First Alert co614 User Manual

Page 1
5
USER’S MANUAL
120V PLUG-IN CARBON MONOXIDE ALARM WITH
BATTERY BACK-UP AND TEST/SILENCE
eliable Protection, Maximum
R
onvenience!
C
Just install the battery, plug
• the alarm into a regular outlet,
est, and it’s ready to go!
t Battery back-up keeps alarm
• working if electricity fails.
• Memory stores highest levels
f CO detected. Easy to
o display, easy to clear!
rinted in Mexico
P M08-0190-002
his user’s manual contains important information about your Carbon
T
onoxide (CO) Alarm’s operation. If you are installing this CO alarm for use
M by others, you must leave this manual—or a copy of it—with the end user.
P 01/08
P
IMPORTANT!
20V AC
1
0 Hz 0.09A
6
LISTED TO
L 2034
U
odel CO614
M
TABLE OF CONTENTS
duction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Intro
Basic Safety Information
ow Your CO Alarm Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
H
Understanding Your CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Using the Peak CO Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Where to Install CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where CO Alarms Should NOT Be Installed . . . . . . . . . . . . . . . . . . . . .3
How to Install Your CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If Your CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
If the Alarm Signal Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Using the Silence Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Testing and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Replacing the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Finding the Source of CO After an Alarm . . . . . . . . . . . . . . . . . . . . . . .5
Potential Sources of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . . . .5
How Can I Protect My Family? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Underwriters Laboratories Inc. UL2034 . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
General Limitations Of CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
ranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Limited W
ar
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
INTRODUCTION
BASIC SAFETY INFORMATION
Dangers, Warnings, and Cautions alert you to important operating
• nstructions or to potentially hazardous situations. Pay special
i attention to these items.
THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to detect
arbon monoxide from ANY source of combustion. It is NOT designed
c to detect smoke, fire, or any other gas.
This CO Alarm is approved for use in single-family residences.
~
It is NOT designed for marine or RV use.
• This CO Alarm will only indicate the presence of carbon monoxide gas
t the sensor. Carbon monoxide gas may be present in other areas.
a
The Silence Feature is for your convenience only and will not correct
a CO problem. Always check your home for a potential problem after
ny alarm. Failure to do so can result in injury or death.
a This CO Alarm should receive continuous 120VAC, 60 Hz, pure sine
wave electrical power. (The battery is meant for emergency back-up only). Do not use in an extension cord or outlet controlled by a dim-
er or switch. In order for the emergency battery back-up to work,
m a working (fresh) battery must be properly installed.
• NEVER ignore your Carbon Monoxide Alarm if it alarms. Refer to
If Your CO Alarm Sounds” for more information. Failure to do so can
esult in injury or death.
r Test the CO Alarm once a week. If the CO Alarm ever fails to test
correctly, have it replaced immediately! If the CO Alarm is not working properly, it cannot alert you to a problem.
• This product is intended for use in ordinary indoor locations of family
living units. It is not designed to measure CO levels in compliance with Occupational Safety and Health Administration (OSHA) commer­cial or industrial standards. Individuals with medical conditions that may make them more sensitive to carbon monoxide may consider using warn carbon monoxide concentrations under 30 ppm. For additional infor­mation on carbon monoxide and your medical condition contact your physician.
ing devices which provide audible and visual signals for
HOW YOUR CO ALARM WORKS
GENERAL INFORMATION
Leave your CO Alarm plugged in year-round. CO problems can occur any time during the year, and this Alarm can only alert you if it is plugged in and receiving power.
This CO Alarm is intended for use in a standard, unswitched 120V AC wall outlet. It is not intended for use in extension cords, power strips, or outlets controlled by a switch or dimmer. These may not provide continuous power to the unit. When fully powered, the unit samples the air and takes a new reading about every second. A microchip inside the unit stores each reading, and remembers the levels of CO it has been exposed to over time. The Alarm sounds when it has been exposed to a “critical” level of CO (measured in parts per million or “ppm”) within a specified time (measured in minutes). This CO Alarm features a permanently installed sensor, an indicator light, and an 85 dB alarm hor horn.
