Fluke 3000 FC Series Technical Data

Fluke 3000 FC
Series Test Tools
Now compatible with Fluke
Technical Data
Connect
™ Mobile App
Start building tomorrow’s test tool system today with the Fluke 3000 FC Digital Multimeter.
The new Fluke Connect system of test tools communicates with the new Fluke Connect mobile app on your Android™ or iOS smart device, allowing you to share live measurements, monitor readings from safe distances, and get your job done easier than ever before. The wireless digital multimeter functions as the mobile hub, displaying readings from up to three meter modules tools simultaneously from up to 20 meters away. The Fluke Connect meters also give you the flexibility to build your wireless test tool system how you want when you want.
Fluke 3000 FC Test Tools (Not compatible with Fluke CNX test tools)
Wireless Digital Multimeter
iFlex True-rms AC Current Clamp Meter
True-rms AC Current Clamp Meter
AC Voltage Meter
K-Type Temperature Meter
AC/DC Current Clamp Meter Module
2000 A DC Current Clamp Meter
4-20 mA DC Current Clamp Meter
DC Voltage Meter
PC Adapter
Productivity
Communicate with your iOS (4s and later) and Android™ (4.3 and up) devices with the new Fluke Connect mobile app
Wireless technology allows connectivity between your phone, PC, and all Fluke Connect enabled test tools
Let your team see what you see in an instant with ShareLive™ video call
Save money and time by taking multiple measure­ments simultaneously
Isolate intermittent events or record signal fluc­tuations without even being there using the log function on the meters
Built with
See it. Save it. Share it. All the facts, right in the field.
Fluke Connect with ShareLive™ is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is available for Android™ (4.3 and up) and iOS (4s and later) and works with over 20 different Fluke products—the largest suite of connected test tools in the world. And more are on the way. Go to the Fluke website to find out more.
Make the best decisions faster than ever before by viewing all temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Download the app at:
Smart phone not included with purchase.
Productivity (continued)
View results on your computer with the PC Adapter
k with fewer interruptions by recording multiple
Wor sessions before downloading. Data is saved to a PC in .csv format (comma separated variable) file format for easy viewing at your convenience
Capture readings a recording intervals from one second to one hour
Future proof your investment by adding functionality to the 3000 FC DMM when you need it
t different intervals, with user-set
Convenience
Send and communicate test data to your manager and coworkers to assess abnormal system response in seconds
Have all asset
downloading to your PC for future asset performance tracking and reliability programs
See multiple measurements on one screen
a
t one time (DMM and three meter modules,
Ti200/300/400 and five meter modules) No more writing da
sets of min/max/avg readings over single or multiple logging sessions using the recording capability. Each reading and session is time stamped
test results at your fingertips after
ta down. Capture up to 65,000
Av
oid awkward or uncomfortable measurement posi­tions. Set up the measurement once, step back and read it as many times as you want, when you want
View up to 6 live readings at once on the Fluke Connect mobile app or a PC to get a complete understanding of the situation
Easily see backlit
environments Choose auto or
Use the optional TP
more hands-free working Int
egrated holster protects the meters, while probe
holders keep accessories organized
displays in dark or dimly lit work
manual ranging
ak Magnetic Hanger for even
Safety
Be in multiple places at once, reducing the risk of arc flash by separating yourself from hazardous measurement situations
Fluke 3000 FC meets Measurement CAT III and Category IV 600 V safety standards: AC Current Clamp Meter and AC/DC Current Clamp Meter Module 600 V CAT III; AC Voltage Meter, DC Voltage Meter, and iFlex Clamp Meters 600 V CAT IV/1000 CAT III
Category 1000 V
(RF connection time (binding time) can take up to 1 minute.)
2 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
General specifications
Fluke 3000 FC Series Wireless Multimeter
Detailed specifications (Not compatible with Fluke CNX test tools)
For all specifications: accuracy is specified for one year after calibration, at operating temper­atures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
AC voltage
1
Range
Resolution
45Hz to 500Hz 500Hz to 1kHz
600.0mV 0.1mV
6.000V 0.001V
Accuracy
60.00V 0.01V
1.0% + 3 2.0% + 3
600.0V 0.1V 1000V 1V
1
All ac voltage ranges are specified from 1% of range to 100% of range.
