Flir CP-6302-31-P Installation Guide

Quick Install Guide
Quasar Gen III
CP-6302-31-P
Indoor/Outdoor 30x HD PTZ IP Camera
A. Insert and Configure SD Card
B. Mount the Camera
Verify that the operating temperature range is between -40°C ~ 50°C (-40° ~ 122°F), 0-90% relative humidity (non­condensing). Be sure to have the required accessories and tools available. Refer to the User and Installation Guide for mounting instructions. Make all required wiring connections (See connector details overleaf)
C. Accessing Camera Documentation and Utility Software from the Web
D. Install the ActiveX Plug-in
Ensure that ActiveX controls can be downloaded by: (a) Changing the ActiveX controls and plug-in settings or (b) Setting the Internet security level to default. For further details, refer to the camera’s User and Installation Guide.
To set ActiveX controls & plug-in settings:
·
Start Internet Explorer.
·
Select Tools > Internet Options from the main menu of the browser.
·
Select the Security tab and click Internet.
·
Click Custom level to change ActiveX settings.
·
Set all ActiveX controls and plug-ins settings to Prompt or Enable.
To set the Internet Security Level:
·
Start Internet Explorer.
·
Select Tools > Internet Options from the main menu of the browser.
·
Select the Security tab and click Internet.
·
Click Default level.
·
Click OK.
·
Close and reopen the browser window.
1. After the request to install the ActiveX control file (install.cab) appears on the screen, click Yes.
2. After installing the plug-in, in the pop-up security warning that opens, click Install to start downloading the Quasar Player software onto the PC.
3. Click Finish when the Quasar Player installation is completed.
E. Connect the Camera
3-Pin Power Connector
Power Connector
Pin
Definition
1
AC 24L
2
Ground
3
AC 24N
Terminal Connectors
14-pin Terminal Block
Pin
Definition
Pin
Definition
Pin
Definition
1
Audio-Out
6
Alarm-Out B2
11
Alarm-In2
2
Ground (Audio I/O)
7
RS-485 D+
12
Alarm-In 1
3
Alarm-Out A1
8
RS-485 D-
13
Ground (Alarm I/O and RS-485)
4
Alarm-Out A2
9
Alarm-In 4
14
Audio-In
5
Alarm-Out B1
10
Alarm-In 3
See connector references above
1. Two-pin connector (If using a 12VDC power supply)
2. Console connector (Technician)
3. Cat 5e/Cat 6 cable from the switch to the RJ45 connector for 10/100/1000 Mbps Ethernet and PoE+. If using PoE, use CP-POE-60W PoE injector or equivalent. Verify that there are steady green and flashing yellow LEDs.
4. Three-pin power connector (if using a 24VAC power supply or a heater) (See E. Connectors)
5. Video output to a DVR (Attach coax cable to the BNC connector for video output)
6. 14-pin terminal block connector for alarm and audio in/out - Attach wires from external devices.
7. Factory Reset Button. To reset factory defaults at any time, press the Default button for at least 20 seconds.
F. Discover the Camera
The camera’s web interface can be accessed by Internet Explorer 10 and higher (32-bit) with the ActiveX plug-in and by browsers that do not require ActiveX, such as Microsoft Edge, Chrome or Firefox, on PCs running 64-bit Windows 7, 8, 8.1, or 10.
Set the Camera's IP address and Video Format
1. Download and install the DNA Utility from the FLIR website as shown
above
2. Attach the unit to the same LAN segment as the computer that is
managing the unit. DNA automatically discovers the unit on the network and displays the device’s current IP address in the Discover List.
3. Select the unit from the Discover List.
4. If using a Static IP address (as on a Latitude System), follow
the DNA instructions to set the desired IP address.
5. On a system using DHCP, select the DHCP option in DNA.
6. To select PAL or NTSC, select the device in the Discover list,
right-click to open the context menu and clicking Change Video
Format.
5. Click Update.
G: If using Storage on the Edge
1. Use the Web interface to verify that the card status is displayed as Mounted in the System > Events Handler > SD Card screen.
2. Format the card.
3. Configure the camera to store snapshots and recordings from the System > Events Source screens.
H. Attach to VMS
Once you have completed installation and setup and found the current IP address with DNA, use your VMS Discovery/Attach procedures to attach the camera to your VMS.