FLIR CM78 Operating Manual

User’s manual
FLIR CM78
True RMS Clamp/DMM with infrared thermometer and Bluetooth METERLiNK®
User’s manual
FLIR CM78
#T559826; r. AD/ 9130/9130; en-US
Table of contents
1.1 Copyright. .. . ... ... ... . .. . ... ... ... . .. . .. . ... ... ... . .. . .. . ... ... 1
1.2 Quality assurance .. ... . .. . .. . ... ... ... . .. . .. . ... ... . .. . .. . ... . 1
1.3 Documentation updates . . .. . .. . ... ... . .. . .. . ... ... . .. . .. . ... .. 1
1.4 Disposal of electronic waste... ... ... . .. . .. . ... ... . .. . .. . ... ... 1
2.1 FCC Complicance ... ... . .. . .. . ... ... . .. . .. . ... ... . .. . .. . ... ... 5
2.2 Industry Canada compliance .. . ... ... ... . .. . .. . ... ... ... . .. . .. 6
3.1 Key features. .. . .. . ... ... . .. . .. . ... ... ... . .. . .. . ... ... . .. . .. . ... 7
4.1 Meter parts .. . ... ... ... . .. . .. . ... ... . .. . .. . ... ... . .. . .. . ... ... .. 8
4.2 Function switch . .. . ... ... . .. . .. . ... ... ... . .. . .. . ... ... . .. . .. . .. 9
4.3 Function buttons . ... . .. . .. . ... ... ... . .. . .. . ... ... . .. . .. . ... ... 10
4.4 Display icons and indicators .. . ... ... . .. . .. . ... ... ... . .. . .. . .11
5 Operation ... . .. . .. . ... ... . .. . .. . ... ... . .. . .. . ... ... ... . .. . .. . ... ... . .. . .13
5.1 Powering the meter ... ... . .. . .. . ... ... . .. . .. . ... ... ... . .. . .. . .13
5.2 Auto/Manual range . . ... ... . .. . .. . ... ... ... . .. . .. . ... ... . .. . .. 13
5.3 Current measurements . . .. . .. . ... ... ... . .. . .. . ... ... . .. . .. . ..14
5.4 Voltage measurements ... . .. . .. . ... ... . .. . .. . ... ... ... . .. . .. .15
5.5 Resistance measurements . ... ... . .. . .. . ... ... ... . .. . .. . ... ..16
5.6 Capacitance measurements . . ... ... . .. . .. . ... ... . .. . .. . ... ..16
5.7 Frequency measurements .. ... . .. . .. . ... ... . .. . .. . ... ... ... .17
5.8 Type K temperature measurements. ... ... . .. . .. . ... ... . .. . .. 17
5.9 Continuity . . ... ... . .. . .. . ... ... . .. . .. . ... ... ... . .. . ... ... ... . .. 17
5.10 Diode test ... . .. . .. . ... ... . .. . .. . ... ... ... . .. . .. . ... ... . .. . .. . .18
5.11 IR temperature measurements.. . .. . .. . ... ... . .. . .. . ... ... . .. 18
5.12 MAX/MIN mode.. . .. . .. . ... ... ... . .. . .. . ... ... . .. . .. . ... ... ... 20
5.13 Peak hold . . .. . ... ... . .. . .. . ... ... ... . .. . .. . ... ... . .. . .. . ... ... 20
5.14 Temperature units .. . .. . ... ... ... . .. . .. . ... ... . .. . .. . ... ... . .. 21
5.15 Streaming measurement data using Bluetooth . ... ... . .. . .. .21
6 Maintenance. .. . .. . ... ... . .. . .. . ... ... . .. . .. . ... ... ... . .. . .. . ... ... . .. . .23
6.1 Cleaning and storage.. ... . .. . .. . ... ... . .. . .. . ... ... ... . .. . .. .23
6.2 Battery replacement ... ... . .. . .. . ... ... . .. . .. . ... ... ... . .. . .. .23
#T559826; r. AD/ 9130/9130; en-US v
Table of contents
7 Technical specifications . ... . .. . .. . ... ... ... . .. . .. . ... ... . .. . .. . ... ...24
7.1 General specifications ... . .. . .. . ... ... . .. . .. . ... ... ... . .. . .. . .24
7.2 Electrical range specifications . ... ... . .. . .. . ... ... ... . .. . .. . .25
7.3 Thermal range specifications .. ... ... . .. . .. . ... ... . .. . .. . ... .28
7.4 Maximum input specifications.. . .. . .. . ... ... . .. . .. . ... ... ... .28
8 Technical support ... ... . .. . .. . ... ... . .. . .. . ... ... ... . .. . .. . ... ... . .. . .29
9 Warranties.. . .. . .. . ... ... ... . .. . .. . ... ... . .. . .. . ... ... . .. . .. . .. . ... ... . .30
9.1 FLIR Global Limited Lifetime Warranty . .. . .. . ... ... . .. . .. . ..30
9.2 FLIR Test and Measurement Limited 2 Year
Warranty. . .. . .. . ... ... ... . .. . .. . ... ... . .. . .. . ... ... . .. . .. . ... . 31
#T559826; r. AD/ 9130/9130; en-US vi