MALFUNCTION WARNING
This unit performs self-diagnostic tests approximately every second. If the Alarm malfunctions, replace it immediately.
n. It also has a Silence Feature to temporarily quiet the alarm
© 2008 BRK Brands, Inc., a Jar 3901 Liberty Street Road, Aurora, IL 60504-8122 All rights reserved. Consumer Affairs: (800) 323-9005 • www.firstalert.com
den Corporation company (NYSE: JAH)
THE COVER OF YOUR CO ALARM
1 Test/Silence/Scroll Button:
Pr (Test, Memory, Clear Memory); Press and hold to activate mode,
or to silence the alarm. 2 POWER/ALARM Light (Red) 3 Digital Display
Air V
4 5 Alarm Horn: 85 dB audible
alarm for test, alarm, and unit
malfunction warning
elease to select mode
ess and r
ents
1
Page 2
GARAGE
S
UGGESTED AREAS FOR INSTALLING ADDITIONAL CO ALARMS
B
EDROOM
BEDROOM
HALL
LIVING ROOM
KITCHEN
BASEMENT
BEDROOM
R
EQUIRED TO MEET NFPA RECOMMENDATIONS
UNDERSTANDING YOUR CO ALARM
ASIC POWER CONDITIONS
B
larm operating
A on AC power
larm operating
A on emergency battery back-up
What you see and hear during installation
HEN YOU FIRST INSTALL THE
W BATTERY:
Chirps briefly
HORN: DISPLAY: Flashes “888” briefly;
witches to “bat” after a minute
s
OWER/ALARM Light: Flashes
P
nce a minute
o
HEN YOU FIRST PLUG-IN
W THE CO ALARM:
HORN:
Silent
ISPLAY: Dash appears by
D
“READY”
POWER/ALARM LIGHT:
hines continuously
S
What you see and hear under different conditions:
DURING A POWER FA
IN BATTERY BACK-UP):
(
Silent
HORN: DISPLAY: Displays the word
“bat” continuously POWER/ALARM LIGHT: Flashes
once a minute.
WHEN THE ELECTRICITY COMES BACK ON:
Silent
HORN: DISPLAY: Dash appears by
“READY” POWER/ALARM LIGHT: Shines
continuously.
ILURE
What you see and hear if CO is detected:
PRE-ALARM LEVELS:
Silent
HORN: DISPLAY: Shows CO levels
detected in ppm
POWER/ALARM LIGHT
On continuously
ALARM LEVELS OF CO ARE DETECTED:
Sounds loudly - 4 beeps,
HORN:
pause, 4 beeps, pause. This sequence repeats for as long as the unit is in alarm*
DISPLAY: Shows CO levels detected in ppm
POWER/ALARM LIGHT:
Flashes rapidly *Note: If unit goes into alarm
under battery back-up power the regular 4 beeps-brief pause cycle will r After four minutes, the pause will increase to 1 minute.
epeat for four minutes.
:
,
ow / missing
L battery warning
NDER NORMAL CONDITIONS
U (AC POWER):
Silent
HORN: DISPLAY: Dash remains lit at
READY”
OWER/ALARM LIGHT: Shines
P
ontinuously
c
HEN YOU TEST THE CO
W ALARM:
HORN:
Sounds loudly - 4
beeps, pause, 4 beeps, pause
DISPLAY:Flashes “30, 70, 150,
00” briefly
4
OWER/ALARM LIGHT:
P
lashes rapidly
F
TERY BECOMES LOW
IF BAT
R IS MISSING:
O
HORN:
Chirps once a minute*
DISPLAY:
on and off POWER/ALARM LIGHT: Flashes
once a minute
IF THE CO ALARM IS NOT OPERATING PROPERLY:
HORN:
every minute
The word “bat” flashes
Three rapid chirps
DISPLAY: Displays “Err” POWER/ALARM LIGHT: Flashes
three times in sync with the horn.
IF YOU SILENCE THE ALARM:
Silent for about
HORN:
4 minutes* DISPLAY: Shows CO levels
detected in ppm
POWER/ALARM LIGHT:
Flashes rapidly *Note: After 4 minutes, if CO
levels drop below alarm levels, the unit will remain silent and return to normal operation.
esence still indicates a
If CO pr potentially dangerous situation, the horn will sound again.