2
Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor < 1.5 at 1000V.
3
For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4
Do not exceed 107 V-Hz.
DC voltage, continuity, resistance, diode test and capacitance
Function Range Resolution Accuracy
mV 600.0mV 0.1mV 0.09% + 2 V 6.000V 0.001V
0.09% + 260.00V 0.01V
600.0V 0.1V 1000V 1V 0.15% + 2
600Ω 1Ω Meter beeps at < 25Ω, beeper detects opens or shorts
600.0Ω 0.1Ω 0.5% + 2
6.000kΩ 0.001kΩ
60.00kΩ 0.01kΩ
60.00kΩ 0.1kΩ
600.0kΩ 0.001MΩ
50.00MΩ 0.01MΩ 1.5% + 3 Diode test 2.000V 0.001V 1% + 2 µF 1000nF 1nF
100.0μF 0.1μF
1
1
In the 9999μF range for measurements to 1000μF, the measurement accuracy is 1.2% + 2.
9999μF
1μF 10% typical
of 250μs or longer.
0.5% + 1
1.2% + 210.00μF 0.01μF
2,3,4
Contents
AC and DC current
Function Range
mA AC (45Hz to 1kHZ)
2
mA DC
1
All ac current ranges are specified from 5% of range to 100% of range.
2
Input burden voltage (typical): 400mA input 2mV/mA.
3
400.0 mA accuracy specified up to 600mA overload.
3 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
1
Resolution Accuracy
60.00mA 0.01mA
400.0mA
3
0.1mA
60.00mA 0.01mA
400.0mA
3
0.1mA
1.5% + 3
0.5% + 3
Frequency
Range Resolution Accuracy
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 0.001kHz
99.99kHz 0.01kHz
1
Frequency is specified up to 99.99kHz in volts and up to 10kHz in amps.
0.1% + 1
[1]
Input characteristics
Function
Protection
1100 V rms > 10 MΩ < 100 pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V rms > 10 MΩ < 100 pF > 60 dB, dc to 60 Hz
1100 V rms > 10 MΩ < 100 pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V rms < 2.7 V dc < 0.7 V dc < 0.9 V dc < 350 mA 1100 V rms < 2.7 V dc 2.000 V dc < 1.1 mA
Function Overload Protection Overload
mA Fused, 44/100A, 1000V FAST Fuse 600mA overload for 2minutes maximum, 10minutes rest minimum
Overload
Input Impedance
(nominal) Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
Open circuit test voltage
Full scale voltage
To 6 MΩ 50 MΩ
Typical short circuit current
MIN/MAX recording
Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration. AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.
General specifications (Not compatible with Fluke CNX test tools)
Maximum voltage between any terminal and earth ground
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate: 4/sec
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6 Battery life 250 hours minimum RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed: Up to 20m
Temperature Operating: -10 °C to 50 °C
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35°C to 40°C), 0% to 45% (40°C to 50°C) Altitude Operating: 2,000 m
Electromagnetic compatibilty EMI, RFI, EMC, RF
Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3
Certifications cCSAus, FCC, CE Ingress Protection (IP) rating IP54 Pollution Degree 2 Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) Weight 340 g (12 oz)
1000 V dc or ac rms
Votls, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts
Obstructed, sheetrock wall: Up to 6.5m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
Storage: -40 °C to 60 °C
Storage: 12,000 m EN 61326-1:2013, EN 61326-2-2:2013. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
rd
edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010
4 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3000 FC Wireless AC Current Clamp Meter
A fully functional true-rms current clamp meter that wirelessly relays measurements to other Fluke Connect
enabled master units, listed
below.
