Fetco EXTRACTOR CBS-1131V+, EXTRACTOR V+ Series, EXTRACTOR CBS-1151V+, EXTRACTOR CBS-1132V+, EXTRACTOR CBS-1152V+ Programming Manual

Page 1
Programming Guide
CBS-1100V+™
Models: CBS-1131V+; CBS-1132V+ CBS-1151V+; CBS-1152V+
(800) 338-2699 (847) 719-3000 techsupport@fetco.com www.fetco.com
© 2008-2018 Food Equipment Technologies Company Part # P172 January 2018
FETCO®, EXTRACTOR® and V+ are trade mark s or trade names of Food Equipment Technologies Company.
Page 2
A
A
(
)
A
A
A
Scroll Across (A-F)
(
)
PROGRAMMING MENU LAYOUT CBS V+ Series
[A] PROGRAM
[B] GENERAL [C] INPUTS [D] OUTPUTS [E] OTHER Batch A1. to A7 B1.0 to B1.7 C1.0 to C1.3 D1.0 to D1.5 E1.0 to E1.8 | | | | |
10 PERMANENT
Position A10&A40 are permanent
|
| | | |
| | | |
11 Brew Volume B1 Tank Temp C1 LLC Probe D1 Test Heater E1 Display Firmware
| | | | |
A12 Brew Time B2 [Brew at Temp] C2 B. Basket Sensor D2 Test Fill Valve E2 Sel. Brewer Model
| | | | |
A13 Prewet Percent B3 LLC Sensitivity C3 Tank water temp. D3 Test R. Brew Valve E3 Display Errors
Scroll Down
| | | | |
A_4 Prewet Delay
only when prewet % >0%
B4 Temperature F/ C C4 Keypad Test D4 Test L. Brew Valve E4 Clear Errors
| | | |
A16 Drip Delay B5 Volume unit G or L D5 Screen Brightness E5 Reload Defaults
1-8
| | |
A20 Batch ACTIVATE? B6 Left Flow Rate E6 Save to USB
| | |
30 Batch ACTIVATE? B7 Right Flow Rate E7 Load through USB
| | |
40 PERMANENT B8 Slow Mains Flow E8 Demo Mode
|
A50 Batch ACTIVATE?
|
A60 Batch ACTIVATE?
|
70 Recipe Copy? Use this chart to quickly locate and access programming topics. The topics are in groups A-E in this guide. “F” screen is Save and Exit Check the user guide for more comprehensive details of the brewer settings. User guides are located online at fetco.com in Service-Resources….or use our QR code
Page 3
Popular Operator Control Settings Default Settings-(Factory Settings)
CBS-1131V+
CBS-1151V+
Parameter Name
CBS-1132V+
CBS-1152V+
A11 Brew Volume 3 LTR 1.5 GAL A12 Brew Time (Min:Sec) 4:00 4:00 A13 Prewet Percent 0% 0%
Prewet Delay (Min: Sec)
A14
1:00 1:00
This appears only when Prewet >0%
A16 Drip Delay (Min:Sec) 1:30 1:30
B1 Hot Water Tank Temp. 200 F 200 F B2 Brew at Set Temperature “YES” [ON] “YES” [ON] B3 LLC Sensitivity (See User Guide) “LOW” LOW” B4 Temperature Scale F F B5 Water Volume Scale Liters Gallons
1.55 LPM 3.40 LPM
B6 & B7 Brew Valve Flow Rate
FLOW rate is in Liters/Min even if brewer is in Gallons
Batch Activate
A(20, 30&50,60)
[Batches on buttons 2&3 and 5&6 if dual]
Go to Parameter E5 to reset all settings to factory defaults.
Yes-Active Yes-Active
Page 4
HOW TO ENTER PROGRAMMING MODE TO ACCESS CONTROLS AND DIAGNOSTICS
)
g
A
A
1)Turn the brewer off by pressing the power switch. Turn power switch “ON”
2
DISPLAY
-The display will progress through startup screens.
