Fisher Paykel OB24SCD7PX1, OB24SCD9PX1, OB24SCD11PB1 Installation Manual

BUILT-IN OVEN
OB24SC models
INSTALLATION GUIDE
US CA
59162B 12.18
1 SAFETY AND WARNINGS
WARNING!
Electrical shock hazard Before carrying out any work on the electrical section of the appliance, it must be disconnected from the mains electricity supply. Connection to a good ground wiring system is absolutely essential and mandatory. Alterations to the domestic wiring system must only be made by a qualified electrician Failure to follow this advice may result in electrical shock or death.
WARNING!
Fire hazard Do not use adapters, reducers, or branching devices to connect this appliance to the mains power supply. Failure to follow this advice may result in overheating, burning, or fire.
WARNING!
Cut hazard Take care - some panel edges are sharp. Failure to use caution could result in injury or cuts.
IMPORTANT SAFETY INSTRUCTIONS!
Save these instructions for the local inspectors use.
To avoid hazard, follow these instructions carefully before installing or using this appliance.
Please make this information available to the person installing the appliance - doing so could reduce your installation costs.
This oven is to be installed and connected to the electricity supply only by an authorized person.
If the installation requires alterations to the domestic electrical system, call a qualified electrician. The electrician should also check that the socket cable section is suitable for the electricity drawn by the oven.
The oven must be grounded.
Installation must comply with your local building and electricity regulations.
This appliance must be installed and connected to the mains power supply only by a suitably qualified person according to these installation instructions and in compliance with any applicable local building and electricity regulations. Failure to install the appliance correctly could invalidate any warranty or liability claims.
If the power supply cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid a hazard.
A circuit breaker is recommended.
Do not use adaptors, reducers or branching devices to connect the oven to the mains electricity supply, as they can cause overheating and burning.
Make sure the cavity is completely sealed with no gaps. This is to ensure the oven cooling system functions correctly.
The appliance must not be installed behind a decorative door in order to avoid overheating.
Electrical requirements
Connect oven with copper wire only.
Do not cut the conduit.
A U.L. listed conduit connector must be provided at the junction box.
Do not ground to a gas pipe.
Do not have a fuse in the grounding or neutral circuit.
Fuse both sides of the line.
A time delay fuse or circuit breaker is recommended. If using a time delay fuse, then fuse both sides of the line.
Flexible armored cable from the appliance should be connected directly to the junction box.
Connect directly to the fused disconnect (or circuit breaker box) through flexible, armored or non-metallic sheathed, copper cable (with grounding wire).
If codes permit and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path and wire gauge are in accordance with local codes.
IMPORTANT!
SAVE THESE INSTRUCTIONS
1
2 PARTS SUPPLIED
Screws (2) Metal side shelves
fixing nut (2)
3 PRIOR TO INSTALLATION
the countertop and oven cavity are square and level, and are the required dimensions.
the installation will comply with all clearance requirements and applicable standards and regulations.
the isolating switch will be easily accessible to the customer with the oven installed.
The electrician provides sufficient free length of power supply cable to reach from the bottom rear of the cavity to at least 1.5 metres in front of the bottom edge of the opening.
The cable may enter the cavity from the side, top or bottom, but top entry must be at the rear of the cavity.
the oven connection socket (if fitted) is outside the cavity if the oven is flush to the rear wall.
the oven will rest on a surface that can support its weight.
the height from the floor suits the customer.
you consult local building authorities and by-laws if in doubt regarding installation.
IMPORTANT!
Some environmental factors and cooking habits can cause condensation in and around the oven during use. To protect surrounding cabinetry from possible damage caused by frequent or excessive condensation, we recommend moisture-proofing the oven cavity.
4 AFTER INSTALLATION
IMPORTANT!
Please take extra care not to damage the lower trim of the oven during installation. The trim is important for correct air circulation and allows the door to open and close without obstruction. The manufacturer does not accept any responsibility for damage resulting from incorrect installation.
the oven door can open fully without obstruction.
Do not seal the oven into the cabinetry with silicone or glue. This makes future servicing difficult. Fisher & Paykel will not cover the costs of removing the oven, or of damage caused by this removal.
the power supply cable does not touch any hot metal parts.
the isolating switch is easily accessible to the customer with the oven installed.
you complete the ‘Final checklist’ at the end of the installation.
If, after following the instructions given, correct performance cannot be achieved, please contact your nearest Fisher & Paykel Authorised Service Centre, Customer Care, or contact us through our local website listed at the end of this document.
2
A
CF
B
E
G
H
D
5 PRODUCT DIMENSIONS
FRONT
TOP
SIDE
PRODUCT DIMENSIONS
A
Overall height of product 23 9/16” (598)
B
Overall width of product 23 7/16” (596)
C
Overall depth of product (excluding handle and dials) 22 1/4” (565)
D
Height of chassis 22 5/8” (575)
E
Width of chassis 21 7/8” (556)
F
Depth of chassis 21 7/16” (545)
Depth of oven frame and control panel
G
(=distance between front of chassis and front of oven door, excl. knobs)
Depth of oven door when fully open
H
(measured from front of control panel)
OB24SC MODELS
INCHES (MM)
13/16” (20)
18 1/8” (460)
3
I
J
K
L
M
Electrical supply
(16-20 mm)
5/8 - 13/16"
1/16"
(2 mm)
min.
13/16"
(20mm)
13/16"
(20mm)
(16-20 mm)
5/8 - 13/16"
5 CABINETRY DIMENSIONS
PROUD INSTALL
CABINETRY DIMENSIONS
Minimum inside width of cavity
I
Overall width of cabinetry
J
Minimum inside height of cavity
K
Overall height of cabinetry
L
Minimum inside depth of cavity
M
SIDE
TOP
OB24SC MODELS
INCHES (MM)
21 1/16” (560)
23 5/8” (600)
22 13/16” (580)
23 5/8” (600)
21 5/8” (550)
FLUSH INSTALL
Note: If installing a cooktop above the oven, ensure adequate clearance is provided for the cooktop as per the cooktop manufacturer’s instructions.
4
Remove the accessories box from the top of the oven and set aside.
6 DISCARD PACKAGING RESPONSIBLY
Recycle responsibly
5
Loading...