The new Fluke Connect system of test tools communicates with the new Fluke Connect mobile app on your Android™ or iOS smart device, allowing you to share live measurements, monitor readings from safe distances, and get your job done easier than ever before. The wireless digital multimeter functions as the mobile hub, displaying readings from up to three meter modules tools simultaneously from up to 20 meters away. The Fluke Connect meters also give you the flexibility to build your wireless test tool system how you want when you want.
Fluke 3000 FC Test Tools (Not compatible with Fluke CNX test tools)
Wireless Digital Multimeter
iFlex True-rms AC Current Clamp Meter
True-rms AC Current Clamp Meter
AC Voltage Meter
K-Type Temperature Meter
AC/DC Current Clamp Meter Module
2000 A DC Current Clamp Meter
4-20 mA DC Current Clamp Meter
DC Voltage Meter
PC Adapter
Productivity
Communicate with your iOS (4s and later) and Android™ (4.3 and up) devices with the new Fluke Connect mobile app
Wireless technology allows connectivity between your phone, PC, and all Fluke Connect enabled test tools
Let your team see what you see in an instant with ShareLive™ video call
Save money and time by taking multiple measure­ments simultaneously
Isolate intermittent events or record signal fluc­tuations without even being there using the log function on the meters
Built with
See it. Save it. Share it. All the facts, right in the field.
Fluke Connect with ShareLive™ is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is available for Android™ (4.3 and up) and iOS (4s and later) and works with over 20 different Fluke products—the largest suite of connected test tools in the world. And more are on the way. Go to the Fluke website to find out more.
Make the best decisions faster than ever before by viewing all temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Download the app at:
Smart phone not included with purchase.
Productivity (continued)
View results on your computer with the PC Adapter
k with fewer interruptions by recording multiple
Wor sessions before downloading. Data is saved to a PC in .csv format (comma separated variable) file format for easy viewing at your convenience
Capture readings a recording intervals from one second to one hour
Future proof your investment by adding functionality to the 3000 FC DMM when you need it
t different intervals, with user-set
Convenience
Send and communicate test data to your manager and coworkers to assess abnormal system response in seconds
Have all asset
downloading to your PC for future asset performance tracking and reliability programs
See multiple measurements on one screen
a
t one time (DMM and three meter modules,
Ti200/300/400 and five meter modules) No more writing da
sets of min/max/avg readings over single or multiple logging sessions using the recording capability. Each reading and session is time stamped
test results at your fingertips after
ta down. Capture up to 65,000
Av
oid awkward or uncomfortable measurement posi­tions. Set up the measurement once, step back and read it as many times as you want, when you want
View up to 6 live readings at once on the Fluke Connect mobile app or a PC to get a complete understanding of the situation
Easily see backlit
environments Choose auto or
Use the optional TP
more hands-free working Int
egrated holster protects the meters, while probe
holders keep accessories organized
displays in dark or dimly lit work
manual ranging
ak Magnetic Hanger for even
Safety
Be in multiple places at once, reducing the risk of arc flash by separating yourself from hazardous measurement situations
Fluke 3000 FC meets Measurement CAT III and Category IV 600 V safety standards: AC Current Clamp Meter and AC/DC Current Clamp Meter Module 600 V CAT III; AC Voltage Meter, DC Voltage Meter, and iFlex Clamp Meters 600 V CAT IV/1000 CAT III
Category 1000 V
(RF connection time (binding time) can take up to 1 minute.)
2 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
General specifications
Fluke 3000 FC Series Wireless Multimeter
Detailed specifications (Not compatible with Fluke CNX test tools)
For all specifications: accuracy is specified for one year after calibration, at operating temper­atures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
AC voltage
1
Range
Resolution
45Hz to 500Hz 500Hz to 1kHz
600.0mV 0.1mV
6.000V 0.001V
Accuracy
60.00V 0.01V
1.0% + 3 2.0% + 3
600.0V 0.1V 1000V 1V
1
All ac voltage ranges are specified from 1% of range to 100% of range.
2
Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor < 1.5 at 1000V.
3
For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4
Do not exceed 107 V-Hz.