Example:
Brewer and version code
CBS-1132V+
v 1 . 0. 1744
-The STOP button will illuminate. As shown—right
3)-Quickly press the STOP button (no need to hold)
-Brewer is now in PROGAMMING MODE
Menu Topic
-F
Menu Position
1-7
Toggle Setting
UP or [YES]
4)Press the STOP button to advance the menus
across the top A-F and back to START (“A”)
Toggle Setting
DOWN or [NO]
5)Press 1 to ent er menus for individual settings under letter
NOTE: Buttons li
ht up only when they are available to make adjustment
Batch Settings
dvance through settings
CBS-1132V+
STOP
1 2
3
STOP
CBS-1132V+
The menu topics are numbered A1-A7; B1-B8 -etc…
-Press button 1 to select recipe programming
Position name, topic & reference position show in display.
First programming position
A11 is shown in example
BREW VOLUME
A11 3.00 L ±
-Toggle buttons 2 and 3 to make changes.
STOP
1
2
3
STOP
-Then press button 1 to advance to next programming topic.
Page 5
To change recipes
A
Illustration shows each recipe batch position
All recipe programming is made from the “A” screens TO ACCESS BATCH RECIPES:
CBS-1132V+
STOP
STOP
-Enter “A”-BATCH PRG
10
-Press button “A10” to scroll through the parameters
A20
Press “STOP” to scroll across the other recipe buttons Single brewer has 3 recipes. Twin brewer has 6 recipes
A30
-All recipe settings are programmed from the “A” screen. Each recipe button may be individually programmed. Top recipe buttons (A10&A40) are permanent. Lower recipe buttons (A20, A30&A50, A60 if dual can be hidden. To hide or deactivate a button: toggle the BATCH ACT screen.
A11 screen sets the total brew volume
Note
:
some water is retained in the used coffee grounds
BATCH ACT
A20 YES –
BREW VOLUME
A11 3.00 L ±
Toggle to NO to deactivate
or hide lower recipes
First programming position A11 is shown in example
A40
A50
A60
-Scroll down (press button A10) to the next setting A12 to set brew time to dispense the volume set in A11.
Note: goes to default setting if set too short for volume entered
BREW TIME
A12 04:00 ±
Second programming position A12 is shown in this example
- Press A10 button continue scrolling down through A13-A15 for all recipes. (See user guide for detailed explanation of each parameter)
Page 6
-After all brew recipes are set press STOP button to go to–GENERAL “B” B1 is Tank Tem p era tu re
This controls the brew water temperature and the hot water service faucet Toggle buttons A20 and A30 to make changes Then press A10 to advance
Tank Temp
B1 200F ±
First programming position “B1” Is for hot water tank temperature
B2 is Brew at Temperature Default is YES. Brew will not start until
Brew @ Temp B2 YES -
Brew pauses & will start when hot water tank temp. is at setpoint
hot water tank temperature is at setpoint. If Brew at Temp is set to “NO”-brew will start at any temperature above 77°C/170°F. Toggle buttons A20 & A30 to adjust Then press A10 to advance
-Following the PROGRAMMING MENU LAYOUT chart shown on page 2 Complete your adjustments in the GENERAL –“B” paramete r
- Settings found under BATCH PROGRAM “A” GENERAL “B include most needed for start-up and operation.
