The Baumann 24003 3-way control valve (figure 1) is ideally suited for control of flow and temperature where mixing
or diverting service is required.
Scope of Manual
This instruction manual includes installation, maintenance, and parts information for the Baumann 24003 3-way
control valve.
Do not install, operate, or maintain Baumann 24003 3-way control valves without being fully trained and
qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid personal
injury or property damage, it is important to carefully read, understand, and follow all the contents of
this manual, including all safety cautions and warnings. If you have any questions about these
instructions, contact your Emerson sales office
before proceeding.
www.Fisher.com
24003 Valve
February 2021
Instruction Manual
D103357X012
WARNING
Always wear protective gloves, clothing and eyewear when performing any installation operations to avoid personal
injury.
Personal injury or property damage caused by sudden release of pressure or bursting of pressure retaining parts may result
if service conditions exceed those for which the product was intended. To avoid injury or damage, provide a relief valve for
over pressure protection as required by government or accepted industry codes and good engineering practices.
Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.
CAUTION
This valve is intended for a specific range of pressures, temperatures and other application specifications. Applying
different pressures and temperatures to the valve could result in parts damage, malfunction of the control valve or loss of
control of the process. Do not expose this product to service conditions or variables other than those for which the product
was intended. If you are not sure what these conditions are you should contact your Emerson sales office
complete specifications. Provide the product serial numbers (shown on the nameplate) and all other pertinent information.
for more
WARNING
If you move or work on an actuator installed on a valve with loading pressure applied, keep your hands and tools away
from the stem travel path to avoid personal injury. Be especially careful when removing the stem connector to release all
loading on the actuator stem whether it be from air pressure on the diaphragm or compression in the actuator springs.
Likewise take similar care when adjusting or removing any optional travel stop. Refer to the relevant actuator Maintenance
Instructions.
If hoisting the valve, take care to prevent people from being injured in case the hoist or rigging slips. Be sure to use
adequate sized hoists and chains or slings to handle the valve.
WARNING
Personal injury could result from packing leakage. Valve packing is tightened before shipment; however, the packing
might require some readjustment to meet specific service conditions.
2
Instruction Manual
D103357X012
24003 Valve
February 2021
Educational Services
For information on available courses for the Baumann 24003 valve, as well as a variety of other products, contact:
Avoid personal injury and property damage from sudden release of process pressure or bursting of parts. Before
performing any maintenance operations:
D Do not remove the actuator from the valve while the valve is still pressurized.
D Always wear protective gloves, clothing, and eyewear when performing any maintenance operations.
D Disconnect any operating lines providing air pressure, electric power, or a control signal to the actuator. Be sure the
actuator cannot suddenly open or close the valve.
D Use bypass valves or completely shut off the process to isolate the valve from process pressure. Relieve process pressure
on both sides of the valve. Drain the process media from both sides of the valve.
D Depending on the actuator construction, it will be necessary to manage the pneumatic actuator spring
pre-compression. It is essential to refer to the relevant actuator instructions in this manual to perform safe removal of
the actuator from the valve.
D Use lock‐out procedures to be sure the above measures stay in effect while you work on the equipment.
D The valve packing box may contain process fluids that are pressurized, even when the valve has been removed from the
pipeline. Process fluids may spray out under pressure when removing the packing hardware or packing rings, or when
loosening the packing box pipe plug.
D Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
Note
Whenever a gasket seal is disturbed by removing or shifting gasketed parts, install a new gasket during reassembly. This provides a
good gasket seal because the used gasket may not seal properly.
WARNING
Avoid personal injury or property damage by thoroughly cleaning the line of all dirt, welding chips, scale, oil or grease, and
other foreign material. Failure to do so could result in parts damage, malfunction of the control valve or loss of control of
the process.
Installation
1. Before installing the valve in the pipeline, thoroughly clean the line of all dirt, welding chips, scale, oil or grease, and
other foreign material.
3
24003 Valve
February 2021
2. Install the valve so the controlled fluid will flow through the valve body in the direction indicated for either mixing or
diverting service (see table 1).
3. A three-valve bypass must be used to permit removal of the control valve from the line without shutting down the
system.
4. In case of a heat-insulated installation, insulate the valve body only, not the bonnet.
Instruction Manual
D103357X012
WARNING
To avoid personal injury or property damage, do not attempt to do any work on a valve while the system is in operation.
The valve must be isolated 100% from the active system and the isolated line voided of pressure and/or hazardous fluids.
