Start building tomorrow’s test tool system
today with the Fluke 3000 FC Digital
Multimeter.
The new Fluke Connect system of test tools
communicates with the new Fluke Connect mobile
app on your Android™ or iOS smart device, allowing
you to share live measurements, monitor readings
from safe distances, and get your job done easier
than ever before. The wireless digital multimeter
functions as the mobile hub, displaying readings
from up to three meter modules tools simultaneously
from up to 20 meters away. The Fluke Connect
meters also give you the flexibility to build your
wireless test tool system how you want when you
want.
Fluke 3000 FC Test Tools
(Not compatible with Fluke CNX test tools)
• Wireless Digital Multimeter
• iFlex True-rms AC Current Clamp Meter
• True-rms AC Current Clamp Meter
• AC Voltage Meter
• K-Type Temperature Meter
• AC/DC Current Clamp Meter Module
• 2000 A DC Current Clamp Meter
• 4-20 mA DC Current Clamp Meter
• DC Voltage Meter
• PC Adapter
Productivity
• Communicate with your iOS (4s and later) and
Android™ (4.3 and up) devices with the new Fluke
Connect mobile app
• Wireless technology allows connectivity between
your phone, PC, and all Fluke Connect enabled test
tools
• Let your team see what you see in an instant with
ShareLive™ video call
• Save money and time by taking multiple measurements simultaneously
• Isolate intermittent events or record signal fluctuations without even being there using the log
function on the meters
Built with
See it. Save it. Share it.
All the facts, right in the field.
Fluke Connect with ShareLive™ is the only wireless measurement system
that lets you stay in contact with your entire team without leaving the
field. The Fluke Connect mobile app is available for Android™ (4.3
and up) and iOS (4s and later) and works with over 20 different Fluke
products—the largest suite of connected test tools in the world. And more
are on the way. Go to the Fluke website to find out more.
Make the best decisions faster than ever before by viewing all
temperature, mechanical, electrical and vibration measurements for
each equipment asset in one place. Get started saving time and
increasing your productivity.
Download the app at:
Smart phone not included with purchase.
Productivity (continued)
• View results on your computer with the PC Adapter
•
k with fewer interruptions by recording multiple
Wor
sessions before downloading. Data is saved to a PC
in .csv format (comma separated variable) file format
for easy viewing at your convenience
•
Capture readings a
recording intervals from one second to one hour
• Future proof your investment by adding functionality
to the 3000 FC DMM when you need it
t different intervals, with user-set
Convenience
• Send and communicate test data to your manager
and coworkers to assess abnormal system response
in seconds
Have all asset
•
downloading to your PC for future asset performance
tracking and reliability programs
See multiple measurements on one screen
•
a
t one time (DMM and three meter modules,
Ti200/300/400 and five meter modules)
No more writing da
•
sets of min/max/avg readings over single or multiple
logging sessions using the recording capability. Each
reading and session is time stamped
test results at your fingertips after
ta down. Capture up to 65,000
Av
•
oid awkward or uncomfortable measurement positions. Set up the measurement once, step
back and read it as many times as you want, when
you want
• View up to 6 live readings at once on the Fluke
Connect mobile app or a PC to get a complete
understanding of the situation
Easily see backlit
•
environments
Choose auto or
•
Use the optional TP
•
more hands-free working
Int
•
egrated holster protects the meters, while probe
holders keep accessories organized
displays in dark or dimly lit work
manual ranging
ak Magnetic Hanger for even
Safety
• Be in multiple places at once, reducing the risk of
arc flash by separating yourself from hazardous
measurement situations
•
Fluke 3000 FC meets Measurement
CAT III and Category IV 600 V safety standards: AC
Current Clamp Meter and AC/DC Current Clamp Meter
Module 600 V CAT III; AC Voltage Meter, DC Voltage
Meter, and iFlex Clamp Meters 600 V CAT IV/1000
CAT III
Category 1000 V
(RF connection time (binding time) can take up to 1 minute.)
2 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
General specifications
Fluke 3000 FC Series Wireless Multimeter
Detailed specifications (Not compatible with Fluke CNX test tools)
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take
the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
AC voltage
1
Range
Resolution
45Hz to 500Hz500Hz to 1kHz
600.0mV0.1mV
6.000V0.001V
Accuracy
60.00V0.01V
1.0% + 32.0% + 3
600.0V0.1V
1000V1V
1
All ac voltage ranges are specified from 1% of range to 100% of range.