-Always verify the model number (displayed when brewer first powered ON). Model selection is found in E2
-Always SAVE & EXIT as shown in screen “F” or new settings will be lost. Press A10 to advance though the settings to change or check settings
-then press STOP to continue scrolling across C-E positions
Page 7
Batch Parameters –A-MENU and PROGRAMMING
Brewers are shipped with all recipe batch buttons enabled and set to the defaults shown in A1-A6. These are full batches. Adjust settings of the individual recipes under batch PRG “A”
Position Name and default setting Range Comment
A.20,30 A.50,60
A1
A2 A3 A4 A6
Batch Enabled or Disabled
Brew Volume
3 liters CBS-1130V+
1.50 gal CBS-1150V+ Brew Time (Min: Sec)
4:00 Prewet Percent 0% Prewet Delay 00:00 (Min:Sec) Drip Delay 1:30 (Min:Sec)
The top batch on each side
YES/NO
cannot be disabled. (A10&A40)
CBS-1130V+
0.95 – 4.75 (Liters) CBS-1150V+
To switch between gallons and liters, go to position B5
0.50-2.00 (Gallons) Factory default total brew is 5:30
2:00 – 12:00
(4:00 brew time+1:30 drip delay)
0.00 – 15.0% 0:10 – 5:00
Prewet must be > 0%
Percentage of total brew volume. The time between end of prewet cycle and start of brew cycle.
0:30 – 6:00 Minutes Brew switch continues to flash.
Page 8
B-E Advanced Settings and Diagnostics
Batch Parameters – B-GENERAL settings
Position Name and default setting Range Comment
B1 B2 B3 B4 B5 B6 B7
Tank Temperature 93° C -or- 200°F Brew at Temp. Setpoint “YES” LLC Sensitivity “LOW” Temperature Scale “°F” Fahrenheit Volume Scale L-(
CBS-1130) G-(CBS-1150)
LEFT brew valve flow rate
NOTE: flow rate only in liters per min
RIGHT brew valve flow rate
NOTE: flow rate only in liters per min
70° to 96°C 157° to 205°F
YES/NO LOW/HIGH °F/°C
Liters/Gallons User adjustable
CBS-1130 1.55L/0.40G
CBS-1150 3.40L/0.9G
CBS-1130 1.55LPM CBS-1150 3.40LPM
NOTE: Equipment factory default is set for metric Batch to start when at set temperature: SEE USER GUIDE High is only for low mineral or R.O water SEE USER GUIDE NOTE: Changing will overwrite user settings
CBS-1130V+ factory set in liters CBS-1150V+ factory set in gallons
Adjusts the brew valve flow rate.
SEE USER GUIDE
Adjusts the brew valve flow rate.
SEE USER GUIDE Trims fill system for low flow from supply
B8
Mains low flow
NO/YES
“NO”
Page 9
Batch Parameters – C-INPUTS controls & conditions
Position Name and default setting Range Comment
LLC Probe Continuity
Reading of tank water
Reading of tank water resistivity
C1
Direct Read
resistivity in TDS
in TDS
C2 Brew Basket Sens or YES/NO YES or NO
Tank Temp.
C3
Direct Read
Hot water tank
Hot water tank temperature
temperature
Checks buttons under
C4 Keyboard Test All buttons
membrane cover
Batch Parameters – D-OUTPUTS settings
Position Name and default setting Range Comment
D1 Heater Test
ON/OFF
10 seconds maximum ON time
ON/OFF
D2 Fill Valve Test
10 seconds maximum ON time
Energizes Heaters! For diagnostics/service use only
Tests Fill Valve
D3 Left Valve Test
10 seconds maximum ON time
Tests Left Brew Valve
ON/OFF
ON/OFF
D4 Right Valve Test
10 seconds maximum ON time
NOTE: If heater or valve are switched “ON” for testing they will automatically turn “OFF” in ten (10) seconds
LCD Brightness
D7
0-15
Default is 8
Tests Right Brew Valve Adjust LCD screen brightness
only-Not for LEDs under buttons
Page 10
Use this formula to compensate for minor discrepancies in actual volume versus programmed volume
=
New
Use this formula to determine the new setting: Enter new setting in B6 or B7 -See user guide.
Measured Volume
Current
X
Programmed Volume Setting Setting
Use the formula above to compensate and fine-tune brew volume. TIP:check flow from supply for fouled water filter
Brew valve flow rates are in liter/min Enter the New Setting value into B6/B7 and save as in the “F” screen.
HINT: Set lower to incr ease volum e, hi gher to decreas e volum e.
Use this to compensate for minor discrepancies in actual volume versus programmed volume.