DC voltage, continuity, resistance, diode test and capacitance
Function Range Resolution Accuracy
mV 600.0mV 0.1mV 0.09% + 2 V 6.000V 0.001V
0.09% + 260.00V 0.01V
600.0V 0.1V 1000V 1V 0.15% + 2
600Ω 1Ω Meter beeps at < 25Ω, beeper detects opens or shorts
600.0Ω 0.1Ω 0.5% + 2
6.000kΩ 0.001kΩ
60.00kΩ 0.01kΩ
60.00kΩ 0.1kΩ
600.0kΩ 0.001MΩ
50.00MΩ 0.01MΩ 1.5% + 3 Diode test 2.000V 0.001V 1% + 2 µF 1000nF 1nF
100.0μF 0.1μF
1
1
In the 9999μF range for measurements to 1000μF, the measurement accuracy is 1.2% + 2.
9999μF
1μF 10% typical
of 250μs or longer.
0.5% + 1
1.2% + 210.00μF 0.01μF
2,3,4
Contents
AC and DC current
Function Range
mA AC (45Hz to 1kHZ)
2
mA DC
1
All ac current ranges are specified from 5% of range to 100% of range.
2
Input burden voltage (typical): 400mA input 2mV/mA.
3
400.0 mA accuracy specified up to 600mA overload.
3 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
1
Resolution Accuracy
60.00mA 0.01mA
400.0mA
3
0.1mA
60.00mA 0.01mA
400.0mA
3
0.1mA
1.5% + 3
0.5% + 3
Frequency
Range Resolution Accuracy
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 0.001kHz
99.99kHz 0.01kHz
1
Frequency is specified up to 99.99kHz in volts and up to 10kHz in amps.
0.1% + 1
[1]
Input characteristics
Function
Protection
1100 V rms > 10 MΩ < 100 pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V rms > 10 MΩ < 100 pF > 60 dB, dc to 60 Hz
1100 V rms > 10 MΩ < 100 pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V rms < 2.7 V dc < 0.7 V dc < 0.9 V dc < 350 mA 1100 V rms < 2.7 V dc 2.000 V dc < 1.1 mA
Function Overload Protection Overload
mA Fused, 44/100A, 1000V FAST Fuse 600mA overload for 2minutes maximum, 10minutes rest minimum
Overload
Input Impedance
(nominal) Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
Open circuit test voltage
Full scale voltage
To 6 MΩ 50 MΩ
Typical short circuit current
MIN/MAX recording
Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration. AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.
General specifications (Not compatible with Fluke CNX test tools)
Maximum voltage between any terminal and earth ground
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate: 4/sec
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6 Battery life 250 hours minimum RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed: Up to 20m
Temperature Operating: -10 °C to 50 °C
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35°C to 40°C), 0% to 45% (40°C to 50°C) Altitude Operating: 2,000 m
Electromagnetic compatibilty EMI, RFI, EMC, RF
Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3
Certifications cCSAus, FCC, CE Ingress Protection (IP) rating IP54 Pollution Degree 2 Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) Weight 340 g (12 oz)
1000 V dc or ac rms
Votls, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts
Obstructed, sheetrock wall: Up to 6.5m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
Storage: -40 °C to 60 °C
Storage: 12,000 m EN 61326-1:2013, EN 61326-2-2:2013. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
rd
edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010
4 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3000 FC Wireless AC Current Clamp Meter
A fully functional true-rms current clamp meter that wirelessly relays measurements to other Fluke Connect
enabled master units, listed
below.
Fluke 3000 FC DMM
Fluke TiX560/520 Infrared Camera
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
a3000 FC main features include:
True-rms ac clamp meter
Measure up to 400 A ac
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
Inrush function
a3000 FC general specifications
Range 0.5 A to 400.0 A Resolution 0.1A Accuracy 400.0 A: 2% ± 5 digits (10Hz to 100Hz), 2.5% ± 5 digits
Inrush Max displayed reading: 999.9A Crest factor (50Hz/60Hz) 3 at 500A, 2.5 at 600A, 1.42 at 1000A, add 2% for C.F. > 2 LCD w/backlight 3½ digits Log rate/interval 1 sec minimum/adjustable by PC Battery type 2 AA, NEDA 15A, IEC LR6 Battery life 400 hours Memory Record up to 65,000 readings RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed: Up to 20 m
Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Temperature coefficient Add 0.1x (specified accuracy)/°C (< 18°C or > 28°C) Operating humidity 90% at 35°C, 75% at 40°C, 45% at 50°C Altitude Operating: 2,000 m
EMC EN 61326-1:2013 Safety compliance IEC 61010-1, CAT III 600 V, CAT IV 300 V, 3rd edition Safety rating CAT III 600 V, CAT IV 300 V Certifications cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP30 Pollution Degree 2 Jaw opening 34 mm (1.33 in) Size (HxWxD) 20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in) Weight .22 kg (8 oz)