Air Piping
1. For an air-to-extend actuator (air-to-close Port L), connect the actuating air pressure line to the 1/4 NPT opening in
the upper diaphragm case. For an air-to-retract actuator (air-to-open Port L) connect the actuating air pressure line
to the 1/4 NPT in the lower diaphragm case.
2. Use 6.4 mm (1/4 inch) O.D. tubing or equivalent for all air lines. If air line exceeds 8 m (25 ft) in length, 9.5 mm (3/8
inch) tubing is preferred. Air lines must not leak. Air pressure not to exceed 2.5 bar (35 psig).
CAUTION
When assembling or disassembling the valve, do not turn the valve stem while the plug is touching the valve seat. This can
damage the valve's seating surface very quickly.
When adjusting the valve stem, do not grip the stem directly with pliers or a wrench. This will damage the surface of the
stem, and cause damage to the packing in the valve. Instead, counter-tighten the two locknuts (key 27) on the stem (key
5). This will allow you to turn the stem by turning the locknuts (key 27) with a wrench.
Disassembly
WARNING
When placing the valve in a vise, clamp the flat end faces of the valve. Do not try to clamp the rounded sides of the valve.
This will distort the shape of the casting, and damage the valve internals.
1. Mount the valve in a vise.
2. Remove the actuator, stem locknuts (key 27), travel indicator (key 58), and yoke drive nut (key 8). See the Baumann
3. Unscrew the bonnet (key 3) by turning in a counterclockwise direction from the valve body (key 1). Lift the bonnet
up and off the plug and stem assembly (key 4).
4. Unscrew the lower seat ring retainer (key 5) from the valve body (key 1) and remove the plug and stem assembly
(key 4) (see figure 2). Wipe the parts with a clean soft cloth and examine for signs of wear.
).
Lapping the Valve Seat
If valve seat leakage becomes excessive, it may be necessary to lap the valve seat.
4
Instruction Manual
D103357X012
Lapping is the process of mating the valve plug to the seat ring, with an abrasive to produce a close fit. When valve seat
leakage becomes excessive, lapping becomes necessary. The plug and seat ring seating surfaces should be free of
large scratches or dents and the contact surface of the seats should be as narrow as possible.
1. Use a good quality lapping compound with a mixture that contains 280 to 600 grit. Apply at several spots around
the plug seating surface.
2. Replace the plug and stem assembly (key 4) through the bottom of the valve body (key 1) and screw in the lower
seat ring retainer (key 5).
3. Place the bonnet (key 3) loosely into the valve body to serve as a guide during the lapping operation.
4. Rotate the plug and stem assembly (key 4), applying light pressure to the plug/seat mating surface.
5. Lap as little as possible. Excessive lapping will shoulder the seat ring, and will not improve the seating. Repeat for
the second seating surface.
6. Clean the valve seats and plug thoroughly when the lapping is complete.
24003 Valve
February 2021
Replacing Packing
Refer to figure 2 and the standard and optional packing constructions (figures 3, 4, and 5) to determine the packing
that has been preinstalled in your valve.
8) per the Baumann Pneumatic Actuators Instruction Manual (D103352X012
3. Unscrew the bonnet (key 3) by turning in a counterclockwise direction from the valve body (key 1). Lift the bonnet
up and off the plug and stem assembly (key 4). Push the old packing out from the underside of the bonnet (key 3).
4. Standard Spring Loaded PTFE V-Ring Packing (figures 2 and 3): Carefully insert each piece in exact order shown in
figure 3. Turn the packing follower (key 7) until it shoulders on the bonnet (key 3). This will compress the packing
spring (key 9) to enable constant stem sealing throughout packing life.
5. Molded Graphite Ribbon Packing (figure 4): Carefully insert each piece in exact order shown in figure 4. Hand
tighten the packing follower (key 7). Use a wrench to increase tightness by turning the nut an additional 60
degrees.
6. ENVIRO-SEAL Packing (figure 5): Carefully insert each piece in exact order as shown in figure 5. Tighten the packing
follower (key 7) until the Belleville springs are compressed. This will be signaled by a significant increase in
resistance. Back off the follower 1/8 to 1/4 turn. A gap of approximately 1/16 inch between the packing follower
and the bonnet will ensure packing is seated properly.
)
CAUTION
Overtightening the packing may prevent stem movement and valve operation and result in equipment damage or loss of
control of the process.
