Fluke 77 IV Data Sheet

Fluke 77IV
N10140
Digital Multimeter
Versatile meters for field service or bench repair
The NEW Fluke 77-IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke’s original 70 Series with more measurement func­tions, conformance to the latest safety standards, and a much larger display that’s easier to view.
It measures:
Wide 1000 V measurement range
Average responding ac measurements
0.3 % accuracy
Frequency and capacitance
Resistance and continuity
Technical Data
General specifications
Accuracy is specified for 1 year after calibration, at operating tempera­tures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Counts ]).
Maximum voltage between any terminal and earth ground
Surge protection 8 kV peak per IEC 61010
W Fuse for mA input W Fuse for A input
Display Digital: 6,000 counts, updates 4/sec Bar graph 33 segments, updates 32/sec Frequency 10,000 counts Capacitance 1,000 counts Operating altitude 2,000 meters Storage altitude 12,000 meters Operating temperature -10 °C to + 50 °C Storage temperature -40 °C to + 60 °C Temperature coefficient 0.1 X (specified accuracy/°C (< 18 °C or > 28 °C) Electromagnetic compatibility
(EN 61326-1:1997)
Relative humidity (maximum non-condensing)
Battery life 400 hours typical (Alkaline) Size (H x W x L) 4.3 cm x 9 cm x 18.5 cm Weight 420 g Safety compliance ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC
Certifications
1000 V
440 mA, 1000 V FAST Fuse 11 A, 1000 V FAST Fuse
In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ± 5 °C (9 °F)
90 % to 35 °C; 75 % to 40 °C; 45 % to 50 °C
61010 to 1000 V Measurement Category III, 600 V Measurement Category IV
CSA, TÜV (EN61010), UL,
, (N10140), VDE
Function Range Resolution Accuracy ± ([% of reading] + [counts])
AC volts (average responding)
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
2.0 % + 2 (45 Hz to 1 kHz)
1000 V 1 V
DC mV 600.0 mV 0.1 mV 0.3 % + 1
DC volts 6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
0.3 % + 1
1000 V 1 V
Continuity 600 W 1 W Meter beeps at < 25 W, beeper turns off at
> 250
W; detects opens or shorts of 250 µs
or longer.
Ohms 600.0 W 0.1W 0.5 % + 2
W 0.001 kW
6.000 k
W 0.01 kW
60.00 k
W 0.1 kW
600.0 k
W 0.001 MW
6.000 M
W 0.01 MW 2.0 % + 2
50.00 M
0.5 % + 1
Diode test 2.400 V 0.001 V 1 % + 2
Capacitance 1000 nF 1 nF
1.2 % + 210.00 µF 0.01 µF
100.0 µF 0.1 µF
AC amps (average responding)
1
9999 µF
60.00 mA 0.01 mA
400.0 mA
3
1 µF 10 % typical
0.1 mA
2.5 % + 2 (45 Hz to 1 kHz)
6.000 A 0.001 A
3
DC amps
2,5
Hz (ac voltage input)
4
10.00 A
60.00 mA 0.01 mA
400.0 mA
4
6.000 A 0.001 A
5
10.00 A
99.99 Hz 0.01 Hz
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
0.01 A
0.1 mA
0.01 A
1.5 % + 2
0.1 % + 1
99.99 kHz 0.01 kHz
MIN MAX AVG For dc functions, accuracy is the specified accuracy of the measurement function
(12 counts for changes longer than 275 ms in duration. For ac functions, accuracy is the specified accuracy of the measurement function (40 counts for changes longer than 1.2 s in duration.
1 In the 9999 (F range for measurements to 1000 (F, the measurement accuracy is 1.2 % + 2. 2 Amps input burden voltage (typical): 400 mA input 2 mV/mA, 10 A input 37 mV/A. 3 400.0 mA accuracy specified up to 600 mA overload. 4 >10 A unspecified. 5 Frequency is specified from 2 Hz to 99.99 kHz. Below 2 Hz, the display shows zero Hz.
2 Fluke Corporation 77IV Digital Multimeter
Ordering information
Fluke-77-4 Digital Multimeter
Included
TL75 Test leads, user’s manual and 9 V battery (installed).
Fluke. Keeping your world up and running.
Fluke Corporation PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2006 Fluke Corporation. All rights reserved. Specifications subject to change without notice. Printed in U.S.A. 12/2006 2805740 D-EN-N Rev A
Loading...