Electrical Shock Hazard
Before installing the dishwasher, remove the house fuse or open the circuit
breaker. If permanently connecting the dishwasher, be sure the power is
isolated and the dishwasher unplugged.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of a malfunction or breakdown,
grounding will reduce the risk of electric shock by providing a path of least
resistance for electric current. This appliance is equipped with a cord having
an equipment-grounding conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is installed and grounded in
accordance with all local codes and ordinances. WARNING - Improper
connection of the equipment-grounding conductor can result in a risk of
electric shock. Check with a qualified electrician or service representative if
you are in doubt as to whether the appliance is properly grounded.
If the dishwasher is installed as a permanently connected appliance:
GROUNDING INSTRUCTIONS - This appliance must be connected to a
grounded metal, permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and connected to the
equipment-grounding terminal or lead on the appliance.
Do not modify the power supply plug provided with the appliance - if it will
not fit the outlet, have a proper outlet installed by a qualified electrician. Do
not use an extension cord, adapter plug or multiple outlet box.
Failure to follow this advice may result in electrical shock or death.
IMPORTANT SAFETY INSTRUCTIONS
●
Installation of this dishwasher requires basic mechanical and electrical skills.
●
Be sure to leave these Instructions with the Customer.
●
Installation must comply with your local building, electricity, and plumbing regulations.
●
At the completion of the dishwasher installation, the Installer must perform the Final
Checklist.
●
Remove all packaging materials supplied with the dishwasher.
●
This dishwasher is manufactured for indoor use only.
●
Ensure all water connections are turned OFF. It is the responsibility of the plumber and
electrician to ensure that each installation complies with all Codes and Regulations.
●
The dishwasher MUST be installed to allow for future removal from the enclosure if service
is required.
●
The switched power outlet must be outside the dishwasher cavity, so that it is accessible
after installation.
●
Care should be taken when the appliance is installed or removed to reduce the likelihood
of damage to the power supply cord and hoses.
●
If the dishwasher is to be relocated from one installation to another it must be kept
upright to avoid damage from water spillage.
●
Make sure only new hoses are used for connection (supplied with the dishwasher). Old
hoses should not be reused.
●
Failure to install the dishwasher correctly could invalidate any warranty or liability claims.
●
If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring
the vehicle, boat or mobile facility containing the product to the service shop at your
expense or pay the service technician’s travel to the location of the product.
●
This dishdrawer is intended for connection to the hot-water supply.
●
Failure to install the dishwasher correctly could invalidate any warranty or liability claims.
!
WARNING!
Fitting integrated front panels requires access to electrical service areas.
This work must be performed and certified by a qualified electrical service technician.
Electrical Shock Hazard
WARNING: To reduce the risk of electrical shock, fire, or injury to persons, the
installer must ensure that the dishwasher is completely enclosed at the time
of installation.
Before fitting the front panels and connecting the ‘knock to pause’ module (if
necessary), the installer must ensure that the dishwasher is disconnected from
the power supply.
After installing the front panels, the installer must ensure that the following
components are electrically grounded: the panel bracket and any custom
metal component (e.g. handle) that extends past the rubber seal.
Failure to follow these warnings may result in electrical shock, injury or fire.
!
WARNING!
Cut Hazard
Take care - panel edges are sharp.
Failure to use caution could result in injury or cuts.
1
●
Ensure the product is not plugged in when fitting custom panels.
●
Installation of custom panels requires basic mechanical and electrical skills.
●
Installation must comply with your local building and electricity regulations.
●
Failure to install the custom panels correctly could invalidate any warranty or liability
claims.
IMPORTANT!
SAVE THESE INSTRUCTIONS
The models shown in this installation guide may not be available in all markets and are subject to
change at any time. For current details about model and specification availability in your country,
please go to our website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.
