Digital Multimeter
OPERATOR'S
MANUAL
Model LT17AW
01
Quick Start
Receive a Wireless Reading
1. Select RECV on main dial.
2. Hold SYNC for one second.
3. Set partner device to transmitting switch
position.
4. Hold SYNC on partner device for one second.
When connection is made and icons
will display on the top of LT17AW screen.
5. Enjoy the wireless goodness!
Certications
IEC/EN61010-1
EMC EN61326-1
FCC
C-Tick (N22675)
WEEE
RoHS compliant
CATIII: Is for measurements performed in the
building installation.
02
Description
As a proud owner of the rst wireless digital
multimeter, LT17AW, you are well on your way to
eliminating tangled wires. LT17AW will give you
the power to receive measurements wirelessly
from anywhere on the jobsite. For instance, you
can transmit indoor wet bulb measurements
over-the-air while you work at the condenser.
Your LT17AW can receive measurements
wirelessly from any Fieldpiece accessory head
connected to a Fieldpiece wireless transmitter
like ET2W or EH4W.
In addition, your LT17AW can also transmit
wirelessly any measurement range on the dial
to any Fieldpiece wireless receiver, like EH4W,
HG3, or another LT17AW.
Your LT17AW easily syncs with compatible
wireless Fieldpiece transmitters and receivers.
LT17AW has a wide wireless range to cover the
whole jobsite.
Your LT17AW remembers the last meter it was
synced with, so there is no need to constantly
resync the same pairs. Note: this feature is
available when synched to single-link receivers
such as the LT17AW, ET2W, and EH4W.
03
Controls
500
50
5000m
500m
RECV
500µ
50m
200m
2
K
200
20
M
20
200
Rotate dial to the function you want to use.
Hold to connect to other Fieldpiece
SYN
wireless products.
Press to activate MAX or MIN. Hold to
MAX/MIN
return to normal mode.
OLD
Press to freeze reading on display.
Press to toggle backlight on and o.
04
600600
500
50
5000m
500m
200m
500
750
500
K
2
200
K
1400
500µ
50m
Display
Battery Life (replace 9V if blinking)
Auto Power O Enabled
Wireless Icon
Singal Strength Bars
HOLD (freezes current reading)
MAX (displays maximum reading)
MIN (displays minimum reading)
Continuity Test
Kilo Unit (103, one thousand)
Mega Unit (106, one million)
MAXMIN HOLD
k M
05
Specications
Wireless range: Up to 75 feet (23m) line of sight
Minimum Wireless Distance: Up to 1 foot (30cm)
Wireless Frequency: 910MHz to 920MHz (US), 868.1MHz to
868.5MHz (European)
Display: 5000 count liquid crystal display with backlight
Overrange: (OL) or (-OL) is displayed Zero: Automatic
Measurement rate: 2.5 times per second, nominal
Operating environment: 32°F to 122°F (0°C to 50°C) at <70% RH
Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH
(with battery removed)
Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH
Temperature coecient: 0.1 x (specied accuracy) per °C [0°C to
19°C (32°F to 66°F), 28°C to 50° C(82°F to 122°F)]
APO (Auto Power O): Approx. 30 minutes. Disable APO by
holding the MAX/MIN button while turning on the meter. APO
will not show on the LCD. APO is disabled in any wireless mode.
Backlight: Bright blue backlight. Approx 3 minutes.
Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life: 100 hours typical alkaline
Low battery indication: Battery icon will be empty ( ). "bAtt"
displays along with a continuous beep when the battery voltage
drops below the operating level. Meter shuts o in 5 seconds.
Dimensions: 165mm(H) x 78mm(W) x 50mm(D)
Weight: Approx. 315g including rubber boot
Overload protection: 600 VDC or 600VAC rms unless otherwise
stated. 15 seconds on 500mV range.
Test leads: Use the test leads that are supplied with the meter or UL
listed test leads rated CATIII 600V or above.
Safety: Designed to meet IEC 61010-1(EN 61010-1), CAT III 600V,
Class II, polution degree 2, indoor use and comply with CE.
UL61010-1.
06
Functions
Wireless Receiver Mode
Use your LT17AW to wirelessly receive
measurements from any Fieldpiece wireless
transmitter you have set up on the jobsite.
LT17AW
1. Select RECV switch position. Hold SYNC but-
ton for one second. Search pattern initiates.
Fieldpiece Transmitters
2. Connect any Fieldpiece accessory head to a
Fieldpiece transmitter.
