Fisher & Paykel CG603D, CG302D, CG604D, CG903D, CG451D User Manual

...
INSTALLATION INSTRUCTIONS
Gas-on-glass cooktop
CG302D, CG451D, CG603D, CG604D,
CG752D, CG903D & CG905D
models
NZ AU
590149D 02.13
1
SAFETY AND WARNINGS
2
WARNING!
Electrical shock hazard
Before carrying out any work on the electrical section of the appliance, it must
be disconnected from the mains electricity supply.
Connection to a good earth wiring system is absolutely essential and mandatory.
Alterations to the domestic wiring system must only be made by a qualified electrician.
Failure to follow this advice may result in electrical shock or death.
WARNING!
Cut hazard
Take care - some panel edges are sharp.
Failure to use caution could result in injury or cuts.
IMPORTANT SAFETY INSTRUCTIONS!
Particular attention shall be given to the relevant requirements regarding ventilation. Read these instructions carefully before installing this product. Please make this information available to the person installing the appliance as it could reduce your installation costs. This appliance is to be installed and serviced only by an authorised person. Installation must comply with your local building and local gas authority codes and electricity regulations. Incorrect installation, for which the manufacturer accepts no responsibility, may cause personal injury or damage and could invalidate any warranty or liability claims. These appliances are registered in: (New Zealand) at www.energysafety.govt.nz and (Australia) with SAI Global at www.saiglobal.com. This gas appliance is suitable for connection only to the gas type for which it was set at the factory, as declared on the appliance data label. It is not convertible for use on any other gas type. If in doubt, refer to the local gas network operator or gas supplier to confirm gas type at installation site. Do not modify this appliance.
Do not use or store flammable materials on or near this appliance. Do not spray aerosols in the vicinity of this appliance while it is in operation. Packing elements (eg plastic bags, polystyrene foam, staples, packing straps etc) and tools should not
be left around during and after installation, especially if they are within easy reach of children, as these may cause serious injuries.
You must remove the transit screws before installing the cooktop. See step 8 of installation
instructions.
Before you install the appliance, please make sure that
the local distribution conditions (nature of gas and pressure) and the adjustment of the appliance are compatible. For adjustment conditions for this appliance see ‘Gas rate summary’. a suitable disconnection switch is incorporated in the permanent wiring, mounted and positioned to comply with the local wiring rules and regulations. A means of disconnection with at least a 3 mm air gap contact separation in all poles must be incorporated into the fixed wiring in accordance with the wiring rules, unless the local wiring rules allow for alternative means. the appliance is connected to a 220V - 240V 50Hz (10 A) power supply only and earthed via the power supply cable.
there is a power outlet within reach of the power supply cable (900 mm from the centre rear of the product). This must be accessible after installation. The power supply cable should not touch any metal parts.
if the power supply cable is damaged, it is replaced only by the special cable: Part no. 534050 - Flex Terminal Block Assy NZ/AU, obtainable from authorised Fisher & Paykel Service Agents.
the supply connection point (gas shut-off valve) is accessible after installation. the benchtop is made of a heat resistant material. the installation complies with all the requirements of Australian and New Zealand Gas Installation
Standards (AS/NZS 5601.1.2010), including that the product has to be installed so that the surface temperature of any nearby combustible surface will not exceed 65
‘Clearance Dimensions’.
When you install the appliance
We do not recommend you flush mount or seal this appliance into the bench with silicone or glue. Doing so will make future servicing difficult. Fisher & Paykel will not be liable for any costs associated with removing or replacing a sealed-in appliance, nor for repairing any damage that may be incurred by doing this.
If installed with an approved flexible hose, the hose should not come in contact with the bottom of the appliance or any sharp edges. Flexible hose assemblies should be AS/NZS 1869 Class B or Class D certified.
Seal exposed bare edges of the cutout with an oil-based paint or moisture-proof polyurethane to prevent possible moisture creeping between the cooktop trim and the benchtop.
Take extreme care not to chip, crack, or break the top glass surfaces during installation. A heavy metal tool or part accidentally dropped on the glass could damage it.
If, after following the instructions given, correct performance cannot be achieved, please contact your nearest Fisher & Paykel Authorised Service Centre, Customer Care, or contact us through our
website listed at the end of this document.
O
C above ambient. See step 5
2
PARTS SUPPLIED
3
Dual Wok Pan support
(Models with a Dual Wok only)
Clamping brackets (4) and screws (4)
Pan support
(not supplied with Dual Wok only models)
LPG test point adaptor (1)
(LPG models only)
Mini wok Pan support (1)
(CG604D only)
NG regulator (1)
(NG models only)
Small pan support (1)
(some models only)
Installing multiple products
Note: if installing multiple products adjacent to each other within the same cutout, a separate joining strip kit is required for installation.
The kit is available from the nearest Fisher & Paykel Authorised Service Centre or our website listed at the end of this document.
Wok stand (1)
Fibre washer (1) Elbow
external thread (1)
1
/
2
“ BSP
3
GAS RATE SUMMARY-MODELS
4
SEMI-RAPID
AUX
CG302D CG451D
SEMI-RAPID
MINI WOK
CG604D
SEMI-RAPID
AUX
DUAL WOK
DUAL WOK
CG752D
SEMI-RAPID
DUAL WOK
SEMI-RAPID
CG603D
DUAL WOK
DUAL WOK
SEMI-RAPID
DUAL WOK
SEMI-RAPID
RAPID
CG905DCG903D
SEMI-RAPID
DUAL WOK
AUX
3
GAS RATE SUMMARY
All appliances are factory set for Natural gas or LPG and are not convertible. Check the appliance data label.
CG302D CG451D CG603D
BURNER
AUX SEMI-RAPID DUAL WOK SEMI-RAPID DUAL WOK
5
Jet size
GAS TYPE
NG (1.00 kPa)* 1.00 5.0 1.35 8.8
LPG (2.75
kPa)*
(mm)
0.64 5.0 0.80 8.1
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
Jet size
(mm)
1.43
1.43
0.70
0.80
0.80
0.50
Nominal
rating
(MJ/h)
21.0 1.30 8.4
19.5 0.76 7.5
Jet size
(mm)
CG604D, CG752, CG903 & CG905
GAS TYPE
NG (1.00 kPa)* 0.85 3.6 1.30 8.3 1.55 11.5 1.55 11.7
LPG (2.75
kPa)*
BURNER
AUX SEMI-RAPID RAPID MINI WOK DUAL WOK
Jet size
(mm)
0.55 3.6 0.76 7.5 0.94 11.5 0.94 11.7
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
Nominal
rating
(MJ/h)
Jet size
(mm)
1.30
1.30
0.70
0.76
0.76
0.50
Jet size
(mm)
1.26
1.26
0.70
0.73
0.73
0.50
Nominal
rating
(MJ/h)
Nominal
rating
(MJ/h)
16.6
16.8
18
18
*Nominal pressure with at least one large burner on High.