E3-Error Codes
DO NOT CLEAR ERROR CODE S UNTIL ERROR IS IDENTIFIED AND/OR CORRECTED Contact specialized personnel for error codes
Code Description Possible Cause Corrective Action
Software error-error on start up or
001
corrupted software 050 Short-circuit in temperature probe 051 Open temperature probe.
Initial Fill Error. Initial fill time took
100
longer than expected after power up.
Improper start-up or shutdown Restart , if still fault: reload software Probe failure. Replace probe.
Bad probe connection, or probe failure. Check all connections. Replace probe if necessary. Water supply flow rate is too low.
Watch for short potting during brew cycle. Investigate cause of low flow rate. (Clogged water filter...)
Error on refill-. Tank did not refill within
101
Water supply flow rate is too low.
expected time.
Heater open, high limit thermostat
201
or Solid-State Relay (SSR) fault 255 Touch pad error
NO
Insert Brew Basket
BSKT
Consult the user guide for your brewer for more complete information
Failure of: heating element, SSR, high Limit or low voltage
Keyboard contact longer than 2 min Or faulty reassembly
Brew basket must be in place This is a SAFETY FEATURE
Watch for short potting during brew cycle. Investigate cause of low flow rate. (Clogged water filter…)
Check and replace heating elements if necessary. Restart , if still fault: reload software. If mechanical:
replace membrane switch or control module Insert brew basket into brewer rails to enable brewer
Page 11
Batch Parameters – E-OTHER software and code settings
Position Name and default setting Range Comment
E1 Display Firmware 1.0.1744 Displays current version
CBS-1131
NOTE: Will need reboot
CBS-1132
E2 Select Model
CBS-1151 CBS-1152
1=Newest/6=Oldest
COMPLETELY OVERWRITES ALL USER SETTINGS
See Error Code Chart
E3 Display Errors
LAST six errors only
for references Resetting error codes should be after completing the servic e and factory diagnostics and correcting any brewer faults. Clear error codes by cycling the brewer “OFF” then “ON”.
NOTE: Always contact FETCO
E4 Reset Errors YES/NO
Technical Service for errors
(800)338-2699
Reset to default of
NOTE: COMPLETELY OVERWRITES
E5 (Reload) DEFAULTS
base model
ALL USER SETTINGS
E6 USB Data Save Save data to USB E7 Load From USB Will need reboot Plug in USB flash-drive dev ice
Demonstrates the controls for
DEMO Mode
ON/OFF
training. Brewer will not brew
E8
when in demo mode.
Reset in E8 to “OFF” to exit
Page 12
Batch Parameters F–HOW TO SAVE SETTINGS
–EXIT & RETURN TO PROGAMMING
IMPORTANT! After programming, you MUST SAVE your settings before exiting programming mode or changes will be lost. Settings are saved from the “F” screen as shown below. You may exit programming at any time. After programmed settings are saved, the brewer exits PROGRAMMING mode and returns to regular brew operations. Settings are saved only when brewer returns to OPERATING MODE DO NOT attempt to save by rebooting (turning power OFF then ON). All changes made will be discarded and brewer will remain in the existing default settings.
Programming A-F
A - F
STOP
1 2
3
From any screen-Press
STOP button until the
EXIT (“F”) screen
appears
STOP
A4
A5
A6
EXIT
A4 A5
A6
F NO +
STOP
1 2
3
From the “F” screen
Press button 2 to
toggle to show the
EXIT-YES screen
STOP
EXIT
F YES –
STOP
STOP
A4 A5
A6
1
2
3
From EXIT-YES screen
Press button 1 to
toggle to show the
SAVE screen
SAVE
STOP
A4 A5
A6
F1 NO +
STOP
1
2
3
From SAVE screen
Press button 2 to
toggle to show the
SAVE-YES screen
SAVE
STOP
A4
A5
A6
F1 YES –
STOP
1 2
3
To SAVE and EXIT
Press button 1 to
SAVE your changes
and to EXIT to
OPERATING MODE
Loading...