IF THE CO LEVELS RETURN TO NORMAL:
Silent
HORN: DISPLAY:Dash lit by “READY” POWER/ALARM LIGHT:
Shines continuously
Err” Alarm is
“ not operating properly
U
SING THE PEAK CO MEMORY
he CO Memory Feature lets you check the highest level of CO recorded
T
uring an alarm.
d
o check CO Memory:
T
. Press and release the Test/Silence/Scroll button until the dash scrolls
1
o “MEMORY”.
t
. Press and hold Test/Silence/Scroll button to display Memory CO level.
2
To clear CO Memory:
. Press and release the Test/Silence/Scroll button until the dash scrolls to
1
“CLEAR MEMORY.”
. Press and hold the Test/Silence/Scroll button until the display shows “CLr.”
2
OTE: The highest CO level will be saved, even after a power interruption,
N
ntil you clear it. DO NOT clear the CO Memory reading if you plan to call
u someone to investigate a CO problem! Clear the CO Memory reading only
fter the investigator has checked your home.
a
INSTALLATION
WHERE TO INSTALL CO ALARMS
The National Fire Protection Association (NFPA) recommends that a CO Alarm
hould be centrally located outside of each separate sleeping area in the
s
mmediate vicinity of the bedrooms. For added protection, install additional
i CO Alarms in each separate bedroom, and on every level of your home.
If your bedroom hallway is longer than 40 feet (12 meters), install a CO Alarm at BOTH ends of the hallway
In a Single-level Home:
• Install at least one CO Alarm near or within each separate sleeping area.
• For added protection, install an additional CO Alarm at least 20 feet (6 meters) away from the furnace or fuel burning heat source.
In a Multi-level Home:
Install at least one CO Alarm near or within each separate sleeping area.
• For added protection, install at least one CO Alarm on each level of the
• home. If you have a basement, install that CO Alarm at the top of the basement stairs.
• For added protection, install an additional CO Alarm at least 20 feet (6 meters) away from the furnace or fuel burning heat source.
This unit should receive continuous electrical power. (The battery is meant for emergency back-up only). Choose an outlet where it can’t be accidentally unplugged or switched of away from the unit. Teach them not to play with it or unplug it. Explain what the alar
ms mean.
.
f by childr
en. Keep small children
2
Page 3
W
2
1
+
HERE CO ALARMS SHOULD NOT BE INSTALLED
O NOT locate this CO Alarm:
D
• In garages, kitchens, furnace rooms, or in any extremely dusty, dirty r greasy areas.
o Closer than 15 feet (4.6 meters) from a furnace or other fuel burning heat
• ource, or fuel burning appliances like a water heater.
s Within 5 feet (1.5 meters) of any cooking appliance.
In extremely humid areas. This Alarm should be at least 10 feet (3 meters)
rom a bath or shower, sauna, humidifier, vaporizer, dishwasher, laundry
f room, utility room or other source of high humidity.
• In areas where temperature is colder than 40˚ F (4˚ C) or hotter than 100˚ F
(38˚ C). These areas include non-airconditioned crawl spaces, unfinished
ttics, uninsulated or poorly insulated ceilings, porches, and garages.
a In turbulent air, like near ceiling fans, heat vents, air conditioners,
resh air returns, or open windows. Blowing air may prevent CO from
f reaching the sensors.
• In direct sunlight.
In outlets covered by curtains or other obstruction.
This CO Alarm is designed for use inside a single-family home or
apartment. It is not meant to be used in common lobbies, hallways, or basements of multi-family buildings unless working CO Alarms are
lso installed in each family living unit. CO Alarms in common areas
a may not be heard from inside individual family living units.
This CO Alarm alone is not a suitable substitute for complete
detection systems in places which house many people, like hotels
r dormitories, unless a CO Alarm is also placed in each unit.
o DO NOT use this CO Alarm in warehouses, industrial or commercial
buildings, special-purpose non-residential buildings, RVs, boats, or airplanes. This CO Alarm is specifically designed for residential
se, and may not pro
u applications.
vide adequate protection in non-residential
HOW TO INSTALL YOUR CO ALARM
IMPORTANT! Read all instructions before using this product.
Quick reference:
• Install the 9V battery to activate the battery back-up.
• Plug the Alarm into a standard 120V unswitched outlet.
• Test the CO Alarm.
