The 5500A/LEADS and 5520A-525A/ LEADS are professional quality lead sets that ensure you always have the right probes and connectors for the job at hand. These top quality leads provide years of service and are designed to mini­mize connection loss and thermal effects. Each test lead has silicon insulation for easy handling and is rated at 1000 V. In
5500A/LEADS
The 5500A/LEADS set is designed for use on the 55XX Series Multi-Product Calibrators.
Parts included in the 5500A/LEADS test lead set
Qty Description
1 Soft case, 3 compartment, 304 mm x 254 mm x 63 mm (12 in x 10 in x 2.5 in) with carrying strap 1 Soft case, 165 mm x 279 mm x 63 mm (6.5 in x 11 in x 2.5 in) 1 Stackable test lead, 100 cm, black 1 Stackable test lead, 100 cm, red 1 Stackable test lead, 100 cm, white 1 Stackable test lead, 100 cm, yellow 1 T/C assembly, K-type, beaded, molded plug 1 T/C assembly, J-type, beaded, molded plug 1 T/C, molded-plug, copper shorting 1 Thermocouple adapter 80PK xx mini T/C to banana 1 Thermocouple extension, 3 feet (1 m), B 1 Thermocouple extension, 3 feet (1 m), E 1 Thermocouple extension, 3 feet (1 m), J 1 Thermocouple extension, 3 feet (1 m), K 1 Thermocouple extension, 3 feet (1 m), N 1 Thermocouple extension, 3 feet (1 m), R 1 Thermocouple extension, 3 feet (1 m), S 1 Thermocouple extension, 3 feet (1 m), T 1 Thermocouple extension, 3 feet (1 m), CU 2 Dual binding post adapters, banana plug 2 High current, 30 A, test lead, red and black 2 Shielded calibration test leads, 24 in., banana plug
addition to the test leads, each Fluke lead set contains a full set of thermocouple extension wires with mini-thermocouple connectors on each end for fast, trouble­free calibration of thermocouple instru­ments. Each Fluke lead set comes with a soft carrying pouch for convenient trans­porting and storage.
One-year warranty Shielded calibration leads
Cat I, 1000 V
Rated current, 2.5 A
Thermocouple extensions
16 Ga
Teflon jacket
Standard limits of error
Stackable test leads
Cat II, 1000 V
Rated current 20 A
Hi current test leads
Rated voltage 30 V ac or
60 V dc max
Rated current 30 A max
5520A-525A/LEADS
This lead set is ideally suited for the 525B Temperature/Pressure Calibrator. It includes all thermocouple type extensions used on the 525B, terminated with male-to-male mini connectors on both ends for easy calibration hookups. This lead set is also suitable for the 55XX Series Multi-Product Calibrator.
Parts included in the 5520A-525A/LEADS test lead set
Qty Description
1 Soft case, 6.5 x 11 x 2.5 in. (165 x 279 x 63 mm) 1 T/C assembly, K-Type, beaded, molded plug 1 T/C assembly, J-Type, beaded, molded plug 1 T/C, molded-plug, copper shorting 1 Thermocouple adapter, K, banana (80AK) 1 Thermocouple extension, 3 feet (1 m), B 1 Thermocouple extension, 3 feet (1 m), E 1 Thermocouple extension, 3 feet (1 m), J 1 Thermocouple extension, 3 feet (1 m), K 1 Thermocouple extension, 3 feet (1 m), N 1 Thermocouple extension, 3 feet (1 m), R 1 Thermocouple extension, 3 feet (1 m), S 1 Thermocouple extension, 3 feet (1 m), T 1 Thermocouple extension, 3 feet (1 m), CU 2 Dual binding post adapters, banana plug 2 High current, 30 A, test lead, red and black 2 Shielded calibration test leads, 24 in., banana plug
Fluke Calibration.
Precision, performance, confidence.
One-year warranty Shielded calibration test leads
Cat I,1000 V
Rated current, 2.5 A
Thermocouple extensions
16 Ga
Teflon jacket
Standard limits of error
Hi current test leads
Rated voltage 30 V ac or 60 V dc max
Rated current 30 A max
2 Fluke Calibration 5500A/Leads and 5520A-525A/Leads Test Lead Sets
Fluke Calibration PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.flukecal.com
©2004-2013 Fluke Calibration. Specifications subject to change without notice. Printed in U.S.A. 3/2013 1626792D_EN
Modification of this document is not permitted without written permission from Fluke Calibration.
Loading...