ScopeMeter 190 Series: Speed,
performance and analysis power
For demanding applications, the ScopeMeter
190 Series high-performance oscilloscopes offer
specifications usually found on top-end bench
instruments. With up to 200 MHz bandwidth,
2.5 GS/s real-time sampling and a deep memory
of 27,500 points per input, they’re ideal for
engineers who need the full capabilities of a
high-performance scope in a handheld, battery
powered instrument.
✓
Dual input - 60, 100 or 200 MHz bandwidth
✓
Up to 2.5 GS/s real-time sampling per input
✓
Connect-and-View™ automatic triggering,
a full range of manual trigger modes plus
external triggering
✓
27,500 points per input record length using
ScopeRecord™ mode
✓
Automatic capture and replay of 100 screens
✓
24 automatic waveform measurements
✓
Cursors, zoom and real-time clock
✓
Four hours rechargeable NiMH battery pack
✓
1,000V CAT II and 600V CAT III safety
certified
✓
Up to 1,000V independently floating isolated
inputs
✓
Includes a 5,000 counts True-rms multimeter
and a TrendPlot™ paperless recorder
E
G
M
A
E
N
N
A
T
M
S
L
A
U
Q
C
E
R
T
I
Y
T
I
F
I
LISTED
Y
S
T
E
M
1
0
0
9
E
O
S
I
D
T
T
E
O
E
M
ScopeMeter 123:
Three-in-one simplicity
The compact ScopeMeter 123 is the rugged solution for industrial troubleshooting and installation
applications. It’s a truly integrated test tool, with
oscilloscope, multimeter and “paperless” recorder
in one affordable, easy-to-use instrument. Find
fast answers to problems in machinery, instrumentation, control and power systems.
✓
A dual input 20 MHz digital oscilloscope
✓
Two 5,000 counts True-rms digital
multimeters
✓
A dual input TrendPlot™ recorder
✓
Connect-and-View™ trigger simplicity for
hands-off operation
✓
Shielded test leads for oscilloscope, resistance
and continuity measurements
Bandwidth limiter: User selectable 10 kHz or 20 MHz
Number of inputs: 2 plus external trigger. All isolated
from each other and ground.
Input coupling: AC, DC with ground level indicator
Input sensitivity: 5 mV/div to100 V/div
Input voltage: See general specifications for maximum
rating
Vertical resolution: 8 bit
Accuracy: ±(1.5% of reading + 0.04 x range/div)
Input impedance: 1 MΩ± 1% // 15 pF ± 2 pF
Horizontal
Fluke 199Fluke 196Fluke 192
Maximum
real-time2.5 GS/s1 GS/s500 MS/s
sample rate
Number of
digitizers
Time base5 ns/div10 ns/div
rangeto 5 s/divto 5 s/div
Maximum record length: 1,000 points per input
27,500 points per input in ScopeRecord
(10 ms/div ... 2 min/div)
Accuracy: ± (0.01% of reading + 1 pixel)
Glitch capture: 50 nsec (5 µsec/div to 1 min/div)
Faster time bases have higher sample rates than
20 MS/s
Display and acquisition
Display modes: Input A, input B, dual, average, persistence, invert, replay
Acquisition modes: Normal, auto, single shot,
ScopeRecord,
222
™
-roll mode
™
roll, glitch capture
Trigger and delay
Source: Input A, input B, external trigger input. All
input references isolated from each other and ground.
Modes: Automatic Connect-and-View,
™
free run, single
shot, edge, delay, video, video line, selectable pulse
width
Connect-and-View
™
: Advanced automatic triggering
that recognizes signal patterns, automatically sets up
and continuously adjusts triggering, time base and
amplitude. Automatically displays stable waveforms of
complex and dynamic signals like motor drive and
control signals.
Video triggering: NTSC, PAL, PAL+, SECAM. Includes
field 1 and 2 and line select.
Pulse width triggering: Pulse width qualified by time.
Allows for triggering <t ,>t, = t, ≠t, where t is selectable in minimal steps of 0.01 div or 50 nsec.
Time delay: 9 divisions pre-trigger view to 1,000
divisions trigger delay
Automatic capture of 100 screens
The instrument ALWAYS memorizes last 100 screens
(no user interaction or setup required). When an
anomaly occurs on screen, there’s 10 seconds to press
HOLD and review it. If one sets up the instrument for
triggering on glitches or intermittent anomalies the
unit operates in “baby-sit” mode and will capture 100
events.
