Fluke 714 Data sheet

Page 1
714
Thermocouple Calibrator
Instruction Sheet

Introduction

Your calibrator is supplied with a Flex-Stand holster, an installed 9 V alkaline battery, and this instruction sheet. Sets of thermocouple miniplugs are available from Fluke. (Accessories Fluke-700TC1 and Fluke-700TC2 TC Miniplug Kits.)
If the calibrator is damaged or something is missing, contact the place of purchase immediately. Contact your Fluke distributor for information about accessories. To order replacement parts or
spares, see “Replacement Parts.” The following tables list the thermocouple types supported by the
calibrator, the standards and scales used for each type, the thermocouple properties, and calibrator resolution. Full calibrator specifications are listed at the end of this instruction sheet.
Note
Since mV input and output units are available, you can use the calibrator for any thermocouple type by making manual calculations or referring to tables.
®
PN 650306 July 1997 Rev. 1, 10/97 1997 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective compani es.
Page 2
Thermocouple Standards and Scales
Thermocouple Type Standard Scale
J, K, T, E, R, S, B NIST 175 ITS-90 L (J-DIN), U (T-DIN) DIN 43710 IPTS-68
Thermocouple Properties
Thermocouple
Type
Temperature
Ranges
Display Resolution
J -200 to 1200°C,
-328 to 2192°F
K -200 to 1370°C
-328 to 2498°F
T -200 to 400°C
-328 to 752°F
E -200 to 950°C
-328 to 1742°F
R -20 to 1750°C
-4 to 3182°F
S -20 to 1750°C
-4 to 3182°F
B 600 to 1800°C
1112 to 3272°F
L -200 t o 900°C
-328 to 1652°F
U -200 to 600°C
-328 to 1112°F
0.1°C or °F
0.1°C or °F
0.1°C or °F
0.1°C or °F
1°C or °F
1°C or °F
1°C or °F
0.1°C or °F
0.1°C or °F
Page 3
Millivolt Range and Resolution
Mode Range Display Resolution
mV -10 to 75 mV 0.01 mV

Explanation of International Symbols

The following symbols are used on the calibrator or in this instruction sheet. The table below explains their meaning.
International Sy mbols
Symbol Meaning
J
I
Earth ground Fuse
M
W
T
P
Battery Refer to this instruction sheet for information about
this feature. Double insulated
Conforms to relevant Canadian Standards Association directives.
Conforms to European Union directives
Page 4

Safety Information

W Warning
To avoid possible electric shock or personal injury:
Never apply more than 30 V between the TC
terminals, or between either TC terminal and earth ground.
Make sure the battery door is closed and
latched before you operate the calibrator.
Remove an attached thermocouple miniplug
from the calibrator before you open the battery door.
Do not operate the calibrator if it is damaged.
Do not operate the calibrator around explosive
gas, vapor, or dust.
When servicing the calibrator, use only specified replacement parts.

Turning the Calibrator On

Press the green O pushbutton to turn the calibrator on and off.
Page 5

Measuring a Thermocouple

INPUT
Shows TC type selected
THERMOCOUPLE
714
CALIBRATOR
Press to select TC type or mV
Press so that INPUT is on the display
TC wire and miniplug of same type as selected
MAX
Press to toggle °C or °F
30V
TC
ke01f.eps
Page 6

Simulating a Thermocouple

OUTPUT
Shows TC type selected
THERMOCOUPLE
714
CALIBRATOR
Press to select TC type or mV
Press so that OUTPUT is on the display
Press to step up/down 50° (or 10 mV)
TC wire and miniplug of same type as selected
MAX
Press to toggle °C or °F
Press to scroll up/down 0.1° (or 0.01 mV). Hold down to
30V
TC
scroll faster
ke02f.eps
Page 7

Maintenance

For maintenance procedures not described in this sheet, contact a Fluke Service Center.

In Case of Difficulty

Check the battery and thermocouple test wiring. Replace as necessary.
Review this sheet to make sure you are using the calibrator correctly.
If the calibrator needs repair, contact a Fluke Service Center. If the calibrator is under warranty, see the warranty statement for terms. If the warranty has lapsed, the calibrator will be repaired and returned for a fixed fee. Contact a Fluke Service Center for information and price.

Cleaning

Periodically wipe the case with a damp cloth and detergent; do not use abrasives or solvents.

Calibration

Calibrate your calibrator once a year to ensure that it performs according to its specifications. A calibration manual is available (PN 686540). Call 1-800-526-4731 from the USA and Canada. In other countries, contact a Fluke Service Center.

