Fluke 902
True-rms HVAC Clamp Meter
Heating, ventilation, air conditioning (HVAC)
technicians require a service tool that can
consistently keep up with their demands.
The Fluke 902 expands the existing line of
quality Fluke clamp meters by delivering the
features necessary to diagnose and repair
HVAC systems. Combined with True RMS
technology and a CAT III 600 V rating, the
Fluke 902 helps technicians do their jobs
safely and accurately.
Use the Fluke 902 to:
Capture flue gas temperatures
•
Conduct flame rod testing
•
Measure start and run motor capacitors
•
Measure performance of variable frequency drives
•
Technical Data
Features include:
Capacitance
•
DC current to 200 uA
•
Contact temperature (K-type thermocouple)
•
True-rms
•
Min/Max
•
Hold
•
Specifications
Feature Range Accuracy
Voltage dc 0 to 600.0 V 1 % ± 5 counts
Voltage ac
(true-rms)
Current ac
(true-rms)
Current dc 0 to 200.0 µA 1.0 % ± 5 counts
Resistance
Continuity
Temperature*
(Type-K
thermocouple)
Capacitance 1 µF to 1000 µF 1.9 % ± 2 counts
Warranty Three-years
*Error does not include Type-K thermocouple errors
0 to 600.0 V 1 % ± 5 counts (50/60 Hz)
0 to 600.0 A 2.0 % ± 5 counts (50/60 Hz)
0 to 9999
-10 °C to 400 °C
(-14 °F to 752 °F)
-40 °C to -10 °C
(-40 °F to -14 °F)
W
<= 30
1.5 % ± 5 counts
W
± 1.0 % + 0.8 °C
(± 1.0 % + 1.5 °F) typical
± 5.0 % + 1.5 °C
(± 5.0 % + 3.3 °F) typical
Ordering Information
Fluke-902 HVAC Clamp Meter
Included
AA alkaline batteries (2)
Users manual (w/safety information)
Soft carrying case
TL75 Test Leads (1 pair)
80BK Integrated DMM Temperature
Probe (1)
Optional accessories
H3 Clamp Meter Holster
Rugged fabric holster includes
•
flap for lead storage and built-in
belt loop
Also used on Fluke 320 and
•
330 Series Clamp Meters
80PK-8 Pipe Clamp Probe
(for use with 80AK)
Clamps securely to pipe from
•
6.4 mm to 34.9 mm
(.25 in to 1.375 in)
Temperature range: -29 °C to
•
149 °C (-20 °F to 300 °F)
Probe material: K-type sensor
•
with pvc body
Cable length: 1 m (39 in)
•
TL223 SureGrip™ Electrical
Test Lead Set
Starter kit for electrical
•
applications
TP1 has flat blades for wall
•
sockets
Includes 1 pair: AC220, TP1,
•
TL224
CAT III 1000 V, CAT IV 600 V,
•
10 A
80AK Thermocouple Adapter
Adapts Type-K thermocouple
•
mini-connector to dual banana
plug inputs
Measurement range and accu-
•
racy is not affected by the 80AK
adapter
Fluke. Keeping your world
up and running.™
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2006 Fluke Corporation. All rights reserved.
Printed in U.S.A. 10/2006 2645797 D-EN-N Rev B
2 Fluke Corporation 902 True-rms HVAC Clamp Meter