CONTENTS
Coffee maker 13
1 Safety and warnings 1
2 Parts supplied 2
3 Prior to installation 3
4 After installation 3
5 Product dimensions 4
6A Cabinetry dimensions
(460mm high cavity) 5
6B Cabinetry dimensions 
(480mm cavity trim kit) 6
7 Installation instructions 7
8 Final checklist 8
Steam oven 9
1 Safety and warnings 10
2 Parts supplied 11
3 Prior to installation 11
4 After installation 12
5 Product dimensions 13
6A Cabinetry dimensions
(460mm high cavity) 14
6B Cabinetry dimensions 
(480mm cavity trim kit) 15
7 Installation instructions 15
8 Final checklist 16
Microwave oven 17
1 Safety and warnings 18
2 Prior to installation 19
3 After installation 19
4 Product dimensions 20
5A Cabinetry dimensions
(460mm high cavity) 21
5B Cabinetry dimensions 
(480mm cavity trim kit) 22
6 Electrical hook-up 23
7 Secure the oven to the cabinetry 23
8 Final checklist 24
SAVE THESE INSTRUCTIONS
The models shown in this user guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website fisherpaykel.com or contact your local Fisher & Paykel dealer.

COFFEE MAKER

EB60 models
1SAFETY AND WARNINGS
IMPORTANT SAFETY INSTRUCTIONS!
Installation
WARNING!
Cut Hazard Take care – some edges are sharp. Failure to use caution could result in injury or cuts.
Checking for transport damage
After removing the packaging, make sure the product is complete and undamaged and that all accessories are present. Do not use the appliance if it is visibly damaged. Contact Customer Care.
IMPORTANT!
Installation must be performed by a qualified professional in compliance with legislation in force in the country of installation (see section “Built-in installation”).
The packing elements (plastic bags, polystyrene foam, etc.) should be kept out of reach of children.
Never install the appliance in rooms where the temperature may drop to 0°C or lower.
Customise the water hardness as soon as possible following the instructions in the “Water hardness” section.
This appliance can be installed over a built-in oven if the latter is fitted with a cooling fan at the rear (maximum microwave power: 3 kW).
Connecting the appliance
Danger! Check that the mains power supply voltage corresponds to the value indicated on the rating plate on the bottom of the appliance.
Connect the appliance to an efficiently earthed and correctly installed socket with a minimum current rating of 10A only.
If the power socket does not match the plug on the appliance, have the socket replaced with a suitable type by a qualified professional. To comply with safety directives, an omnipolar switch with a minimum contact distance of 3 mm must be installed.
Do not use multiple sockets or extensions.
Safety cutout devices must be included in the mains power supply in compliance with the installation regulations in the country concerned.
This appliance conforms to EC Regulation 1935/2004 on materials and articles intended to come into contact with food.
DISPOSAL
The appliance must not be disposed of with household waste, but taken to an authorised waste separation and recycling centre.
SAVE THESE INSTRUCTIONS
The models shown in this installation guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website fisherpaykel.com or contact your local Fisher & Paykel dealer.
2|COFFEE MAKER INSTALLATION GUIDE
2PARTS SUPPLIED
Screws
Rails (2) Lock Hook (1)
(28)
Spacers
(4) for side (4) for bottom
3PRIOR TO INSTALLATION
The countertop and coffee maker cavity are square and level, and are the required dimensions.
The installation will comply with all clearance requirements and applicable standards and regulations.
The isolating switch will be easily accessible to the customer with the coffee maker installed.
The electrician provides sufficient free length of power supply cable to reach from the bottom rear of the cavity to at least 1.5m in front of the bottom edge of the opening.
The cable may enter the cavity from the side, top or bottom, but top entry must be at the rear of the cavity.
The coffee maker connection socket (if fitted) is outside the cavity if the oven is flush to the rear wall.
The coffee maker will rest on a surface that can support its weight.
The height from the floor suits the customer.
You consult local building authorities and by-laws if in doubt regarding installation.
IMPORTANT!
Some environmental factors and cooking habits can cause condensation in and around the coffee maker during use. To protect surrounding cabinetry from possible damage caused by frequent or excessive condensation, we recommend moisture-proofing the cavity.
Clip (1)
Optional Trim kit installation
If you are using a 762mm trim kit, refer to the separate Trim Kit Installation Guide.
4AFTER INSTALLATION
IMPORTANT!