Replacing the Battery

When the M symbol appears on the display, replace the battery with a 9 V alkaline battery.
Page 8

Replacing the Fuse

! Warning
To avoid personal injury or damage to the calibrator, use only a 0.125A 250V fast fuse, Littelfuse
Fuse F1 is probably blown if in the input mode, the calibrator always reads OL, even with a thermocouple connected.
®
2AG.
it07f.eps
Page 9
Replace the fuse as follows:
1. Remove the test leads and turn the calibrator off.
2. Remove the battery door.
3. Remove the three Phillips-head screws from the case bottom and turn the case over.
4. Gently lift the top cover from the end nearest the input/output terminals until it unsnaps from the bottom cover.
5. Replace the fuse with a 0.125 A 250 V fast fuse, Littelfuse
®
2AG.
6. Fit the top and bottom covers together, engaging the two snaps. Make sure that the gasket is properly seated. Reinstall the three screws.
7. Replace the battery door.
Page 10
F1
Snaps
ke03f.eps
Page 11

Replacement Parts and Accessories

Replacement Parts
Item Description PN or
Model
no.
Qty.
BT1 9V battery, ANSI/NEDA 1604A or
IEC 6LR61
CG81Y Holster, Yellow CG81Y 1
!
F1 Fuse, 125 mA, 250V fast 686527 1
MP85 Case top 620234 1 MP86 Case bottom 620168 1 H2, 3, 4 Case screw 832246 3 MP89, 90 Non-skid foot 824466 2 MP92 Battery door 619947 1 H5, 6 Battery door fasteners 948609 2 S1 Keypad 687076 1
714 Instruction Sheet 560306 1
71X Series Calibration Manual 686540 Option
614487 1
Page 12
MP86
H2, 3, 4
H5, 6
MP85
S1
F1
BT1
MP89, 90
MP92
Instruction
Sheet
Holster
ke04c.eps
Page 13

Specifications

Specifications are based on a one year calibration cycle and apply for ambient temperature from +18°C to +28°C unless
stated otherwise. “Counts” means number of increments or decrements of the least significant digit.
Temperature Measure and Thermocouple Simulate
TC Type Resolution Error Reference
J, K, T, E, L, U 0.1°C or °F ±(0.3°C + 10 µV) ±0.2°C B, R, S 1°C or °F ±(0.3°C + 10 µV) ±0.2°C
Maximum input voltage: 30 V
Junction
Error
Millivolt Measure and Source
Range Resolution Accuracy
-10 mV to 75 mV 0.01 mV ±(0.025% + 1 count)
Maximum input voltage: 30 V
Page 14
General Specifications
Maximum voltage applied between any terminal and earth ground or between any two terminals: 30 V
Storage temperature: -40°C to 60°C Operating temperature: -10°C to 55°C Operating altitude: 3000 meters maximum Temperature coefficient: 0.05 x specified accuracy per °C for
temperature ranges -10°C to 18°C and 28°C to 55°C Relative humidity: 95% up to 30°C, 75% up to 40°C, 45% up to
50°C, and 35% up to 55°C
Vibration: Random 2 g, 5 Hz to 500 Hz Shock: 1 meter drop test Safety: Certified as compliant to CAN/CSA C22.2 No.
1010.1:1992. Complies with ANSI/ISA S82.01-1994.
Power requirements: Single 9 V battery (ANSI/NEDA 1604A or IEC 6LR61)
Size: 32 mm H x 87 mm W x 187 mm L (1.25 in H x 3.41 in W x
7.35 in L);
With holster and Flex-Stand: 52 mm H x 98 mm W x 201 mm L (2.06 in H x 3.86 in W x 7.93 in L)
Weight: 332 g (11.7 oz); With holster and Flex-Stand: 584 g (20.6 oz)
Page 15

How to Contact Fluke

To order accessories, receive operating assistance, or get the location of the nearest Fluke distributor or Service Center, call:
1-800-44FLUKE (1-800-443-5853) in U.S.A. and Canada +31-402-678-200 in Europe +1-425-356-5500 from other countries Address correspondence to:
Fluke Corporation Fluke Europe B.V. P.O. Box 9090, P.O. Box 1186, Everett, WA 98206-9090 5602 BD Eindhoven U.S.A. The Netherlands
Visit us on the World Wide Web at: www.fluke.com
LIMITED WARRANTY & LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse or abnormal conditions of operation or handling. Resellers are not
authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, send your defective cali brator to the nearest Fluke Authorized Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDE NTAL OR CONSEQ UE NTIA L DAM AGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitat i on of an implied warranty or of incidental or consequential damages, this limit ati on of liability may not apply to you.
Loading...