1 Disclaimers

1.1 Copyright

© 2013, FLIR Systems, Inc. All rights reservedworldwide. No parts of the software including source codemay be re­produced, transmitted, transcribed or translated into any language or computer language in any form orby any means, electronic, magnetic, optical, manualor otherwise, without the prior written permission of FLIR Systems.
The documentation must not, in whole or part, becopied, photocopied, reproduced, translated or transmitted to any electronic medium or machine readable form withoutprior consent, in writing, from FLIR Systems.
Names and marks appearing on the products herein are either registered trademarks or trademarks of FLIR Sys­tems and/or its subsidiaries. All other trademarks, trade names or company names referenced herein are usedfor identification only and are the property oftheir respective owners.

1.2 Quality assurance

The Quality Management System under which these products are developed and manufactured hasbeen certi­fied in accordance with the ISO 9001 standard.
FLIR Systems is committed to a policyof continuous de­velopment; therefore we reserve the right tomake changes and improvements on anyof theproducts with­out prior notice.

1.3 Documentation updates

Our manuals are updated several times per year, and we also issue product-critical notifications of changes on a regular basis.
Toaccess thelatest manualsand notifications, go to the Download tab at:
http://support.flir.com
It only takes a few minutes toregister online. In the down­load area you will also findthe latestreleases of manuals for our other products, aswell as manuals for our historical and obsolete products.

1.4 Disposal of electronic waste

As with most electronic products, this equipment mustbe disposed of in an environmentally friendly way, and in ac­cordance with existing regulations for electronic waste.
Please contact your FLIR Systems representativefor more details.
#T559826; r. AD/ 9130/9130; en-US 1