Take extra care not to damage the lower trim of the coffee maker during installation. The trim is important for correct air circulation and allows the door to open and close without obstruction. The manufacturer does not accept any responsibility for damage resulting from incorrect installation.
The coffee maker can be used fully without obstruction.
The power supply cable does not touch any hot metal parts.
The isolating switch is easily accessible to the customer with the coffee maker installed.
You complete the ‘Final checklist’ at the end of the installation.
If, after following the instructions given, correct performance cannot be achieved, please contact your nearest Fisher & Paykel Authorised Service Center, Customer Care, or contact us through our local website listed at the end of this document.
COFFEE MAKER INSTALLATION GUIDE|3
E
5PRODUCT DIMENSIONS
H
CF
I
A
TOP
B
FRONT
D
SIDE
PRODUCT DIMENSIONS
Overall height of product 458
A
Overall width of product 596
B
Overall depth of product 480
C
Height of chassis 445
D
Width of chassis 560
E
Depth of chassis 460
F
Depth of coffee maker frame and control panel 20
G
Stepdown control panel to chassis 13
H
Height of control panel 100
I
EB60 MODELS
mm
4|COFFEE MAKER INSTALLATION GUIDE
6ACABINETRY DIMENSIONS (460mm HIGH CAVITY)
Verify the minimum measurements required for correct installation of the appliance. The coffee maker must be installed in a column and the column must be firmly fixed to the wall with commercially available brackets.
IMPORTANT!
All installation or maintenance operations must be performed with the appliance disconnected from the mains electricity supply.
Kitchen furniture in direct contact with the appliance must be heat resistant 65°C min.
To guarantee correct ventilation, leave a gap at the bottom of the cabinet (see measurements below).
M
Lk
n
J
I
Electrical supply
TOPSIDE
PROUD INSTALL
16–20mm
20mm
FLUSH INSTALL
16–20mm
20mm
2mm
CABINETRY DIMENSIONS
EB60 MODELS
Minimum inside width of cavity 560
I
Overall width of cabinetry 600
J
Minimum inside height of cavity 450
K
Overall height of cabinetry 460
L
Minimum inside depth of cavity 545
M
Ventilation Air Gap 50
n
mm
COFFEE MAKER INSTALLATION GUIDE|5
6BCABINETRY DIMENSIONS (480mm CAVITY TRIM KIT)
Verify the minimum measurements required for correct installation of the appliance. The coffee maker must be installed in a column and the column must be firmly fixed to the wall with commercially available brackets.
IMPORTANT!
All installation or maintenance operations must be performed with the appliance disconnected from the mains electricity supply.
Kitchen furniture in direct contact with the appliance must be heat resistant 65°C min.
To guarantee correct ventilation, leave a gap at the bottom of the cabinet (see measurements below).
J
M
I
Electrical supply
PROUD INSTALL
16–20mm
20mm
n
Lower Trim kit
o
FLUSH INSTALL
16–20mm
Lk
20mm
TOPSIDE
CABINETRY DIMENSIONS
Minimum inside width of cavity 560
I
Overall width of cabinetry 600
J
Minimum inside height of cavity 470
K
Overall height of cabinetry 480
L
Minimum inside depth of cavity 545
M
Ventilation air vent 50
n
Height of trim kit
o
2mm
EB60 MODELS
mm
20
6|COFFEE MAKER INSTALLATION GUIDE
2 mm
x 28 x 2 x 1
(=)
(=)
2mm
7INSTALLATION INSTRUCTIONS
1 Position the rails on the sides of the
cabinet. Fix with the screws provided, then extend the rails completely.
Position and fix the lock hook with the four screws provided, as shown.
If the coffee maker is installed over a warmer drawer, use the top surface of this as a reference to position the rails. In this case, there will be no surface to rest the rails on.
approx. 350mm
2 Fix the power cable with the clip. The power cable must be long enough to allow
the appliance to be pulled out from the cabinet to fill the coffee bean container.
The appliance must be earthed in compliance with legislation.
Electrical connections must be performed by a qualified electrician following the instructions.
3 Position the appliance on the rails, making sure the pins are correctly inserted
in the housings, then fix it with the screws supplied. If the height of the appliance requires adjusting, use the spacer disks provided.
560mm + 1mm
4 If necessary, correct alignment of the appliance by positioning the spacers
supplied under or at the sides of the support.
5 To lift the appliance in the front (max. 2mm) turn the latch as shown.
COFFEE MAKER INSTALLATION GUIDE|7