2
Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor < 1.5 at 1000V.
3
For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4
Do not exceed 107 V-Hz.
DC voltage, continuity, resistance, diode test and capacitance
FunctionRangeResolutionAccuracy
mV600.0mV0.1mV0.09% + 2
V6.000V0.001V
0.09% + 260.00V0.01V
600.0V0.1V
1000V1V0.15% + 2
Ω600Ω1ΩMeter beeps at < 25Ω, beeper detects opens or shorts
In the 9999μF range for measurements to 1000μF, the measurement accuracy is 1.2% + 2.
9999μF
1μF10% typical
of 250μs or longer.
0.5% + 1
1.2% + 210.00μF0.01μF
2,3,4
Contents
AC and DC current
FunctionRange
mA AC (45Hz to 1kHZ)
2
mA DC
1
All ac current ranges are specified from 5% of range to 100% of range.
2
Input burden voltage (typical): 400mA input 2mV/mA.
3
400.0 mA accuracy specified up to 600mA overload.
3 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
1
ResolutionAccuracy
60.00mA0.01mA
400.0mA
3
0.1mA
60.00mA0.01mA
400.0mA
3
0.1mA
1.5% + 3
0.5% + 3
Frequency
Range ResolutionAccuracy
99.99Hz0.01Hz
999.9Hz0.1Hz
9.999kHz0.001kHz
99.99kHz0.01kHz
1
Frequency is specified up to 99.99kHz in volts and up to 10kHz in amps.
0.1% + 1
[1]
Input characteristics
Function
Protection
1100 V rms> 10 MΩ < 100 pF> 120 dB at dc, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 V rms> 10 MΩ < 100 pF> 60 dB, dc to 60 Hz
1100 V rms> 10 MΩ < 100 pF> 120 dB at dc, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 V rms< 2.7 V dc< 0.7 V dc< 0.9 V dc< 350 mA
1100 V rms< 2.7 V dc2.000 V dc< 1.1 mA
FunctionOverload ProtectionOverload
mAFused, 44/100A, 1000V FAST Fuse600mA overload for 2minutes maximum, 10minutes rest minimum
Overload
Input Impedance
(nominal)Common Mode Rejection Ratio (1 kΩ unbalance)Normal Mode Rejection
Open circuit test voltage
Full scale voltage
To 6 MΩ50 MΩ
Typical short circuit current
MIN/MAX recording
FunctionAccuracy
DC functionsThe specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration.
AC functionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.
General specifications (Not compatible with Fluke CNX test tools)
Maximum voltage between any
terminal and earth ground
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate: 4/sec
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20m
TemperatureOperating: -10 °C to 50 °C
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Relative humidity0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35°C to 40°C), 0% to 45% (40°C to 50°C)
AltitudeOperating: 2,000 m
Electromagnetic compatibilty
EMI, RFI, EMC, RF
Safety complianceANSI/ISA 61010-1 / (82.02.01): 3
CertificationscCSAus, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution Degree2
Size (H x W x L)4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight340 g (12 oz)
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
Storage: -40 °C to 60 °C
Storage: 12,000 m
EN 61326-1:2013, EN 61326-2-2:2013. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249,
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
rd
edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
4 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3000 FC Wireless AC Current Clamp Meter
A fully functional true-rms current clamp meter that wirelessly relays
measurements to other Fluke Connect
™ enabled master units, listed
below.
