Fisher & Paykel DD603-88269, DD603-88270, DD603-88445-B, DD603FC-88449, DD603FC-88449-B Installation Guide

...
part number526607 N
Drawer
INSTALLATION INSTRUCTIONS
(NOTE:FOR INTEGRATEDPANELPREPARATIONINSTRUCTIONSREFERTOSUPPLIEDSHEET)
05/2005
(page1 ot 12)
DOUBLEDDC03 MODELS
DD603 PREFINISHED(shown left) DD603 FLATDOOR(not shown)
DD6031 INTEGRATED(shown right)
NOTE TOTHEINSTALLER
1. Readthese instructions completely and carefully.
2. Installation of this DishDrawer® requires basic mechanical and electrical skills.
3. Be sure to leave these Instructions with the Customer.
4. At the completion of the DishDrawer® installation, the Installer must perform Final Check List as per Section 12
of these Installation Instructions.
5. Remove all packaging materials supplied with the DishDrawer®.
6. This dishwasher is manufactured for indoor use only.
NOTE TOTHECUSTOMER
Keep these Installation Instructions with your User Guide for future reference, TheDishDrawer® must be securely
anchored before it is operated,
S_NGLE#$603 MO#ELS
I}S(O;_ PI_tttINI',<Ut[}(',_h>v/l_k.#t) DS603 FLAFDOOROsotshown)
DS6031 INIEGRAIED (sh>wl_light)
i_XWARNING!
Before installingthe DishDrawer® , remove thehouse fuseor open the circuit breaker.Ensure all water connectionsare turnedOFF. It is
the responsibilityof theplumber and electricianto ensurethat each installationcomplieswith all CodesandRegulations.
Important!
Theseinstructionsmustbe followed precisely toensure correct venting andoperation ofthe DishDrawer@. In the event ofa fault
related tothe incorrectinstallation, theinstaller will be liable for any repairs.
Important!
TheDishDrawer® MUST be installed toallow for futureremoval
fromthe enclosure if serviceis required.
Important!
Improperinstallationis not covered underthe Warranty.
Important!
If the DishDrawer® is to be relocated fromone installationto anotherit mustbe keptuprightto avoid damagefrom water spillage.
,,- BEFOREYOUSTART- DOUBLE& S/NG£E MODELS
|_ft_k"]!,_lP.,P.,ill.'ll]
r
DOUBLEMODELS
F
%NGLEMODELS
DishDrawer ®
E_.... : ......... __ _ ...........
FlexibleExtrusion FlexibleExtrusion forSides (2) for Top(7)
EdgeProtector (7)
Clamp
(7) Washer
@)
Installation Tabs(2)
Phillips 76mm Screws (7)
Moisture
Drain Hose DrainHose Wire Support (7) Joiner (7) Clips(2)
Protection
Tape(1)
p/n 527208
ToeKick (I) Prefinished
Whiteprefinishedtoe kick kit pin 526678 or Blackprefinished toe kickkitpin 526679 or Iridiumprefinished toekick kit pin 527109
J
lllVk_lP.fl l,.lll [llArl ,.Itlll ,.i,.It!,.lll[lllv|
ELECTRICALPREPARATION
,4) Theswitched power outlet mustbe outsidethe DishDrawer®
cavity so that it is accessibleafter installation,
B) Theswitched power outlet must be between 6" (150mm)and
18" (450mm)from the DishDrawer® cavity.
¢) Referto Page9, Step5for electricalconnectionoptions,
Important!
The services hole in the DishDrawer® cavityneedsto be large
enoughfor the plugon the power supply cordto fit through,but MUST NOTbe morethan 11/{' (38ram).
PLUMBING & DRAINAGE PREPARATION
,4) A readilyaccessiblevalve must be installed in the water supply pipe.
B) If the supplypressureexceeds145psi (lO00kPa),then apressure
limiting valvemust be used,
C) Review PlumbingOptionson pages4 or6. Chooseamethodthat best
suitsyour needs,
D) A DrainHoseextension KitP/N525798 will extendthe drainhoses
by 1413/4"(3,6m), Thekit is availablefrom the nearestFisher&Paykel AuthorizedServiceAgent, DONOTextend beyondthis limit,
E) This Dishwasher'smaximumdrain heightis 37//2" (950mm).
iMm <::' !!!!!!!!!!!!!!!!I_=_'_=_'"_'"_"_";'Phillips 1ram
[tolllo_ (1)
L}_aklllos_
Pm ction
Iq_x%I Exuz s_o,_Ic>_Skl s (?)
I[eIe]!._r#lIlln]llnJ
Wooden Chopping Board Tape Measure
Spirit Level Safety Glasses
Utility Knife Pencil
Sandpaper
SPAREPARTS INSTALLATION KIT FORSINGLE& DOUBLE MODELS: pin 526676
CAVITY PREPARATION
,4) It is recommended that all cabinetry surroundingthe DishDrawer®
(includingthe undersideof the countertop)is sealedwith anoil based paintor moisture-proofpolyurethaneto prevent possiblesteam damage, Theair in the cavity can get very hot andhumid(saturated
at 122°F/50°C)
B) Theself-adhesivemoisture protection tape must beappliedto the
undersideof the countertopto preventmoisture damage,(referto cavity diagram pg 3or 5), Besure surfacesaredry and dust-free prior to application.
C) Be surethe cavity providessufficient materialto securetheDishDrawer®
using the mountingtabs (referto step 1, page7). Ifthere is nothing to screw to, add a brace. Seepage3 or 5 for screw locations,
D) The servicesholeMUST be immediatelyadjacent to the rearlower
cornerof the cabinetry, If not, the hoseswill preventthe DishDrawer® being pushedback into the cavityallthe way, Thehole can belocated oneither side dependingon the location of the
services.
