WPC-1
Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
Installation Instructions: Read these instructions in
their entirety before performing any installation work.
FOR USE WITH POOL AND SPA PRODUCTS
ETL LISTED
Conforms to UL STD 508;
Certified to CSA STD
C22.2 No. 14
http://www.fiberstars.com
79-15053-00 REV. C Page 1 of 16
The WPC-1 consists of the following parts:
Item No. Qty. Component part No. Description
1 1 - WPC-1 Enclosure
2 1 94-15087-00 WPC-1 Enclosure Door
3 1 37-15000-00 Relay
4 1 41-15004-08 8 Position Terminal Block
5 1 42-15032-00 Timer
6 1 02-15268-00 Face Plate
7 2 02-15274-00 WPC-1 Mounting Bracket
8 1 41-15003-00 Grounding Bar
9 1 94-15090-00 WPC Receiver
10 6 10-15086-04 Face Plate and Mounting Bracket Screws
11 2 10-15089-06 Terminal Block Mounting Screw
12 2 10-15060-01 Relay Mounting Screw
13 8 10-15089-03 Timer and Receiver Mounting Screws
14 2 A11526 3-Position Toggle Switch
15 1 94-15092-00 WPC Repeater
16 2 10-15089-02 Freeze Device Mounting Screw (Optional equipment)
17 1 20-15013-00 Strain Relief
18 1 17-15005-00 Latch
19 2 10-15089-01 Latch Mounting Screws
Accessory Items:
FP 1/2 Temperature Freeze Device
WE-65 65 ft Repeater Cord Extension Kit
DL-HUB Direct Light Hub Connection Kit
WPC-12V 12V Transformer for Fiberstars Light Streams LED Products
10
14
2
13
12
9
11
4
3
5
16
15
10
7
1
19
18
17
8
6
http://www.fiberstars.com
79-15053-00 REV. C Page 2 of 16
IMPORTANT SAFETY INFORMATION
Basic safety precautions should be observed when operating the WPC-1 product and other
associated equipment.
1. A qualified electrician must install the WPC-1 in accordance to the National and Local
Electrical Codes.
2. The WPC-1 must not be less then 5 feet (3 meters in Canada) from inside edge of pool.
ONLY USE COPPER CONDUCTORS.
3. Do not exceed the maximum ratings of individual components, wiring devices, and current
carrying capacity of conductors.
4. For the bonding, grounding, installing, and wiring of underwater lights to the WPC-1, refer
to Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code.
5. This device should never operate equipment that could cause property damage, bodily
injury, or death should it be activated unexpectedly.
-
FCC WARNING
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
2. Changes or modifications not expressly approved by Fiberstars Inc. could void the user's
authorit
ELECTRICAL RATINGS
Do not exceed the maximum electrical ratings of the WPC-1. A circuit breaker rated at 20Amps
at 120VAC must be installed in the breaker panel to connect to the WPC-1 power input. Circuit
1 and Circuit 2 are each rated for use of up to 8Amps @ 120VAC. The Pump Relay is rated at
maximum of 3HP @ 240VAC.
to operate the equipment.
http://www.fiberstars.com
79-15053-00 REV. C Page 3 of 16
WARNING
• TURN OFF INCOMING POWER BEFORE SERVICING EQUIPMENT.
• ALL INSTALLATION AND MAINTENANCE WORK MUST BE PERFORMED BY
QUALIFIED ELECTRICAL PERSONELL ONLY.
• VERIFY ALL ELECTRICAL RATINGS BEFORE INSTALLATION IS COMPLETE.
LOCATION
Install the WPC-1 enclosure using the mounting plates included with each enclosure. The WPC1 is housed in a Type 3R rainproof enclosure and can be mounted anywhere between the pool
equipment and the breaker panel.
WIRING INSTRUCTIONS
FOLLOW PROPER WIRING PRACTICES IN ACCORDANCE WITH ALL LOCAL
REGULATORY REQUIREMENTS.
Power Connections:
To wire the WPC-1 use insulate
COPPER wire only, 12 gauge minimum.
Run a ½” to ¾” conduit from the main
breaker panel to the WPC-1. Pull
appropriate wires from the main breake
anel to the WPC-1 unit. To make powe
connections remove 3/8 inches of
insulation from wire ends. Insert the bare
end of wires under the pressure plate o
terminals (Power Input, HOT). Use 1/8in. flat head screwdriver to tighten
terminal screws firmly (4.4 lb-in
minimum). Connect the house common
to the Power Inputs NEUTRAL terminal.
Connect another HOT wire to the
Timeclocks T/C POWER terminal.
Connect a house common to the
Timeclocks T/C NEUTRAL. Install a 20
Amp circuit breaker in the main breake
anel and connect the HOT wires from
the WPC-1.
T/C POWER
T/C NEUTRAL
http://www.fiberstars.com
79-15053-00 REV. C Page 4 of 16
HOT
NEUTRAL
Power Connection with GFCI
To wire the WPC-1 with the use of
GFCI, punch out the GFCI knockou
on the side of the WPC-1 enclosure.
Install an outdoor rated GFCI. Using
COPPER wire only, 12 gauge
minimum, connect the GFCI from the
LOAD side to the HOT terminal on
the POWER INPUT of the WPC-1.
Connect the NEUTRAL from the
LOAD side of the GFCI to the
NEUTRAL terminal from the WPC-1.
Connect the GROUND of the GFCI to
the EQUIP. GND. bar. Wire the HOT
from the GFCI’s LINE side to the
20Amp circuit breaker in the main
reaker panel as discussed earlier.
Connect the NEUTRAL from the
GFCI’s LINE side to the house
common. From the GFCI’s LINE
side, connect a wire from the HOT to
the Timeclocks T/C POWER
terminal. From the NEUTRAL of the
LINE side on the GFCI, connect to the
T/C NEUTRAL on the terminal block.
NOTE: Do not connect the Timecloc
Inputs to the LOAD side of the GFCI.
T/C POWER
T/C
EUTRAL
120VAC 20AMP
HOT
DE
LINE SI
TO
EUTRAL BAR
EUTRAL
LOAD SIDE
ERCIRCUIT BREAK
GROUND
HOT
LOAD SIDE
GFCI
http://www.fiberstars.com
79-15053-00 REV. C Page 5 of 16