Start building tomorrow’s test tool system
today with the Fluke 3000 FC Digital
Multimeter.
The new Fluke Connect system of test tools
communicates with the new Fluke Connect mobile
app on your Android™ or iOS smart device, allowing
you to share live measurements, monitor readings
from safe distances, and get your job done easier
than ever before. The wireless digital multimeter
functions as the mobile hub, displaying readings
from up to three meter modules tools simultaneously
from up to 20 meters away. The Fluke Connect
meters also give you the flexibility to build your
wireless test tool system how you want when you
want.
Fluke 3000 FC Test Tools
(Not compatible with Fluke CNX test tools)
• Wireless Digital Multimeter
• iFlex True-rms AC Current Clamp Meter
• True-rms AC Current Clamp Meter
• AC Voltage Meter
• K-Type Temperature Meter
• AC/DC Current Clamp Meter Module
• 2000 A DC Current Clamp Meter
• 4-20 mA DC Current Clamp Meter
• DC Voltage Meter
• PC Adapter
Productivity
• Communicate with your iOS (4s and later) and
Android™ (4.3 and up) devices with the new Fluke
Connect mobile app
• Wireless technology allows connectivity between
your phone, PC, and all Fluke Connect enabled test
tools
• Let your team see what you see in an instant with
ShareLive™ video call
• Save money and time by taking multiple measurements simultaneously
• Isolate intermittent events or record signal fluctuations without even being there using the log
function on the meters
Built with
See it. Save it. Share it.
All the facts, right in the field.
Fluke Connect with ShareLive™ is the only wireless measurement system
that lets you stay in contact with your entire team without leaving the
field. The Fluke Connect mobile app is available for Android™ (4.3
and up) and iOS (4s and later) and works with over 20 different Fluke
products—the largest suite of connected test tools in the world. And more
are on the way. Go to the Fluke website to find out more.
Make the best decisions faster than ever before by viewing all
temperature, mechanical, electrical and vibration measurements for
each equipment asset in one place. Get started saving time and
increasing your productivity.
Download the app at:
Smart phone not included with purchase.
Productivity (continued)
• View results on your computer with the PC Adapter
•
k with fewer interruptions by recording multiple
Wor
sessions before downloading. Data is saved to a PC
in .csv format (comma separated variable) file format
for easy viewing at your convenience
•
Capture readings a
recording intervals from one second to one hour
• Future proof your investment by adding functionality
to the 3000 FC DMM when you need it
t different intervals, with user-set
Convenience
• Send and communicate test data to your manager
and coworkers to assess abnormal system response
in seconds
Have all asset
•
downloading to your PC for future asset performance
tracking and reliability programs
See multiple measurements on one screen
•
a
t one time (DMM and three meter modules,
Ti200/300/400 and five meter modules)
No more writing da
•
sets of min/max/avg readings over single or multiple
logging sessions using the recording capability. Each
reading and session is time stamped
test results at your fingertips after
ta down. Capture up to 65,000
Av
•
oid awkward or uncomfortable measurement positions. Set up the measurement once, step
back and read it as many times as you want, when
you want
• View up to 6 live readings at once on the Fluke
Connect mobile app or a PC to get a complete
understanding of the situation
Easily see backlit
•
environments
Choose auto or
•
Use the optional TP
•
more hands-free working
Int
•
egrated holster protects the meters, while probe
holders keep accessories organized
displays in dark or dimly lit work
manual ranging
ak Magnetic Hanger for even
Safety
• Be in multiple places at once, reducing the risk of
arc flash by separating yourself from hazardous
measurement situations
•
Fluke 3000 FC meets Measurement
CAT III and Category IV 600 V safety standards: AC
Current Clamp Meter and AC/DC Current Clamp Meter
Module 600 V CAT III; AC Voltage Meter, DC Voltage
Meter, and iFlex Clamp Meters 600 V CAT IV/1000
CAT III
Category 1000 V
(RF connection time (binding time) can take up to 1 minute.)
2 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
General specifications
Fluke 3000 FC Series Wireless Multimeter
Detailed specifications (Not compatible with Fluke CNX test tools)
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take
the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
AC voltage
1
Range
Resolution
45Hz to 500Hz500Hz to 1kHz
600.0mV0.1mV
6.000V0.001V
Accuracy
60.00V0.01V
1.0% + 32.0% + 3
600.0V0.1V
1000V1V
1
All ac voltage ranges are specified from 1% of range to 100% of range.
2
Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor < 1.5 at 1000V.
3
For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4
Do not exceed 107 V-Hz.
