Fiberstars 6004-AS Owner's Manual

DELIVER TO CONSUMER
6004 AND 6004-AS
OWNER'S MANUAL
SPECIFICATIONS
TOGGLE SWITCH POSITIONS
MANUAL CONTROL
COLOR WHEEL
ON
COLOR WHEEL
EXTERNAL AUTO CONTROL
COLOR WHEEL
OPTIONAL RM6000 CONTROL
POWER
ON
POWER
POWER
CONSTRUCTION Case: High Impact Polycarbonate Ventilation: 110 cu ft/min air volume Acoustic rating: 50dB(A) Weight: 20 lbs.
ELECTRICAL Voltage required: 120VAC 60Hz Power consumption: 200 Watts max Start current load: 4.4 amps Current usage: 1.8 amps LAMP Type: Metal-Halide, proprietary design Lamp life: 6000 hrs average Cool down restrike period: 3 minutes Replacement p/n: Y20-6000
WARRANTY See Enclosure
COLOR WHEEL
79-15016-00 REV B
44259 NOBEL DRIVE FREMONT, CA 94538 TEL(800)327-7877 FAX(510)490-3247 www.fiberstars.com
POWER
DO NOT ALLOW AIR VENTS TO BE BLOCKED!
AIR FLOW
AIR FLOW
MAXIMUM FINISHED SOIL HEIGHT
Your 6004 / 6004-AS illuminator needs air to breathe! Lack of ventilation can cause the unit to overheat. This will shorten the lamp life and could damage the unit. DAMAGE TO THE UNIT BECAUSE OF BLOCKED AIR VENTS IS NOT COVERED UNDER OUR WARRANTY!
TROUBLE SHOOTING
-THERE IS NO LIGHT
You can hear the fan running: The lamp has probably failed. Replace with Fiberstars part #Y20-6000 There is no fan running: The illuminator is not getting power. Check the toggle switch position by referring to the diagram on
the front of this manual. Check the GFCI breaker and check the fuse on the illuminator.
-THE UNIT SHUTS OFF AFTER A FEW MINUTES THEN COMES BACK ON
Check to see if the air vents are blocked. Refer to the above drawing to make sure the vents are clear Turn off the power and remove the two screws securing the cover and check for an obstruction in the cooling fan.
-REMOTE CONTROL UNITS (WITH OPTIONAL RM6000 PACKAGE-with its own seprate warranty coverage)
YOU CAN TEMPORARILY OPERATE THE UNIT MANUALLY VIA THE TOGGLE SWITCHES IF A REMOTE CONTROL
PROBLEM IS SUSPECTED. SEE THE DIAGRAM ON THE FRONT OF THIS MANUAL.
There is a click at the unit when the button is pressed, but no light: If you hear the fan running, the lamp has probably failed. Replace with Fiberstars part #Y20-6000. If you cannot hear the fan running, the receiver module is probably defective. Have a qualified service company replace it.
There is NO click at the unit when the button is pressed: Make sure that the transmitter is TURNED ON. The red light on the transmitter should glow when a button is depressed. If the transmitter is functioning properly, but the illuminator still does not come on, the receiver module may be defective. Have a qualified service company replace it. YOU CAN TEMPORARILY OPERATE THE UNIT MANUALLY VIA THE TOGGLE SWITCHES. SEE THE DIAGRAM ON THE FRONT OF THIS MANUAL.
-LIGHTS ARE NOT BRIGHT ENOUGH
The adequacy of pool lighting is subjective at best. What is acceptable to most, may not be for some. The pool builder is given guidelines by Fiberstars, and the builder alone is responsible for the final design and installation. There are many factors that determine the ultimate brightness of our product; fiber lengths, pool finish color, installation techniques, etc. Remember that darker colors on our color wheel, i.e. magenta, are not as bright as lighter colors like white.