Replay: Manual or continuous replay. Displays the
captured 100 screens as a “live” animation. The
contents can also be viewed by manually scrolling
backwards and forwards “screen by screen”.
Replay storage: Up to 2 sets of 100 screens can be
saved for later recall and analysis.
Automatic scope measurements
VDC, VAC rms, VAC+DC, Vpeak max, Vpeak min, Vpeak
to peak, frequency (Hz), positive pulse width, negative
pulse width, positive duty cycle, negative duty cycle,
amp AC, amp DC, amp AC+DC, power factor, watts, VA,
VA reactive, phase, temperature °C, temperature °F,
dBV, dBm into 50Ω and 600Ω
2 Fluke Corporation ScopeMeter 190 Series and ScopeMeter 123
Cursor measurements
Source: Input A or B
Dual horizontal lines: Voltage at cursor 1 and 2,
voltage between cursors
Dual vertical lines: Time between cursors, voltage
between markers
Single vertical line: Min-Max and Average voltage at
cursor position
Zoom
Up to 8x horizontal zoom
Meter Mode
Via 4 mm banana inputs. Fully isolated from scope
inputs and scope ground. The specified accuracy is
valid over the temperature range 18 °C to 28 °C (15 °F
to 33 °F). Add 10 % of specified accuracy for each
degree °C below 18 °C or above 28 °C (15 °F to 33 °F).
Source and display: Input A, Input B, Dual
Memory depth: 27,500 points per input. Each point
consist of Min-Max pair.
Min-Max values: Min-Max values are measured at
high sample rate ensuring capture and display of
glitches
Time base range10 ms/div to 1 min/div2 min/div
Recorded timespan11 sec to 15 hrs30 hrs
Glitch capture50 nsec250 nsec
Sample rate20 MS/s4 MS/s
Resolution400 µsec to 2 sec4 sec
Recording modes: Single sweep, continuous roll, start
on external trigger
Horizontal scale: Time from start, time of day
Zoom: Up to 100 x zoom
Memory: Up to 2 dual input ScopeRecordings can be
saved for later recall and analysis
TrendPlot™ recording
Dual input electronic paperless chart recorder. Plots,
displays and stores meter and scope measurements.
Source and display: Input A, Input B and DMM input
Memory depth: 13,500 points record per input. Per
record point a minimum, maximum and average value,
and a time and date stamp are stored.
Ranges: 10 s/div to 20 min/div in normal view mode.
10 min/div to 24 hour/div in view-all mode (overview
of total record)
Recorded timespan: Up to 8 days with a resolution of
1 minute
Recording mode: Continuous roll
Measurement speed: 2.5 measurements per second
maximum
Horizontal scale: Time from start, time of day
Zoom: Up to 64x zoom
Memory: Up to 2 TrendPlot recordings can be saved
for later recall and analysis
Cursor measurements - All Recorder Modes
Source: Input A, B or DMM input
Dual vertical lines: Min-Max or Average voltage.
Time between cursors.
Single vertical line: Min-Max or Average voltage.
Absolute date and time or time from start.
ScopeMeter 190 Series and ScopeMeter 123 Fluke Corporation 3
Technical Specifications
ScopeMeter 190 Series
cont.
General Specifications
Case
Design: Rugged, shock proof with integrated
protective holster
Drip and dust proof: IP51 according to IEC529
Shock and vibration: Shock 30g, Vibration 3g
according to MIL 28800F type III, class 3, style B
Display
Bright LCD with CCFL backlight, 35/60 cd/m2 without/with power adapter.
Size: 105 x 79 mm (4.1 x 3.1 inches)
Resolution: 240 x 240 pixels
Contrast and brightness: User adjustable,
temperature compensated
Memory Save and Recall
Scope memories: 10 memory locations that each can
contain two waveforms plus corresponding setup.
Recorder memories: 2 memory locations that each
can contain 100 captured dual input scope screens, or
a dual input ScopeRecord (27,500 Min-Max pairs per
input), or a dual input Trendplot (13,500 Min-Max
pairs per input).
Real-time clock
Time and date stamp for ScopeRecord, 100 captured
screens and Trendplots.