• Fluke 3000 FC DMM
• Fluke TiX560/520 Infrared Camera
• Fluke Ti200/300/400 Infrared Camera
• PC via optional pc3000 FC Adapter
• Fluke Connect Mobile app
a3000 FC main features include:
• True-rms ac clamp meter
• Measure up to 400 A ac
• Use as a standalone meter or as part of the system
• Logging function for recording and saving up to 65,000 readings
• Inrush function
a3000 FC general specifications
Range0.5 A to 400.0 A
Resolution0.1A
Accuracy400.0 A: 2% ± 5 digits (10Hz to 100Hz), 2.5% ± 5 digits
InrushMax displayed reading: 999.9A
Crest factor (50Hz/60Hz)3 at 500A, 2.5 at 600A, 1.42 at 1000A, add 2% for C.F. > 2
LCD w/backlight3½ digits
Log rate/interval1 sec minimum/adjustable by PC
Battery type2 AA, NEDA 15A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficientAdd 0.1x (specified accuracy)/°C (< 18°C or > 28°C)
Operating humidity90% at 35°C, 75% at 40°C, 45% at 50°C
AltitudeOperating: 2,000 m
EMCEN 61326-1:2013
Safety complianceIEC 61010-1, CAT III 600 V, CAT IV 300 V, 3rd edition
Safety ratingCAT III 600 V, CAT IV 300 V
CertificationscCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP30
Pollution Degree2
Jaw opening34 mm (1.33 in)
Size (HxWxD)20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in)
Weight.22 kg (8 oz)
(100Hz to 500Hz)
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Storage: 12,000 m
(Not compatible with Fluke CNX test tools)
5 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3001 FC Wireless iFlex AC
Current Meter
A true-rms current clamp meter that wirelessly relays
measurements to other Fluke Connect
master units, listed below.
• Fluke 3000 FC DMM
• Fluke TiX560/520 Infrared Camera
• Fluke Ti200/300/400 Infrared Camera
• PC via optional pc3000 FC Adapter
• Fluke Connect Mobile app
The iFlex™ Wireless Current Meter allows you to measure around awkward sized conductors or get into
tight spaces and makes wire access easier.
• Contains: One true-rms flexible current meter and
one iFlex i2500-10 Flexible Current Probe
• Measure up to 2500 A ac
• Use as a standalone meter or as part of the system
• Logging function for recording and saving up to
65,000 readings
• Inrush function
• Magnetic hanging strap
™ enabled
a3001 FC general specifications
Range0.5 A to 2500 A AC
Resolution0.1 A
Accuracy3% ± 5 digits (5 Hz to 500 Hz)
Crest factor (50Hz/60Hz)3.0 at 1100A, 2.5 at 1400A, 1.42 at 2500A, add 2% for C.F. > 2
LCD w/backlight3½ digits
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficientAdd 0.1X (specified accuracy)/ °C (<18°C or >28°C)
Operating humidity90% at 35°C, 75% at 40°C, 45% at 50°C
AltitudeOperating: 2,000 m
EMCEN 61326-1:2013
Safety complianceIEC 61010-1, CAT IV 600 V, CAT III 1000 V, 3rd edition
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationscCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution degree2
Jaw opening25.4 cm (10 in) coil
Size (HxWxD)16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight.22 kg (8 oz)
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Storage: 12,000 m
(Not compatible with Fluke CNX test tools)
6 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3002 FC Wireless AC/DC
Current Meter Module
Designed to be used with the i410 or i1010 ac/dc current clamps (not included with
meter). AC/DC current meter that wirelessly relays measurements from the i410 or i1010
clamp accessory to other Fluke Connect
• Fluke 3000 FC DMM
• Fluke TiX560/520 Infrared Camera
• Fluke Ti200/300/400 Infrared Camera
• PC via optional pc3000 FC Adapter
• Fluke Connect Mobile app
a3002 FC main features include:
• Measure up to 400 A ac or 400 A dc with i410 (sold separately)
• Measure up to 600 A ac or 1000 A dc with i1010 (sold separately)
• Use as a standalone meter or as part of the system
• Logging function for recording and saving up to 65,000 readings
• Magnetic hanging strap
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative
humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least
significant digits ]). Dc ranges are autoranging. Ac accuracy is specified from 1 % to 110 % of the range.
dc accuracy is specified from -110 % to 110 % of range.
AC/DC current
FunctionRangeResolutionAccuracy
A dc1000 A0.1 A(0.5 % + 3)
A ac600.0 A0.1 A(1.0 % + 3)
1
AC accuracy is specified from 45 Hz to 1000 Hz
™ enabled master units, listed below.