TO ACTIVATE OR CHANGE BATTERY BACK-UP
1. Open the battery compartment on the back of the Alarm.
2. Insert the new battery, making sure it snaps completely into the battery terminals and cannot be shaken loose.
3. Close the battery compartment, then test the battery back-up by pressing the Test/Silence/Scroll button.
4. Plug the CO Alarm into the outlet.
The battery back-up is designed to provide emergency power to the CO Alarm for 7 days. Actual back-up time depends on the strength (freshness) of the battery. The battery back-up will not work unless a good battery is pr
operly installed.
P
LUG THE ALARM INTO AN OUTLET
This CO Alarm should receive continuous electrical power. The battery is
eant for emergency back-up only. Do not plug this Alarm into an outlet
m
ontrolled by a dimmer or switch.
c
. Plug the unit into a standard UNSWITCHED 120V AC outlet. The unit
1
should be located where it can wake you if it alarms at night.
. Make sure the POWER/ALARM light shines continuously when you
2
lug it in.
p
3. Test by pressing the Test/Silence/Scroll button firmly until the unit sounds: beeps, pause, 4 beeps. During testing, the POWER/ALARM light will
4
lash and “30, 70, 150, 400” will scroll on the Display. This is normal.
f
PREPARE YOUR ALARM LABELS
ind the pair of self-adhesive labels included with this CO Alarm.
F
On each label write in the phone number of your emergency responder
like 911) and a qualified appliance technician.
( Place one label near the CO Alarm, and the other label in the “fresh air”
location you plan to go if the alarm sounds.
NOTE: A qualified appliance technician is defined as “a person, firm,
orporation, or company that either in person or through a representative,
c
s engaged in and responsible for the installation, testing, servicing, or
i replacement of heating, ventilation, air conditioning (HVAC) equipment,
ombustion appliances and equipment, and/or gas fireplaces or other
c
ecorative combustion equipment.”
d
IF YOUR CO ALARM SOUNDS
ctuation of your CO Alarm
A (CO) which can kill you. When your CO Alarm sounds, you must not
it!
ignore
IF THE ALARM SIGNAL SOUNDS:
perate the Test/Silence button.
1. O
2. Call your emergency services, fire department or 911. Write down the
number of your local emergency service here:
__________________________________________________________________
3. Immediately move to fresh air—outdoors or by an open door or window.
Do a head count to check that all persons are accounted for. Do not re­enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your CO Alarm remains in its normal condition.
4. After following steps 1-3, if your CO Alarm reactivates within a 24-hour
period, repeat steps 1-3 and call a qualified appliance technician to inves­tigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this equipment. If problems are identified during this inspection have the equipment serviced immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence. Write down the number of a qualified appliance technician here:
_________________________________________________________________
ms have various limitations. See "General Limitations of CO Alar
Alar for details.
indicates the presence of carbon monoxide
“ALARM-MOVE TO FRESH AIR” If you hear the alarm horn and the red light is
flashing, move everyone to a sour DO NOT unplug the CO Alarm!
ce of fresh air.
Continued...
ms"
3
Page 4
U
SING THE SILENCE FEATURES
he Silence Feature is intended to temporarily silence your CO Alarm’s horn
T
hile you correct the problem—it will not correct a CO problem. While the
w
larm is silenced, it will continue to monitor the air for CO.
a To Activate the Silence Feature: press and hold the Test/Silence/Scroll
utton until the horn is silent.
b
nce you activate the Silence Feature: the Silence cycle will last
O
pproximately 4 minutes.
a
If CO levels drop below alarm levels after 4 minutes, the unit will return to
• normal operation and remain silent.
• If CO levels do not drop below alarm levels, the unit will alarm again.
he Silence Feature is for your convenience only and will not correct a
T CO problem. Always check your home for a potential problem after any
larm. Failure to do so can result in injury or death.
a
NEVER disconnect your CO Alarm to silence the horn. Use the Silence
eature. Unplugging the CO Alarm and removing the batteries removes
F
our protection!
y
SILENCING THE LOW BATTERY WARNING
his silence feature can temporarily quiet the low battery warning “chirp” for
T up to 8 hours without having to remove the battery. You can silence the low
attery warning “chirp” by pressing the Test/Silence button on the alarm cover.
b
nce the low battery warning “chirp” silence feature is activated, the unit
O
ontinues to flash the red light once a minute for 8 hours; the word “bat”
c will flash on and off on the display. After 8 hours, the low battery “chirp”
ill resume.
w
perate without battery power!
o
o deactivate this feature:
T
go into Test Mode and the low battery warning will resume (LED flashes and
nit sounds “chirp” once a minute.)
u
If you cannot silence the low battery immediately.
eplace the battery as soon as possible, this unit will not
R
ress the Test/Silence button again. The unit will
P
warning, re
place your battery
TESTING AND MAINTENANCE
WEEKLY TESTING
You can test this CO Alarm by pressing the Test/Silence/Scroll button on the Alarm cover until alarm sounds.