Power
Line power: Country specific line voltage adapter/
battery charger included
Battery power: Rechargeable NiMH (installed)
Battery operating time: 4 hours
Battery charging time: 4 hours
Battery power saving functions: Auto power down
with adjustable power down time. On screen battery
power indicator
Mechanical data
Size: 256 x 169 x 64 mm (10.1 x 6.6 x 2.5 inches)
Weight: 1.95 kg (4.3 lbs)
Maximum probe voltage: 1,000V CAT II, 600V CAT III
(Maximum voltage between 10:1 probe tip (VP190)
and reference lead)
Floating voltage: 1,000V CAT II, 600V CAT III
(Maximum voltage between earth ground and any
terminal (signal input or shielding))
Independently isolated: 1,000V CAT II, 600V CAT III
inputs (Maximum voltage between any terminal of
one input or probe (VP190) and any other terminal
of another input or probe (VP190))
Maximum voltage on BNC input directly
(input A or B): 300V CAT III
Maximum voltage on meter input: 1,000V CAT II,
600V CAT III
Environmental
Operating temperature: 0 °C to +50 °C
Storage temperature: -20 °C to +60 °C
Humidity
10 °C to 30 °C: 95% RH non condensing
30 °C to 40 °C: 75% RH non condensing
40 °C to 50 °C: 45% RH non condensing
Maximum operating altitude: 3,000 m (10,000 feet)
Maximum storage altitude: 12 km (40,000 feet)
Electro-Magnetic Compatibility: EN 61326-1 for
emission and immunity
Optically isolated PC/Printer interface
To printer: Supports HP Laserjet,® Deskjet,® Epson FX/
LQ and postscript printers via optional PAC 91
To PC: Transfer instrument settings, screen images
and waveform data, compatible with FlukeView
ware for Windows
®
via optional PM9080.
®
soft-
Warranty
3 years
4 Fluke Corporation ScopeMeter 190 Series and ScopeMeter 123
Technical Specifications
ScopeMeter 123
Oscilloscope Mode
Vertical deflection
Bandwidth: 20 MHz at inputs; 20 MHz with BB120
and optional PM 8918/VP190 10:1 probes; 12.5 MHz
with STL120 1:1 test leads
Rise time: 17.5 ns
Number of inputs: 2
Input coupling: AC, DC with ground level indicator
Input sensitivity: 5 mV to 500 V/div (with included
STL120 shielded test leads measure up to 600 Vrms)
Vertical resolution: 8 bit
Accuracy: ± (2% of reading + 0.05 x range/div)
Input impedance: 1 MΩ± 1% // 225 pF with STL120
shielded test leads; 1 MΩ± 1% // 20 pF ± 3 pF with
BB120
Horizontal
Maximum sample rate: 1.25 GS/s for repetitive
signals; 25 MS/s for single shot
Number of digitizers: 2
Time base range: 20 ns/div to 1 min/div
Maximum record length: 512 Min-Max points per input
Accuracy: ± (0.1% of reading + 1 pixel)
Glitch detect: 40 ns
Display and acquisition
Display modes: Input A, input A and B, envelope,
smooth
Acquisition modes: Normal, single shot, roll, glitch
capture (always on)
Trigger and delay
Source: Input A, input B, external via optional ITP120
Modes: Automatic Connect-and-View,
Edge, Single Shot, Video, Video Line
Connect-and-View
that recognizes signal patterns and automatically sets
up and continuously adjusts triggering, time base and
amplitude. Automatically displays stable pictures of
complex and dynamic signals like motor drive and
control signals.
Video triggering: NTSC, PAL, PAL+, SECAM. Includes
line select
Time delay: Up to 10 divisions pre-trigger view
™
: Advanced automatic triggering
Measurements
VDC, VAC, VAC+DC, Vpeak max, Vpeak min, Vpeak to
peak, frequency (Hz), positive pulse width, negative
pulse width, positive duty cycle, negative duty cycle,
Amp AC, Amp DC, Amp AC+DC, Phase, Temperature °C,
Temperature °F, dBV, dBm into 50Ω and 600Ω. (Amps,
°C or °F with optional probes)
™
Free Run,
Dual Input Meter
The specified accuracy is valid over the temperature
range 18°C to 28°C (15°F to 33°F). Add 10 % of speci-
fied accuracy for each degree °C below 18°C or above
28°C (15°F to 33°F).
Ranges: 50 nF to 500 µF
Max. resolution: 5,000 counts
Accuracy: ± (2% of reading + 10 counts)
Other meter functions
Frequency: Up to 40 MHz
Continuity: Beeper on < 30Ω
Diode test: Up to 2.8V
Amps: Amp DC, Amp AC, Amp AC+DC using an op-
tional current clamp or shunt
Scaling factors: 0.1 mV/Amp to 100 V/Amp
Temperature (
factors 1 mV/°C or 1 mV/°F.