3. Select DC switch position for all accessory
heads except ACH4 (AC switch position).
4. Hold SYNC button for one second.
Note: When a connection is made, the signal
strength and battery life of the partner de-
vice will be displayed on top of the LT17AW
screen. If no partner device is found within
two minutes, the LT17AW will stop searching.
Wireless Transmitter Mode
Transmit measurements wirelessly direct
from LT17AW or from an attached Fieldpiece
accessory head to Fieldpiece wireless receivers,
which lets you be in multiple places at once.
07
LT17AW Sending Direct Measurements
1. Select any switch position other than RECV.
2. Hold SYNC for one second until meter beeps.
Search pattern will initiate on LCD.
Fieldpiece Receivers
3. Select RECV switch position. Hold SYNC button for one second. For HG3, highlight the test
line and hold SYNC button for one second.
Note: When a connection is made, the signal
strength to the partner device will display on
LT17AW. If no partner device is found within
two minutes, the LT17AW will stop searching.
LT17AW Transmitting Accessory Head Reading
1. Connect any Fieldpiece accessory head to the
LT17AW by removing the probe tips from test
leads and plugging into accessory head plugs.
Insert test leads to COM and VΩ ports.
2. Selec t a mVDC range for all accessories except
for ACH4 (mVAC range).
3. Hold the SYNC button for one second.
4. Follow "Fieldpiece Receivers" section above.
Wireless Auto-Connection
When powered on, LT17AW will search
and connect to the last connected single-link
partner device (LT17AW, ET2W, or EH4W).
08
Temperature (°F/°C)
Plug any K-type thermocouple directly into the meter to measure
temperature. Cold junction is located “inside meter” and allows for
extremely accurate measurements even in rapidly changing ambient
temperatures (going from rooftop to freezer). No adapter is required.
See Temp Calibration section for calibration instructions.
Range: -30°F to 1400°F, (-35°C to 750°C) Resolution: 0.1°
Accuracy: ±(1°F) 32°F to 120°F, ±(1°C) 0°C to 49°C
±(1%+1.5°F) 32°F to 750°F, ±(1%+1°C) 0°C to 399°C
±(3%+4°F) -30°F to 32°F, ±(3%+3°C) -35°C to 0°C
±(3%+4°F) 750°F to 1400°F, ±(3%+3°C) 400°C to 750°C
Sensor type: K-type thermocouple
Overload protection: 30 VDC or 30VAC rms
Voltage AC (VAC) (50Hz-500Hz)
Test power lines (120, 220, 480), test 24V going to controls, and
test for transformer failure.
Ranges: 500mV, 5000mV, 50V, 500V, 600V Resolution: 0.1mV
Accuracy: ±(1.2% + 6) 500mV to 50V ranges
±(2%+6) 500V and 600V ranges
Input Impedance: 10MΩ
Voltage DC (VDC)
Select VDC and the range will automatically be selected to give
the best resolution.
Ranges: 500mV, 5000mV, 50V, 500V, 600V Resolution: 0.1mV
Accuracy: ±(0.5% + 3)
Input impedance: 10MΩ
09
10
500m
RECV
500µ
50m
200m
500m
RECV
500µ
50m
200m
5000m
500m
RECV
500µ
50m
200m
50
5000m
2
K
200
5000m
2
K
200
50
2
K
200
600600
500
20
20
500
50
20
20
500
20
20
M
200
M
200
M
200
500
50
5000m
500m
500µ
50m
200m
500
750
500
1400
K
2
200
K
600600
500
50
5000m
500m
500µ
50m
200m
500
750
500
1400
K
2
200
K
600600
500
50
5000m
500m
500µ
50m
200m
500
750
500
1400
K
2
200
K
FUSED
Unplug Leads and Slide
TEMP Switch to the Left
15 SEC FOR
RANGE
CAT.III
600V
500mV
MAX
FUSED
200mA
MAX
30V
MAX
Amps DC (ADC) Test Leads
Microamps for ame rectier diode test on a heater control.
Connect leads between ame sensor probe and control module and
turn heating unit on to read µA measurement. When the ame is on,
there should be a measurable µADC signal, typically under 10µADC.
Compare measurement to manufacture’s specication to determine
if replacement is necessary.
Ranges: 500µA, 50mA, 200mA Resolution: 0.1µA
Accuracy: ±(1.0% + 3) Voltage burden: 800mV
Input Protection: 0.25A / 500V fast blow ceramic fuse
Amps AC (AAC) Test Leads
Measure amps AC directly in the circuit. Measure small
amperages in ne circuitry.