1
a3002 FC general specifications
Maximum voltage between
terminal and earth ground
(meter)
LCD w/backlight3 ½ digits, 6000 counts, 4/sec update rate
Log rate/IntervalAdjustable by PC from 1 sec to 1 hr, default 1 min
Battery type2 AA Alkaline batteries, NEDA 15A, IEC LR6
Battery life400 hours minimum
MemoryRecord up to 65,000 readings
RF communications2.4 GHz ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Temperature coefficient0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
Relative humidity0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C),
EMCIEC 61236-1:2013
CertificationscCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Size (HxWxD)160 mm x 66 mm x 38 mm (6.3 in x 2.6 in x 1.5 in)
Weight0.255 kg (9 oz)
30 V dc or ac rms
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
0 % to 45 % (40 °C to 50 °C)
Protected to IEC 61010-1, 3rd edition, Pollution Degree 2
(Not compatible with Fluke CNX test tools)
7 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3003 FC Wireless 2000 A DC
Current Clamp Meter
A fully functional current clamp meter that wirelessly relays measurements to other Fluke Connect
™
enabled master units, listed below.
• Fluke 3000 FC DMM
• Fluke TiX560/520 Infrared Camera
• Fluke Ti200/300/400 Infrared Camera
• PC via optional pc3000 FC Adapter
• Fluke Connect Mobile app
a3003 FC main features include:
• Measures up to 2000 A dc
• Large jaw size (64 mm) for measuring large, high current
conductors
• Logging function for the recording and saving up to 65,000
measurements
a3003 FC general specifications
Range1.0 A to 999.9 A dc, 1000 A to 2000 A dc
Resolution0.1 A, 1 A
Accuracy2
LCD w/backlight3½ digits
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life120 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed (up to 20 m)
Operating temperatureObstructed, sheetrock wall (up to 6.5 m)
Storage temperature-40 °C to +60 °C
Temperature coefficientAdd 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
Operating humidity90 % at 35 °C
AltitudeOperating: 2,000 m
EMCEN 61326-1:2013
Safety complianceIEC 61010-1, CAT IV 600 V, CAT III 1000 V, 3rd edition
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationscCSAus
Ingress Protection (IP) ratingIP42
Jaw opening64mm
Size (HxWxD)16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight.65 kg (1.75 lb)
% ± 5 digits, 2.5 % ± 5 digits
Obstructed, concrete wall or steel electrical enclosure (up to 3.5 m)
-10 °C to +50 °C
75 % at 40 °C
45 % at 50 °C
Storage: 12,000 m
, CE, FCC: T68-FBLE IC: 6627A-FBLE
(Not compatible with Fluke CNX test tools)
8 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3004 FC Wireless DC 4-20 mA Current Meter
A fully functional current clamp meter that wirelessly relays measurements to other Fluke Connect
™
enabled master units, listed below.
• Fluke 3000 FC DMM
• Fluke TiX560/520 Infrared Camera
• Fluke Ti200/300/400 Infrared Camera
• PC via optional pc3000 FC Adapter
• Fluke Connect Mobile app
a3004 FC main features include:
• Measure 4 to 20 mA signals without “breaking the loop”
• Detachable clamp with extension cable for measurements in tight
locations
• Use as a standalone meter or as part of the system
• Logging function for the recording and saving up to 65,000
measurements
a3004 FC general specifications
Range0.05 mA to 20.99 mA dc, 21.0 mA to 99.9 mA dc
Resolution0.01 mA, 0.1 A
Accuracy0.2
LCD w/backlight3½ digits
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life45 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed (up to 20 m)
Operating temperatureObstructed, sheetrock wall
Storage temperature-40 °C to +60 °C
Temperature coefficientAdd 0.1 X (specified accuracy)/°C (<18 °C or >28 °C)
Operating humidity90 % at 35 °C
AltitudeOperating: 2,000 m
EMCEN 61326-1:2013
CertificationscCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Jaw opening4.5 mm
Size (HxWxD)16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight.299 kg (0.8 lb)
% ± 5 digits, 1.0 % ± 5 digits
(up to 6.5 m)
Obstructed, concrete wall or steel electrical enclosure (up to 3.5 m)
-10 °C to +50 °C
75 % at 40 °C
% at 50 °C
45
Storage: 12,000 m
(Not compatible with Fluke CNX test tools)
9 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke v3000 FC Wireless True-rms AC Voltage Meter
A fully functional true-rms voltage meter that wirelessly relays ac voltage
measurements to other Fluke Connect
• Fluke 3000 FC DMM
• Fluke TiX560/520 Infrared Camera
• Fluke Ti200/300/400 Infrared Camera
• PC via optional pc3000 FC Adapter
• Fluke Connect Mobile app
v3000 FC main features include:
• True-rms ac voltage meter
• Measure up to 1000 V
• Use as a standalone meter or as part of the system
• Logging function for recording and saving up to 65,000 readings
• TL224 Test Leads
• AC285 Alligator Clips
• Magnetic hanging strap
Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are
autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging,
from 18 °C to 28 °C.