Reassembly
1. Place the plug and stem assembly (key 4) into the valve body (key 1) from the lower port and screw in the lower seat
ring retainer (key 5).
2. Place the bonnet (key 3) over the stem and tighten in place.
3. Insert the packing kit by following steps 4, 5, or 6 of Replacing Packing shown previously.
4. Place the actuator yoke over the stem and bonnet. While tilting the actuator back to allow access to the top of the
stem, place the yoke drive nut (key 8) over the stem.
5
24003 Valve
February 2021
Instruction Manual
D103357X012
5. Next, turn one locknut (key 27) onto the stem, turning it down as far as possible. Place the travel indicator (key 58)
over the stem and then turn the second locknut (key 27) down against the travel indicator (key 58). Counter turn
the locknuts to tighten securely.
See the Baumann Pneumatic Actuators Instruction Manual (D103352X012
) for bench range adjustment.
CAUTION
When assembling or disassembling the valve, do not turn the valve stem while the plug is in contact with either seat. This
can damage the seating surface very quickly.
Table 1. Application Port
ServiceInletOutlet
DivertingCU and L
MixingU and LC
1. C = common port, U = upper port, L = lower port
(1)
Parts Ordering
When corresponding with your Emerson sales office about this equipment, always mention the valve serial number.
When ordering replacement parts, also specify the key number, part name, and desired material using the following
parts tables.
WARNING
Use only genuine Fisher™ replacement parts. Components that are not supplied by Emerson should not, under any
circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the performance
of the valve, and could cause personal injury and property damage.
The ENVIRO-SEAL PTFE packing system is suitable for
100 ppm environmental applications on services up to
51.7 bar (750 psig) and process temperatures ranging
from -46 to 232_C (-50 to 450_F).
For non-environmental applications, this packing
system offers excellent performance at the same
temperature range up to the maximum valve working
pressure.
Temperature limits apply to packing arrangements
only. Complete valve assembly temperature limits may
differ. Refer to appropriate pressure/ temperature
ratings.
NOTE: ACTUATOR REMOVAL REQUIRES 115 mm (4.5 INCHES) VERTICAL CLEARANCE.
BAUMANN 32 ATO/FAIL
CLOSED ACTUATOR
WITH HANDWHEEL
94
(3.7)
31 (1.24)
BAUMANN 32 ACTUATOR
VALVE CONTROLLER
130 (5.1)
WITH ADJUSTABLE
OPEN/CLOSE DUAL
TRAVEL STOPS
(10.7)
MAX
BAUMANN 54 ATC / FAIL
OPEN ACTUATOR WITH
271
279 (411.0)
160 (46.3)
HANDWHEEL
BAUMANN 70 ACTUATOR w/
FIELDVUE DVC6010 DIGITAL
VALVE CONTROLLER
279 (411.0)
152 (46.0)
71 (2.8)
MAX
BAUMANN 54 ATO/FAIL
CLOSED ACTUATOR w/
HANDWHEEL
mm
(inch)
Table 6. Valve Dimensions and Weights, NPT Valve Bodies Only
VALVE SIZE
Bronze, NPTStainless Steel, NPT
DNNPSABC
151/24.8752.752.754.81252.752.750.568
2514.8752.752.755.02.752.750.568
401-1/25.753.81253.31256.1253.3753.1250.7515
5026.504.03.6256.503.753.6250.7520
VALVE BODY MATERIAL
1
ABC
TRAVELWEIGHT
1
Incheslbs
9
24003 Valve
February 2021
Instruction Manual
D103357X012
Table 7. Actuator Weights
ACTUATOR TYPE
324.510
5411.325
7015.434
WEIGHTS
kglb
Figure 7. Mixing and Diverting Applications
DIVERTING
VALVE
COOL
WATER
C
L
HEAT EXCHANGER
U
TEMPERED
WATER
Table 8. Application Port
ServiceInletOutlet
DivertingCU and L
MixingU and LC
1. C = Common port, U = Upper port, L = Lower port
HEATING WATER
MIXING
VALVE
U
C
(1)
RETURN
E1286
L
10
Instruction Manual
D103357X012
24003 Valve
February 2021
11
24003 Valve
February 2021
Instruction Manual
D103357X012
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance
of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Baumann, Fisher, FIELDVUE, and ENVIRO-SEAL are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson
Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are
the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
Emerson Automation Solutions
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Cernay 68700 France
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com
12
E 2009, 2021 Fisher Controls International LLC. All rights reserved.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.