Number of inputs: 2
Input impedance: 1 MΩ± 1% // 10 pF ± 2 pF
Advanced meter functions: Auto/manual ranging,
TouchHold
TrendPlot recording
°C, °F): With optional accessories. Scale
®
, Relative measurements (zero reference),
ScopeMeter 190 Series and ScopeMeter 123 Fluke Corporation 5
Technical Specifications
ScopeMeter 123
cont.
Recorder Mode
Trendplot™ recording
Dual input electronic paperless chart recorder. Plots
and displays the actual, minimum, maximum and
average of any measurement.
Source and display: Input A, Input A and B
Range: 15 s/div till 2 days per division (automatic)
Recorded timespan: Up to 16 days with a resolution
of 1.5 hours
Recording mode: Continuous with automatic vertical
scaling and horizontal time compression
Measurement speed: 2.5 measurements per second
maximum
Horizontal scale: Time from start
General Specifications
Case
Design: Rugged, shock proof with integrated
protective holster
Drip and dust proof: IP51 according to IEC529
Shock and vibration: Shock 30g, Vibration 3g
according to MIL-T28800E, Type III, Class 3, Style B
Display
Bright LCD with CCFL backlight, 35/60 cd/m2 without/
with adapter
Size: 72 x 72mm (2.8 x 2.8 inch)
Resolution: 240 x 240 pixels
Contrast and brightness: User adjustable, temperature
compensated
Memory Save and Recall
2 screens, 10 user setups
Real-time clock
Time and date stamp TrendPlot recording
Power
Line power: Country specific line voltage adapter/
battery charger included
Battery power: Rechargeable NiCd (installed)
Battery operating time: Up to 5 hours
Battery charging time: 4 hours
Battery refresh cycle: 8 to 14 hours depending on
remaining capacity at start of refresh cycle
Battery power saving functions: Auto power down
with adjustable power down time. On screen battery
power indicator.
Mechanical data
Size: 50 x 115 x 232 mm (2 x 4.5 x 9.1 inches)
Weight: 1.2 kg (2.5 lb.)
Maximum input voltage: 600V CAT III
(Maximum voltage between input and reference lead)
Floating voltage: 600V CAT III
Maximum voltage between earth ground and any
terminal (signal input or reference lead)
Maximum voltage between reference leads:
Instrument has common grounds connected via
self recovering fault protection. For different ground
potential measurements between inputs use DP120
differential voltage probe.
Environmental
Operating temperature: 0°C to +50°C
Storage temperature: -20°C to +60°C
Humidity:
10°C to 30°C, 95% RH non condensing;
30°C to 40°C, 75% RH non condensing;
40°C to 50°C, 45% RH non condensingMaximum operating altitude: 2,000m (6,500 feet);
3,000m (10,000 feet) voltages ≤ 400V
Maximum storage altitude: 12 km (40,000 feet)
Electro-Magnetic: Emission EN50081-1 (EN55022
and EN60555-2)
Compatibility: Immunity EN50082-2
(IEC1000–4-2, -3, -4, -5)
Optically isolated PC/Printer interface
To printer: Supports HP Laserjet,® Deskjet,® Epson
FX/LQ and postscript printers via optional PAC91
To PC: Transfer instrument settings, screen images
and data, compatible with FlukeView
Windows
®
via optional PM9080
®
software for
Warranty
3 years
6 Fluke Corporation ScopeMeter 190 Series and ScopeMeter 123
International Safety
Standards
Overvoltage
CategorySummary description
CAT IVThree phase at utility connection, any outdoors conductors
CAT IIIThree-phase distribution (under 1,000V), including single phase
CAT IISingle-phase receptable connected loads
CAT IElectronic
(under 1,000V)
Outside and service entrance
•
Service drop from pole to building
•
Run between meter and panel
•
Overhead line to detached building
•
Underground line to well pump
•
commercial lighting and distribution panels
Feeders and short branch circuits
•
Distribution panel devices
•
Heavy appliance outlets with “short” connections to service
•
entrance
Outlets and long branch circuits
•
All outlets at more than 10m (30 ft.) from Category III source
•
All outlets at more than 20m (60 ft.) from Category IV source
•
Electronic equipment
•
Low energy equipment with transient limiting protection
•
To protect your instrument and
– more importantly – yourself,
choose a test tool that can withstand the electrical hazards
present in the environment in
which you plan to use it.
