
Fieldpiece
COM
CAT III
600V
Fieldpiece
Select
M/m
SC260
TRUE RMS
V
AC
NCV
A
AC
°F°C
V
DC
MFD
TEMP
AUTO OFF
TYPE K
30V
MAX
PEAK
MUTE
ON/OFF
ON/OFF
L/M/H
SENSITIVITY
H
M
L
PEAK
LOW-BATT
PRESS FOR
1 SECOND
SRL2
Infrared
Refrigerant
Leak Detector
BATTERY
CHECK
SRS1
RECOVER
CHARGE
REPEAT
123
ENTER
456.
UNITS
EXIT
ON/OFF
PRESS 1 SEC
ZERO
PRESS 1 SEC
PRESS 1 SEC
7
LIGHT
890
Refrigerant Scale
with Weight Alarm
OPERATOR'S MANUAL
Model SRS1
ON/OFF
PRESS 1 SEC
123
456.
LIGHT
7
Fieldpiece
REFRIGERANT SCALE
SRS1
CHARGE
RECOVER
REPEAT
890
with ALARM
Quick Start
1 Install the 9V battery into the controller.
2 Place the platform on solid, level ground for
best accuracy.
3 Press ON/OFF for 1 second to turn on the scale.
4 Press UNITS for 1 second to switch between
LB, LB OZ, OZ and KG.
5 Press ZERO for 1 second to tare the scale.
6 Read weight directly on the display.
Certifications
ENTER
EXIT
UNITS
PRESS 1 SEC
ZERO
PRESS 1 SEC
CE
WEEE
RoHS Compliant
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Description
Your new SRS1 refrigerant scale will be
with you day in and day out for charging and
recovery. It's just big enough to t a canister
and has the ruggedness you expect. No wasted
material. The walls are made of thick aluminum
to maintain accuracy over the life of the product.
Hang the controller on a vented condenser
so it's easy to see, and use the backlight when
the sun's going down late in the day. The
magnetized back holds it tight.
Quickly set the charge/recover alarm using
the big numeric key pad- no more scrolling
digits. Set the tank on the platform, dial in how
much you want to charge, and wait for the alarm
to tell you it's time to close the valve.
Throw it over your shoulder when you need
your hands free to carry other equipment or to
climb up a ladder.
Rubber feet and a rubber pad soften the
impact of daily use. Your new scale is easy to
use and does what you need. It has all the right
stu for HVACR.
Specifications
Specications good in ambient conditions of 73°F ±9°F
(23°C ±5°C), <75% relative humidity
Over range: "OL" is displayed and beep sounds
Maximum load: 110 lbs (50kg)
Auto power o: 30 minutes of inactivity (no change in weight or
buttons pressed), (APO disabled in charge/recover mode)
Backlight: Blue, turns o in 60 seconds if no buttons are pressed
Accuracy: ±(0.05%rdg + 10g)
Resolution and Units:
LB OZ (1 LB, 0.25 OZ), LB (0.02 LB), OZ (0.25 OZ), KG (0.01 KG)
Temperature coecient: 0.1 x (specied accuracy) per °F
Battery: 9V, NEDA 1604, JIS 006P, IEC 6F22
Battery life: 80 hours typical alkaline (without backlight)
Low battery indication: is displayed when the battery
voltage drops below the operating level
Operating environment: 32°F to 122°F (0°C to 50°C) at <75% RH
Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH
(with battery removed)
Weight: 6.6 lbs (3.00 kg)
Maintenance
Clean the exterior with a dry cloth. Do not
use liquid.
The battery must be replaced when the
battery life indicator is empty. Remove
rear battery cover and replace with 9V battery.
Limited Warranty
This meter is warranted against defects in material or workmanship
for one year from date of purchase from an authorized Fieldpiece dealer.
Fieldpiece will replace or repair the defective unit, at its option, subject
to verication of the defect.
This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arising from the sale of a Fieldpiece product,
including but not limited to implied warranties of merchantability and
tness for a particular purpose, are limited to the above. Fieldpiece
shall not be liable for loss of use of the instrument or other incidental
or consequential damages, expenses, or economic loss, or for any claim
of such damage, expenses, or economic loss.
State laws vary. The above limitations or exclusions may not apply
to you.
Obtaining Service
Email Fieldpiece warranty department for current fixed price repair
service. Send check or money order made out to Fieldpiece
Instruments for the amount quoted. If your meter is under warranty
there will be no cost for the repair/replacement. Send your scale,
freight prepaid, to Fieldpiece Instruments. Send proof of date and
location of purchase for in-warranty service. The meter will be
repaired or replaced, at the option of Fieldpiece, and returned via
least cost transportation.
For international customers, warranty for products purchased
outside of the U.S. should be handled through local distributors. Visit
our website to nd your local distributor.
Visit us at www.TestEquipmentDepot.com
01 02 03 04 05
Functions
Weight Alarm
Tech Tips
You can set the alarm to sound when
Weight Measurement
Your SRS1 scale is designed to measure
refrigerant tanks weighing up to 110 lbs.
Note: Placing items over 110 lbs on the scale may
damage the scale.
approaching a set weight. This is useful when
you know how much you want to add or remove
from the system and you want to work on other
things nearby. It is best to do a practice run
before using on a job so you know how it works.
1 Remove the scale from the padded case and
place the platform on solid, level ground.
2 Press ON/OFF for 1 seconds to turn on the
scale.
3 Press UNITS for 1 second to switch between
LB, LB OZ, OZ and KG.
4 Press ZERO for 1 second to zero(tare) the scale.
5 Set your tank on the platform and zero again
to view only the change in refrigerant.
6 View the change in weight in real-time when
charging or recovering refrigerant.
01 02 03 04 05
Backlight
the LCD. This is useful when the sun is going
down on late day jobs or any dark situation.
The backlight uses extra battery power than
standard use.
06 07 08 09 10
Press LIGHT to turn on the blue backlight on
1 Set the tank on the platform
2 Select desired units.
3 Press CHARGE or RECOVER.
4 Use the number keys to enter how much re-
frigerant you want to add (charge)or remove
(recover). If in LB OZ mode, press ENTER to
move to OZ.
5 Press ENTER.
6 The display will now show 0.0 and you can
begin charging or recovering.
7 The alarm will sound when the weight gets
close to the weight you entered, so you know
when to close the valve.
8 Press ENTER/EXIT to exit CHARGE/RECOVER
mode.
9 Press REPEAT to automatically set the alarm
to the last entered weight.
Respect the Environment
Always use hoses with ball valves or low-loss
ttings to minimize harmful refrigerant gases
entering the atmosphere.
Account for Your Hose Weight
Connect the hoses to the system and tank
before zeroing the scale. After charge/recovery
is nished and the system is stable, note the
weight before removing hoses.
Test Equipment Depot - 800.517.8431
99 Washington
TestEquipmentDepot.com
Street Melrose, MA 02176
Other Great Tools
Digital Manifolds
Leak DetectorsMade in China Clamp Meters