2 PARTS SUPPLIED
Drain hose
support (1)
Phillips
5/8” (16mm)
screws (9)
Drain hose
joiner (1)
for inlet hose (1)
(comes already
fitted)
Wire clip (2)
(for securing
Drain hose joiner)
Moisture protection
tape (1)
(to prevent moisture
damage to cabinetry)
Clamp (1)
(for securing
Drain hose joiner)
Hexagonal
socket for feet
adjustment (2)
(long & short)
Side mounting
bracket kit
(A and B) (2)
OPTIONAL
Prefinished toekick (1) Rubber washer
Top
mounting
brackets (2)
OPTIONAL
Edge Protector (1)
(If the services hole
is through a metal
partition, the hole must
be protected with the
Edge Protector supplied
to prevent damage to the
power cord or hoses.)
Panel bracket (2)
& Knock-to-Pause Module (2)
(shipped fixed to product)
If the Drain hoses supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain
hoses by 11’ 10” (3.6m). The kit is available from the nearest Fisher & Paykel Authorized Service Center, or Toll free 1.888.936.7872 or www.fisherpaykel.com
Panel mounting
screws (12)
Toekick mounting bracket cutting
template (1)
(To enable a custom toekick panel to be
cut to fit the product profile dependant
on the depth of the toekick )
Toekick mounting bracket (1)
(A custom toekick panel of any
material with thickness 3/8”- 3/4”
(9 - 19mm) can be screwed to the
Toekick mounting bracket)
Toekick
mounting
screws (5)
2
3 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION
3-A REMOVE THE LOWER DRAWER3-B REMOVE THE ACCESS COVER & REMOVE POWER
To prevent kinked hoses
Either sit the drawer down on the left
hand side (recommended) or rotate the
drawer clockwise, resting it on its side after
removal.
3
1
2
4” (100 mm)
Press the release tabs
in on either side and
push back to release
drawer from runners.
Lift drawer off runners.
4
Push drawer
runners back in
on either side.
4
Push drawer
runners back in
on either side.
3
Sit the drawer down
3
Rotate the drawer
clockwise (max. 90
and rest on side.
Clip
1
Clip
1
Access cover
1 With a flat-bladed screwdriver, push
in the clips and slide out the access
cover.
2 Unscrew the electronics module
cover.
3 Carefully pull out the electronics
module and rest on the chassis base
out of the way.
4 With a screwdriver, unclip the plastic
harness cover and hinge open.
5 Slide the terminal block cover
sideways to unlock and hinge open
to access the terminal block.
6 Unscrew the Live, Neutral and Earth
wires as shown.
7 Unscrew the three screws on the
base as shown and remove the cord
o
)
from the product.
4
6
5
Remove existing
power cord
7
2
Electronics
module
Terminal
Block cover
7
3
3-C TERMINATE MAINS WIRING AS SHOWN AND REPLACE MODULE AND COVERS
8
9
IMPORTANT!
Ensure the mains wires are routed
UNDERNEATH all other harness
wiring from the electronics module.
3 OPTIONALLY HARD WIRING PRIOR TO INSTALLATION
12
13
11
10
14
8 Fit a suitable cable clamp for the
conduit through the metal knockout.
Ensure wiring is routed through or
under under housing ribs.
9 Screw down the Live, Neutral and
Earth wires correctly.
10 Push the plastic harness cover back
over. It should clip back into place
11 Fold down and slide back the
terminal block cover.
12 Refit the electronics module back
into position, being careful of wiring.
13 Replace the screw securing the
electronics module.
14 Slide the access cover back,
ensuring the 2 clips shown are fully
locked in place.
NOTE: Use copper conductors
only.
Before refitting the
drawer, ensure the hoses
are not twisted and the
latches at the rear of
each drawer runner are
facing forward.
2
3-D REFIT THE DRAWER ONTO THE RUNNERS & CLOSE
Lift or rotate counter-clockwise the
drawer back onto the drawer runners
on either side.
4” (100 mm)
3
1
Release tab
4
Pull the release tabs forward on both
sides 4” (100 mm). Ensure the tabs are
fully pulled forward and click into place.