EN61010 establishes international safety requirements for
electrical measurement equipment. It separates the various
electrical environments into
installation categories based on
the danger from high voltageenergy transients. To choose the
right tool, the voltage rating
alone does not determine the
safety. It is the combination of
voltage rating and installation
category that determines maximum transient withstand capability of the tool. CAT III rated
instruments are recommended
for measurement on industrial
power distribution systems.
Fluke ScopeMeter test tools come standard with a complete
•
accessory package including line voltage adapter, and battery pack
(installed). ScopeMeter 123 includes the shielded test leads,
ScopeMeter 190 Series comes with probes, probe accessories and
multimeter test leads.
SCC kit includes: Hard-shell carrying case, optically isolated
•
RS-232 interface cable, and FlukeView
with SCC190 kit
with SCC190 kit
with SCC190 kit
Fluke 190 Series
with SCC120 kit
Fluke 123
®
for Windows® software.
ScopeMeter 190 Series and ScopeMeter 123 Fluke Corporation 7
Accessories
Standard accessories:190 Series123
Rechargeable battery pack (installed)BP190BP120
Line voltage adapter / battery chargerBC190PM 8907
Two probes, red & grayVP190-R & VP190-G—
Two shielded test-leads, red & gray—STL120
Test lead, black- (*1)TL75
Two hook clips, black- (*1)HC120
Three alligator clips- (*2)AC120
Shielded banana to BNC adapterBB120
Probe accessory Set, red & grayAS190 - R/G (*2)—
User’s manual9 language versions13 language versions
Optional accessories and replacements: (*3)
Safety designed oscilloscope probes
Differential voltage probeDP120DP120
Optically isolated trigger probe—ITP120
10:1 Voltage probe red or greyVP190-R or VP190-G (*4)
Probe accessory set red or greyAS190-R or AS190-G (*4)
Probe replacement setRS190
Safety designed test leads
Hard point right angle test lead setTL75
Test lead setTL20
Hook clips for use with TL75 & STL120HC120
Alligator clips for use with TL75 & STL120AC120
Pin-grabber test clips for banana plugAC83
Large jaw alligator clips for banana plugAC85A
Hook style clips for banana plugAC80
Alligator clips for banana plugAC20
Industrial test probes for banana plugTP20
Electronic test probes for banana plugTP80
Test probe flat blade for banana plugTP1
Test probe 2mm for banana plugTP2
Test probe 4mm for banana plugTP4
Current probes
AC/DC current probe 50mA to 100A80i-110s (*4)
AC current probe 0.1A to 1,000A80i-1000s (*4)
Flexible AC current probe 1A to 2,000Ai2000flex (*4)
AC current probe 1A to 3,000Ai3000s (*4)
AC current probe 1A to 200Ai200s (*4)
Current shunt 4-20mACS20MA
Temperature probes
Universal temperature probe80T-150U
Thermocouple module80TK
Infrared temperature probe80T-IR
Cables and adapters
Printer adapter cablePAC91
Optically isolated RS-232 adapter/cablePM 9080/001 (*6)
Dual banana plug to female BNC adapterPM 9081/001
Dual banana jack to male BNC adapterPM 9082/001
1.5m 50Ω coaxial BNC cablePM 9091/001
Male BNC to female BNC adapterPM 9093/001
Protective cases
Software cable case packageSCC190 (*5)SCC120 (*5)
Hard carrying caseC190 (*6)C120 (*6)
Soft carrying caseC195C125
PC software
FlukeView software for Windows
®
SW90W/033EFG (*5)
(*1) Probe accessory VP190 set includes test
leads, hook clips.
(*2) The Fluke 196 and 199 include red and
grey probe, accessory set AS190, with 4
heavy duty alligator clips.
(*3) This is a selection of a broader range of
optional accessories that support
ScopeMeter products, for information on
additional available accessories, contact
your Fluke distributor.
(*4) Connects to BNC, for connection to Fluke
123 input use BB120.
(*5) Software Cable Case Package includes
RS-232 cable, FlukeView software &
hard carrying case.
(*6) Included in SCC package.
Fluke. Keeping your world
up and running.
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
U.S.A. (800) 443-5853 or
Fax (425) 356-5116
Europe/M-East/Africa
(31 40) 2 678 200 or
Fax (31 40) 2 678 222
Canada 1-800-36-FLUKE or
Fax (905) 890-6866
Other countries (425) 356-5500 or
Fax (425) 356-5116
Web access: http://www.fluke.com