Ferroli Talent Installation And Use Instructions Manual

Supplied By www.heating spares.co Tel. 0161 620 6677
TALENT
Wall Mounted
Fan Flue
Gas Multi-Point Water Heater
Phone numbers:
Installer ____________________________
Service Engineer _____________________ Serial N° ____________________________
These Instructions must be left with the appliance User.
3541027/4 • 10/2002
Appr. nr. B 95.06 A - CE 0063 AQ 2150
Wall mounted fanned
flue Water Heater
INSTALLATION AND
USE INSTRUCTIONS
Please read these Instructions
the appliance
Supplied By www.heating spares.co Tel. 0161 620 6677
S.p.A.
INDEX
1- General description and information 2- Technical specifications 3- Installation details 4- Installation 5- Water heater connections 6- Commissioning, operation and shutdown 7- Adjustments 8- Converting to L.P.G. 9- Maintenance requirement
10 - Handing over to user
2
Supplied By www.heating spares.co Tel. 0161 620 6677
S.p.A.
1. GENERAL DESCRIPTION AND INFORMATION
1.1 Information
1. Installation must be carried out by a competent person, and in accordance with the relevant
requirements of the current issues of:
A. Gas Safety (Installation & Use) Regulations. 1994 B. Building Regulations. C. Building Standards (Scotland) Regulations. D. I.E.E. Wiring Regulations. E. Bye-laws of the local water undertaking.
Guidance on Installation is provided in this booklet, but due account must be taken of the detailed recommendations of the current issues of:
BS 5440 Part 1: Flues.
BS 5440 Part 2: Ventilation.
BS 5546: Domestic hot water.
BS 6700: Water supply.
BS 6891: Gas supply.
For installation in timber framed buildings, refer to the British Gas Publication Guide for gas installation in timber framed housing - REF DM2.
2. It is essential that the Water Heater be installed strictly in accordance with these Instructions and
the documents, detailed above.
3. To avoid the possibility of injury, care must be taken when handling sheet metal components.
1.02 Introduction
The Gas Multi Point water heater is a “room-sealed” appliance: it takes in the air required for com- bustion and encloses all the combustion products in an hermetic compartment. The discharge of fumes and intake of combustion air are managed through air/flue pipes that may be run horizontally in all directions, or through a concentric flue running vertically or horizontally.
The main components of the water heater are:
-A compact heat exchanger in copper, formed by four pipes with external finning and internal turbulence activators.
- An insulated combustion chamber to reduce heat loss and thus improve efficiency.
- Four stainless steel burners, an oxidation and thermal shock-resistant material specially developed for this product.
-A fan to discharge combustion products and draw in combustion air.
3
Supplied By www.heating spares.co Tel. 0161 620 6677
S.p.A.
-A high limit thermostat
-A steel room-sealed compartment treated against corrosion, enclosing components.
- An air differential pressure switch which, to ensure safe operation, allows burner ignition only when the fan functions normally.
-A newly-designed gas ignition valve assembly, comprising a fullly modulating gas valve and a flame control device. (Ignition is by an intermittent pilot flame; at the moment a hot water tap is opened, a pilot flame is sparked electronically which lights the main burners.)
-A flowmeter.
-A modulating device which controls the gas valve during use in response to the signal from the flowmeter, the preset temperature and the desired flow rate (water temperature is kept constant with no waste due to temperature fluctuation).
-A water temperature control which allows the user to set the desired temperature - between 40°C and 55°C.
- Five LEDs: one green signalling that the water heater is on, and four yellow displaying water tem­perature.
-A temperature sensor.
-A expansion vessel 3 bar.
4
Supplied By www.heating spares.co Tel. 0161 620 6677
2. TECHNICAL SPECIFICA TION
2.01. Technical Data
Model
S.p.A.
Natural gas (G20) Propane LPG (G31)
Nominal Heat Input (Gross C.V.)
Nominal Heat Input (Net C.V.)
Nominal Heat Output
Pilot Injector
Ø Main Injector
Ø Gas pipe connection
Quantity of main injectors
Gas Inlet Working Pressure
Gas pressure at Main Burners
Gas Flow
min
Max
Max Min
kW
29.7
26.8
kW
24.4
kW
mm
mbar
mbar
mbar
m3/h
kg/h
kW
11.5
10.4
kW
9.7
kW
Natural Gas
(G20)
38/36 A
2.25
3/4"
4
20
2
12.2
2.83
-
Max Min
29.0
kW
26.8
kW
24.4
kW
(G31)
0.25 P
1.40
3/4"
2.07
kW
kW
kW
LPG.
4
37
6
36
-
11.3
10.4
9.7
Water Flow Rate
Maximum Pressure
Adjustable Temperature
Ø Water connections
Dimensions
Weight
Supply voltage
Height
Width
Depth
˘t 25 ¡C
˘t 35 ¡C
min
Max
l/min
l/min
bar
¡C
¡C
mm
mm
mm
kg
V/Hz
14
10
10
40
55
1/2"
700
420
273
33
230/50
5
Supplied By www.heating spares.co Tel. 0161 620 6677
2.02. Dimensions and Measurements
S.p.A.
40
Ø 10
420
340
40
273
710
700
a
b
1
3
50 160 160 50
216
120
c
d
°C
°C
2
e
53
131
Key
73
1. Domestic hot water outlet
2. Domestic cold water inlet
158
3. Gas supply a. Main electrical switch b. LED - Power on (green)
LEDs - Temperature level (yellow)
c. Water temperature control knob
(40°C - 55°C)
d. Overheat cut-off thermostat 90°C
420
Fig. 1
6
Loading...