Ranges: 500µA, 50mA, 200mA Resolution: 0.1µA
Accuracy: ±(1.5% + 6), 50Hz to 500Hz
Voltage burden: 800mV
Input Protection: 0.25A / 500V fast blow ceramic fuse
500m
RECV
500µ
50m
200m
5000m
500m
RECV
500µ
50m
200m
5000m
2K
200
50
2
K
200
500
50
20
600600
500
50
5000m
500m
500µ
50m
200m
500
750
500
M
20
200K
1400
K
2
200
Resistance (Ω)
Used for “ohming out” a motor. 0.1Ω resolution is necessary to
test the resistance between the motor poles because the values are
typically very low.
Ranges: 200Ω, 2kΩ, 200kΩ, 20MΩ
Resolution: 0.1Ω Overload Protection: 500VDC/VAC rms
Accuracy: ±(1.0% + 4) 200Ω to 200kΩ, ±(2% + 4) 20MΩ range
Open Circuits Volts: 0.3VDC typical, (2.5VDC on 200Ω range)
Overload Protection: 500VDC or AC rms
5000m
500m
RECV
500µ
50m
200m
500
50
2
K
200
20
600600
500
50
5000m
500m
500µ
50m
200m
500
750
500
M
20
200
1400
K
2
200
K
Amps AC (AAC) Through the Clamp
Test any isolated power line. Turn the dial to 500mVAC switch
position. Plug tests leads into COM and VΩ ports on meter. Remove
probe tips from test leads and plug leads into ACH4 banana plugs.
Range: 1-400A Resolution: 0.1A Frequency: 50-60Hz
Jaw Opening: 1.2in (30 mm)
Accuracy: ±(2.7% + 8) on 1-20AAC
±(3.7% + 9) on 20-100AAC
±(4.7% + 11) on 100-400AAC
Note: Above stated accuracies are a system accuracy combining both
the ACH4 and LT17AW accuracies.
500
20
600600
500
50
5000m
500m
500µ
50m
200m
500
750
500
M
20
200
1400
K
2
200
K
Continuity (
)
Use the continuity feature to test if a circuit is open or closed.
Use this feature to check fuses as well. A steady “beep” to indicate
continuity in a circuit.
Response time: 100ms
Audible beep: <100Ω
Overload Protection: 500VDC/VACrms
5000m
500m
RECV
500µ
50m
200m
500
50
2
K
200
20
600600
500
50
5000m
500m
500µ
50m
200m
500
750
500
M
20
200
1400
K
2
200
K
500m
RECV
500µ
50m
200m
5000m
2
600600
500
500
50
K
200
20
20
50
5000m
500m
500µ
50m
200m
500
750
500
1400
M
K
2
200
200
K
400A
300V
COM
ACH4
!
400AAC MAX
1AAC / 1mVAC
Clamp
AC Current
CAT.III
CLAMP
Capacitance (MFD)
Set to MFD to test motor start and run capacitors. Capacitors
are one of the most failure prone components in a HVAC/R system.
Discharge capacitor and disconnect from power and resistors
between terminals before testing.
Ranges: 20µF, 200µF, 2kµF Resolution: 0.01µF
Accuracy: ±(4% + 10)
Input Protection: 0.25 / 500V fast blow ceramic fuse
11
Safety Information
• Never ground yourself when taking electrical
measurements. Do not touch exposed metal
pipes, outlets, xtures, etc., which might be
at ground potential, while taking measure-
ments. Keep your body isolated from ground
by using dry clothing, rubber shoes, rubber
mats, or any approved insulating material.
• Disconnect the test leads before opening the
case. Inspect the test leads for damage to the
insulation or exposed wire. Replace if suspect.
Keep your ngers behind the nger guards
on the probes while taking measurements.
• When disconnecting from a circuit, disconnect
the “RED” lead rst, then the common “BLACK”
lead. Use one handed testing when possible.
Work with others.
• Turn o power to the circuit under test before
cutting, unsoldering, or breaking the circuit.
• Do not measure resistance (ohms) when circuit
is powered. Isolate load by disconnecting
from circuit.
• Disconnect the meter from the circuit before
turning any inductor o, including motors,
transformers, and solenoids. High voltage
transients can damage the meter beyond
600600
500
50
5000m
500m
500µ
50m
200m
500
750
500
M
20
K
200
1400
K
2
200
Discharge Cap First!
5000m
500m
RECV
500µ
50m
200m
500
50
2K
200
20
12
repair. Do not use during electrical storms.
• Do not apply more than rated voltages between
input and ground.
• Isolate capacitors from system and discharge
them safely before testing.
• Temp switch to prevent leaving thermocouple
plugged in while measuring voltage.
All voltage tests: All voltage ranges will with-
stand up to 600V. Do not apply more than
600VDC or AC rms.
Symbols used:
Caution, risk of electric shock
Caution, refer to manual.
Ground
Double insulation
WARNINGS
DISCONNECT AND UNPLUG TEST LEADS before opening case.
DO NOT APPLY VOLTAGE greater than 30VAC or 60VDC to the
thermocouple or the jacks when the rotary dial is on °F. (Use
only k-type thermocouples)
REMOVE THE THERMOCOUPLE when taking voltage measurements.
DISCONNECT TEST LEADS when measuring temperature.
DO NOT APPLY VOLTAGE TO THE JACKS when the rotary dial is on
microamps. Even low voltages can cause a current overload and
potentially harm the meter.
Diode Test (
)
Test diodes for proper forward and reversed-biased functions.
Test current: 0.5mA (Approx.) Accuracy: ±(1.5% + 3)
Open Circuit Volts: 2.5VDC typical
Overload Protection: 500VDC/VACrms
13
Temp. Calibration
For accuracies of ±1°F, calibrate to a known
temperature. A glass of stabilized ice water
is very close to 32°F (0°C) and is usually very
convenient but any known temperature can
be used.
500mV
FUSED
15 SEC FOR
RANGE
CAT.III
MAX
600V
30V
MAX
1. Select the 500°F range.
2. Plug thermocouple to be
calibrated into the K-type jack.
4. Stabilize a large cup of ice water.
Stir the ice with the water until
temperature stays at 32°F (0°C).
5. Immerse the thermocouple probe and let it stabilize. Keep stirring
to prevent micro-environments.
6. Use a small screwdriver to adjust calibration pot to the lower left
of the COM port as close to 32°F as you would like.
Battery Replacement
The battery in the LT17AW must be replaced
when the lower left battery icon ( ) is empty.
The LT17AW will display "bAtt" on the LCD
accompanied by a continuous beep. The
meter will turn o in 5 seconds and no further
measurement will be allowed until the battery
is replaced.
FUSED
200mA
MAX
600600
5000m
500m
RECV
500µ
50m
200m
500
50
2
K
200
20
20
M
200
500
50
5000m
500m
500µ
50m
200m
500
750
500
1400
K
2
200
K
14
Maintenance
Clean the exterior with a dry cloth. Do not
use liquid.
Limited Warranty
In the USA, this meter is warranted against
defects in material or workmanship for one year
from date of purchase. Fieldpiece will replace or
repair the defective unit, at its option, subject to
verication of the defect.
This warranty does not apply to defects
resulting from abuse, neglect, accident,
unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arising from the sale of
a Fieldpiece product, including but not limited
to implied warranties of merchantability and
tness for a particular purpose, are limited to
the above. Fieldpiece shall not be liable for loss
of use of the instrument or other incidental or
consequential damages, expenses, or economic
loss, or for any claim of such damage, expenses,
or economic loss.
State laws vary. The above limitations or
exclusions may not apply to you.
CLAMP
300V
CAT.III
RECEIVE
SEND
SYNC
AC Current
Clamp
1AAC / 1mVAC
400AAC MAX
ACH4
ET2W
Wireless
Transmitter
400A
!
ET2W w/ ACH4
transmitting
wirelessly to
AC
DC
ON
LO BATT
LT17AW
AUTO-OFF
WIRELESS
ENABLED
MAX/MIN
SYNC HOLD
600600
500
500
50
5000m
500m
RECV
500µ
50m
200m
K
2
200
20
M
20
K
2
200
K
200
m
500
15 SEC FOR
RANGE
CAT.III
MAX
600V
FUSED
50
5000m
500m
500µ
50m
200m
500
750
500
1400
V
FUSED
A
m
200
MAX
30V
MAX
15
Obtaining Service
In the USA, call Fieldpiece Instruments for
one-price-x-all out of warranty service pricing.
Send check or money order for the amount
quoted. Send the meter freight prepaid to
Fieldpiece Instruments. Send proof of date and
location of purchase for in-warranty service.
The meter will be repaired or replaced, at the
option of Fieldpiece, and returned via least
cost transportation. Outside of the USA, please
visit www.eldpiece.com for service contact
information.
www.fieldpiece.com