566, 568 and 568Ex Multipurpose Thermometers
Fluke 566
Fluke 568
Fluke 568 Ex
Choose your language |
Select the measurement |
|
surface |
See complete measurement details in seconds
Included accessories
FlukeView® Forms software (568 only), USB cable (568 only), K-type thermocouple bead probe, 2 AA batteries, hard carrying case, quick start guide, and users manual.
Ordering information
Fluke 566 |
Infrared thermometer |
Fluke 568 |
Infrared thermometer |
Fluke 568 Ex |
Intrinsically safe infrared |
|
thermometer |
The two-in-one infrared and contact thermometer with an innovative graphical display
With a straight-forward, menu-driven user interface and graphical display, the Fluke 566 and 568 multipurpose thermometers make even complex
temperature measurements easy. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button. For added convenience, both rugged handheld thermometers combine contact and non-contact temperature measurement capability, providing a total temperature measurement solution for any service and maintenance program.
•Easily access advanced features with the soft-key buttons and graphical display
•Measure smaller targets from farther away using the IR thermometer
•Adjustable emissivity and built-in table of common materials for higher IR accuracy
•Quickly identify problems with the MIN, MAX, AVG, and DIF functions
•2-color flashing alarm alerts you visually when measurements exceed limits
•Includes Type K thermocouple bead probe
•Compatible with all standard miniconnector K-type thermocouples
•Data logging with a date/time stamp
•Soft rubber boot for increased ruggedness
•User interface available in 6 languages
The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world.
Specifications
(Check the Fluke web for detailed specifications)
|
566 |
|
568/568 Ex |
Infrared temperature range |
-40 °C to 650 °C |
|
-40 °C to 800 °C |
Infrared accuracy |
< 0 °C : ± (1.0 °C + 0.1°/1 °C); |
||
|
> 0 °C : ± 1 % or ± 1.0 °C, whichever is greater |
||
Display resolution |
|
0.1 °C |
|
Infrared spectral response |
|
8 μm to 14 μm |
|
Infrared response time |
|
< 500 msec |
|
Input temperature range |
|
-270 °C to 1372 °C |
|
Input accuracy |
-270 °C to -40 °C: ± (1 °C + 0.2 °/1 °C) |
||
|
-40 °C to 1372 °C: ± 1 % or 1 °C, whichever is greater |
||
D:S (Distance to measurement spot size) |
30:1 |
|
50:1 |
Laser sighting |
Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm |
||
Minimum spot size |
|
19 mm |
|
Emissivity adjustment |
By built-in table of common materials or digitally adjustable |
||
|
|
from 0.10 to 1.00 by 0.01 |
|
Data logging with Date/Time stamp |
20 points |
|
99 points |
PC interface and cable |
None |
|
USB 2.0 with FlukeView® |
|
|
|
Forms software |
Hi/Low alarms |
Audible and two-color visual |
||
Min/Max/Avg/Dif |
|
Yes |
|
Display |
Dot matrix 98 x 96 pixels with function menus |
||
Backlight |
Two levels, normal and extra bright for darker environments |
||
Trigger Lock |
|
Yes |
|
Switchable between Celsius and Fahrenheit |
|
Yes |
Power: 2 AA/LR6 Batteries (566); 2 AA/LR6 |
Size (HxLxW): 254 x 191 x 69 mm |
|
|||
Batteries and USB for use with a PC (568) |
Operating temperature: 0 °C to 50 °C |
||||
Battery life: Used continuously; laser and |
Storage temperature: -20 °C to 60 °C |
||||
backlight on: 12 hours (568 Ex 4 hours); |
Safety rating Zone 1 and 2 IECEx EPS 13.0006X |
||||
laser and backlight off: 100 hours |
|
Ex ia IIC T4 Gb 568 Ex |
|
||
Weight: 0.965 kg (566); 1.026 kg (568) |
Two years warranty |
|
|||
|
|
|
Recommended Accessories |
||
|
|
|
|
|
|
H6 |
80PK-8 |
80PK-9 |
80PK-11 |
80PK-25 |
80PK-26 |
See page 153 |
See page 150 |
See page 150 |
See page 150 |
See page 150 |
See page 150 |