Fluke 3000 FC DMM
Fluke TiX560/520 Infrared Camera
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
a3000 FC main features include:
True-rms ac clamp meter
Measure up to 400 A ac
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
Inrush function
a3000 FC general specifications
Range 0.5 A to 400.0 A Resolution 0.1A Accuracy 400.0 A: 2% ± 5 digits (10Hz to 100Hz), 2.5% ± 5 digits
Inrush Max displayed reading: 999.9A Crest factor (50Hz/60Hz) 3 at 500A, 2.5 at 600A, 1.42 at 1000A, add 2% for C.F. > 2 LCD w/backlight 3½ digits Log rate/interval 1 sec minimum/adjustable by PC Battery type 2 AA, NEDA 15A, IEC LR6 Battery life 400 hours Memory Record up to 65,000 readings RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed: Up to 20 m
Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Temperature coefficient Add 0.1x (specified accuracy)/°C (< 18°C or > 28°C) Operating humidity 90% at 35°C, 75% at 40°C, 45% at 50°C Altitude Operating: 2,000 m
EMC EN 61326-1:2013 Safety compliance IEC 61010-1, CAT III 600 V, CAT IV 300 V, 3rd edition Safety rating CAT III 600 V, CAT IV 300 V Certifications cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP30 Pollution Degree 2 Jaw opening 34 mm (1.33 in) Size (HxWxD) 20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in) Weight .22 kg (8 oz)
(100Hz to 500Hz)
Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Storage: 12,000 m
(Not compatible with Fluke CNX test tools)
5 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3001 FC Wireless iFlex AC Current Meter
A true-rms current clamp meter that wirelessly relays measurements to other Fluke Connect master units, listed below.
Fluke 3000 FC DMM
Fluke TiX560/520 Infrared Camera
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
The iFlex™ Wireless Current Meter allows you to mea­sure around awkward sized conductors or get into tight spaces and makes wire access easier.
Contains: One true-rms flexible current meter and
one iFlex i2500-10 Flexible Current Probe
Measure up to 2500 A ac
Use as a standalone meter or as part of the system
Logging function for recording and saving up to
65,000 readings
Inrush function
Magnetic hanging strap
enabled
a3001 FC general specifications
Range 0.5 A to 2500 A AC Resolution 0.1 A Accuracy 3% ± 5 digits (5 Hz to 500 Hz) Crest factor (50Hz/60Hz) 3.0 at 1100A, 2.5 at 1400A, 1.42 at 2500A, add 2% for C.F. > 2 LCD w/backlight 3½ digits Log rate/interval 1 sec minimum/adjustable by PC or front panel Battery type 2 AA, NEDA 15A, IEC LR6 Battery life 400 hours Memory Record up to 65,000 readings RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed: Up to 20 m
Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Temperature coefficient Add 0.1X (specified accuracy)/ °C (<18°C or >28°C) Operating humidity 90% at 35°C, 75% at 40°C, 45% at 50°C Altitude Operating: 2,000 m
EMC EN 61326-1:2013 Safety compliance IEC 61010-1, CAT IV 600 V, CAT III 1000 V, 3rd edition Safety rating CAT IV 600 V, CAT III 1000 V Certifications cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP42 Pollution degree 2 Jaw opening 25.4 cm (10 in) coil Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) Weight .22 kg (8 oz)
Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Storage: 12,000 m
(Not compatible with Fluke CNX test tools)
6 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3002 FC Wireless AC/DC Current Meter Module
Designed to be used with the i410 or i1010 ac/dc current clamps (not included with meter). AC/DC current meter that wirelessly relays measurements from the i410 or i1010 clamp accessory to other Fluke Connect
Fluke 3000 FC DMM
Fluke TiX560/520 Infrared Camera
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
a3002 FC main features include:
Measure up to 400 A ac or 400 A dc with i410 (sold separately)
Measure up to 600 A ac or 1000 A dc with i1010 (sold separately)
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
Magnetic hanging strap
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least significant digits ]). Dc ranges are autoranging. Ac accuracy is specified from 1 % to 110 % of the range. dc accuracy is specified from -110 % to 110 % of range.
AC/DC current
Function Range Resolution Accuracy
A dc 1000 A 0.1 A (0.5 % + 3) A ac 600.0 A 0.1 A (1.0 % + 3)
1
AC accuracy is specified from 45 Hz to 1000 Hz
enabled master units, listed below.
