Fluke 2635A-RF900USB User Manual

2635A-RF900USB
900 MHz RF USB Modem
Instruction Sheet
®
Introduction
The 2635A-RF900USB 900 MHz RF USB Modem (referred to as “the Modem”) is a radio-frequency transceiver that, used together with the 2635A-RF900 Serial RS-232 Modem, creates a wireless link between Fluke Hydra Series Data Loggers and a computer (PC) running Hydra application software.
Note
The modem operates in the 900 MHz frequency range and is approved by the FCC for use in the United States. Operation in other countries may violate local regulations. When operating outside the United States, check with the appropriate governing agency in the host country prior to Modem operation.
This instruction sheet assumes familiarity with the Hydra software and Hydra Series Data Logger operation. If unfamiliar with Hydra software or the Hydra Series hardware, refer to the software user’s documentation or the appropriate Hydra Series Users manual. The Modem is shown in Figure 1.
Contacting Fluke
To locate an authorized service center, visit us on the World Wide Web at www.fluke.com
or call Fluke
using any of the following numbers:
USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-678-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500
Shipping Contents
The Modem comes with the following items:
Instructions for use with the Hydra Series (this
sheet)
Quick Start Guide
CD-ROM with documentation and software
½ wave Dipole Antenna
USB (Universal Serial Bus) 6 ft. cable
Requirements
Config Switch
The Modem requires a PC with one free USB port and Windows XP, 2000, or 98 SE.
Antenna
Reset Switch
Installation
Data Out Data In Power Indicators
USB Port Connector
O
n
Off
D
a
D
ta
a
P
ta
ow
In
e
r
e
t
a
r
R
n
o
n
P
e
t
n
A
h
itc
fig
w
n
S
o
C
h
t
itc
e
s
w
e
S
R
O
u
t
Seria
P
o
l
r
t
7
-1 8
O-O
V
D
-O
C
Power Adapter Jack
efef01.eps
Figure 1. 2635A-RF900USB 900 MHz RF USB Modem
PN 2558814 November 2005 ©2005 Fluke Corporation. All rights reserved. Printed in U.S.A. 1
Each wireless system requires two modems – one base station connected to a PC, and one remote station connected to a Hydra Data Logger. This USB Modem is used as a base station connected to the PC; the remote station connected to the Hydra is a 2635A­RF900 Serial RS-232 Modem.
To ease system setup, the Modem’s factory default settings are correct for proper PC-to-Hydra operation without further adjustments. There are no setup differences between the base and remote stations.
2635A-RF900USB
Instruction Sheet
Base Station Modem
The Modem is connected to the PC as the base station. To set up this modem:
1. Connect the Modem to a free USB port on the PC using the supplied USB cable.
2. The Windows “Found New Hardware Wizard” will appear on the PC. Click the “Next” button to start the driver installation.
3. Depending on the version of Windows, select either the “Install from a specific list or location” or “Search for a suitable driver” option, then click “Next”.
4. Verify the MaxStream CD is inserted. Check “Search removable media (CD-ROM…)” or “CD-ROM drives” box, and then click the “Next” button.
5. If a “Windows Logo Testing” alert box pops up, click “Continue Anyway”.
6. Click the “Next”button again if necessary to accept the selected driver.
7. Click the “Finish” button.
8. Repeat steps 2 through 7 to install the next driver.
9. Connect the supplied antenna to the Modem.
Remote Station
Set up a 2635A-RF900 Serial RS-232 Modem and connect to the Hydra Data Logger as described in its own instruction sheet.
Operation
Start the Hydra software and turn the Hydra Data Logger power on.
Connect through the Hydra software as if using a standard RS-232 connection. Basic line-of-site range is approximately 1500 ft. (450 m). The range varies with antenna height.
The Modem will operate in its default factory setting as an accessory to the Hydra Series. Refer to the manufacturer’s instructions and supplied software for operating the Modem in other applications.
To reset the Modem to its factory settings, push the Reset Switch located on the Antenna-side of the Modem.
Specifications
Performance
Indoor/Urban Range: Up to 1500 ft (450 m) Outdoor LOS Range: Up to 7 miles (11 km) w/ dipole antenna Serial Data Throughput: 9600 bps RF Baud Rate: 10,000 bps Transmit Power Output: 140 mW (21.5 dBm) Receiver Sensitivity: -110 dBm
General
Frequency: 902-928 MHz Spread Spectrum: Frequency Hopping, Wide band FM modulator Network Topology: Peer-to-Peer, Point-to-multipoint, Point-to-Point, Multi-drop Channel Capacity: 7 hop sequences share 25 frequencies Serial Data Interface: USB I/O Data Rate: Software selectable 1200 - 57600 bps
Power Requirements
Supply Voltage: USB bus-powered or 5-12 V dc
external Transmit Current: 215 mA Receive Current: 85 mA
Physical Properties
Enclosure: 7.1 oz (200 g), extruded
aluminum, black anodized Enclosure Size: 2.75 in x 5.50 in x 1.124 in
(7.90 cm x 13.90 cm x 3.80 cm) Operating Temperature: 0 to 70 °C (commercial)
Antenna
Type: ½ wave dipole whip, 6.75 in
(17.1 cm), 2.1 dBi Gain
Not licensed for operation outside of the United States.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for 90 days from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration,contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY.
Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.
Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A.
11/99
Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands
2
Loading...