AC voltage
1
Range
6.000V0.001V
60.00V0.01V
600.0V0.1V
1000V1V
1
All ac voltage ranges are specified from 1% of range to 100% of range.
2
Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor ≤ 1.5 at 1000V.
3
For non-sinusoidial waveforms, add –(2% of reading + 2% full scale) typical, for crest factor up to 3.
4
Do not exceed 106 V-Hz.
Resolution
™ enabled master units, listed below.
Accuracy
2,3,4
45Hz to 500Hz500Hz to 1kHz
1.0% + 32.0% + 3
v3000 FC general specifications
LCD w/backlight3½ digits, 6000 counts, updates 4/sec
Battery type2 AA, NEDA 15A, IEC LR6
Battery life400 Hours
MemoryRecord up to 65000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficient0.1X (specified accuracy)/°C (< 18°C or > 28°C)
Operating humidity90% at 35°C, 45% at 40°C, 45% at 50°C
AltitudeOperating: 2,000 m
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationscCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Pollution Degree2
Size (HxWxD)16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight.22 kg (8 oz)
(Not compatible with Fluke CNX test tools)
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Storage: 12,000 m
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
10 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke v3001 FC Wireless DC Voltage Meter
A fully functional dc voltage meter that wirelessly relays dc voltage measurements to
other Fluke Connect
• Fluke 3000 FC DMM
• Fluke TiX560/520 Infrared Camera
• Fluke Ti200/300/400 Infrared Camera
• PC via optional pc3000 FC Adapter
• Fluke Connect Mobile app
v3001 FC main features include:
• Measure up to 1000 V dc
• Use as a standalone meter or as part of the system
• Logging function for recording and saving up to 65,000 readings
• TL222 Test Leads
• AC220 Alligator Clips
• Magnetic hanging strap
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of
least significant digits ]).All ranges are autoranging. Accuracy is specified from the range obtained by
autoranging, from 18 °C to 28 °C.
LCD w/backlight3 ½ digits, 6000 counts, 4/sec update rate
Battery type2 AA Alkaline batteries, NEDA 15A, IEC LR6
Log rate/IntervalAdjustable by PC from 1 sec to 1 hr, default 1 min
Battery life400 hours minimum
MemoryRecord up to 65,000 readings
RF communications2.4 GHz ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Temperature coefficient0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
Relative humidity0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C),
EMCIEC 61236-1:2013
Safety ComplianceIEC 61010-1, CAT IV 600 V, CAT III 1000 V, 3rd edition
CertificationscCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Size (HxWxD)160 mm x 66 mm x 38 mm (6.3 in x 2.6 in x 1.5 in)
Weight0.255 kg (9 oz)
(Not compatible with Fluke CNX test tools)
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
0 % to 45 % (40 °C to 50 °C)
Pollution Degree 2
11 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke t3000 FC Wireless K-Type Temperature Meter
A versatile K-type thermocouple thermometer wirelessly relays
measurements to other Fluke Connect
™ enabled master units, listed below.