1
a3002 FC general specifications
Maximum voltage between terminal and earth ground (meter)
LCD w/backlight 3 ½ digits, 6000 counts, 4/sec update rate Log rate/Interval Adjustable by PC from 1 sec to 1 hr, default 1 min Battery type 2 AA Alkaline batteries, NEDA 15A, IEC LR6 Battery life 400 hours minimum Memory Record up to 65,000 readings RF communications 2.4 GHz ISM Band RF communication range Open air, unobstructed: Up to 20 m
Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Temperature coefficient 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C) Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C),
EMC IEC 61236-1:2013
Certifications cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP42 Size (HxWxD) 160 mm x 66 mm x 38 mm (6.3 in x 2.6 in x 1.5 in) Weight 0.255 kg (9 oz)
30 V dc or ac rms
Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
0 % to 45 % (40 °C to 50 °C)
Protected to IEC 61010-1, 3rd edition, Pollution Degree 2
(Not compatible with Fluke CNX test tools)
7 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3003 FC Wireless 2000 A DC Current Clamp Meter
A fully functional current clamp meter that wirelessly relays measure­ments to other Fluke Connect
enabled master units, listed below.
Fluke 3000 FC DMM
Fluke TiX560/520 Infrared Camera
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
a3003 FC main features include:
Measures up to 2000 A dc
Large jaw size (64 mm) for measuring large, high current
conductors
Logging function for the recording and saving up to 65,000
measurements
a3003 FC general specifications
Range 1.0 A to 999.9 A dc, 1000 A to 2000 A dc Resolution 0.1 A, 1 A Accuracy 2 LCD w/backlight 3½ digits Log rate/interval 1 sec minimum/adjustable by PC or front panel Battery type 2 AA, NEDA 15 A, IEC LR6 Battery life 120 hours Memory Record up to 65,000 readings RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed (up to 20 m) Operating temperature Obstructed, sheetrock wall (up to 6.5 m)
Storage temperature -40 °C to +60 °C Temperature coefficient Add 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C) Operating humidity 90 % at 35 °C
Altitude Operating: 2,000 m
EMC EN 61326-1:2013 Safety compliance IEC 61010-1, CAT IV 600 V, CAT III 1000 V, 3rd edition Safety rating CAT IV 600 V, CAT III 1000 V Certifications cCSAus Ingress Protection (IP) rating IP42 Jaw opening 64mm Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) Weight .65 kg (1.75 lb)
% ± 5 digits, 2.5 % ± 5 digits
Obstructed, concrete wall or steel electrical enclosure (up to 3.5 m)
-10 °C to +50 °C
75 % at 40 °C 45 % at 50 °C
Storage: 12,000 m
, CE, FCC: T68-FBLE IC: 6627A-FBLE
(Not compatible with Fluke CNX test tools)
8 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3004 FC Wireless DC 4-20 mA Current Meter
A fully functional current clamp meter that wirelessly relays measure­ments to other Fluke Connect
enabled master units, listed below.
Fluke 3000 FC DMM
Fluke TiX560/520 Infrared Camera
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
a3004 FC main features include:
Measure 4 to 20 mA signals without “breaking the loop”
Detachable clamp with extension cable for measurements in tight
locations
Use as a standalone meter or as part of the system
Logging function for the recording and saving up to 65,000
measurements
a3004 FC general specifications
Range 0.05 mA to 20.99 mA dc, 21.0 mA to 99.9 mA dc Resolution 0.01 mA, 0.1 A Accuracy 0.2 LCD w/backlight 3½ digits Log rate/interval 1 sec minimum/adjustable by PC or front panel Battery type 2 AA, NEDA 15 A, IEC LR6 Battery life 45 hours Memory Record up to 65,000 readings RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed (up to 20 m) Operating temperature Obstructed, sheetrock wall
Storage temperature -40 °C to +60 °C Temperature coefficient Add 0.1 X (specified accuracy)/°C (<18 °C or >28 °C) Operating humidity 90 % at 35 °C
Altitude Operating: 2,000 m
EMC EN 61326-1:2013 Certifications cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP42 Jaw opening 4.5 mm Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) Weight .299 kg (0.8 lb)
% ± 5 digits, 1.0 % ± 5 digits
(up to 6.5 m)
Obstructed, concrete wall or steel electrical enclosure (up to 3.5 m)
-10 °C to +50 °C
75 % at 40 °C
% at 50 °C
45
Storage: 12,000 m
(Not compatible with Fluke CNX test tools)
9 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke v3000 FC Wireless True-rms AC Voltage Meter
A fully functional true-rms voltage meter that wirelessly relays ac voltage measurements to other Fluke Connect
Fluke 3000 FC DMM
Fluke TiX560/520 Infrared Camera
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
v3000 FC main features include:
True-rms ac voltage meter
Measure up to 1000 V
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
TL224 Test Leads
AC285 Alligator Clips
Magnetic hanging strap
Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.
