Fiberstars JAZZ
J400AS (AUTO SYNC)
Owners Manual
www.fiberstars.com
Rev.F1 - 1 - P/N 75-15046-PM
CAREFULLY READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE LIGHT
AND ASSOCIATED EQUIPMENT.
HAZARDOUS VOLTAGE Incorrectly installed equipment may fail, causing severe injury or property
damage.
Have a certified electrician perform all tests before operating equipment.
To prevent the risk of damage or injury, do not operate the light out of water for more then 15 minutes.
Allow the light to cool down before installing underwater.
ATTENTION
Fiberstars JAZZ and FX Series Wet-Niche Lighting Fixtures for Swimming pools are now ETL Classified for use with the
following manufactures Wet-Niches for use in new Pool construction. PENTAIR, (American) model no. 79206700
(ABS), model no. 7821XXXX (S/S), 7823XXXX (S/S), model no. 620004 (ABS) HAYWARD, model no. SP0607U
(ABS, Vinyl) SP0600U (ABS, Concrete)
ETL Classification Report No. 3040481
ATTENTION
FIBERSTARS FX LIGHTS ARE UL LISTED FOR USE IN STA-RITE WET NICHE TYPE FIXTURE ONLY. Model
numbers, (S/S) 05161-2352, 05161-2353, 05161-2354, 05161-2355, 05161-2356, 05161-2357, 05161-2358, 05161-2359,
05161-2360, 05161-2361, 05161-2362, 05161-2363, 05161-2364, 05161-2365, 05161-2366, 05161-2367, 051161-2368,
05161-2369, (ABS) 05163-2394, 2395 & 2396
UL File No. E220601
Risk of electrical shock. Before removing fixture from pool wall, ALWAYS TURN OFF THE
POWER at the breaker.
Install this light and light niche in accordance with Article 680 of the National Electrical Code (NEC), in
the United States.
Install an approved Ground Fault Circuit Interrupter in the electrical circuit for this light.
All devices in the system must be directly grounded to a positive electrical ground. All devices in the
system must meet all applicable code requirements for bonding.
Operating pool light at a reduced voltage will diminish the lighting of your pool during nighttime use.
Failure to provide adequate lighting may result in swimming and diving hazards which can cause severe
injury or death
Rev.F1 - 2 - P/N 75-15046-PM
Figure 1
Install fixture in a vertical pool or spa wall – not in floor. Failure to install the fixture properly could result in personal
injury and/or property damage.
Except when the fixture is installed in an area of the swimming pool that is not used for swimming and the lens is
adequately guarded to keep any person from contacting it, the fixture shall be installed in or on the wall of the pool with
the top of the lens not less then 18 in. below the normal water level of the pool; see Figure 1.
The junction box must be located:
• At least 4’ from the perimeter of the pool (unless separated from the pool by a solid fence, wall or other
permanent structure,
• At least 8” above maximum water level,
• At least 4” above the deck or ground level.
Junction boxes should be located off the walkway around the pool and given additional protection by installing them next
to a fence, building, or other permanent structure. Make sure that the installation is in compliance with local codes, and
the NEC.
A Ground Fault Circuit Interrupter (GFCI) and an appropriately rated circuit breaker shall be installed in the branch
circuit supplying power to fixtures so that there is no shock hazard during re-lamping.
Lamp Housing Installation
Glass breakage hazard. Do not push off from the poolside against the light.
NOTE: For the J400AS 4 wires must be supplied to the junction box from the power supply.
Light Fixture Installation
1. Before installing light fixture, make sure power to light is off.
2. Feed cord through niche and conduit, while light fixture is on deck area right above the niche. Feed cord to
junction box leaving enough cord, about 3’ to allow fixture to be placed on deck to allow relamping.
3. Make connections in the junction box (see Figure 2).
Rev.F1 - 3 - P/N 75-15046-PM