4
H
4 PRODUCT DIMENSIONS
C
G
A
F
J
I
K
L
PROFILEFRONT
M
STANDARD
HEIGHT
MODELS
DD24DI
PRODUCT DIMENSIONS INCHES (MM) INCHES (MM)
Overall height of product
A
B
D
E
N
5
PLAN
Overall width of product
B
Overall depth of product
C
Depth of chassis (to back of front drawer panel)
D
Depth of drawer front panel
E
Height of chassis
F
Height of drawer front panels
G
Height of upper drawer front panel
H
Height of lower drawer front panel
I
Ventilation gap between drawer front panels
J
Height of toekick (customisable)
K
Depth from front of drawer panel to front of toekick (adjustable)
L
Height of leveling feet (adjustable)
M
Maximum extension of drawer
N
1
includes 1/16” (2mm) high bracket slots 2 depending on adjustment of leveling feet 3 assuming front panel thickness of 11/16” (18mm)
4
adjustable to match toekick recess on adjoining cabinetry
5
assuming custom toekick panel thickness of 11/16” (18mm); if recess is between 1 15/16”-3 5/16” (50-84mm) deep, the panel will need to be cut out -
min. 1/2” (13 mm)
clearance from a
corner cupboard
min. 1/16” (2 mm)
clearance
to adjacent
cupboard door
6
6 CUSTOM DRAWER PANEL SPECIFICATIONS
FRONT PANEL MATERIAL SPECIFICATIONS
●
5/8 - 13/16” (16 - 20mm) panel thickness.
●
Adequately sealed to withstand moisture (122OF/50OC @ 80% RH)
Because of it being a hot and wet environment generally, the back and sides of the
panel should be completely sealed with a waterproof vapor barrier (ie polyurethane)
to prevent damage to the panel.
●
The back of the panel (including any integrated handle) should be completely flush
so that the seal between the panel and the rubber trim is maintained.
●
Installation outside these specs may result in condensation on cabinetry surfaces.
●
Maximum weight of each panel: 20lb (9kg)
The following calculations assume the top of the upper panel is
aligned with the top of the adjacent cabinetry.
The final panel/cabinetry alignment is achieved by adjusting the feet:
WIDTH OF ALL PANELS
Measure A(the width between adjacent door/drawer fronts)
and write it in the first box below, then complete the equation.
Note: The ‘upper panel extension’ B
allows for the top of the upper panel to
extend above the chassis where required,
however a min. 1/16” (2mm) gap to
the countertop must be maintained.
min. 1/16”
(2mm)
B
Clearance to adjacent
A
cabinet front
- 2x=
(min. 1/16” (2mm))
HEIGHT OF THE UPPER PANEL
Minimum height
DD24DI models:
15 11/16”
DD24DTI/DD24DHTI models:
17 3/8”
Note: The ‘upper panel extension’ B allows for the top of the upper
panel to extend above the chassis where required, however a
min. 1/16” (2mm) gap to the countertop must be maintained.
HEIGHT OF THE LOWER PANEL
Measure C(door/drawer height (or equivalent)) and write it in the
first box below, then complete the equation.
(398mm)
(442mm)
Upper Panel extension
+
(0”/0mm recommended)
B
C
DD24DI models:
(min 28 1/4” (717mm) +
DD24DTI/DD24DHTI models:
(min 30” (762mm) +
7
B)
Height of
Upper Panel
--
B)
Ventilation Gap
(min. 5/16” (8mm))
(23 7/16”-24 3/16” (596-615mm))
WIDTH OF PANEL
HEIGHT OF
UPPER PANEL
=
HEIGHT OF
LOWER PANEL
=
(min. 12 1/4” (311mm))
min. 1/16” (2mm)
C
A
UPPER PANEL
LOWER PANEL
TOEKICK PANEL
WIDTH OF ALL PANELS
min. 1/16” (2mm)min. 1/16” (2mm)
HEIGHT OF
UPPER PANEL
Ventilation Gap
(min. 5/16” (8mm))
HEIGHT OF
LOWER PANEL
7 CUSTOM TOEKICK PANEL SPECIFICATIONS
TOEKICK PANEL MATERIAL SPECIFICATIONS
●
min. 3/8” (9mm) panel thickness if using supplied screws
●
Adequately sealed to withstand moisture (122OF/50OC @ 80% RH)
●
You may choose to affix your custom toekick panel either by screwing
it or gluing it to the supplied mounting bracket.