• Fluke 3000 FC DMM
• Fluke TiX560/520 Infrared Camera
• Fluke Ti200/300/400 Infrared Camera
• PC via optional pc3000 FC Adapter
• Fluke Connect Mobile app
t3000 FC main features include:
• K-type Thermocouple Thermometer
• 80PK-1 K-type Bead Thermocouple
• Use as a standalone meter or as part of the system
• Logging function for recording and saving up to 65,000 readings
• Magnetic hanging strap
• Other K-type temperature probes also available
t3000 FC general specifications
RangeK-type: -200°C to 1372°C
Resolution0.1°C
Accuracy± [0.5% + 0.5°C] counts
Input terminalsK-type mini
LCD w/backlight3 ½ digits
Log rate/interval1 sec minimum/adjustable by PC
Battery type2 AA, NEDA 15A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficient0.01% of reading +0.03°C per °C
Temperature scaleITS-90
Operating humidity90% at 35°C, 75% at 40°C, 45% at 50°C
AltitudeOperating: 2,000 m
EMCEN 61326-1:2013
Safety complianceIEC 61010-1, 3rd edition
CertificationscCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution Degree2
Size (HxWxD)16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight.22 kg (8 oz)
(Not compatible with Fluke CNX test tools)
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Storage: 12,000 m
12 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke pc3000 FC Adapter and Software
Fluke 3000 FC Wireless Test Tools show real-time measurements
from remote meter modules up to 20 meters away on your PC
Fluke FC wireless test tools work together to help you troubleshoot faster.
The pc3000 FC Adapter and Software help you understand the information
you measure. When you need to get information back to a PC the
pc3000 FC Adapter and Software wirelessly collects up to 65,000 sets
of time stamped min/max/avg readings from FC remote meter modules.
Software can display live readings from up to six meter modules simultaneously. Allows custom logging intervals and custom names for meter
modules. Includes Windows SW3000 software.
Software requirements:
Fluke pc3000 must be connected to the USB port in order to enable communication between FC meter modules and software. SW3000 will support
up to two pc3000 FC Adapters.
OS Compatibility:
Windows XP or later.
Not compatible with Fluke CNX test tools
RF connection time (binding time) can be up to one minute for all FC
wireless tools.
13 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Ordering information
Main units:
FLK-3000FC FC Wireless Digital Multimeter
Meter modules:
FLK-A3000FC FC Wireless AC Current Clamp Meter
FLK-A3001FC FC Wireless iFlex AC Current Meter
FLK-A3002FC FC Wireless AC/DC Current Meter Module
FLK-A3003FC FC Wireless DC Current Clamp Meter
FLK-A3004FC FC Wireless DC 4-20mA Current Meter
FLK-V3000FC FC Wireless AC Voltage Meter
FLK-V3001FC FC Wireless DC Voltage Meter
FLK-T3000FC FC Wireless K-Type Temperature Meter
FLK-PC3000FC PC Adapter and Software
Kits:
FLK-3000 FC Industrial Kit Fluke 3000 FC Industrial System includes
multimeter, three iFlex clamp meters, one ac voltage meter, PC adapter and
desktop software, accessories
FLK-3000 FC General Maintenance Kit Fluke 3000 FC General Maintenance
System includes multimeter, iFlex clamp meter, ac voltage meter, dc voltage meter,
PC adapter and desktop software, accessories
FLK-3000 FC HVAC Kit Fluke 3000 FC HVAC System includes multimeter,
ac current clamp meter, temperature meter, PC adapter and desktop software,
accessories
FLK-T3000 FC Kit Fluke t3000 FC Kit includes multimeter, temperature meter,
accessories
FLK-A3000 FC Kit Fluke a3000 FC Kit includes multimeter, ac current clamp
meter, accessories
FLK-A3001 FC Kit Fluke a3001 FC Kit includes multimeter, iFlex clamp meter,
accessories
FLK-A3003 FC Kit Fluke a3003 FC Kit includes dc current meter w/2000A
current clamp, ac current meter w/iFlex, PC adapter and desktop software, soft
carry case, accessories
FLK-A3004 FC Kit Fluke a3004 FC Kit includes multimeter, dc current meter
w/4-20 mA current clamp, PC adapter and desktop software, soft carry case,
accessories
FLK-V3000 FC Kit Fluke v3000 FC Kit includes multimeter, ac voltage meter,
accessories
FLK-V3001 FC Kit Fluke v3001 FC Kit includes multimeter, dc voltage meter,
accessories
FLK-V3003 FC Kit Fluke v3003 FC Kit includes multimeter, ac voltage meter,
dc voltage meter, accessories
Fluke. Keeping your world
up and running.
®
14 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.