During testing, you will hear a loud alarm sequence – 4 beeps, pause, 4 beeps, pause.
• If the Alarm ever fails to test properly, replace it immediately. Products under warranty may be returned to the manufacturer for replacement. See “Limited Warranty” at the end of this manual.
• DO NOT stand close to the Alarm when the horn is sounding. Exposure at close range may be harmful to your hearing. When testing, step away when horn starts sounding.
• NEVER use vehicle exhaust! Exhaust may cause permanent damage and voids your warranty.
REGULAR MAINTENANCE
To keep the CO Alarm working properly:
• Test it every week as described in “Weekly Testing.”
acuum the CO Alarm cover at least once a month, using the soft brush
V
• attachment. Never use water, cleaners, or solvents, since they may dam­age the unit. T
• Replace the battery immediately when you see/hear the “Low Battery W
The Low (or Missing) Battery Warning:
n will “chirp” once a minute and the wor
The hor “bat” will flash on and off on the display.
est the Alarm again after vacuuming.
arning”.
d
R
EPLACING THE BATTERY
hoosing a Replacement Battery:
C
his unit requires one standard 9V alkaline battery. The following alkaline
T
atteries are acceptable as replacements: Duracell #MN1604 or MX1604;
b Eveready “Energizer” 522. You can also use an Ultralife 9 volt lithium battery
U9VL for longer service life between battery changes. These replacement
#
atteries are commonly available at local retail stores.
b
Use only the alkaline or lithium replacement batteries listed. The unit may not
perate properly with other batteries. Never use rechargeable batteries since
o
hey may not provide a constant charge.
t
O NOT spray cleaning chemicals or insect sprays directly on or near
D the CO Alarm. DO NOT paint over the CO Alarm. Doing so may cause
ermanent damage.
p
ousehold cleaners, aerosol chemicals and other contaminants can affect
H the sensor. When using any of these materials near the CO Alarm, make sure
he room is well ventilated.
t
f your home is being fumigated, unplug the unit temporarily and put it where
I it will not be exposed to chemicals or fumes. When fumigation is complete
nd all traces of fumes clear, plug the unit back in and retest it.
a
WHAT YOU NEED TO KNOW ABOUT CO
T IS CO?
WHA
CO is an invisible, odorless, tasteless gas pr burn completely, or are exposed to heat (usually fire). Electrical appliances
ypically do not produce CO.
t These fuels include: Wo
kerosene, and propane. Common appliances are often sources of CO. If they are not properly main-
ained, are improperly ventilated, or malfunction, CO levels can rise quickly.
t
O is a real danger now that homes are more energy efficient. “Air-tight”
C homes with added insulation, sealed windows, and other weatherproofing can “trap” CO inside.
od, coal, charcoal, oil, natural gas, gasoline,
SYMPTOMS OF CO POISONING
These symptoms are related to CO POISONING and should be discussed with ALL household members.
Mild Exposure:
Slight headache, nausea, vomiting, fatigue (“flu-like” symptoms).
Medium Exposure:
Throbbing headache, drowsiness, confusion, fast heart rate.
Extreme Exposure:
Convulsions, unconsciousness, heart and lung failure. Exposure to carbon monoxide can cause brain damage, death.
This CO Alarm measures exposure to CO over time. It alarms if CO levels are extremely high in a short period of time, or if CO levels reach a certain minimum over a long period of time. The CO Alarm generally sounds an alarm before the onset of symptoms in average, healthy adults. Why is this important? Because you need to be warned of a potential CO problem while you can still
eact in time. In many reported cases of CO exposure, victims may be awar
r that they are not feeling well, but become disoriented and can no longer react well enough to exit the building or get help. Also, young children and pets may be the first affected. The average healthy adult might not feel any symptoms when the CO Alarm sounds. However, people with cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or elderly people can be more quickly and severely affected by CO. If you experience even mild symptoms of CO poisoning, consult your doctor immediately!
oduced when fossil fuels do not
e
4
Page 5
F
INDING THE SOURCE OF CO AFTER AN ALARM
arbon monoxide is an odorless, invisible gas, which often makes it difficult
C
o locate the source of CO after an alarm. These are a few of the factors that
t
an make it difficult to locate sources of CO:
c
House well ventilated before the investigator arrives.