HEIGHT OF THE TOEKICK PANEL
Measure D(height from the top of adjacent cabinet door fronts to the floor)
and write it in the first box below, then complete the equation.
D
B
Upper Panel
extension
(0”/0mm
recommended)
height from top
of product to
toekick panel
mounting point
DD24DI models:
29 1/2”
31 1/4”
(750mm)
DD24DTI/DD24DHTI models:
(794mm)
Clearance to floor
(min. 1/2” (12mm))
HEIGHT OF
TOEKICK PANEL
=---
(min. 2 1/4” (58))
Toekick Depth
Depth is measured from FRONT of door panel
(assuming thickness ~ 11/16” (18mm) to front
face of custom toekick label
NO CUTOUT
CUSTOM TOEKICK PANEL
For a Toekick Depth
1 9/16” (40mm)
Height from top
of product to
toekick panel
mounting point
DD24DI models:
D
29 1/2”
DD24DTI/DD24DHTI models:
31 1/4”
(750mm)
(794mm)
Toekick mounting bracket
cutting template:
PROFILE A
CUSTOM TOEKICK PANEL
For a Toekick Depth
1 9/16” - 3 7/16”
(40mm - 88mm)
Toekick mounting bracket
1 9/16” (40mm)
1 9/16” - 3 7/16”
(40mm - 88mm)
cutting template:
PROFILE B
CUSTOM TOEKICK PANEL
HEIGHT OF
TOEKICK PANEL
Clearance to floor
(min. 1/2” (12mm))
For a Toekick Depth
3 7/16” - 3 15/16”
(88mm - 100mm)
3 7/16” - 3 15/16”
(88mm - 100mm)
8
COUNTERTOP
3/8”
(10 mm)
Moisture
protection
tape must
be applied.
8 CAVITY PREPARATION
IMPORTANT!
The power outlet
must be located in a
cabinet adjacent to the
dishwasher cavity.
110-120 VAC max. 15 A
Water Connection
Recommended HOT
(Maximum 140°F/60°C).
Supplied hose to
suit 3⁄8” (9 mm) male
compression fitting.
These marks indicate
formed bracket screw
locations, if securing by
drawer removal.
If there is no side
partition, you can
construct timber
bracing as something
to secure into.
Services hole
Can be located either side of dishwasher, preferably
at the bottom of the cavity, as shown. If adequate
clearance, services hole can be made higher to clear
toekick space. If hole is higher, ensure drain hose(s)
are routed straight into the waste connection.
●
If the hole is through wood, make sure its edges are
smooth and rounded.
●
If the hole is through metal, ensure you fit the supplied
Edge Protector to prevent damage to the power cord.
9
ø max. 1 1/2”
(38 mm)
max. 17 11⁄16”
(450 mm)
Water Pressure
Water softener models
Max. 1 MPa (145 psi)
Min. 0.1 MPa (14.5 psi)
Models without water softener
Max. 1 MPa (145 psi)
Min. 0.03 MPa (4.3 psi)
Kosher requirements
Drains will need to be
separated to satisfy
kosher requirements.
We suggest you confirm
acceptability with your
local rabbi in respect to
kosher installations.
min. 7 7⁄8” (200 mm)
9 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE
!0-A ATTACH SIDE MOUNTING BRACKETS!1-A PULL THROUGH HOSES & PUSH INTO THE CAVITY
Clip all four side mounting brackets
into their slots using a flat-bladed
screwdriver. Ensure they’re securely
fitted before sliding product into cavity.
AB
optionally attach the
two top mounting
brackets
(x2)
Initially level the product
When fitting brackets,
ensure the ends are
not pushed down into
the chassis.
B
A
A
B
A
The mounting slots are in pairs, one on
each side diagonally across the product.