AC voltage
1
Range
6.000V 0.001V
60.00V 0.01V
600.0V 0.1V 1000V 1V
1
All ac voltage ranges are specified from 1% of range to 100% of range.
2
Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor ≤ 1.5 at 1000V.
3
For non-sinusoidial waveforms, add –(2% of reading + 2% full scale) typical, for crest factor up to 3.
4
Do not exceed 106 V-Hz.
Resolution
enabled master units, listed below.
Accuracy
2,3,4
45Hz to 500Hz 500Hz to 1kHz
1.0% + 3 2.0% + 3
v3000 FC general specifications
LCD w/backlight 3½ digits, 6000 counts, updates 4/sec Battery type 2 AA, NEDA 15A, IEC LR6 Battery life 400 Hours Memory Record up to 65000 readings RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed: Up to 20 m
Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Temperature coefficient 0.1X (specified accuracy)/°C (< 18°C or > 28°C) Operating humidity 90% at 35°C, 45% at 40°C, 45% at 50°C Altitude Operating: 2,000 m
EMC EN 61326-1:2013 Safety compliance ANSI/ISA 61010-1/(82.02.01): 3rd edition
Safety rating CAT IV 600 V, CAT III 1000 V Certifications cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP42 Pollution Degree 2 Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) Weight .22 kg (8 oz)
(Not compatible with Fluke CNX test tools)
Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Storage: 12,000 m
CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010
10 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke v3001 FC Wireless DC Voltage Meter
A fully functional dc voltage meter that wirelessly relays dc voltage measurements to other Fluke Connect
Fluke 3000 FC DMM
Fluke TiX560/520 Infrared Camera
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
v3001 FC main features include:
Measure up to 1000 V dc
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
TL222 Test Leads
AC220 Alligator Clips
Magnetic hanging strap
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with rela­tive humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least significant digits ]).All ranges are autoranging. Accuracy is specified from the range obtained by autoranging, from 18 °C to 28 °C.
DC voltage
Function Range Resolution Accuracy
mV dc 600.0 mV 0.1 mV 0.09 % + 3 V dc 6.000 V 0.001 V 0.09 % + 3
enabled master units, listed below.
60.00 V 0.01 V
600.0 V 0.1 V 1000 V 1 V 0.15% + 2
v3001 FC general specifications
LCD w/backlight 3 ½ digits, 6000 counts, 4/sec update rate Battery type 2 AA Alkaline batteries, NEDA 15A, IEC LR6 Log rate/Interval Adjustable by PC from 1 sec to 1 hr, default 1 min Battery life 400 hours minimum Memory Record up to 65,000 readings RF communications 2.4 GHz ISM Band RF communication range Open air, unobstructed: Up to 20 m
Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Temperature coefficient 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C) Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C),
EMC IEC 61236-1:2013 Safety Compliance IEC 61010-1, CAT IV 600 V, CAT III 1000 V, 3rd edition
Certifications cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP42 Size (HxWxD) 160 mm x 66 mm x 38 mm (6.3 in x 2.6 in x 1.5 in) Weight 0.255 kg (9 oz)
(Not compatible with Fluke CNX test tools)
Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
0 % to 45 % (40 °C to 50 °C)
Pollution Degree 2
11 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke t3000 FC Wireless K-Type Temperature Meter
A versatile K-type thermocouple thermometer wirelessly relays measurements to other Fluke Connect
enabled master units, listed below.
