Fluke 3125 Specifications

Surface Probe Calibrator
Features
400°C
Uses Hart 2200 Controller for
excellent accuracy and stability
NIST-traceable calibration
included
Surface probes are difficult to calibrate because it’s hard to find a flat, heated surface that’s stable and uniform. Hart Scientific’s Model 3125 Surface Dry-Well takes advantage of Hart’s proprietary 2200 Temperature Controller and gives you the best possible conditions for calibrating surface sensors.
Why buy a non-temperature calibration device designed for test tube sterilization or PC board repair when you can have a true calibration instrument? The Hart Scientific Model 3125 Surfac e Dry-Well has a uniform surface temperature and reaches temperatures as high as 40 0°C.
The test surface is milled aluminum for an absolutely smooth and true calibration work area with maximum thermal conductivity. The 12.25-square-inch test surface is large enough to calibrate more than one sensor at a time. The Hart Scientific 3125 can be used with a reference surface sensor or PRT. PRTs (3/16" diameter) may be inserted through a drilled hole into the center of the block for use as reference thermometers or for easy recalibration of the unit’s display.
With an accuracy of ±0.5 °C to 200 °C and ±1 °C to 400 °C, you can calibrate almost any surface probe, thermistor, thin film sensor, RTD, thermocouple, ribbon sensor, or surface mount cutouts, fuses, and switches. Stability is within ±0.3 °C at 400 °C and uniformity within the center three inches of the surface is ±0.6 °C at 200 °C.
Don’t buy “make-do” hot plates when you can have a legitimate calibration tool.
PO Box 1073, 8 Leroy Road, Williston, VT 05495 USA • fax 802-863-1193 • ph 802-863-0085 • toll free 800-235-8367
Ordering Information
3125
Surface Calibrator, (includes detachable Hart Model 2200 Controller)
Specifications
Temperature Range 35 °C to 400 °C
Display Accuracy ±0.5 °C to 200 °C
Stability ±0.2 °C to 300 °C
Resolution 0.01 ° Uniformity ±0.3 °C at 100 °C
Heating Time 25 °C to 400 °C: 22 minutes Cooling Time 400 °C to 100 °C: 65 minutes Stabilization Time 8 minutes Controller Hart Model 2200, microprocessor based, with RS-232 Readout °C or °F, switchable Sensor Heater 325-watt, solid-state controlled Surface Plate 6061 aluminum; top surface machine finished to 0.0008 mm (0.000032 in),
Power 115 VAC (±10 %), 2.8 A or 230 VAC (±10 %), 1.4 A, specify, 50/60 Hz, 325
Weight 3.2 kg (7 lb.) with 2200 Controller NIST-Traceable
Calibration
(95 °F to 752 °F)
±1.0 °C to 400 °C
±0.3 °C to 400 °C
±0.6 °C at 200 °C ±0.9 °C at 300 °C ±1.4 °C at 400 °C
RTD, 100
96 mm (3.8 in) diameter acc essible
W
Data at 50 °C, 120 °C, 190 °C, 260 °C, 330 °C, and 400 °C
Ω
PO Box 1073, 8 Leroy Road, Williston, VT 05495 USA • fax 802-863-1193 • ph 802-863-0085 • toll free 800-235-8367
Loading...