Introduction
This installation guide provides instructions for installation, startup and adjustment. To receive a copy of the instruction manual, contact your local Sales Office or view a copy at www.fisher.com. For further information refer to: Type 112 Instruction Manual, D103237X012.
PED Categories
This product may be used as a safety accessory with pressure equipment in the following Pressure Equipment Directive categories. It may also be used outside of the Pressure Equipment Directive using sound engineering practice (SEP) per table below. For information on the current PED revision see Bulletin: D103053X012.
PRODUCT SIZE CATEGORIES FLUID TYPE
1/4 NPT SEP 1
Specifications
Maximum Inlet Pressure and Pressure Drops
Restrictor: 1500 psig / 103 bar
Flow Coefficients
Restrictor: See Table 1
Construction Materials
Body: CB7Cu-2 Stainless steel Groove Valve: 416 Stainless steel Retainer: 416 Stainless steel Pipe Plug: 316 Stainless steel O-ring: Fluorocarbon (FKM)
Proof Test Pressure
All Pressure Retaining Components have been proof tested per Directive.
(1)
Installation
WARNING
!
Only qualied personnel should install or service a regulator. Regulators should
be installed, operated and maintained
in accordance with international and
applicable codes and regulations and Emerson Process Management Regulator
Technologies Inc. instructions.
If the regulator vents uid or a leak develops in the system, it indicates that service is required. Failure to take the
regulator out of service immediately may
create a hazardous condition.
Table 1. Restrictor Flow Coefficients
SET ON START SET ON RUN
C
g
6 0.17 1 0.03 35
C
V
C
g
C
V
C
1
Personal injury, equipment damage or
leakage due to escaping uid or bursting
of pressure-containing parts may result
if this regulator is overpressured or is installed where service conditions could exceed the limits given in the Specications section, or where conditions exceed any ratings of the
adjacent piping or piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation or standard) to prevent service conditions from exceeding limits.
Additionally, physical damage to the
regulator could result in personal injury and property damage due to escaping
uid. To avoid such injury and damage, install the regulator in a safe location.
Clean out all pipelines before installation of the regulator and check to be sure the regulator has not been damaged or has collected foreign material during shipping. For NPT bodies, apply pipe compound to the external pipe threads.
Startup and Adjustment
The Type 112 restrictor controls the regulator’s proportional band (droop) and speed of response. The restrictor can be used to fine tune the regulator for maximum performance by decreasing the restrictor setting for tighter control (increased opening speed, decreased closing speed); or increasing the restrictor setting for maximum stability (decreased opening speed, increased closing speed). A lower setting also provides a narrower proportional band for better accuracy. The START position has the largest flow, is most stable, and easiest for startup, however, using the START position is not necessary. The “0” setting has the smallest (minimum) flow passage; at no point of rotation will the Type 112 restrictor be completely shut off. After initial adjustment, the restrictor does not need to be adjusted for maintenance or startup.
1. The pressure/temperature limits in this installation guide and any applicable standard or code limitation should not be exceeded.
Type 112
Taking Out of Service (Shutdown)
WARNING
!
To avoid personal injury resulting from sudden release of pressure, isolate
the restrictor from all pressure before
attempting disassembly.
Parts List
Key Description
14 Pipe Plug 21 Body 22 Groove Valve 23 Retainer 24* Groove Valve O-ring
*Recommended spare part
20B4393-D
APPLY LUBRICANT
14
22
23
21
24
Figure 1. Type 112 Restrictor Assembly
Webadmin.Regulators@emerson.com
Fisher.com
Emerson Automation Solutions
Americas McKinney, Texas 75070 USA T +1 800 558 5853
+1 972 548 3574
Europe Bologna 40013, Italy T +39 051 419 0611
For further information on the current PED revision see Bulletin: D103053X012 or scan the QR code.
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation
Asia Pacic
Singapore 128461, Singapore T +65 6777 8211
Middle East and Africa
Dubai, United Arab Emirates T +971 4 811 8100
D103056X014 © 2002, 2019 Emerson Process Management Regulator Technologies, Inc. All rights reserved. 01/19. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher™ is a mark owned by Fisher Controls International LLC, a business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the
designs or specications of our products at any time without notice.
Emerson Process Management Regulator Technologies, Inc does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser.