FLIR AX8 Specifications

FLIR AX8
Thermal Imaging Camera For Continuous Condition and Safety Monitoring
FLIR A X8 is a thermal sensor with imaging capabilities. Combining thermal and visual cameras in a small, affordable package, the A X8 provides continuous temperature monitoring and alarming for of critical electrical and mechanical equipment.
The AX8 helps you guard against unplanned outages, service interruptions, and equipment failure. You’ll get the benets of continuous condition monitoring and hot spot detection without the need for periodic manual scans.
Compact and easy to install, AX8 provides continuous monitoring of electrical cabinets, process and manufacturing areas, data centers, energy generation and distribution, transportation and mass transit, storage facilities and refrigeration warehouses.
AUTOMATIC ANALYSIS AND ALARMS
With its streaming video output, the A X8 not only gives you live video of every installation, but it also provides automated alarming when pre-set temperature thresholds are exceeded as well as temperature trend analysis.
INDUSTRIAL PROTOCOL
Since FLIR AX8 is Ethernet/ IP and Modbus TCP compliant analysis and alarm results can easily be shared to a PLC. Digital inputs/outputs are available for alarms and control of external equipment. An image masking function allows you to select only the relevant part of the image for your analysis.
Loose Connection
Continuous monitoring of a motor.
COMPACT & EASY TO INSTALL
Combining thermal and visual cameras in a small, affordable package, the AX8 measures only 5 4 x 25 x 95 mm, making it easy to install in space­constrained areas for uninterrupted condition monitoring of critical electrical and mechanical equipment.
MULTIPLE VIDEO OPTIONS
With A X8, you can view its thermal imagery, visible light imagery, or the two combined into FLIR’s proprietar y, patent pending MSX multispectral dynamic imaging. MSX provides image detail from the visible camera embossed on the thermal image, giving you, sharper edge detail, the ability to read labels and better contextual awareness
www.flir.com
Technical specifications FLIR AX8
Imaging & Optical Data
IR resolution 80 × 60 pixels
Thermal sensitivity/NETD < 0.10°C @ +30 °C (+86°F) / 100 mK
Field of view ( FOV) 48° × 37°
Focus Fixed
Detector data
Detector t ype Focal Plane Array (FPA), uncooled microbolometer
Spectral range 7.5 –1 3 μ m
Visual camera
Built-in digital camera 640 × 480
Digital camera, FOV Adapts to the IR lens
Sensitivity Minimum 10 Lux without illuminator
Measurement
Object temperature range –10°C to +150°C (14°F to 302°F)
Accuracy
±2°C (±3.6°F) or ±2% of reading (+10 to +100C@+10 to +35 amb)
Measurement analysis
Spotmeter 6
Area 6 boxes with ma x./min./average
Automatic hot/ cold detection
Measurement presets Yes
Atmospheric transmission correction
Optics transmission correction
Emissivity correction Variable from 0.01 to 1.0
Reected apparent temperature correction
External optics/ windows correction
Measurement corrections Global object parameters
Max/Min temp. value and position shown within box
Automatic, based on inputs for distance,
atmospheric temperature and relative humidity
Automatic, based on signals from internal sensors
Automatic, based on input of reected temperature
Automatic, based on input of optics/window
transmission and temperature
Alarm
Alarm functions
Alarm output
Automatic alarms on any selected measurement
function. A maximum of 5 alarms can be set
Digital Out, store image, le sending
(ftp), email (SMT P), notication
Set-up
Color palettes Color palettes (BW, BW inv, Iron, Rain)
Set-up commands Date/time, Temperature °C/ °F
Web interface Yes
Storage of images
Storage media Built-in memory for image storage
Image storage mode IR, visual, MSX
File formats JPEG+FFF
Ethernet
Ethernet Control, result and image
Ethernet, type 100 M bps
Ethernet, standard IEEE 802.3
Ethernet, connector type M12 8-pin X-coded
Ethernet, video streaming Yes
Ethernet, power Power over Ethernet, PoE IEEE 802.3af class 0.
Ethernet, protocols
Et he r net /IP, M od bus T CP, TCP, UD P, SN T P, R TS P, RTP, HTT P, ICMP, IGMP, sftp, SM TP, SMB (CIFS),
DHCP, MDNS (Bonjour)
Image streaming
Image streaming formats Motion JPEG, MPEG, H.264
Image streaming resolution
Image modes
Automatic image adjustment
MSX (IR -image with enhanced detail presentation)
640 × 480
Thermal, Visual,
Continuous
Power system
External power operation 12/24V DC, 2 W continuously/ 3 .1 W absolute max
External power, connector M12 8-pin A-coded (Shared with digital I/O)
Voltage Allowed range 10.8 – 30 VDC
Environmental data
Operating temp. range 0°C to +50° C (32°F to +122°F)
Storage temp. range
Humidity (operating and storage)
EMC
Encapsulation IP67 (IEC 60529)
Bump 25 g (IEC 60068-2-29)
Vibration 2 g (IEC 6006 8-2-6)
–4 0°C to +70°C (–40° F to +158° F)
IEC 68 -2-1 and IEC 68-2-2
IEC 60 06 8-2-30/24 h 95% relative humidity +25°C to +4 0°C (+77° F to +104°F)/ 2 cycles
EN 61000-6-2:2001 (Immunity) EN 61000-6-3:2001 (Emission)
FCC 47 CFR Part 15 Class B (Emission)
Physical data
Camera size (L × W × H)
54 × 25 × 79 mm (2.1 x 1 x 3.1 in.) w/o connectors
54 × 25 × 95 mm (2.1 x 1 x 3.7 in.) w/ connectors
Shipping information
Packaging
FLIR Systems Trading Belgium BVBA
Luxemburgstraat 2 B-2321 Meer Belgium PH: +32 (0) 3 665 51 00
FLIR Systems, Inc.
9 Townsend West Nashua, NH 06063 USA PH: +1 866.47 7.3687
FLIR Systems AB
Antennvägen 6, PO Box 7 376 SE-187 66 Täby Sweden PH: +4 6 (0)8 753 25 00
Infrared camera with lens, printed documentation,
user documentation CD-ROM
FLIR Systems Ltd.
920 Sheldon Ct Burlington, Ontar io L7L 5K6 Canada PH: +1 800 613 050 7
FLIR Systems UK
2 Kings Hill Avenue - Kings Hill West Malling Kent ME19 4AQ United Kingdom PH: +4 4 (0)1732 220 011
www.flir.com flir@flir.com NASDAQ: FLIR
www.flir.com
Equipment described herein may require US Government authorization for export purposes. Diversion cont rary to US la w is prohibit ed. Imager y for illustr ation purp oses only. Sp ecificat ions are subje ct to chang e without n otice. ©20 14 FLIR Sy stems, Inc . All rights r eserve d. (Created 0 9/14)
Loading...