DC voltage, continuity, resistance, diode test and capacitance
FunctionRangeResolutionAccuracy
mV600.0mV0.1mV0.09% + 2
V6.000V0.001V
0.09% + 260.00V0.01V
600.0V0.1V
1000V1V0.15% + 2
Ω600Ω1ΩMeter beeps at < 25Ω, beeper detects opens or shorts
In the 9999μF range for measurements to 1000μF, the measurement accuracy is 1.2% + 2.
9999μF
1μF10% typical
of 250μs or longer.
0.5% + 1
1.2% + 210.00μF0.01μF
2,3,4
Contents
AC and DC current
FunctionRange
mA AC (45Hz to 1kHZ)
2
mA DC
1
All ac current ranges are specified from 5% of range to 100% of range.
2
Input burden voltage (typical): 400mA input 2mV/mA.
3
400.0 mA accuracy specified up to 600mA overload.
3 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
1
ResolutionAccuracy
60.00mA0.01mA
400.0mA
3
0.1mA
60.00mA0.01mA
400.0mA
3
0.1mA
1.5% + 3
0.5% + 3
Frequency
Range ResolutionAccuracy
99.99Hz0.01Hz
999.9Hz0.1Hz
9.999kHz0.001kHz
99.99kHz0.01kHz
1
Frequency is specified up to 99.99kHz in volts and up to 10kHz in amps.
0.1% + 1
[1]
Input characteristics
Function
Protection
1100 V rms> 10 MΩ < 100 pF> 120 dB at dc, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 V rms> 10 MΩ < 100 pF> 60 dB, dc to 60 Hz
1100 V rms> 10 MΩ < 100 pF> 120 dB at dc, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 V rms< 2.7 V dc< 0.7 V dc< 0.9 V dc< 350 mA
1100 V rms< 2.7 V dc2.000 V dc< 1.1 mA
FunctionOverload ProtectionOverload
mAFused, 44/100A, 1000V FAST Fuse600mA overload for 2minutes maximum, 10minutes rest minimum
Overload
Input Impedance
(nominal)Common Mode Rejection Ratio (1 kΩ unbalance)Normal Mode Rejection
Open circuit test voltage
Full scale voltage
To 6 MΩ50 MΩ
Typical short circuit current
MIN/MAX recording
FunctionAccuracy
DC functionsThe specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration.
AC functionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.
General specifications (Not compatible with Fluke CNX test tools)
Maximum voltage between any
terminal and earth ground
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate: 4/sec
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20m
TemperatureOperating: -10 °C to 50 °C
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Relative humidity0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35°C to 40°C), 0% to 45% (40°C to 50°C)
AltitudeOperating: 2,000 m
Electromagnetic compatibilty
EMI, RFI, EMC, RF
Safety complianceANSI/ISA 61010-1 / (82.02.01): 3
CertificationscCSAus, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution Degree2
Size (H x W x L)4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight340 g (12 oz)
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
Storage: -40 °C to 60 °C
Storage: 12,000 m
EN 61326-1:2013, EN 61326-2-2:2013. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249,
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
rd
edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
4 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3000 FC Wireless AC Current Clamp Meter
A fully functional true-rms current clamp meter that wirelessly relays
measurements to other Fluke Connect
™ enabled master units, listed
below.
• Fluke 3000 FC DMM
• Fluke TiX560/520 Infrared Camera
• Fluke Ti200/300/400 Infrared Camera
• PC via optional pc3000 FC Adapter
• Fluke Connect Mobile app
a3000 FC main features include:
• True-rms ac clamp meter
• Measure up to 400 A ac
• Use as a standalone meter or as part of the system
• Logging function for recording and saving up to 65,000 readings
• Inrush function
a3000 FC general specifications
Range0.5 A to 400.0 A
Resolution0.1A
Accuracy400.0 A: 2% ± 5 digits (10Hz to 100Hz), 2.5% ± 5 digits
InrushMax displayed reading: 999.9A
Crest factor (50Hz/60Hz)3 at 500A, 2.5 at 600A, 1.42 at 1000A, add 2% for C.F. > 2
LCD w/backlight3½ digits
Log rate/interval1 sec minimum/adjustable by PC
Battery type2 AA, NEDA 15A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficientAdd 0.1x (specified accuracy)/°C (< 18°C or > 28°C)
Operating humidity90% at 35°C, 75% at 40°C, 45% at 50°C
AltitudeOperating: 2,000 m
EMCEN 61326-1:2013
Safety complianceIEC 61010-1, CAT III 600 V, CAT IV 300 V, 3rd edition
Safety ratingCAT III 600 V, CAT IV 300 V
CertificationscCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP30
Pollution Degree2
Jaw opening34 mm (1.33 in)
Size (HxWxD)20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in)
Weight.22 kg (8 oz)
(100Hz to 500Hz)
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Storage: 12,000 m
(Not compatible with Fluke CNX test tools)
5 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.