Fluke 3000 FC DMM
Fluke TiX560/520 Infrared Camera
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
t3000 FC main features include:
K-type Thermocouple Thermometer
80PK-1 K-type Bead Thermocouple
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
Magnetic hanging strap
Other K-type temperature probes also available
t3000 FC general specifications
Range K-type: -200°C to 1372°C Resolution 0.1°C Accuracy ± [0.5% + 0.5°C] counts Input terminals K-type mini LCD w/backlight 3 ½ digits Log rate/interval 1 sec minimum/adjustable by PC Battery type 2 AA, NEDA 15A, IEC LR6 Battery life 400 hours Memory Record up to 65,000 readings RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed: Up to 20 m
Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Temperature coefficient 0.01% of reading +0.03°C per °C Temperature scale ITS-90 Operating humidity 90% at 35°C, 75% at 40°C, 45% at 50°C Altitude Operating: 2,000 m
EMC EN 61326-1:2013 Safety compliance IEC 61010-1, 3rd edition Certifications cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP42 Pollution Degree 2 Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) Weight .22 kg (8 oz)
(Not compatible with Fluke CNX test tools)
Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Storage: 12,000 m
12 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke pc3000 FC Adapter and Software
Fluke 3000 FC Wireless Test Tools show real-time measurements from remote meter modules up to 20 meters away on your PC
Fluke FC wireless test tools work together to help you troubleshoot faster. The pc3000 FC Adapter and Software help you understand the information you measure. When you need to get information back to a PC the pc3000 FC Adapter and Software wirelessly collects up to 65,000 sets of time stamped min/max/avg readings from FC remote meter modules. Software can display live readings from up to six meter modules simul­taneously. Allows custom logging intervals and custom names for meter modules. Includes Windows SW3000 software.
Software requirements:
Fluke pc3000 must be connected to the USB port in order to enable com­munication between FC meter modules and software. SW3000 will support up to two pc3000 FC Adapters.
OS Compatibility:
Windows XP or later.
Not compatible with Fluke CNX test tools
RF connection time (binding time) can be up to one minute for all FC wireless tools.
13 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Ordering information
Main units: FLK-3000FC FC Wireless Digital Multimeter
Meter modules: FLK-A3000FC FC Wireless AC Current Clamp Meter FLK-A3001FC FC Wireless iFlex AC Current Meter FLK-A3002FC FC Wireless AC/DC Current Meter Module FLK-A3003FC FC Wireless DC Current Clamp Meter FLK-A3004FC FC Wireless DC 4-20mA Current Meter FLK-V3000FC FC Wireless AC Voltage Meter FLK-V3001FC FC Wireless DC Voltage Meter FLK-T3000FC FC Wireless K-Type Temperature Meter FLK-PC3000FC PC Adapter and Software
Kits:
FLK-3000 FC Industrial Kit Fluke 3000 FC Industrial System includes
multimeter, three iFlex clamp meters, one ac voltage meter, PC adapter and desktop software, accessories FLK-3000 FC General Maintenance Kit Fluke 3000 FC General Maintenance System includes multimeter, iFlex clamp meter, ac voltage meter, dc voltage meter, PC adapter and desktop software, accessories FLK-3000 FC HVAC Kit Fluke 3000 FC HVAC System includes multimeter, ac current clamp meter, temperature meter, PC adapter and desktop software, accessories FLK-T3000 FC Kit Fluke t3000 FC Kit includes multimeter, temperature meter, accessories FLK-A3000 FC Kit Fluke a3000 FC Kit includes multimeter, ac current clamp meter, accessories FLK-A3001 FC Kit Fluke a3001 FC Kit includes multimeter, iFlex clamp meter, accessories FLK-A3003 FC Kit Fluke a3003 FC Kit includes dc current meter w/2000A current clamp, ac current meter w/iFlex, PC adapter and desktop software, soft carry case, accessories FLK-A3004 FC Kit Fluke a3004 FC Kit includes multimeter, dc current meter w/4-20 mA current clamp, PC adapter and desktop software, soft carry case, accessories FLK-V3000 FC Kit Fluke v3000 FC Kit includes multimeter, ac voltage meter, accessories FLK-V3001 FC Kit Fluke v3001 FC Kit includes multimeter, dc voltage meter, accessories FLK-V3003 FC Kit Fluke v3003 FC Kit includes multimeter, ac voltage meter, dc voltage meter, accessories
Fluke. Keeping your world
up and running.
®
14 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Loading...