• Problem caused by “backdrafting.”
• Transient CO problem caused by special circumstances.
ecause CO may dissipate by the time an investigator arrives, it may be
B difficult to locate the source of CO.
o pay for any carbon monoxide investigation or service call.
t
BRK Brands, Inc. shall not be obligated
POTENTIAL SOURCES OF CO IN THE HOME
ning appliances like:
Fuel-bur
as kitchen range or cooktop, gas clothes dryer.
g
icient venting:
Damaged or insuf
vent pipe, leaking chimney pipe or flue, or cracked heat exchanger, blocked
r clogged chimney opening.
o Improper use of appliance/device: operating a barbecue grill or vehicle in
an enclosed area (like a garage or screened porch). Transient CO Problems:
be caused by outdoor conditions and other special circumstances.
The following conditions can re
1. Excessive spillage or reverse venting of fuel appliances caused by outdoor conditions such as:
• Wind direction and/or velocity, including high, gusty winds. Heavy air in
the vent pipes (cold/humid air with extended periods between cycles).
• Negative pressure differential resulting from the use of exhaust fans.
• Several appliances running at the same time competing for limited
fresh air.
• Vent pipe connections vibrating loose from clothes dryers, furnaces, or
water heaters.
• Obstructions in or unconventional vent pipe designs which can amplify
the above situations.
2. Extended operation of unvented fuel burning devices (range, oven, fireplace).
3. Temperature inversions, which can trap exhaust close to the ground.
4. Car idling in an open or closed attached garage, or near a home.
These conditions are dangerous because they can trap exhaust in your home. Since these conditions can come and go, they are also hard to recreate during a CO investigation.
f
portable heater
corr
transient” or on-again-off-again CO problems can
sult in transient CO situations:
, gas or wood burning fireplace,
ded or disconnected water heater
o
UNDERWRITERS LABORATORIES INC. UL2034
WHAT LEVELS OF CO CAUSE AN ALARM?
nderwriters Laboratories Inc. Standard UL2034 requires residential CO
U Alarms to sound when exposed to levels of CO and exposure times as described below. They are measured in parts per million (ppm) of CO over
ime (in minutes).
t
L2034 Required Alarm Points*:
U
• If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN and 15 MINUTES
4
• If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN
0 and 50 MINUTES.
1 If the alarm is exposed to 70 ppm of CO, IT MUST ALARM BETWEEN
0 and 240 MINUTES.
6
* Approximately 10% COHb exposure at levels of 10% to 95% Relative Humidity (RH).
The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days.
O Alarms are designed to alarm before there is an immediate life threat.
C Since you cannot see or smell CO, never assume it’s not present.
• An exposure to 100 ppm of CO for 20 minutes may not affect average,
ealthy adults, but after 4 hours the same level may cause headaches.
h An exposure to 400 ppm of CO may cause headaches in average,
ealthy adults after 35 minutes, but can cause death after 2 hours.
h
Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon
onoxide alarms UL2034.
m According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon
onoxide alarms covered by these requirements are intended to respond to
m the presence of carbon monoxide from sources such as, but not limited to, exhaust fro
ppliances, and fireplaces. CO Alarms are intended to alarm at carbon
a monoxide levels below those that could cause a loss of ability to re dangers of Carbon Monoxide exposure
he Alarm, and is designed to alarm before CO levels become life threatening.
t This allows you precious time to leave the house and correct the problem. This is only possible if Alarms are located, installed, and maintained as described in this manual.
Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically. UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts per million.
Audible Alarm: 85 dB minimum at 10 feet (3 meters).
m internal-combustion engines, abnormal operation of fuel-fire
.” This CO Alarm monitors the air at
d
act to the
HOW CAN I PROTECT MY FAMILY?
A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before Carbon Monoxide levels become threatening for average, healthy adults.
A CO Alarm is not a substitute for proper maintenance of home appliances.