E) Be surethe cavity sidesare plumb (vertical)as this will assistwith
levellingthe DishDrawer®,
F) Minimum clearances:
Vs" (2,5mm)LIL
Drill& No.2Phillips Bit No,2Phillips Screwdriver FlatScrewdriver
AdjustableWrenchor M5 Socket
011/2" (38mm)HoleSaw
SideCutting Pliers
e___lV.,'[_Jltl[_f|llVl,fl]tlA_V.,ll[IAw
POWER SUPPLY CORD ,4) Care should be taken when the appliance is installed or
removed to reduce the likelihood of damage to the power supply cord,
B) If the power supply cord is damaged, it must be replaced by
the Manufacturer, Service Agent or a similarly qualified person in order to avoid a hazard,
GROUNDING INSTRUCTIONS
,4) Thisappliancemust begrounded. Inthe event of malfunctionor
breakdown,groundingwill reducethe risk of electric shock by providinga pathof leastresistancefor electriccurrent.
1/s" (2,5mm)
V2" (13mm)
Z_WARNING!
Improperconnectionof the equipment-groundingconductorcan result in a risk of electric shock. Check with a qualifiedelectricianor
servicerepresentativeif youare indoubtas towhether the appliance is properlygrounded.
B) Thisapplianceis equippedwith a power supplycord having an
equipment-groundingconductorand an earthingplug, Thepower supply plug mustbe pluggedinto an appropriateoutlet that is installed
andearthedin accordancewith all local CodesandOrdinances,
Z_WARNING!
Donot modifythe power supplyplugprovidedwith the appliance- if it will not fit the outlet, havea properoutlet installedby a qualified
electrician. Do notusean extensioncord,adaptorplugor multiple outletbox.
,._ DOUBLEMODELS
DishDrawer ®
WATER CONNECTION
RecommendedHOT (Maximum140°F/60°C).
Suppliedhoseto suit 3/8"(9ram) malecompressionfitting,
WATER SOFTENER MODELS Referto your DishDrawer®UserGuidefor
how to set upyour water softener.
WATER PRESSURE
WaterSoftenerModels OtherModels
DRAIN CONNECTION
DrainHoseJoiner to suit 03/4" _+ 5/64", 05/8" + 5/64" and
_31"_+5/64"waste tees,
ELECTRICALCONNECTION
110-120VACpower outlet, 9 Amps Minimum,
LENGTH OF SERVICES(FROMPRODUCTEXITPOINT} Drainhose- 889/16" (2250mm) Inlet hose- 687/8"(I 750ram) Powersupplycord- 44" (l125mm)
NOTE: Services approximately exit product 77/16" (189mm) from left; 215/8" (550ram) from front; 311/4'' (793mm) from top,
Maximum 145p,s.i, (1000kPa)
145p,s,i, (1000kPa)
Minimum 14,5 p,s,i. (lOOkPa) Refinished modelshown
4,3 p.s.i, (30kPa)
Vl#ll _lrJll'd
5/16- I_-
mm/ I,
* Foran IntegratedDishDrawer® the (50-1lOmm) productdepth is specifiedwith an
11/16" (18mm)IntegratedPanelthickness.
*_ Depthof productexcludes Curvature(13/16,, (30mm)Prefinishedonly,)
t TOE KICK DEPTH
Prefinished & Flat Door 2"-43/8"(50-110mm); Integrated 5" (127mm) lessthe ToeKick Panelthickness. Minimum Panel
thicknessusingthe suppliedscrews is 3/8"(gmm). # DOOR FRONT HEIGHT
Prefinished & Flat Door 305/64" (764mm); Integrated 281/4'' (717.Smm)minimum.
227/16" (570mm)
Side View ° __2015/_,,_ _ :
or Handle.
"227/16" 237/16"
(570turn) _
(520rnm) k-"'----_
Drawer Open
2" _ _3/8" _
_Lo
4 5/16"
(109.5mm)
Min thickness
of cavity sides
is 5/8" (16ram)
3 13/16_'/
(97mm)
Screw 9/16" (14mm) from front of cabinetry
\
. can be either side
i adjacent to corner,
Moisture Protection
Tape
011/2" (38mm)
services hole
immediately
1/2"
(13mm)
countertop
1/2" (13mm)
Thesemarksindicate mountingtab screw
locations(referto step 1 page 7)
NOTE: All depth measurements are taken
from the front face of the adjacent cabinetry.
22 7/8" (580mm)
throughout cavity
/
23 %" (600mm)
Z_WARNING!
Be sure the edgesof the services hole are smooth or covered. If the services
holeis througha metal partitionthe hole must be protectedwith the EdgeProtector providedto preventdamageto the power
cord or hoses.
._ DOUBLEMODELS
1_'21Oh_lXfld[efe]Ml[e]=vi,1
DishDrawer ®
OPTION1 DishDrawer®andStandpipe011/2"(38mm)with AirGap,
VALVE WATER
BEND RADIUS FROM VALVE
SUPPLY
MINIMUM
II qll JI
]
minimum
DISPOSAL
WASTE
WATER SUPPLY
BEND RADIUS FROM VALVE
MINIMUM
OPTION 2
DishDrawer®with Waste Disposal.
ii _uRBREAK _i ii
OUTLET _ H WATER
NOTE." Prefinished Model is shown, There is no variation in plumbing between models, Option 1 is the preferred option, Drains will need to be separated to satisfy Kosher
requirements, We suggest you confirm acceptability with
your local Rabbi in respect to Kosher installations,
OPTION 3 DishDrawer® usingAir Breakwith DrainHose Joiner,
_J _o
x < o
Loading...
+ 8 hidden pages