2 Safety information

Note
Before operating the device, you must read, understand, and follow all in­structions, dangers, warnings, cautions, and notes.
Note
FLIR Systems reserves the right to discontinue models, parts or accessories, and other items, or to change specifications at any time without prior notice.
Note
Remove the batteries if the device is not used for an extended period of time.
WARNING
Do not operate the device if you do not have the correct knowledge. Formal qualifications and/or national legislation for the electrical inspections can ap­ply. Incorrect operation of the device can cause damage, shock, injury or death to persons.
WARNING
Do not start the measuring procedure before you have set the function switch to the correct position. This can cause damage to the instrument and can cause injury to persons.
WARNING
Do not change to current or resistance when you measure the voltage. This can cause damage to the instrument and can cause injury to persons.
#T559826; r. AD/ 9130/9130; en-US 2
2 Safety information
WARNING
Do not measure the current on a circuit when the voltage increases to more than 600 V. This can cause damage to the instrument and can cause injury to persons.
WARNING
You must disconnect the test leads from the circuit that you did a test on be­fore you change the range. If you do not do this, damage to the instrument and injury to persons can occur.
WARNING
Do not look directly into the laser beam. The laser beam can cause eye irritation.
WARNING
Do not use the laser pointer near explosive gases or in other possible explo­sive areas. Injury to persons can occur.
WARNING
Do not replace the batteries or the fuses before you remove the test leads. This can cause damage to the instrument and can cause injury to persons.
WARNING
Do not use the device if the test leads and/or the device show signs of dam­age. Injury to persons can occur.
#T559826; r. AD/ 9130/9130; en-US 3
2 Safety information
WARNING
Be careful when you do the measurements if the voltages are more than 25 VAC rms or 35 VDC. There is a risk of shock from these voltages. Injury to per­sons can occur.
WARNING
Do not do diode, resistance or continuity tests before you have removed the power from capacitors and other devices under test during a measurement. Injury to persons can occur.
WARNING
Do not use the device as a tool to identify live terminals. You must use the cor­rect tools. Injury to persons can occur if you do not use the correct tools.
WARNING
Make sure that children cannot touch the device. The device contains danger­ous objects and small parts that children can swallow. If a child swallows an object or a part, speak with a physician immediately. Injury to persons can occur.
WARNING
Do not let children play with the batteries and/or the packing material. These can be dangerous for children if they use them as toys.
WARNING
Do not touch expired or damaged batteries without gloves. Injury to persons can occur.
#T559826; r. AD/ 9130/9130; en-US 4
2 Safety information
WARNING
Do not cause a short-circuit of the batteries. This can cause damage to the in­strument and can cause injury to persons.
WARNING
Do not put the batteries into a fire. Injury to persons can occur.
CAUTION
Do not use the device for a procedure that it is not made for. This can cause damage to the protection.
This symbol, adjacent to another symbol or terminal, indicates that the user must refer to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.
Double insulation.
UL listing is not an indication or a verification of the accuracy of the
meter

2.1 FCC Complicance

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential instal­lation. This equipment generates, uses, and can radiate radio frequency energy
#T559826; r. AD/ 9130/9130; en-US 5
2 Safety information
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be deter­mined by turning the equipment off and on, the user is encouraged to try to cor­rect the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
WARNING
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

2.2 Industry Canada compliance

This device complies with Industry Canada licence-exempt RSS standard(s). Op­eration is subjectto the following two conditions: (1) this device may not cause in­terference, and (2) this devicemust accept any interference, including interference that may cause undesired operation of thedevice.
#T559826; r. AD/ 9130/9130; en-US 6

3 Introduction

Congratulations on your purchase of the FLIR CM78 True RMS Clamp/DMM with infrared thermometer and Bluetooth METERLiNK®.
This meter is supplied in the METERLiNK® kit and includes a Bluetooth module designed for use with FLIR infrared cameras. The combination of a clamp meter and an infrared (IR) camera is used for electrical power measurement, analysis, and documentation.
The FLIR CM78 measurement functions include AC/DC voltage, AC/DC current, resistance, capacitance, frequency, diode test, continuity, type k thermocouple temperature plus non-contact IR temperature.
Proper use and care of this meter will provide many years of reliable service.

3.1 Key features

• True RMS current and voltage measurements.
• Multimeter functions include AC/DC voltage, resistance, capacitance, fre-
quency, diode, and continuity.
• 42 mm (1.7″) jaw opening; for conductors up to 2000 MCM.
• 4000–count backlit display.
• Built-in non-contact IR thermometer with laser pointer.
• Features include data hold, minimum/maximum, and auto power off.
• METERLiNK® Bluetooth transmitter wirelessly transmits voltage and current
readings to selected FLIR thermal imaging IR cameras, to incorporate meter readings with thermal images.
• Complete with CAT IV-1000V Professional Test Leads, 6 x AAA.
• FLIR CM78 METERLiNK® for Android app for remote meter reading.
• Safety Category Rating: CAT IV-600V, CAT III-1000V
#T559826; r. AD/ 9130/9130; en-US 7
Loading...
+ 29 hidden pages