To help prevent CO problems and reduce the risk of CO poisoning:
• Clean chimneys and flues yearly. Keep them free of debris, leaves, and nests for pr corrosion, cracks, or separations. These conditions can prevent proper air movement and cause backdrafting. Never “cap” or cover a chimney in any way that would block air flow.
est and maintain all fuel-bur
T
• oil companies and HVAC companies offer appliance inspections for a nominal fee.
• Make regular visual inspections of all fuel-burning appliances. Check appliances for excessive rust and scaling. Also check the flame on the bur fuel is not being burned completely and CO may be present. Keep the blower door on the furnace closed. Use vents or fans when they are available on all fuel-burning appliances. Make sure appliances are vented to the outside. Do not grill or barbecue indoors, or in garages or on screen por
Check for exhaust backflow fr
• on an operating furnace for a backdraft. Look for cracks on furnace heat exchangers.
Check the house or garage on the other side of shared wall.
• Keep windows and doors open slightly. If you suspect that CO is escaping into your home, open a window or a door. Opening windows and doors can significantly decrease CO levels.
In addition, familiarize yourself with all enclosed materials. Read this manual in its entir CO Alarm sounds.
oper air flow
ner and pilot lights. The flame should be blue. A yellow flame means
ches.
. Also, have a professional check for rust and
ning equipment annually
ces. Check the draft hood
e you understand what to do if your
, and make sur
ety
om CO sour
. Many local gas or
5
Page 6
FREQUENTLY ASKED QUESTIONS
hy doesn’t the Alarm respond when I test it and the POWER/ALARM
W
ight is OFF?
l
The CO Alarm is not receiving power. It may not be plugged in all the way
nd the battery may be missing, low, or dead. Gently push the unit all the
a
ay into the outlet, and make sure the outlet is not controlled by a dimmer
w or switch. Check the battery.
Why does the word “bat” keep flashing on the display?
(You will also hear a “chirp” once a minute.) The battery is weak or missing.
nstall a new battery immediately.
I
hy is the word “bat” continuously displayed?
W
he unit is operating on battery back-up.
T
hy does the Alarm sound three rapid “chirps” every minute
W (MALFUNCTION SIGNAL)?
Make sure the battery is installed correctly. If the display reads “Err,”
eplace the CO Alarm immediately. Units under warranty can be returned
r
o the manufacturer for replacement. See Warranty for details.
t
hy does the alarm sound again about 4 minutes after I used the
W Silence Feature?
CO levels still indicate a potentially dangerous situation. Refer to “If Your
O Alarm Sounds” for details on how to respond to an alarm. If anyone
C is feeling ill, EVACUATE your home immediately.
Why does the CO Alarm sound frequently, but no high levels of CO are found in an investigation?
The CO Alarm may be improperly located. Try relocating your alarm.
Refer to “Where
( home rechecked for potential CO problems. You may be experiencing an intermittent CO problem.
to Install CO Alarms.”) If frequent alarms continue, have
GENERAL LIMITATIONS OF CO ALARMS
This CO Alarm is intended for residential use. It is not intended for use in
ndustrial applications where Occupational Safety and Health Administration
i (OSHA) requirements for carbon monoxide detectors must be met.
O alarms may not waken all individuals.If children or others do not readily
C
aken to the sound of the CO alarm, or if there are infants or family members
w with mobility limitations, make sure that someone is assigned to assist them in the event of an emergency.
CO Alarms will not work without power. This CO Alarm requires a continu­ous supply of AC power. Plug into an unswitched 120V AC outlet only. The battery back-up is for emergency use only!
CO Alarms for Solar or Wind Energy users and battery backup power systems: AC powered CO Alarms should only be operated with true or pure
sine wave inverters. Operating this CO Alarm with most battery-powered UPS (uninterruptible power supply) products or square wave or “quasi sine wave”
will damage the Alarm. If you are not sure about your inverter or
inverters UPS type, please consult with the manufacturer to verify.
This CO Alarm will not sense carbon monoxide that does not reach the sensor. This CO Alarm will only sense CO at the sensor. CO may be present
in other areas. Doors or other obstructions may affect the rate at which CO reaches the CO Alarm. For this reason, if bedroom doors are usually closed at night, we recommend you install a CO Alarm in each bedroom and in the hallway between them.
CO Alarms may not sense CO on another level of the home. For example, a CO Alarm on the second level, near the bedrooms, may not sense CO in the basement. For this reason, one CO Alarm may not give adequate warning. Complete coverage is recommended. Place CO Alarms on each level of the home.
ms may not be heard.