A bracket must match A slot and B
bracket must match B slot.
When fitting brackets, ensure the
ends are not pushed down into
the chassis.
11
B
You can raise or lower
the product by twisting
the feet. Then take
care when pushing the
product into the cavity
that you do not bend the
feet.
As you push product
in, pull through hoses
and cord, ensuring
they don’t get kinked
or twisted.
!2-A SECURE TO THE CABINETRY ON THE SIDES
!3-A OPTIONALLY SECURE TO THE CABINETRY ABOVE
Using a small
Philips screwdriver,
screw through the
trim moulding,
securing the side
mounting bracket
to the cabinetry.
Do not damage
the rubber
trimseal.
Open the
drawer halfway.
Using a flat
bladed
screwdriver,
prise the gray
rubber plug out
of the trim
moulding.
2
Repeat for all
four brackets.
1
Replace the gray
rubber plug back into
the trim moulding
and ensure the trim
seal is facing forward.
The top mounting
brackets will only
(x2)
bend upwards a
maximum of 3⁄8”
(10 mm).
3
!4-A AFTER SECURING, REFER TO ‘FIT THE SUPPLIED TOEKICK PANEL’ STEP
12
!0 ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL
!0-B PULL THROUGH HOSES & PUSH INTO THE CAVITY!1-B REMOVE THE LOWER DRAWER
optionally attach the
two top mounting
brackets
(x2)
Initially level the product
You can raise or lower
the product by twisting
the feet. Then take
care when pushing the
product into the cavity
that you do not bend the
feet.
13
When fitting brackets,
ensure the ends are
not pushed down into
the chassis.
As you push product
in, pull through hoses
and cord, ensuring
they don’t get kinked
or twisted.
1
2
4” (100mm)
Press the release tabs
in on either side and
push back to release
drawer from runners.
Lift drawer off runners.
To prevent kinked hoses
Either sit the drawer down on the left
hand side (recommended) or rotate the
drawer clockwise, resting it on its side after
removal.
3
4
Push drawer
runners back in
on either side.
Sit the drawer down
3
4
Push drawer
runners back in
on either side.
Rotate the drawer
clockwise (max. 90
and rest on side.
o
)
!2-B SECURE TO THE CABINETRY ON THE SIDES!3-B OPTIONALLY SECURE TO THE CABINETRY ABOVE
For further adjustment,
using the most appropriate
length Hexagonal socket
supplied, fully extend
levelling feet up to
required distance by hand.
Secure using two pairs
of formed brackets.
Repeat on the other
side of the chassis.
(x2)
The top mounting
brackets will only
bend upwards a
maximum of 3⁄8”
(10 mm).
x4
Before refitting the
drawer, ensure the hoses
are not twisted and the
latches at the rear of
each drawer runner are
facing forward.
Hexagonal
socket
2
Ensure product is level and
aligning with cabinetry.
1
!4-B REFIT THE DRAWER ONTO THE RUNNERS
Lift or rotate counterclockwise the
drawer back onto the drawer runners
on either side.
3
4
4” (100mm)
Pull the release tabs forward on both
sides 4” (100mm). Ensure the tabs are
fully pulled forward and click into place.
Release tab
14
!5 INSTALLING CUSTOM FRONT DRAWER PANELS
1
1
!5-B REMOVE BOTH PANEL BRACKETS FROM PRODUCT
WARNING!
Side Pin
1
Remove side pins and gently
pull off the panel bracket
slightly.
Electrical Shock Hazard
Before continuing, ensure that the product is
disconnected from the power supply.
Failure to follow this warning may result in
electrical shock, injury or fire.
2
1
!5-B REMOVE THE KNOCK-TO-PAUSE MODULE
Knock-to-Pause module
Repeat for the other drawer.
1 Disconnect the Earth Wire
from the bracket
2 Unplug the knock sensor
from the controller.
Repeat for the other drawer.
15
Remove the Knock-to-Pause
module from the back of the
bracket.
Repeat for the other bracket.
3