully charged. The LED is
yellow if the battery will not charge. See “Charge the Battery”
on page 18.
RJ45 connector: For functions available in future software
releases.
11
CertiFiber Pro Fiber Optical Loss Test Set
Users Manual
Decal with laser safety
information.
L
A
K
J
I
B
C
D
E
F
M
G
H
Figure 2. Remote Tester Connectors, Keys, and LEDs (CFP-QUAD
module shown)
12
GPU136.EPS
Chapter 1: Get Acquainted
Connectors, Keys, and LEDs
PASS LED comes on when a test passes.
TEST LED comes on during a test.
FAIL LED comes on when a test fails.
TALK LED comes on when the talk function is on.
LOW BATTERY LED comes on when the battery is low.
The LEDs also have these functions:
•Battery gauge (see Figure 4 on page 19)
•Volume indicator for the TALK function
•Progress indicator for software updates
Singlemode output port with removable connector adapter
and dust cap. This port transmits optical signals for loss and
length measurements.
The LED below the output port is red when the port transmits
1310 nm and green for 1550 nm.
Input port with removable connector adapter and dust cap.
This port receives optical signals for loss, length, and power
measurements.
Multimode output port with removable connector adapter and
dust cap. This port transmits optical signals for loss and length
measurements.
The LED below the output port is red when the port transmits
850 nm and green for 1300 nm.
Universal fiber connector (with dust cap) for the visual fault
locator. The connector accepts 2.5 mm ferrules. The LED below
the connector shows the locator’s mode.
Button to manually control the output ports ( and ) and the
visual fault locator (
).
Micro-AB USB port: This USB port lets you connect the tester to a
PC so you can install software updates in the tester.
Headset jack
13
CertiFiber Pro Fiber Optical Loss Test Set
Users Manual
: Starts a test.
: Power key
: Press to use the headset to speak to the person at
the other end of the link. Press again to adjust the volume. To
turn off the talk function, hold down .
Connector for the AC adapter. The LED is red when the battery
charges, and green when the battery is fully charged. The LED is
yellow if the battery will not charge. See “Charge the Battery”
on page 18.
Decal with laser safety
information.
14
Chapter 1: Get Acquainted
A
D
B
E
J
I
C
K
F
LM
G H
The Home Screen for CertiFiber Pro Modules
The Home Screen for CertiFiber Pro Modules
The home screen (Figure 3) shows important test settings. Before
you do a test, make sure these settings are correct.
Figure 3. The Home Screen for CertiFiber Pro Modules
PROJECT: The project contains the settings for a job and helps
you monitor the status of a job. When you save test results, the
tester puts them in the project. Tap the PROJECT panel to edit
the project settings, select a different project, or make a new
project.
GPU117.EPS
15
CertiFiber Pro Fiber Optical Loss Test Set
Users Manual
Shows a summary of the test results in the project:
The number of tests that passed.
The number of tests that failed.
The test setup panel shows the settings the tester will use when
you tap TEST or press .
To change these settings, tap the panel, select the test on the
CHANGE TEST screen, tap EDIT, select different settings on the
TEST SETUP screen, then tap SAVE. See Table 2 on pages 49 and
50.
Note
You can set up tests for any module that the
tester can use, even when no module is attached.
Next ID: The Next ID panel shows the ID that the tester gives to
the next test results you save. For Smart Remote mode, this
panel shows IDs for main tester’s input and output fibers.
Tap Next ID to do these tasks:
Enter an ID, select a different ID in the ID set, select a
different set of IDs, or make a new set. The tester adds the
IDs and ID sets you make to the project that shows on the
home screen.
Turn Auto Save on or off.
Operator: The name of the person who does the job. You can
enter a maximum of 20 operator names.
TOOLS: The TOOLS menu lets you set the reference for fiber
tests, see the status of the tester, and set user preferences such as
the language and the display brightness.
SET REF: Tap SET REF to set the reference and verify your test
reference cords for loss/length tests.
RESULTS: Tap RESULTS to see and manage the results that are
saved in the tester.
16
Chapter 1: Get Acquainted
The Home Screen for CertiFiber Pro Modules
TEST: Tap TEST to do the test shown in the test setup panel.
The percentage of the tests in the project that are completed.
The tester uses the number of available IDs to calculate this
percentage. See Figure 37 on page 116. % Tested does not show
if your project contains only a Next ID list. See “About Next ID
Sets” on page 115 for more information about the Next ID list.
The type of module attached to the tester.
This icon shows when the input and output ports on the
tester’s CertiFiber Pro module are connected to the ports on the
remote’s CertiFiber Pro module and the remote tester is turned
on.
This icon shows when the talk function is on. To use the talk
function:
1Connect the main and remote testers together through a
duplex fiber link.
2Connect headsets to the headset jacks on the testers
3Press the button on one of the headset microphones or
press on the remote, then speak into the
microphone.
17
CertiFiber Pro Fiber Optical Loss Test Set
Users Manual
AC Adapter and Battery
You can use the AC adapter (model VERSIV-ACUN) or the lithium
ion battery (model VERSIV-BATTERY) to supply power to the
tester.
To remove the battery, see “Remove the Battery” on page 128.
Charge the Battery
Before you use the battery for the first time, charge the battery
for about 2 hours with the tester turned off.
To charge the battery
Connect the AC adapter to the tester. See item
LED near the AC adapter connector is red when the battery
charges, and green when the battery is fully charged.
A fully-charged battery operates for approximately 8 hours of
typical use. The battery takes approximately 4 hours to fully
charge when the tester is turned off.
Notes
You do not need to fully discharge the battery
before you recharge it.
The battery will not charge if its temperature is
outside the range of 32 °F to 104 °F (0 °C to 40 °C).
The LED near the connection for the AC adapter is
yellow if the battery will not charge.
in Figure 1. The
Check the Battery Status
On a main tester
The battery status icon is in the upper-left corner of the screen:
Battery is full.
Battery is approximately half full.
18
Chapter 1: Get Acquainted
84 % - 100 %
67 % - 83 %
51 % - 66 %
34 % - 50 %
18 % - 33 %
0 % - 17 %
AC Adapter and Battery
If the AC adapter is not connected, the red bar shows that
the battery is very low. Connect the AC adapter to charge
the battery and make sure the tester continues to operate.
The red bar also shows if the AC adapter is connected, but the
battery is not installed.
On a remote
The LEDs show the battery status at the end of the power-up
sequence, as shown in Figure 4.
GPU102.EPS
Figure 4. LEDs Show the Remote’s Battery Status
19
CertiFiber Pro Fiber Optical Loss Test Set
Users Manual
To see more information about the battery status
1Make the connections shown in Figure 5 and turn on both
testers.
2Tap TOOLS, then tap Battery Status.
When the AC adapter is not connected, the screen shows the
Time Remaining, which is the approximate battery life at the
present rate of use.
Figure 5. Connections to See the Status of the Remote’s Battery
20
GPU134.EPS
Loading...
+ 120 hidden pages