CO Alar
current UL standards of 85 dB at 10 feet (3 meters). However, if the CO Alarm is installed outside the bedroom, it may not wake up a sound sleeper or one
ecently used drugs or has been drinking alcoholic beverages. This is
who has r especially true if the door is closed or only partly open. Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors. Noise from traffic, stereo, radio, television, air conditioner, or other appliances may also pr This CO Alarm is not intended for people who are hearing impaired.
e not a substitute for a smoke alar
ms ar
CO Alar
source of carbon monoxide, this CO Alarm does not sense smoke or fire. This CO Alarm senses CO that may be escaping unnoticed fr furnaces, appliances, or other sources. Early warning of fire requires the installation of smoke alarms.
CO Alarms are not a substitute for life insurance. Though these CO Alarms warn against increasing CO levels, BRK Brands, Inc. does not warrant or imply in any way that they will pr and renters must still insure their lives.
ms have a limited life.
CO Alar
have passed many stringent tests and are designed to be as reliable as possible, any of these parts could fail at any time. Therefore, you must test your CO Alarm weekly.
CO Alarms are not foolproof. Like all other electronic devices, CO Alarms have limitations. They can only detect CO that reaches their sensors. They may not give early war remote part of the home, away from the CO Alarm.
6 Year End of Life Timer. Every 24 hours of operation a counter stored in memory is updated. When the count equals 6 years of true operation, meaning actually power at the time of the 45 second Power-LED flash.
ed-up, a malfunction chirp (triple chirp) will sound once a minute
The alarm hor
event alert persons from hearing the alarm horn.
otect lives fr
Although the CO Alarm and all of its parts
ning to rising CO levels if the CO is coming fr
n loudness meets or exceeds
m.
Although fir
om CO poisoning. Homeowners
e is a
om malfunctioning
om a
LIMITED WARRANTY
RK Brands, Inc. ("BRK") the maker of First Alert
B that for a period of 5 years from the date of purchase, this product will be free
rom defects in material and workmanship. BRK, at its option, will repair or
f
eplace this product or any component of the product found to be defective
r during the warranty period. Replacement will be made with a new or remanu-
actured product or component. If the product is no longer available, replace-
f
ent may be made with a similar product of equal or greater value This is
m your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of initial
etail purchase and is not transferable. Keep the original sales receipt. Proof
r
f purchase is required to obtain warranty performance. BRK dealers, service
o centers, or retail stores selling BRK products do not have the right to alter,
odify or any way change the terms and conditions of this warranty.
m
his warranty does not cover normal wear of parts or damage resulting from
T
ny of the following: negligent use or misuse of the product, use on improper
a voltage or current, use contrary to the operating instructions, disassembly,
epair or alteration by anyone other than BRK or an authorized service center.
r
urther, the warranty does not cover acts of God, such as fire, flood, hurricanes
F and tornadoes or any batteries that are included with this unit.
BRK shall not be liable for any incidental or consequential damages caused by
he breach of any express or implied warranty. Except to the extent prohibited
t
y applicable law, any implied warranty of merchantability or fitness for a
b particular purpose is limited in duration to the duration of the above warranty.
ome states, provinces, or jurisdictions do not allow the exclusion or limitation
S
f incidental or consequential damages or limitations on how long an implied
o warranty lasts, so the above limitations or exclusion may not apply to you.
his warranty gives you specific legal rights, and you may also have other
T
ights that vary from state to state, or province to province.
r
ow to Obtain Warranty Service:
H Service: If service is required, do not return the product to your retailer.
n order to obtain warranty service, contact the Consumer Affairs Division at
I 1-800-323-9005, 7:30 AM to 5:00 PM, Central Standar Friday. To assist in serving you, please have the model number and date of purchase available when calling. BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906
Battery:BRK Brands, Inc. make no warranty,
oral, including that of merchantability or fitness for any particular purpose
ith respect to battery.
w
For your records, please record:
Date Purchased: _____________ Where Purchased: __________________
Date Installed: ____________/____________Month/Year
Replacement date is five years after installation: _________/_______
NOTE: End of Life Signal — Once the unit reaches the end of its lifecycle, the MALFUNCTION SIGNAL will sound once a minute to indicate the need to immediately replace the Alarm.